Isabel Breidert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Isabel Breidert has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Christian Bunck
Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937 Cologne, Germany
1 shared publication - Alexander Hof
University of Cologne
1 shared publication - Christopher Hohmann
University of Cologne, Faculty of Medicine and University Hospital of Cologne, Department III of Internal Medicine, Heart Center, Kerpener Straße 62, D-50931, Cologne, Germany
1 shared publication - David Maintz
Institute for Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Cologne, University of Cologne, 50937 Cologne, Germany
1 shared publication - Elmar Kuhn
Department of Cardiothoracic Surgery, Heart Center, University Hospital Cologne, 50937 Cologne, Germany
1 shared publication - Hendrik Wienemann
Clinic III for Internal Medicine (H.W., M.A.), Faculty of Medicine and University Hospital Cologne, Germany
1 shared publication
Latest Publications
- Open Access
- 14 April 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (4) , 116
Feasibility and Comparison of Resting Full-Cycle Ratio and Computed Tomography Fractional Flow Reserve in Patients with Severe Aortic Valve Stenosis
Background: Computed tomography derived Fractional Flow Reserve (CT-FFR) has been shown to decrease the referral rate for invasive coronary angiography (ICA). The purpose of the study was to evaluate the diagnostic performance of CT-FFR compared to hyperemia-free index Resting Full-cycle Ratio (RFR) in patients with relevant aortic stenosis (AS) and intermediate coronary stenosis. Methods: 41 patients with 46 coronary lesions underwent ICA with quantitative coronary angiography (QCA), pressure wire assessment and routine pre-transcatheter aortic valve replacement (TAVR) computed tomography (CT). CT-FFR analysis was performed using prototype on-site software. Results: RFR showed a significant correlation with CT-FFR (Pearson’s correlation, r = 0.632, p < 0.001). On a per-lesion basis, diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of CT-FFR were 82.6% (95% CI 68.6–92.2), 69.6% (95% CI 47.1–86.8), 95.7% (95% CI 78.1–99.9), 94.1% (95% CI 69.8–99.1), and 75.9% (95% CI 62.7–85.4), respectively. The optimal cutoff value of the CT-FFR for RFR ≤ 0.89 prediction was 0.815. The area under the receiver curve showed a larger area under the curve for CT-FFR (0.87; 95% CI 0.75–0.98) compared with CTA stenosis of ≥50% (0.54, 95% CI 0.38–0.71), CTA ≥ 70% (0.72, 95% CI 0.57–0.87) and QCA ≥ 50% (0.67, 95% CI 0.52–0.83). Conclusions: CT-FFR assessed by routine pre-TAVR CT is safe and feasible and shows a significant correlation with RFR in patients with AS. CT-FFR is superior to QCA ≥ 50%, CT ≥ 50% and CT ≥ 70% in assessing the hemodynamic relevance of intermediate coronary lesions. Thus, CT-FFR has the potential to guide revascularization in patients with AS.
- 14 April 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (4) , 116
Open AccessFeasibility and Comparison of Resting Full-Cycle Ratio and Computed Tomography Fractional Flow Reserve in Patients with Severe Aortic Valve Stenosis
Background: Computed tomography derived Fractional Flow Reserve (CT-FFR) has been shown to decrease the referral rate for invasive coronary angiography (ICA). The purpose of the study was to evaluate the diagnostic performance of CT-FFR compared to hyperemia-free index Resting Full-cycle Ratio (RFR) in patients with relevant aortic stenosis (AS) and intermediate coronary stenosis. Methods: 41 patients with 46 coronary lesions underwent ICA with quantitative coronary angiography (QCA), pressure wire assessment and routine pre-transcatheter aortic valve replacement (TAVR) computed tomography (CT). CT-FFR analysis was performed using prototype on-site software. Results: RFR showed a significant correlation with CT-FFR (Pearson’s correlation, r = 0.632, p < 0.001). On a per-lesion basis, diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of CT-FFR were 82.6% (95% CI 68.6–92.2), 69.6% (95% CI 47.1–86.8), 95.7% (95% CI 78.1–99.9), 94.1% (95% CI 69.8–99.1), and 75.9% (95% CI 62.7–85.4), respectively. The optimal cutoff value of the CT-FFR for RFR ≤ 0.89 prediction was 0.815. The area under the receiver curve showed a larger area under the curve for CT-FFR (0.87; 95% CI 0.75–0.98) compared with CTA stenosis of ≥50% (0.54, 95% CI 0.38–0.71), CTA ≥ 70% (0.72, 95% CI 0.57–0.87) and QCA ≥ 50% (0.67, 95% CI 0.52–0.83). Conclusions: CT-FFR assessed by routine pre-TAVR CT is safe and feasible and shows a significant correlation with RFR in patients with AS. CT-FFR is superior to QCA ≥ 50%, CT ≥ 50% and CT ≥ 70% in assessing the hemodynamic relevance of intermediate coronary lesions. Thus, CT-FFR has the potential to guide revascularization in patients with AS.