Carlos F. Uribe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carlos F. Uribe has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Arman Rahmim
Department of Radiology, The University of British Columbia, Vancouver, Canada; Department of Physics and Astronomy, The University of British Columbia, Vancouver, Canada; Department of Biomedical Engineering, The University of British Columbia, Vancouver, Canada
1 shared publication- Brandon Driscoll
Techna Institute, University Health Network, Toronto, ON M5G 2C4, Canada
1 shared publication - Brian Nghiem
Krembil Brain Institute, University Health Network Toronto Ontario Canada
1 shared publication - Charles Ross Schmidtlein
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
1 shared publication - David Anthony Jaffray
The University of Texas MD Anderson Cancer Center, Houston, TX
1 shared publication Fereshteh Yousefirizi
Department of Radiology, The University of British Columbia, Vancouver, Canada; Department of Basic and Translational Research, BC Cancer Research Institute, Vancouver, Canada
1 shared publication
Latest Publications
- 30 October 2025
- Published by Elsevier in PET Clinics
- Vol. 21 (1) , 43-54
Seeing More, Treating Smarter
- 30 October 2025
- Published by Elsevier in PET Clinics
- Vol. 21 (1) , 43-54
Seeing More, Treating Smarter
- Open Access
- 13 April 2022
- Published by MDPI AG in Tomography
- Vol. 8 (2) , 1113-1128
Noise-Based Image Harmonization Significantly Increases Repeatability and Reproducibility of Radiomics Features in PET Images: A Phantom Study
For multicenter clinical studies, characterizing the robustness of image-derived radiomics features is essential. Features calculated on PET images have been shown to be very sensitive to image noise. The purpose of this work was to investigate the efficacy of a relatively simple harmonization strategy on feature robustness and agreement. A purpose-built texture pattern phantom was scanned on 10 different PET scanners in 7 institutions with various different image acquisition and reconstruction protocols. An image harmonization technique based on equalizing a contrast-to-noise ratio was employed to generate a “harmonized” alongside a “standard” dataset for a reproducibility study. In addition, a repeatability study was performed with images from a single PET scanner of variable image noise, varying the binning time of the reconstruction. Feature agreement was measured using the intraclass correlation coefficient (ICC). In the repeatability study, 81/93 features had a lower ICC on the images with the highest image noise as compared to the images with the lowest image noise. Using the harmonized dataset significantly improved the feature agreement for five of the six investigated feature classes over the standard dataset. For three feature classes, high feature agreement corresponded with higher sensitivity to the different patterns, suggesting a way to select suitable features for predictive models.
- 13 April 2022
- Published by MDPI AG in Tomography
- Vol. 8 (2) , 1113-1128
Open AccessNoise-Based Image Harmonization Significantly Increases Repeatability and Reproducibility of Radiomics Features in PET Images: A Phantom Study
For multicenter clinical studies, characterizing the robustness of image-derived radiomics features is essential. Features calculated on PET images have been shown to be very sensitive to image noise. The purpose of this work was to investigate the efficacy of a relatively simple harmonization strategy on feature robustness and agreement. A purpose-built texture pattern phantom was scanned on 10 different PET scanners in 7 institutions with various different image acquisition and reconstruction protocols. An image harmonization technique based on equalizing a contrast-to-noise ratio was employed to generate a “harmonized” alongside a “standard” dataset for a reproducibility study. In addition, a repeatability study was performed with images from a single PET scanner of variable image noise, varying the binning time of the reconstruction. Feature agreement was measured using the intraclass correlation coefficient (ICC). In the repeatability study, 81/93 features had a lower ICC on the images with the highest image noise as compared to the images with the lowest image noise. Using the harmonized dataset significantly improved the feature agreement for five of the six investigated feature classes over the standard dataset. For three feature classes, high feature agreement corresponded with higher sensitivity to the different patterns, suggesting a way to select suitable features for predictive models.