Mousa Moradi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mousa Moradi has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Nazlee Zebardast
Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
6 shared publications - Tobias Elze
Massachusetts Eye and Ear Infirmary, Harvard University, Boston, MA; and
6 shared publications Mengyu Wang
Harvard Ophthalmology AI Lab, Schepens Eye Research Institute of Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, United States
5 shared publications- Asahi Fujita
Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA; Department of Ophthalmology, Graduate School of Medicine, the University of Tokyo, Tokyo, Japan
4 shared publications - Mohammad Eslami
Massachusetts Eye and Ear Infirmary
4 shared publications - Yu Chen
Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
4 shared publications
Latest Publications
- Open Access
- 23 September 2026
- Published by MDPI AG in Machine Learning and Knowledge Extraction
- Vol. 8  (10) , 295
Asymmetric Focal Loss Improves Graph Neural Network Prediction of Drug-Pair-Associated Polypharmacy Side Effects
Accurate prediction of drug-pair-associated polypharmacy side effects remains an important challenge in computational pharmacovigilance. Standard binary cross-entropy (BCE) may provide insufficient emphasis on difficult positive examples. We evaluated ClinicalFocal, an asymmetric focal-loss function that assigns different focusing exponents and class weights to observed positive and generated negative drug-side-effect-drug triples, within a relation-aware graph convolutional network. On TWOSIDES, five-fold cross-validation showed that ClinicalFocal increased accuracy from 0.699 to 0.892 (19.3 percentage points), F1 score from 0.700 to 0.894 (19.4 percentage points), AUROC from 0.766 to 0.914, and AUCPR from 0.714 to 0.860. Sensitivity increased from 0.702 to 0.909, while overall classification error decreased from 30.1% to 10.8%, a 64.1% relative reduction. Brier score decreased from 0.183 to 0.147, a 19.6% relative reduction, indicating improved probability-level predictive accuracy. After independent 100-trial loss-specific optimization, ClinicalFocal remained superior across all five folds. These findings support loss-function design as an important determinant of graph-based polypharmacy side-effect prediction.- 23 September 2026
- Published by MDPI AG in Machine Learning and Knowledge Extraction
- Vol. 8  (10) , 295
Open AccessAsymmetric Focal Loss Improves Graph Neural Network Prediction of Drug-Pair-Associated Polypharmacy Side Effects
Accurate prediction of drug-pair-associated polypharmacy side effects remains an important challenge in computational pharmacovigilance. Standard binary cross-entropy (BCE) may provide insufficient emphasis on difficult positive examples. We evaluated ClinicalFocal, an asymmetric focal-loss function that assigns different focusing exponents and class weights to observed positive and generated negative drug-side-effect-drug triples, within a relation-aware graph convolutional network. On TWOSIDES, five-fold cross-validation showed that ClinicalFocal increased accuracy from 0.699 to 0.892 (19.3 percentage points), F1 score from 0.700 to 0.894 (19.4 percentage points), AUROC from 0.766 to 0.914, and AUCPR from 0.714 to 0.860. Sensitivity increased from 0.702 to 0.909, while overall classification error decreased from 30.1% to 10.8%, a 64.1% relative reduction. Brier score decreased from 0.183 to 0.147, a 19.6% relative reduction, indicating improved probability-level predictive accuracy. After independent 100-trial loss-specific optimization, ClinicalFocal remained superior across all five folds. These findings support loss-function design as an important determinant of graph-based polypharmacy side-effect prediction. - Open Access
Clinically aligned rationale generation for glaucoma subtype classification via a knowledge-distilled language model
Automated glaucoma subtype classification from clinical notes remains clinically unactionable without subspecialty-aligned explanations supporting clinician-facing deployment. We extended our Ci-SSGAN with a GPT-5.2-to-Qwen3-8B teacher-distilled reasoning module, fine-tuning Qwen3-8B on 2,660 de-identified ophthalmology notes using expert-reviewed rationales. On 294 notes, the fine-tuned model achieved ROUGE-L 0.792 ± 0.013 and BERTScore F1 0.955 ± 0.004, surpassing eight zero-shot comparators including GPT-4o and GPT-4.1, establishing privacy-preserving distillation as a path to interpretable AI.
Open AccessClinically aligned rationale generation for glaucoma subtype classification via a knowledge-distilled language model
Automated glaucoma subtype classification from clinical notes remains clinically unactionable without subspecialty-aligned explanations supporting clinician-facing deployment. We extended our Ci-SSGAN with a GPT-5.2-to-Qwen3-8B teacher-distilled reasoning module, fine-tuning Qwen3-8B on 2,660 de-identified ophthalmology notes using expert-reviewed rationales. On 294 notes, the fine-tuned model achieved ROUGE-L 0.792 ± 0.013 and BERTScore F1 0.955 ± 0.004, surpassing eight zero-shot comparators including GPT-4o and GPT-4.1, establishing privacy-preserving distillation as a path to interpretable AI.
- Open Access
- 25 June 2026
- Published by Springer Nature in Research Square
Sparse-Observation Multi-Horizon Glaucoma Progression Forecasting with Biologically Constrained Temporal Consistency: A Glaucoma Case Study
Glaucoma progression forecasting from sparse longitudinal data remains unsolved, as existing models require dense multi-year inputs and lack the biological constraints. We introduce a sparse-observation framework that predicts multi-horizon outcomes from only two visits, incorporating a novel TCMH (Temporally Consistent Multi-Horizon) loss that enforces monotonic risk ordering to reflect irreversible disease biology. Applied to glaucoma progression, we integrate circumpapillary retinal nerve fiber layer (cpRNFL) images, visual field total deviation (VFTD) maps, and clinical covariates through ConvNeXt architecture trained with TCMH loss. In 3,593 patients (13,087 sequences), our model achieved AUROC 0.968 and accuracy 0.947 for two-, three-, and four-year progression forecasting, with 10.2% better calibration than baseline and 0.0163 maximum demographic disparity. At 90% coverage, classification error remained 2.5%, enabling automated risk stratification with expert review for only uncertain cases. The model exceeded three independent specialist graders on specificity (0.98 vs. 0.57–0.73) on 108 held-out eyes. These results establish sparse-observation temporally consistent forecasting as a generalizable paradigm for calibrated long-horizon risk prediction in irreversible progressive diseases.
- 25 June 2026
- Published by Springer Nature in Research Square
Open AccessSparse-Observation Multi-Horizon Glaucoma Progression Forecasting with Biologically Constrained Temporal Consistency: A Glaucoma Case Study
Glaucoma progression forecasting from sparse longitudinal data remains unsolved, as existing models require dense multi-year inputs and lack the biological constraints. We introduce a sparse-observation framework that predicts multi-horizon outcomes from only two visits, incorporating a novel TCMH (Temporally Consistent Multi-Horizon) loss that enforces monotonic risk ordering to reflect irreversible disease biology. Applied to glaucoma progression, we integrate circumpapillary retinal nerve fiber layer (cpRNFL) images, visual field total deviation (VFTD) maps, and clinical covariates through ConvNeXt architecture trained with TCMH loss. In 3,593 patients (13,087 sequences), our model achieved AUROC 0.968 and accuracy 0.947 for two-, three-, and four-year progression forecasting, with 10.2% better calibration than baseline and 0.0163 maximum demographic disparity. At 90% coverage, classification error remained 2.5%, enabling automated risk stratification with expert review for only uncertain cases. The model exceeded three independent specialist graders on specificity (0.98 vs. 0.57–0.73) on 108 held-out eyes. These results establish sparse-observation temporally consistent forecasting as a generalizable paradigm for calibrated long-horizon risk prediction in irreversible progressive diseases.
- 14 April 2026
- Published by Elsevier in Ophthalmology
- Vol. 133  (8) , 985-993
Development of Perimetric Glaucoma and Outcomes of Interventions in Pseudoexfoliation Syndrome with and without Ocular Hypertension
- 14 April 2026
- Published by Elsevier in Ophthalmology
- Vol. 133  (8) , 985-993
Development of Perimetric Glaucoma and Outcomes of Interventions in Pseudoexfoliation Syndrome with and without Ocular Hypertension
- Open Access
Multimodal Deep Learning for Longitudinal Prediction of Glaucoma Progression Using Sequential RNFL, Visual Field, and Clinical Data
Forecasting glaucoma progression remains a major challenge in preventing irreversible vision loss. We developed and validated a multimodal, longitudinal deep learning framework to predict future progression using a large retrospective cohort of 10,864 patients from Mass Eye and Ear. The model integrates sequential structural (OCT RNFL scans), functional (visual-field maps), and clinical data from a two-year observation window to forecast progression over the subsequent two-to four-year horizon. Four backbone architectures (ConvNeXt-V2, ViT, MobileNet-V2, EfficientNet-B0) were coupled with a bidirectional LSTM to capture temporal dynamics. The ConvNeXt-V2-based model achieved 0.97 AUC and 0.94–0.96 accuracy, outperforming other backbones with robust performance across sex and race subgroups and only modest attenuation in those > 70 years. Saliency maps localized to clinically relevant arcuate bundles, supporting biological plausibility. By effectively fusing multimodal data over time, this framework enables accurate, interpretable, and equitable long-horizon risk stratification, advancing personalized glaucoma management.
Open AccessMultimodal Deep Learning for Longitudinal Prediction of Glaucoma Progression Using Sequential RNFL, Visual Field, and Clinical Data
Forecasting glaucoma progression remains a major challenge in preventing irreversible vision loss. We developed and validated a multimodal, longitudinal deep learning framework to predict future progression using a large retrospective cohort of 10,864 patients from Mass Eye and Ear. The model integrates sequential structural (OCT RNFL scans), functional (visual-field maps), and clinical data from a two-year observation window to forecast progression over the subsequent two-to four-year horizon. Four backbone architectures (ConvNeXt-V2, ViT, MobileNet-V2, EfficientNet-B0) were coupled with a bidirectional LSTM to capture temporal dynamics. The ConvNeXt-V2-based model achieved 0.97 AUC and 0.94–0.96 accuracy, outperforming other backbones with robust performance across sex and race subgroups and only modest attenuation in those > 70 years. Saliency maps localized to clinically relevant arcuate bundles, supporting biological plausibility. By effectively fusing multimodal data over time, this framework enables accurate, interpretable, and equitable long-horizon risk stratification, advancing personalized glaucoma management.
- Open Access
Clinically Informed Semi-Supervised Learning Improves Disease Annotation and Equity from Electronic Health Records: A Glaucoma Case Study
Clinical notes represent a vast but underutilized source of information for disease characterization, whereas structured electronic health record (EHR) data such as ICD codes are often noisy, incomplete, and too coarse to capture clinical complexity. These limitations constrain the accuracy of datasets used to investigate disease pathogenesis and progression and to develop robust artificial intelligence (AI) systems. To address this challenge, we introduce Ci-SSGAN (Clinically Informed Semi-Supervised Generative Adversarial Network), a novel framework that leverages large-scale unlabeled clinical text to reannotate patient conditions with improved accuracy and equity. As a case study, we applied Ci-SSGAN to glaucoma, a leading cause of irreversible blindness characterized by pronounced racial and ethnic disparities. Trained on 2.1 million ophthalmology notes, Ci-SSGAN achieved 0.85 accuracy and 0.95 AUROC, representing a 10.19% AUROC improvement compared to ICD-based labels (0.74 accuracy, 0.85 AUROC). Ci-SSGAN also narrowed subgroup performance gaps, with F1 gains for Black patients (+0.05), women (+0.06), and younger patients (+0.033). By integrating semi-supervised learning and demographic conditioning, Ci-SSGAN minimizes reliance on expert annotations, making AI development more accessible to resource-constrained healthcare systems.
Open AccessClinically Informed Semi-Supervised Learning Improves Disease Annotation and Equity from Electronic Health Records: A Glaucoma Case Study
Clinical notes represent a vast but underutilized source of information for disease characterization, whereas structured electronic health record (EHR) data such as ICD codes are often noisy, incomplete, and too coarse to capture clinical complexity. These limitations constrain the accuracy of datasets used to investigate disease pathogenesis and progression and to develop robust artificial intelligence (AI) systems. To address this challenge, we introduce Ci-SSGAN (Clinically Informed Semi-Supervised Generative Adversarial Network), a novel framework that leverages large-scale unlabeled clinical text to reannotate patient conditions with improved accuracy and equity. As a case study, we applied Ci-SSGAN to glaucoma, a leading cause of irreversible blindness characterized by pronounced racial and ethnic disparities. Trained on 2.1 million ophthalmology notes, Ci-SSGAN achieved 0.85 accuracy and 0.95 AUROC, representing a 10.19% AUROC improvement compared to ICD-based labels (0.74 accuracy, 0.85 AUROC). Ci-SSGAN also narrowed subgroup performance gaps, with F1 gains for Black patients (+0.05), women (+0.06), and younger patients (+0.033). By integrating semi-supervised learning and demographic conditioning, Ci-SSGAN minimizes reliance on expert annotations, making AI development more accessible to resource-constrained healthcare systems.
- Open Access
OphthaBERT: Automated Glaucoma Diagnosis from Clinical Notes
Glaucoma is a leading cause of irreversible blindness worldwide, with early intervention often being crucial. Research into the underpinnings of glaucoma often relies on electronic health records (EHRs) to identify patients with glaucoma and their subtypes. However, current methods for identifying glaucoma patients from EHRs are often inaccurate or infeasible at scale, relying on International Classification of Diseases (ICD) codes or manual chart reviews. To address this limitation, we introduce (1) OphthaBERT, a powerful general clinical ophthalmology language model trained on over 2 million diverse clinical notes, and (2) a fine-tuned variant of OphthaBERT that automatically extracts binary and subtype glaucoma diagnoses from clinical notes. The base OphthaBERT model is a robust encoder, outperforming state-of-the-art clinical encoders in masked token prediction on out-of-distribution ophthalmology clinical notes and binary glaucoma classification with limited data. We report significant binary classification performance improvements in low-data regimes (p < 0.001, Bonferroni corrected). OphthaBERT is also able to achieve superior classification performance for both binary and subtype diagnosis, outperforming even fine-tuned large decoder-only language models at a fraction of the computational cost. We demonstrate a 0.23-point increase in macro-F1 for subtype diagnosis over ICD codes and strong binary classification performance when externally validated at Wilmer Eye Institute. OphthaBERT provides an interpretable, equitable framework for general ophthalmology language modeling and automated glaucoma diagnosis.
Open AccessOphthaBERT: Automated Glaucoma Diagnosis from Clinical Notes
Glaucoma is a leading cause of irreversible blindness worldwide, with early intervention often being crucial. Research into the underpinnings of glaucoma often relies on electronic health records (EHRs) to identify patients with glaucoma and their subtypes. However, current methods for identifying glaucoma patients from EHRs are often inaccurate or infeasible at scale, relying on International Classification of Diseases (ICD) codes or manual chart reviews. To address this limitation, we introduce (1) OphthaBERT, a powerful general clinical ophthalmology language model trained on over 2 million diverse clinical notes, and (2) a fine-tuned variant of OphthaBERT that automatically extracts binary and subtype glaucoma diagnoses from clinical notes. The base OphthaBERT model is a robust encoder, outperforming state-of-the-art clinical encoders in masked token prediction on out-of-distribution ophthalmology clinical notes and binary glaucoma classification with limited data. We report significant binary classification performance improvements in low-data regimes (p < 0.001, Bonferroni corrected). OphthaBERT is also able to achieve superior classification performance for both binary and subtype diagnosis, outperforming even fine-tuned large decoder-only language models at a fraction of the computational cost. We demonstrate a 0.23-point increase in macro-F1 for subtype diagnosis over ICD codes and strong binary classification performance when externally validated at Wilmer Eye Institute. OphthaBERT provides an interpretable, equitable framework for general ophthalmology language modeling and automated glaucoma diagnosis.
- Open Access
PyGlaucoMetrics: A Stacked Weight-Based Machine Learning Approach for Glaucoma Detection Using Visual Field Data
Background and Objectives: Glaucoma (GL) classification is crucial for early diagnosis and treatment, yet relying solely on stand-alone models or International Classification of Diseases (ICD) codes is insufficient due to limited predictive power and inconsistencies in clinical labeling. This study aims to improve GL classification using stacked weight-based machine learning models. Materials and Methods: We analyzed a subset of 33,636 participants (58% female) with 340,444 visual fields (VFs) from the Mass Eye and Ear (MEE) dataset. Five clinically relevant GL detection models (LoGTS, UKGTS, Kang, HAP2_part1, and Foster) were selected to serve as base models. Two multi-layer perceptron (MLP) models were trained using 52 total deviation (TD) and pattern deviation (PD) values from Humphrey field analyzer (HFA) 24-2 VF tests, along with four clinical variables (age, gender, follow-up time, and race) to extract model weights. These weights were then utilized to train three meta-learners, including logistic regression (LR), extreme gradient boosting (XGB), and MLP, to classify cases as GL or non-GL. Results: The MLP meta-learner achieved the highest performance, with an accuracy of 96.43%, an F-score of 96.01%, and an AUC of 97.96%, while also demonstrating the lowest prediction uncertainty (0.08 ± 0.13). XGB followed with 92.86% accuracy, a 92.31% F-score, and a 96.10% AUC. LR had the lowest performance, with 89.29% accuracy, an 86.96% F-score, and a 94.81% AUC, as well as the highest uncertainty (0.58 ± 0.07). Permutation importance analysis revealed that the superior temporal sector was the most influential VF feature, with importance scores of 0.08 in Kang’s and 0.04 in HAP2_part1 models. Among clinical variables, age was the strongest contributor (score = 0.3). Conclusions: The meta-learner outperformed stand-alone models in GL classification, achieving an accuracy improvement of 8.92% over the best-performing stand-alone model (LoGTS with 87.51%), offering a valuable tool for automated glaucoma detection.
Open AccessPyGlaucoMetrics: A Stacked Weight-Based Machine Learning Approach for Glaucoma Detection Using Visual Field Data
Background and Objectives: Glaucoma (GL) classification is crucial for early diagnosis and treatment, yet relying solely on stand-alone models or International Classification of Diseases (ICD) codes is insufficient due to limited predictive power and inconsistencies in clinical labeling. This study aims to improve GL classification using stacked weight-based machine learning models. Materials and Methods: We analyzed a subset of 33,636 participants (58% female) with 340,444 visual fields (VFs) from the Mass Eye and Ear (MEE) dataset. Five clinically relevant GL detection models (LoGTS, UKGTS, Kang, HAP2_part1, and Foster) were selected to serve as base models. Two multi-layer perceptron (MLP) models were trained using 52 total deviation (TD) and pattern deviation (PD) values from Humphrey field analyzer (HFA) 24-2 VF tests, along with four clinical variables (age, gender, follow-up time, and race) to extract model weights. These weights were then utilized to train three meta-learners, including logistic regression (LR), extreme gradient boosting (XGB), and MLP, to classify cases as GL or non-GL. Results: The MLP meta-learner achieved the highest performance, with an accuracy of 96.43%, an F-score of 96.01%, and an AUC of 97.96%, while also demonstrating the lowest prediction uncertainty (0.08 ± 0.13). XGB followed with 92.86% accuracy, a 92.31% F-score, and a 96.10% AUC. LR had the lowest performance, with 89.29% accuracy, an 86.96% F-score, and a 94.81% AUC, as well as the highest uncertainty (0.58 ± 0.07). Permutation importance analysis revealed that the superior temporal sector was the most influential VF feature, with importance scores of 0.08 in Kang’s and 0.04 in HAP2_part1 models. Among clinical variables, age was the strongest contributor (score = 0.3). Conclusions: The meta-learner outperformed stand-alone models in GL classification, achieving an accuracy improvement of 8.92% over the best-performing stand-alone model (LoGTS with 87.51%), offering a valuable tool for automated glaucoma detection.
- Open Access
- 20 February 2025
- Published by MDPI AG in Preprints.org
PyGlaucoMetrics: A Weight Stacking- Based Machine Learning Approach for Glaucoma Detection Using Visual Field Data
Background and Objectives: Glaucoma (GL) classification is crucial for early diagnosis and treatment, yet relying solely on stand-alone models or International Classification of Diseases (ICD) codes is insufficient due to limited predictive power and inconsistencies in clinical labeling. This study aims to improve GL classification by stacking weights using machine learning-based models. Materials and Methods: We analyzed a subset of 33,636 participants (58% female) with 340,444 visual fields (VFs) from the Mass Eye and Ear (MEE) dataset. Five clinically relevant GL detection models (LoGTS, UKGTS, Kang, HAP2_part1, and Foster) were selected to serve as base models. Two Multi-Layer Perceptron (MLP) models were trained using 52 total deviation (TD) and pattern deviation (PD) values from Humphrey Field Analyzer (HFA) 24-2 VF tests, along with four clinical variables (age, gender, follow-up time, and race) to extract model weights. These weights were then utilized to train three meta-learners including Logistic Regression (LR), Extreme Gradient Boosting (XGB), and MLP to classify cases as GL or non-GL. Results: The MLP meta-learner achieved the highest performance, with an accuracy of 96.43%, an F-score of 96.01%, and an AUC of 97.96%, while also demonstrating the lowest prediction uncertainty (0.08 ± 0.13). XGB followed with 92.86% accuracy, a 92.31% F-score, and a 96.10% AUC. LR had the lowest performance, with 89.29% accuracy, an 86.96% F-score, and a 94.81% AUC, as well as the highest uncertainty (0.58 ± 0.07). Permutation importance analysis revealed that the superior temporal sector was the most influential VF feature, with importance scores of 0.08 in Kang’s and 0.04 in HAP2_ part1 models. Among clinical variables, age was the strongest contributor (score= 0.3). Conclusion: The meta-learning approach outperformed stand-alone models in GL classification, offering a valuable tool for automated glaucoma assessment.
- 20 February 2025
- Published by MDPI AG in Preprints.org
Open AccessPyGlaucoMetrics: A Weight Stacking- Based Machine Learning Approach for Glaucoma Detection Using Visual Field Data
Background and Objectives: Glaucoma (GL) classification is crucial for early diagnosis and treatment, yet relying solely on stand-alone models or International Classification of Diseases (ICD) codes is insufficient due to limited predictive power and inconsistencies in clinical labeling. This study aims to improve GL classification by stacking weights using machine learning-based models. Materials and Methods: We analyzed a subset of 33,636 participants (58% female) with 340,444 visual fields (VFs) from the Mass Eye and Ear (MEE) dataset. Five clinically relevant GL detection models (LoGTS, UKGTS, Kang, HAP2_part1, and Foster) were selected to serve as base models. Two Multi-Layer Perceptron (MLP) models were trained using 52 total deviation (TD) and pattern deviation (PD) values from Humphrey Field Analyzer (HFA) 24-2 VF tests, along with four clinical variables (age, gender, follow-up time, and race) to extract model weights. These weights were then utilized to train three meta-learners including Logistic Regression (LR), Extreme Gradient Boosting (XGB), and MLP to classify cases as GL or non-GL. Results: The MLP meta-learner achieved the highest performance, with an accuracy of 96.43%, an F-score of 96.01%, and an AUC of 97.96%, while also demonstrating the lowest prediction uncertainty (0.08 ± 0.13). XGB followed with 92.86% accuracy, a 92.31% F-score, and a 96.10% AUC. LR had the lowest performance, with 89.29% accuracy, an 86.96% F-score, and a 94.81% AUC, as well as the highest uncertainty (0.58 ± 0.07). Permutation importance analysis revealed that the superior temporal sector was the most influential VF feature, with importance scores of 0.08 in Kang’s and 0.04 in HAP2_ part1 models. Among clinical variables, age was the strongest contributor (score= 0.3). Conclusion: The meta-learning approach outperformed stand-alone models in GL classification, offering a valuable tool for automated glaucoma assessment.
- Open Access
- 2 September 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3  (1) , 1-12
Large area kidney imaging for pre-transplant evaluation using real-time robotic optical coherence tomography
Optical coherence tomography (OCT) can be used to image microstructures of human kidneys. However, current OCT probes exhibit inadequate field-of-view, leading to potentially biased kidney assessment. Here we present a robotic OCT system where the probe is integrated to a robot manipulator, enabling wider area (covers an area of 106.39 mm by 37.70 mm) spatially-resolved imaging. Our system comprehensively scans the kidney surface at the optimal altitude with preoperative path planning and OCT image-based feedback control scheme. It further parameterizes and visualizes microstructures of large area. We verified the system positioning accuracy on a phantom as 0.0762 ± 0.0727 mm and showed the clinical feasibility by scanning ex vivo kidneys. The parameterization reveals vasculatures beneath the kidney surface. Quantification on the proximal convoluted tubule of a human kidney yields clinical-relevant information. The system promises to assess kidney viability for transplantation after collecting a vast amount of whole-organ parameterization and patient outcomes data.
- 2 September 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3  (1) , 1-12
Open AccessLarge area kidney imaging for pre-transplant evaluation using real-time robotic optical coherence tomography
Optical coherence tomography (OCT) can be used to image microstructures of human kidneys. However, current OCT probes exhibit inadequate field-of-view, leading to potentially biased kidney assessment. Here we present a robotic OCT system where the probe is integrated to a robot manipulator, enabling wider area (covers an area of 106.39 mm by 37.70 mm) spatially-resolved imaging. Our system comprehensively scans the kidney surface at the optimal altitude with preoperative path planning and OCT image-based feedback control scheme. It further parameterizes and visualizes microstructures of large area. We verified the system positioning accuracy on a phantom as 0.0762 ± 0.0727 mm and showed the clinical feasibility by scanning ex vivo kidneys. The parameterization reveals vasculatures beneath the kidney surface. Quantification on the proximal convoluted tubule of a human kidney yields clinical-relevant information. The system promises to assess kidney viability for transplantation after collecting a vast amount of whole-organ parameterization and patient outcomes data.