Vicente J. León-Muñoz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vicente J. León-Muñoz has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Ana B. Ponce-Garrido
Department of Rehabilitation Sciences and Physiotherapy, General Hospital, Almansa, 02640 Albacete, Spain
1 shared publication - Fernando Santonja-Medina
Faculty of Medicine, University of Murcia, 30100 Murcia, Spain
1 shared publication - Fernando Santonja-Renedo
Primary Health Service Area IX, 30720 Murcia, Spain
1 shared publication - Francisco Javier Sánchez-Martínez
Medicine Faculty, University of Murcia, 30100 Murcia, Spain
1 shared publication - Joaquín Alcaraz-Belzunces
Medicine Faculty, University of Murcia, 30100 Murcia, Spain
1 shared publication - Jose Manuel Sanz-Mengibar
Centre for Neuromuscular Diseases, National Hospital for Neurology and Neurosurgery, University College London Queen Square, London WC1N 3BG, UK
1 shared publication
Latest Publications
- Open Access
- 12 April 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (8) , 4655
Validity and Absolute Reliability of the Cobb Angle in Idiopathic Scoliosis with TraumaMeter Software
The Cobb angle value is a critical parameter for evaluating adolescent idiopathic scoliosis (AIS) patients. This study aimed to evaluate a software’s validity and absolute reliability to determine the Cobb angle in AIS digital X-rays, with two different degrees of experienced observers. Four experts and four novice evaluators measured 35 scoliotic curves with the software on three separate occasions, one month apart. The observers re-measured the same radiographic studies on three separate occasions three months later but on conventional X-ray films. The differences between the mean bias errors (MBE) within the experience groups were statistically significant between the experts (software) and novices (manual) (p < 0.001) and between the novices (software) and novices (manual) (p = 0.005). When measured with the software, the intra-group error in the expert group was MBE = 1.71 ± 0.61° and the intraclass correlation coefficient (ICC (2,1)) = 0.986, and in the novice group, MBE = 1.9 ± 0.67° and ICC (2,1) = 0.97. There was almost a perfect concordance among the two measurement methods, ICC (2,1) = 0.998 and minimum detectable change (MCD95) < 0.4°. Control of the intrinsic error sources enabled obtaining inter- and intra-observer MDC95 < 0.5° in the two experience groups and with the two measurement methods. The computer-aided software TraumaMeter increases the validity and reliability of Cobb angle measurements concerning manual measurement.
- 12 April 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (8) , 4655
Open AccessValidity and Absolute Reliability of the Cobb Angle in Idiopathic Scoliosis with TraumaMeter Software
The Cobb angle value is a critical parameter for evaluating adolescent idiopathic scoliosis (AIS) patients. This study aimed to evaluate a software’s validity and absolute reliability to determine the Cobb angle in AIS digital X-rays, with two different degrees of experienced observers. Four experts and four novice evaluators measured 35 scoliotic curves with the software on three separate occasions, one month apart. The observers re-measured the same radiographic studies on three separate occasions three months later but on conventional X-ray films. The differences between the mean bias errors (MBE) within the experience groups were statistically significant between the experts (software) and novices (manual) (p < 0.001) and between the novices (software) and novices (manual) (p = 0.005). When measured with the software, the intra-group error in the expert group was MBE = 1.71 ± 0.61° and the intraclass correlation coefficient (ICC (2,1)) = 0.986, and in the novice group, MBE = 1.9 ± 0.67° and ICC (2,1) = 0.97. There was almost a perfect concordance among the two measurement methods, ICC (2,1) = 0.998 and minimum detectable change (MCD95) < 0.4°. Control of the intrinsic error sources enabled obtaining inter- and intra-observer MDC95 < 0.5° in the two experience groups and with the two measurement methods. The computer-aided software TraumaMeter increases the validity and reliability of Cobb angle measurements concerning manual measurement.