CWCatherine M. Weiss

Catherine M. Weiss

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Catherine M. Weiss has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Water-Transport Resistance of Perfluorosulfonic-Acid (PFSA) Membranes: Delineating the Role of Interface and Chemistry

    by Catherine M. Weiss, Shouwen Shi, Adam Z. Weber, Ahmet Kusoglu

    The proton-exchange membrane (PEM) is an integral component in PEM fuel cells, water electrolyzers, and other electrochemical energy-conversion devices. In these devices, the PEM must conduct protons but inhibit reactant/product gas crossover; its operation depends heavily on its hydration level. Furthermore, PEMs exhibit complicated water management balanced between transport phenomena, interfacial resistance, and the electro-osmosis vs back-transport trade-off, all of which also depend on external environmental conditions. In this paper, we investigate interfacial and bulk water-transport resistance for perfluorosulfonic-acid (PFSA) membranes with long, medium, and short side-chain lengths (Nafion, 3M, and Aquivion, respectively) in controlled temperature-humidity environments. Using a factorial design of experiments based on 12 chemistry-thickness × 16 environmental conditions, a large systematic dataset is constructed. Transport resistance decreases with increasing temperature and RH, with the latter having an order-of-magnitude higher impact. Water content (λ), or water volume fraction (ϕ), is the key controlling parameter, where all resistances decrease with increasing water content. The interfacial resistance diminishes with increasing side-chain length, while the bulk resistance is the lowest for the medium side-chain length, indicating that the water-transport relationship with the internal polymer structure is more convoluted. Activation-energy analysis further reveals that interfacial resistance requires substantially more thermal energy to overcome than bulk resistance, confirming that the two are governed by distinct transport mechanisms that respond differently to side-chain chemistry and hydration conditions. These findings provide a mechanistic framework for tailoring PEM chemistry to balance water transport and proton conductivity in next-generation membrane design.

  • Unmasking Ionomer Degradation in Cathode Catalyst Layers of Polymer Electrolyte Fuel Cells

    by Catherine Weiss, Ramchandra Gawas, Sarah Stewart, Ahmet Kusoglu, Rangachary Mukundan

    The widespread deployment of proton exchange membrane fuel cells (PEMFCs) in demanding heavy-duty vehicle applications requires longer system lifetimes necessitating unprecedented durability. While the degradation mechanisms of the bulk perfluorosulfonic acid ionomer membrane are well documented, the susceptibility of the nanometer-thin catalyst layer (CL) ionomer films in electrodes remains a critical unanswered question. Here, we conclusively demonstrate that the current membrane accelerated stress test (AST) does induce CL ionomer degradation through changes in the CL ionomer properties, primarily the CL ionic resistance, when compared to two control tests. The CL ionomer degradation from the AST decreases the PEMFC performance by approximately 90 mV @ 1 A cm–2. Moreover, we demonstrate that this CL ionomer degradation can be eliminated by the incorporation of cerium, a common membrane additive to scavenge radicals.


  • A Relief Zone Architecture for Improved Durability of Ultra-Thin Membranes In Electrochemical Conversion Devices

    by Audrey K. Taylor, Megan McVeigh, Catherine M. Weiss, Kenneth C. Neyerlin

    State-of-the-art polymer electrolyte membranes (PEMs) used in electrochemical systems are prepared with ultra-thin dimensions (i.e., ≤ 15 μm-thick) to reduce cost and improve performance, however, trade-offs arise from increased reactant crossover and compromised mechanical stability. Consequently, membrane electrode assemblies (MEAs) incorporating such PEMs are particularly susceptible to premature cell failures. Mechanical degradation of the PEM can result from stress concentrations introduced from device-level integration distinct from those experienced during operation. Herein, a relief zone was developed to mitigate mechanical degradation by alleviating non-uniform compression across the active area, enabling durable, reproducible operation of ultra-thin PEMs. The relief zone concept was demonstrated using fuel cells as a case study and validated using the aggressive DOE combined chemical-mechanical accelerated stress test (AST). Relief zones, created through the ablation of carbonaceous diffusion material demonstrate a seamless adaptation across a range of MEA dimensions and electrochemical applications without need for costly hardware modifications. Accelerated stress test validations yielded a six-fold improvement for MEAs prepared with relief zones (i.e., lifetime ~1500 h) compared to those fabricated using conventional edge-protection techniques, showcasing the utility of this technique in decoupling integration and device-level engineering effects from intrinsic material limitations for durable electrochemical devices.

  • Open Access

    Understanding Operando Water Management in Hydroxide‐Exchange‐Membrane Fuel Cells

    by Catherine M. Weiss, Shiyi Wang, Brian P. Setzler, Yushan Yan, Adam Z. Weber

    The water balance in hydroxide‐exchange‐membrane fuel cells (HEMFCs) is a key challenge for improved performance and durability, intimately linked with the various interfaces and coupled phenomena. For every 4 electrons produced, 4 water molecules are generated in the anode and 2 consumed in the cathode, while electroosmosis transports water across the HEM from the cathode to the anode. Consequently, a concentration gradient drives water back, from anode to cathode. Ineffective water management could lead to cathode dry‐out, limiting reaction rate and causing ionomer degradation, or to anode flooding. To address these concerns, it is critical to measure the water transport operando . Herein, a home‐built water‐flux station is used to measure total water flux during cell operation with different inlet relative humidities and back pressures. Increasing the HEM thickness fourfold decreases the water flux at high current density, and utilizing microporous layers on both the anode and cathode decreases the water flux from the anode to the cathode. However, the most significant variable in changing the water flux was found by increasing the anode back pressure. Furthermore, humidity cycling significantly changed electrochemical performance without affecting the overall water fluxes. These findings can be translated to other devices utilizing an HEM.


  • Open Access

    Relief Zones Enhance the Durability of Ultrathin Membranes in Electrochemical Conversion Devices

    by Audrey K. Taylor, Megan McVeigh, Catherine Weiss, Kenneth C. Neyerlin

    Premature failures in electrochemical conversion systems often result when membrane electrode assemblies (MEAs) use ultrathin (≤15 μm-thick) polymer electrolyte membranes, susceptible to mechanical degradation from stress concentrations arising from device-level integration. Herein, relief zones were developed to mitigate mechanical degradation by alleviating excess and nonuniform compression across active areas. Relief zones, created through ablation of carbonaceous diffusion media, enable seamless adaptation across MEA dimensions without need for hardware modifications. Demonstrated using fuel cells as a case study, accelerated stress tests revealed a 6-fold lifetime improvement (∼1500 h) compared to conventional edge-protected MEAs, decoupling device-level engineering effects from material limitations.


  • Membrane Degradation in PEM Fuel Cells: Modeling Gas Crossover and the Pt Band

    by Evan F. Johnson, Catherine M. Weiss, Rangachary Mukundan, Adam Z. Weber

    Chemical degradation of perfluorinated sulfonic acid membranes remains a critical barrier to the long-term durability of proton exchange membrane fuel cells. Various degradation mechanisms have been proposed, yet fundamental questions remain unanswered about the origin of radicals that lead to unzipping of the polymer chain. In this work, we have developed a 2D species transport model that explicitly resolves gas, ionomer, and catalyst agglomerates as discrete phases. This approach reveals new insights regarding how hydrogen and oxygen crossover lead to membrane degradation as well as the role of the platinum band in radical generation. Simulations indicate that gas crossover is high at open circuit voltage, while at working potentials the reactant gas is largely consumed at the interface between the catalyst layer and membrane. High gas crossover at open circuit voltage directly fuels the simultaneous hydrogen oxidation and oxygen reduction on Pt particles within the membrane, driving the increase in both degradation and peroxide generation that are experimentally observed. The model is then used to explore how the geometry of the interfacial region between the catalyst layer and the membrane affects gas crossover and degradation. These findings are important for understanding the conditions that exacerbate chemical degradation, including defects such as catalyst layer cracks and delaminations. These insights help explain membrane degradation phenomena and provide pathways to mitigate this degradation. Figure 1

  • Degradation of Fuel Cell Membrane Electrode Assemblies from Buses Operated More Than 25,000 Hours

    by Arthur Dizon, Harsh Srivastav, Ali A. Sadhakkathullahil, Grace Y. Lau, Douglas I. Kushner, Rangachary Mukundan, Adam Z. Weber, David A. Cullen, Clayton J. Radke, Lynda Amichi, et al.

    This study investigates the degradation of proton exchange membrane fuel cell stacks taken from the Alameda Contra Costa Transit District (AC Transit) bus system (Alameda and Contra Costa counties, California, United States) that were operated for over 25,000 hours. Here, we focus on the origin of differences in electrochemical performance between beginning-of-life (BOL) and end-of-life (EOL) states as well as diagnostic data acquired during the lifetime of the buses. In doing so, we employ characterization methods such as polarization curves, electrochemical impedance spectroscopy, Scanning Electron Microscopy (SEM) imaging, Transmission Electron Microscopy (TEM) imaging, X-ray Fluorescence (XRF), and X-ray Diffraction (XRD). Uniform degradation was observed in all of the post-teardown measurements, which showed some changes compared to BOL materials resulting from years of field operation. Despite these changes, the measured post-teardown performance suggests a sufficient output for the expected load of the buses, which indicate factors other than degradation of the membrane-electrode assemblies (MEAs) are likely responsible for the decommissioning of the stacks. The findings indicate that these MEA materials can enable long lifetime in fuel-cell vehicles, if the MEAs are not subjected to adverse operating conditions. The results also highlight the need for more in-vehicle diagnostics to maximize the lifetime of Fuel Cell Vehicle (FCV) powerplants. This work was supported by the Hydrogen and Fuel Cell Technologies Office (HFTO), Office of Energy Efficiency and Renewable Energy, U.S. Department of Energy (DOE) through the Million Mile Fuel Cell Truck (M2FCT) consortia, technology managers G. Kleen and D. Papageorgopoulos, under Contract Number DE-AC02-05CH11231. All opinions expressed in this article are of the authors’ and do not necessarily reflect the policies and views of the DOE. The authors would like to thank Jose Vega, James Souza, and Cecil O. Blandon from the Alameda Contra Costa Transit District for their help in providing the data taken over the lifetime of the fuel cell buses.

  • Effect of Contaminates and Additives on Degradation in Fuel Cells

    by Catherine M. Weiss, Evan F. Johnson, Ramchandra Gawas, Rangachary Mukundan

    Proton Exchange Membrane Fuel Cells (PEMFC) are a technology gaining traction for hydrogen-fueled transportation applications, especially for heavy-duty vehicles. The stringent durability requirements for heavy-duty application (>25,000 hours) require a better understanding of the degradation mechanism and development of mitigation strategies for improving the durability. In particular, the durability of the membrane-electrode assemblies (MEA) is a key research area especially with growing interest of accelerated stress testing (AST) developed for heavy-duty applications. The current mitigation strategies for the proton exchange membrane are adding radical scavengers to minimize the chemical degradation induced by radical attacks and reinforcing the membrane for maximizing mechanical endurance. However, it is yet to be fully understood how the chemical decomposition pathways change in the presence of cationic contaminants and cerium-based additives. The most damaging contaminant is iron due to its ability to catalyst the decomposition of hydrogen peroxide to hydroxyl radical, Fenton’s reagent, which exacerbates membrane degradation. Here, we investigate the chemical degradation of fuel cell membranes using accelerated stress tests under different conditions while characterizing the change in membrane resistance, H 2 permeability, fuel cell performance, and fluoride emission rate over time. These results will be used to provide new insights on the degradation mechanism pathways with a focus on the interplay of contaminants and additives governing the lifetime of the fuel cell membranes. The refinement of the membrane/MEA accelerated stress tests for heavy-duty transportation applications will also be discussed.


  • Open Access

    Degradation of Fuel Cell Membrane Electrode Assemblies from Buses Operated More than 25,000 h

    by Harsh Srivastav, Arthur Dizon, Lynda Amichi, Mike L. Perry, Ali Aboobaker Sadhakkathullahil, Grace Lau, Catherine M. Weiss, Brice Florey, Douglas I. Kushner, Matthew Wilson, et al.

    This study investigates the performance losses and degradation of proton-exchange-membrane fuel-cell stacks taken from the Alameda Contra Costa Transit District (AC Transit) bus system (Alameda and Contra Costa counties, California, United States) that were operated for over 25,000 h. Here, we focus on the origin of differences in electrochemical performance between beginning-of-life (BOL) and end-of-life states as well as diagnostic data acquired during the lifetime of the buses. In doing so, we employ in- and ex- situ characterization methods such as polarization curves, electrochemical impedance spectroscopy, electron microscopy, and X-ray characterization. Uniform degradation of the catalyst layer including Pt agglomeration/migration and electrode thinning was observed in all of the post-teardown measurements compared to BOL materials resulting from years of field operation. Despite these changes, the measured post-teardown performance suggests a sufficient output for the expected load, which indicate factors other than degradation of the membrane-electrode assemblies (MEAs) are likely responsible for the decommissioning of the stacks. The findings indicate that these MEA materials can enable long lifetime in fuel-cell vehicles, if the MEAs are not subjected to adverse operating conditions. The results also highlight the need for more in-vehicle diagnostics to maximize the lifetime of fuel cell vehicle (FCV) powerplants.


  • Advanced Alkaline Membrane H2/Air Fuel Cell System with Novel Technique for Air CO2 Removal

    by USDOE Advanced Research Projects Agency - Energy (ARPA-E), Yushan Yan, Newark Univ. Of Delaware, Shimshon Gottesfeld, Lin Shi, Brian Setzler, Yun Zhao, Stephanie Matz, Catherine Weiss