WWWeiyu Wang

Weiyu Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Weiyu Wang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Review of the Research on the Wide-Band Oscillation Analysis and Suppression of Renewable Energy Grid-Connected Systems

    by Zhu Liu, Dayi Li, Weiyu Wang, Jinfeng Wang, Dehuang Gong

    With the continuous expansion of the scale of power generated by grid-connected renewable energy, the form and operation characteristics of power grids have undergone significant changes, and the power electronic characteristics of power systems are prominent, resulting in the frequent occurrence of wide-band oscillation problems when renewable energy power generation equipment is connected to a power grid. Oscillation has the characteristics of nonlinearity and has an oscillation frequency ranging from a few hertz to several thousand hertz or more, which seriously threatens the stable operation of power grids. This paper summarizes the wide-band oscillation events that occur worldwide under the background of renewable energy access to power grids, classifies the wide-band oscillation events according to the distribution of oscillation frequency bands, and sorts out the characteristics of various oscillations. From the perspectives of the source side and network side, the existing oscillation suppression measures are classified and prospected.


  • Open Access

    Ferro-Resonance Analysis of Capacitor Voltage Transformer with Fast Saturation Damper

    by Xinzhi Ding, Kai Yang, Weiyu Wang, Bin Liu, Xuejin Wang, Jie Zhang, Dayi Li

    With the increase in capacitor voltage transformer (CVT) operation life, CVT impedance changes, and the short-time switching of overhead lines, it is very easy to cause a transient oscillation accident in which a CVT participates, reduce the insulation level of a CVT, and even induce regional power grid oscillation and easily cause capacitor breakdown, after long-term operation with defects. In this paper, the whole power network, including the generator, power grid, and consumer, is modeled, and the theoretical model of the CVT ferro-resonance connected grid is built. The frequency spectrum analysis, and the measurements of resonance bus voltage and line voltage, were carried out to find the design method of a fast saturation damper (FSD) and its voltage–current characteristics that affect the vibration, based on theory and practice; this paper puts forward effective measures to reduce the resonance effect of a CVT in operation, and avoid the oscillation of the line and even the regional power grid system.