Chen-Yu Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chen-Yu Chen has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- William E. Bentley
Fischell Department of Bioengineering University of Maryland College Park Maryland USA
7 shared publications - Gregory Francis Payne
Institute for Bioscience and Biotechnology Research University of Maryland College Park Maryland USA
5 shared publications - Eunkyoung Kim
Institute for Bioscience and Biotechnology Research University of Maryland College Park Maryland 20742 USA
4 shared publications - Fauziah Rahma Zakaria
Fischell Department of Bioengineering, University of Maryland, College Park, USA
3 shared publications Chen-Yu Tsao
Institute for Bioscience and Biotechnology Research, University of Maryland, College Park, MD, 20742, United States
2 shared publicationsGregory F. Payne
Institute for Bioscience and Biotechnology Research University of Maryland College Park Maryland USA
2 shared publications
Latest Publications
- Open Access
- 12 July 2026
- Published by Wiley in Small Science
- Vol. 6 (7)
Programable and Spatially Conforming Assembly of Engineered Living Materials Onto Electrodes via Redox
We developed an electrobiofabrication methodology that assembles well‐defined cell/gel formations directly onto electrodes. For this, we oxidatively crosslinked terminal thiols of a 4‐arm thiolated polyethylene glycol (PEG) by the purposeful addition of a ferrocene redox mediator to a PEG/cell assembly solution and the application of an oxidizing charge to an electrode. Because the resulting disulfide bonds are created near the electrode, the crosslinked hydrogel assembly is defined by the electrode dimensions and the time over which the oxidative potential is applied. Results indicate a strong positive correlation between the mediator concentration, the delivered oxidative charge, the number density of cells in the assembly solution and the subsequent gel thickness and density. In all cases tested, the viability of the assembled cells ( E. coli bacteria) was near 100%. We further demonstrated a gravity‐mediated layering methodology to create spatially defined interfaces, as well as electroassembly onto various conductive materials of nearly arbitrary shape. These results represent a means for electronic or “programed” assembly of cell laden hydrogels, enabling further study of cell–cell interactions, cell‐device interactions, biosensing, device ⇔ bio communication, and several applications such as electrogenetics wherein cell genetic circuits are actuated by application of electrical potentials using a redox‐enabled communication modality.
- 12 July 2026
- Published by Wiley in Small Science
- Vol. 6 (7)
Open AccessProgramable and Spatially Conforming Assembly of Engineered Living Materials Onto Electrodes via Redox
We developed an electrobiofabrication methodology that assembles well‐defined cell/gel formations directly onto electrodes. For this, we oxidatively crosslinked terminal thiols of a 4‐arm thiolated polyethylene glycol (PEG) by the purposeful addition of a ferrocene redox mediator to a PEG/cell assembly solution and the application of an oxidizing charge to an electrode. Because the resulting disulfide bonds are created near the electrode, the crosslinked hydrogel assembly is defined by the electrode dimensions and the time over which the oxidative potential is applied. Results indicate a strong positive correlation between the mediator concentration, the delivered oxidative charge, the number density of cells in the assembly solution and the subsequent gel thickness and density. In all cases tested, the viability of the assembled cells ( E. coli bacteria) was near 100%. We further demonstrated a gravity‐mediated layering methodology to create spatially defined interfaces, as well as electroassembly onto various conductive materials of nearly arbitrary shape. These results represent a means for electronic or “programed” assembly of cell laden hydrogels, enabling further study of cell–cell interactions, cell‐device interactions, biosensing, device ⇔ bio communication, and several applications such as electrogenetics wherein cell genetic circuits are actuated by application of electrical potentials using a redox‐enabled communication modality.
- Open Access
- 12 March 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (8) , 1947-1958
3D nanoprinting of PDMS microvessels with tailored tortuosity and microporosity via direct laser writing
A novel two-photon direct laser writing-based hybrid strategy for 3D nanoprinting microfluidic vessels with sophisticated 3D architectures and custom-designed micropores.
- 12 March 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (8) , 1947-1958
Open Access3D nanoprinting of PDMS microvessels with tailored tortuosity and microporosity via direct laser writing
A novel two-photon direct laser writing-based hybrid strategy for 3D nanoprinting microfluidic vessels with sophisticated 3D architectures and custom-designed micropores.
- Open Access
- 16 September 2024
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 121 (12) , 3754-3767
Electrobiofabrication of antibody sensor interfaces within a 3D printed device yield rapid and robust electrochemical measurements of titer and glycan structure
We report the integration of 3D printing, electrobiofabrication, and protein engineering to create a device that enables near real‐time analysis of monoclonal antibody (mAb) titer and quality. 3D printing was used to create the macroscale architecture that can control fluidic contact of a sample with multiple electrodes for replicate measurements. An analysis “chip” was configured as a “snap‐in” module for connecting to a 3D printed housing containing fluidic and electronic communication systems. Electrobiofabrication was used to functionalize each electrode by the assembly of a hydrogel interface containing biomolecular recognition and capture proteins. Specifically, an electrochemical thiol oxidation is used to assemble a thiolated polyethylene glycol hydrogel, that in turn is covalently coupled to either a cysteine‐tagged protein G that binds the antibody's Fc region or a lectin that binds the glycans of target mAb analytes. We first show the design, assembly, and testing of the hardware device. Then, we show the transition of a step‐by‐step sensing methodology (e.g., mix, incubate, wash, mix, incubate, wash, measure) into the current method where functionalization, antibody capture, and assessment are performed in situ and in parallel channels. Both titer and glycan analyses were found to be linear with antibody concentration (to 0.2 mg/L). We further found the interfaces could be reused with remarkably similar results. Because the interface assembly and use are simple, rapid, and robust, we suggest this assessment methodology will be widely applicable, including for other biomolecular process development and manufacturing environments.
- 16 September 2024
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 121 (12) , 3754-3767
Open AccessElectrobiofabrication of antibody sensor interfaces within a 3D printed device yield rapid and robust electrochemical measurements of titer and glycan structure
We report the integration of 3D printing, electrobiofabrication, and protein engineering to create a device that enables near real‐time analysis of monoclonal antibody (mAb) titer and quality. 3D printing was used to create the macroscale architecture that can control fluidic contact of a sample with multiple electrodes for replicate measurements. An analysis “chip” was configured as a “snap‐in” module for connecting to a 3D printed housing containing fluidic and electronic communication systems. Electrobiofabrication was used to functionalize each electrode by the assembly of a hydrogel interface containing biomolecular recognition and capture proteins. Specifically, an electrochemical thiol oxidation is used to assemble a thiolated polyethylene glycol hydrogel, that in turn is covalently coupled to either a cysteine‐tagged protein G that binds the antibody's Fc region or a lectin that binds the glycans of target mAb analytes. We first show the design, assembly, and testing of the hardware device. Then, we show the transition of a step‐by‐step sensing methodology (e.g., mix, incubate, wash, mix, incubate, wash, measure) into the current method where functionalization, antibody capture, and assessment are performed in situ and in parallel channels. Both titer and glycan analyses were found to be linear with antibody concentration (to 0.2 mg/L). We further found the interfaces could be reused with remarkably similar results. Because the interface assembly and use are simple, rapid, and robust, we suggest this assessment methodology will be widely applicable, including for other biomolecular process development and manufacturing environments.
- Open Access
- 28 June 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 262, 116546
Redox-mediated Biomolecular information transfer in single electrogenetic biological cells
- 28 June 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 262, 116546
Open AccessRedox-mediated Biomolecular information transfer in single electrogenetic biological cells
- Open Access
- 21 December 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-17
Redox-enabled electronic interrogation and feedback control of hierarchical and networked biological systems
Microelectronic devices can directly communicate with biology, as electronic information can be transmitted via redox reactions within biological systems. By engineering biology’s native redox networks, we enable electronic interrogation and control of biological systems at several hierarchical levels: proteins, cells, and cell consortia. First, electro-biofabrication facilitates on-device biological component assembly. Then, electrode-actuated redox data transmission and redox-linked synthetic biology allows programming of enzyme activity and closed-loop electrogenetic control of cellular function. Specifically, horseradish peroxidase is assembled onto interdigitated electrodes where electrode-generated hydrogen peroxide controls its activity. E. coli’s stress response regulon, oxyRS, is rewired to enable algorithm-based feedback control of gene expression, including an eCRISPR module that switches cell-cell quorum sensing communication from one autoinducer to another—creating an electronically controlled ‘bilingual’ cell. Then, these disparate redox-guided devices are wirelessly connected, enabling real-time communication and user-based control. We suggest these methodologies will help us to better understand and develop sophisticated control for biology.
- 21 December 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-17
Open AccessRedox-enabled electronic interrogation and feedback control of hierarchical and networked biological systems
Microelectronic devices can directly communicate with biology, as electronic information can be transmitted via redox reactions within biological systems. By engineering biology’s native redox networks, we enable electronic interrogation and control of biological systems at several hierarchical levels: proteins, cells, and cell consortia. First, electro-biofabrication facilitates on-device biological component assembly. Then, electrode-actuated redox data transmission and redox-linked synthetic biology allows programming of enzyme activity and closed-loop electrogenetic control of cellular function. Specifically, horseradish peroxidase is assembled onto interdigitated electrodes where electrode-generated hydrogen peroxide controls its activity. E. coli’s stress response regulon, oxyRS, is rewired to enable algorithm-based feedback control of gene expression, including an eCRISPR module that switches cell-cell quorum sensing communication from one autoinducer to another—creating an electronically controlled ‘bilingual’ cell. Then, these disparate redox-guided devices are wirelessly connected, enabling real-time communication and user-based control. We suggest these methodologies will help us to better understand and develop sophisticated control for biology.
- Open Access
Redox Active Plant Phenolic, Acetosyringone, for Electrogenetic Signaling
Redox is a unique, programmable modality capable of bridging communication between biology and electronics. Previous studies have shown that the E. coli redox-responsive OxyRS regulon can be re-wired to accept electrochemically generated hydrogen peroxide (H 2 O 2 ) as an inducer of gene expression. Here we report that the redox-active phenolic plant signaling molecule acetosyringone (AS) can also induce gene expression from the OxyRS regulon. AS must be oxidized, however, as the reduced state present under normal conditions cannot induce gene expression. Thus, AS serves as a “pro-signaling molecule” that can be activated by its oxidation - in our case by application of oxidizing potential to an electrode. We show that the OxyRS regulon is not induced electrochemically if the imposed electrode potential is in the mid-physiological range. Electronically sliding the applied potential to either oxidative or reductive extremes induces this regulon but through different mechanisms: reduction of O 2 to form H 2 O 2 or oxidation of AS. Fundamentally, this work reinforces the emerging concept that redox signaling depends more on molecular activities than molecular structure. From an applications perspective, the creation of an electronically programmed “pro-signal” dramatically expands the toolbox for electronic control of biological responses in microbes, including in complex environments, cell-based materials, and biomanufacturing.
Open AccessRedox Active Plant Phenolic, Acetosyringone, for Electrogenetic Signaling
Redox is a unique, programmable modality capable of bridging communication between biology and electronics. Previous studies have shown that the E. coli redox-responsive OxyRS regulon can be re-wired to accept electrochemically generated hydrogen peroxide (H 2 O 2 ) as an inducer of gene expression. Here we report that the redox-active phenolic plant signaling molecule acetosyringone (AS) can also induce gene expression from the OxyRS regulon. AS must be oxidized, however, as the reduced state present under normal conditions cannot induce gene expression. Thus, AS serves as a “pro-signaling molecule” that can be activated by its oxidation - in our case by application of oxidizing potential to an electrode. We show that the OxyRS regulon is not induced electrochemically if the imposed electrode potential is in the mid-physiological range. Electronically sliding the applied potential to either oxidative or reductive extremes induces this regulon but through different mechanisms: reduction of O 2 to form H 2 O 2 or oxidation of AS. Fundamentally, this work reinforces the emerging concept that redox signaling depends more on molecular activities than molecular structure. From an applications perspective, the creation of an electronically programmed “pro-signal” dramatically expands the toolbox for electronic control of biological responses in microbes, including in complex environments, cell-based materials, and biomanufacturing.
- Open Access
- 20 October 2022
- Published by Wiley in Advanced Materials Interfaces
- Vol. 9 (35)
Characterizing Electron Flow through Catechol‐Graphene Composite Hydrogels
Electronic materials that allow the controlled flow of electrons in aqueous media are required for emerging applications that require biocompatibility, safety, and/or sustainability. Here, a composite hydrogel film composed of graphene and catechol is electrofabricated, and that this composite offers synergistic properties is reported. Graphene confers metal‐like conductivity and enables charge‐storage through an electrical double layer mechanism. Catechol confers redox‐activity and enables charge‐storage through a redox mechanism. Importantly, there are two functional populations of catechols: conducting‐catechols (presumably in intimate contact with graphene) allow direct electron‐transfer; and non‐conducting‐catechols (presumably physically separated from graphene) require diffusible mediators to enable electron‐transfer. Using a variety of spectroelectrochemical measurements, that the capacity of the composite for charge‐storage increases in proportion to the extent by which the catechol‐groups can undergo redox‐state switching is demonstrated. To illustrate the broad relevance of this work, how the redox‐state switching can be related to both the charge storage of energy materials and the memory of molecular electronic materials is discussed. The authors believe this work is significant because it demonstrates that: conducting and redox‐active components enable distinctly different mechanisms for charge‐storage and electron‐transfer; these components act synergistically; and mediators provide unique opportunities to extend the capabilities of electronic materials.
- 20 October 2022
- Published by Wiley in Advanced Materials Interfaces
- Vol. 9 (35)
Open AccessCharacterizing Electron Flow through Catechol‐Graphene Composite Hydrogels
Electronic materials that allow the controlled flow of electrons in aqueous media are required for emerging applications that require biocompatibility, safety, and/or sustainability. Here, a composite hydrogel film composed of graphene and catechol is electrofabricated, and that this composite offers synergistic properties is reported. Graphene confers metal‐like conductivity and enables charge‐storage through an electrical double layer mechanism. Catechol confers redox‐activity and enables charge‐storage through a redox mechanism. Importantly, there are two functional populations of catechols: conducting‐catechols (presumably in intimate contact with graphene) allow direct electron‐transfer; and non‐conducting‐catechols (presumably physically separated from graphene) require diffusible mediators to enable electron‐transfer. Using a variety of spectroelectrochemical measurements, that the capacity of the composite for charge‐storage increases in proportion to the extent by which the catechol‐groups can undergo redox‐state switching is demonstrated. To illustrate the broad relevance of this work, how the redox‐state switching can be related to both the charge storage of energy materials and the memory of molecular electronic materials is discussed. The authors believe this work is significant because it demonstrates that: conducting and redox‐active components enable distinctly different mechanisms for charge‐storage and electron‐transfer; these components act synergistically; and mediators provide unique opportunities to extend the capabilities of electronic materials.
- 5 April 2022
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
- Vol. 6 (10) , 1253-1260
Orthogonal redox and optical stimuli can induce independent responses for catechol-chitosan films
Top-down measurements of catechol films show orthogonal energy flow via redox and optical modalities. These molecular electronic properties enable communication through both short-range redox modalities and long-range electromagnetic modalities.
- 5 April 2022
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
- Vol. 6 (10) , 1253-1260
Orthogonal redox and optical stimuli can induce independent responses for catechol-chitosan films
Top-down measurements of catechol films show orthogonal energy flow via redox and optical modalities. These molecular electronic properties enable communication through both short-range redox modalities and long-range electromagnetic modalities.