C. Garcıa Ceballos
C. Garcıa Ceballos has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Juan Mora-Florez
Universidad Tecnológica de Pereira
3 shared publications S. Pérez-Londoño
2 shared publications- Sandra Pérez-Londoño
Universidad Tecnológica de Pereira
2 shared publications J. Mora-Flórez
1 shared publication
Latest Publications
- Open Access
- 12 June 2024
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 15 (9)
Fault current limitation approaches for grid-following controlled DERs in microgrid environments
- 12 June 2024
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 15 (9)
Open AccessFault current limitation approaches for grid-following controlled DERs in microgrid environments
- Open Access
- 11 April 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-15
Iterative Approach for Tuning Multiple Converter-Integrated DER in Microgrids
This paper proposes an iterative approach to adjust the control parameters of multiple power converters within a microgrid, which operates in grid-connected and grid-islanded modes. The adequate control parameters are determined using an optimisation-based strategy, local measurements, and results obtained in previous algorithm iterations. The proposed objective function is based on the integral time-weighted absolute error (ITAE), modified to improve the microgrid control performance. The proposed approach addresses the control tuning complexity by considering an incremental strategy, starting from adjusting basic microgrids, continuing to the setting of intermediate microgrids, and finalising when the target microgrid control is fine adjusted. The results obtained at the CIGRE LV benchmark microgrid validate the proposal, obtaining during faults, the maximum deviations from rated frequency around 2.2% and 0.3% in grid-islanded or grid-connected cases, respectively. Also, voltage and power references are adequately followed during steady-state regardless of the microgrid operation mode, where the steady voltage profile is below 10% variation. The obtained results demonstrate the proposed approach advantages, which straightforwardly adjust multiple converters integrated into a microgrid. The main contributions are as follows: (a) the microgrid model is not required, and (b) only measurements at the point of common coupling of the distributed energy resource are used; consequently, the proposed tuning approach is especially applicable to complex microgrids. Finally, finely adjusted microgrids are required for further operation or protection studies where complex system configurations are commonly required.
- 11 April 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-15
Open AccessIterative Approach for Tuning Multiple Converter-Integrated DER in Microgrids
This paper proposes an iterative approach to adjust the control parameters of multiple power converters within a microgrid, which operates in grid-connected and grid-islanded modes. The adequate control parameters are determined using an optimisation-based strategy, local measurements, and results obtained in previous algorithm iterations. The proposed objective function is based on the integral time-weighted absolute error (ITAE), modified to improve the microgrid control performance. The proposed approach addresses the control tuning complexity by considering an incremental strategy, starting from adjusting basic microgrids, continuing to the setting of intermediate microgrids, and finalising when the target microgrid control is fine adjusted. The results obtained at the CIGRE LV benchmark microgrid validate the proposal, obtaining during faults, the maximum deviations from rated frequency around 2.2% and 0.3% in grid-islanded or grid-connected cases, respectively. Also, voltage and power references are adequately followed during steady-state regardless of the microgrid operation mode, where the steady voltage profile is below 10% variation. The obtained results demonstrate the proposed approach advantages, which straightforwardly adjust multiple converters integrated into a microgrid. The main contributions are as follows: (a) the microgrid model is not required, and (b) only measurements at the point of common coupling of the distributed energy resource are used; consequently, the proposed tuning approach is especially applicable to complex microgrids. Finally, finely adjusted microgrids are required for further operation or protection studies where complex system configurations are commonly required.
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Compensated Fault Impedance Estimation for Distance-Based Protection in Active Distribution Networks
Electric distribution networks are experiencing fast changes due to the inclusion of distributed energy resources (DERs). These changes originate active distribution networks (ADNs), where several DERs are integrated, frequently using power converters. In ADN, the conventional control, operation, and protection schemes used in power systems are unsuitable; new approaches must be proposed and tested. This paper analyses the distance relay performance in ADNs, and as the main contribution, a communication−less compensation strategy is proposed to deal with the effects of fault resistance and the DERs infeed and remote currents. The obtained results demonstrate the excellent performance of the proposed compensation strategy aimed at determining the true value of the estimated positive sequence impedance. This compensation can be easily integrated into the software of conventional distance relays to overcome fault resistance, infeed, and remote current effects.
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessCompensated Fault Impedance Estimation for Distance-Based Protection in Active Distribution Networks
Electric distribution networks are experiencing fast changes due to the inclusion of distributed energy resources (DERs). These changes originate active distribution networks (ADNs), where several DERs are integrated, frequently using power converters. In ADN, the conventional control, operation, and protection schemes used in power systems are unsuitable; new approaches must be proposed and tested. This paper analyses the distance relay performance in ADNs, and as the main contribution, a communication−less compensation strategy is proposed to deal with the effects of fault resistance and the DERs infeed and remote currents. The obtained results demonstrate the excellent performance of the proposed compensation strategy aimed at determining the true value of the estimated positive sequence impedance. This compensation can be easily integrated into the software of conventional distance relays to overcome fault resistance, infeed, and remote current effects.