Pei Song
Pei Song has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jun Xia
Department of Civil Engineering, Design School, Xi’an Jiaotong-Liverpool University, Suzhou 215123, China
2 shared publications - Chee Seong Chin
Xi’an Jiaotong- Liverpool University
1 shared publication - Rengeng Zheng
Department of Civil Engineering, Design School, Xi’an Jiaotong-Liverpool University, Suzhou 215123, China
1 shared publication - Tianzhen Li
Department of Civil Engineering, Xi’an Jiaotong-Liverpool University, 111 Ren’ai Road, Suzhou 215123, China
1 shared publication - Xiaoxuan Peng
Civil Engineering Department, Design School, Xi’an Jiaotong-Liverpool University, Suzhou 215123, China
1 shared publication
Latest Publications
- Open Access
Material Properties and Mechanical Performances of Manufactured Factory-Produced Glass Fiber-Reinforced Autoclaved Aerated Concrete Panel
Autoclaved aerated concrete (AAC) has gained widespread acceptance in construction as a lightweight solution for exterior and interior walls. However, traditional steel-reinforced autoclaved aerated concrete (SR-AAC) has limitations, including concerns over its ductility and difficulty in cutting during installation. The steel reinforcement also has high embodied carbon that does not align with the actions in the construction section to reach carbon neutrality shortly. This study investigated the material properties and mechanical performances of factory-produced fiber-reinforced autoclaved aerated concrete (FR-AAC) panels, aiming to examine their potential as an alternative solution. Full-scale FR-AAC panels with thicknesses of 100 mm, 150 mm, and 200 mm were manufactured and tested. Some panels were down-sampled to determine the dry density, water absorption, compressive strength, and flexural strength of the material, while the mechanical performances were evaluated through static and impact loading tests. The results showed that the average dry density and absorption of the FR-AAC material are 533 kg/m3 and 63%, respectively, with compressive strengths up to 3.79 MPa and flexural strengths reaching 0.97 MPa. All six panels tested under static uniformly distributed loading exceeded the self-weight limit by a factor of 1.5, satisfying standard requirements for load-bearing capacity. However, the brittle failure modes observed in some tests raise potential health and safety concerns. In contrast, the impact tests revealed that the panels have acceptable performances with the inclusion of fibers.
Open AccessMaterial Properties and Mechanical Performances of Manufactured Factory-Produced Glass Fiber-Reinforced Autoclaved Aerated Concrete Panel
Autoclaved aerated concrete (AAC) has gained widespread acceptance in construction as a lightweight solution for exterior and interior walls. However, traditional steel-reinforced autoclaved aerated concrete (SR-AAC) has limitations, including concerns over its ductility and difficulty in cutting during installation. The steel reinforcement also has high embodied carbon that does not align with the actions in the construction section to reach carbon neutrality shortly. This study investigated the material properties and mechanical performances of factory-produced fiber-reinforced autoclaved aerated concrete (FR-AAC) panels, aiming to examine their potential as an alternative solution. Full-scale FR-AAC panels with thicknesses of 100 mm, 150 mm, and 200 mm were manufactured and tested. Some panels were down-sampled to determine the dry density, water absorption, compressive strength, and flexural strength of the material, while the mechanical performances were evaluated through static and impact loading tests. The results showed that the average dry density and absorption of the FR-AAC material are 533 kg/m3 and 63%, respectively, with compressive strengths up to 3.79 MPa and flexural strengths reaching 0.97 MPa. All six panels tested under static uniformly distributed loading exceeded the self-weight limit by a factor of 1.5, satisfying standard requirements for load-bearing capacity. However, the brittle failure modes observed in some tests raise potential health and safety concerns. In contrast, the impact tests revealed that the panels have acceptable performances with the inclusion of fibers.
- Open Access
Investigation of the Thermal Performance of Lightweight Assembled Exterior Wall Panel (LAEWP) with Stud Connections
One of the most effective ways to improve building energy efficiency and consumption is to increase the thermal insulation of the building envelope and reduce the heat loss through walls. A new type of thermal insulation wall panel, consisting of a lightweight assembled exterior wall panel, was investigated in this research through experimental and numerical analyses. The feasibility of achieving the anticipated thermal performance through finite element modeling using ABAQUS® was verified. Good agreement between numerical simulation and experimental measurement was found, and the accuracy is 98.8%. To further reduce the heat transfer coefficient (U-value) of the panel to improve its thermal performance, parametric analyses were conducted utilizing the validated finite element model. The simulation shows that changing the insulation material is the best option, and the U-value reduction percentage reached 13.2%. Moreover, the combination of reducing the number of steel studs, decreasing the size of steel studs, implementing the opening of the light-gauge steel, and improving the insulation material led to a 23.7% reduction in the U-value at 0.695 W·m−2·K−1.
Open AccessInvestigation of the Thermal Performance of Lightweight Assembled Exterior Wall Panel (LAEWP) with Stud Connections
One of the most effective ways to improve building energy efficiency and consumption is to increase the thermal insulation of the building envelope and reduce the heat loss through walls. A new type of thermal insulation wall panel, consisting of a lightweight assembled exterior wall panel, was investigated in this research through experimental and numerical analyses. The feasibility of achieving the anticipated thermal performance through finite element modeling using ABAQUS® was verified. Good agreement between numerical simulation and experimental measurement was found, and the accuracy is 98.8%. To further reduce the heat transfer coefficient (U-value) of the panel to improve its thermal performance, parametric analyses were conducted utilizing the validated finite element model. The simulation shows that changing the insulation material is the best option, and the U-value reduction percentage reached 13.2%. Moreover, the combination of reducing the number of steel studs, decreasing the size of steel studs, implementing the opening of the light-gauge steel, and improving the insulation material led to a 23.7% reduction in the U-value at 0.695 W·m−2·K−1.