Junwon Min
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Junwon Min has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Dongchoul Kim
1 shared publication- Dongchoul Kim
Department of Mechanical Engineering, Sogang University, Seoul, Republic of Korea
1 shared publication Jeong Ha Hwang
1 shared publication- Keumrai Whang
Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 04107, Korea
1 shared publication Taewook Kang
1 shared publication- Taewook Kang
Department of Chemical and Biomolecular Engineering, Sogang University, Seoul, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 15 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (8) , 4006
Effect of Mass Transport by Convective Flow on the Distribution of Dissolved Carbon Monoxide in a Stirred Tank
The dissolved gas concentration in a stirred tank has significant importance in the chemical and biological processing industries as mass transfer from the injected gas to an aqueous solution must occur for the gas to be usable. As the solubility of the gas in the solution is low and there are no probes for measuring dissolved gas concentration, a volumetric mass transfer coefficient is selected as a criterion of design for the scale-up of stirred reactors. However, it is difficult to accurately predict the non-equilibrium state dissolved gas distribution using only the volumetric mass transfer coefficient. In this study, computational fluid dynamics (CFD)-based numerical analysis was conducted to systematically evaluated the effects of mass transport by convective flow on the distribution of dissolved carbon monoxide in a stirred tank. The dissolved carbon monoxide distribution and the volumetric mass transfer coefficient were compared at various rotational speeds of the impellers. At a rotational speed of 900 RPM, the Pearson correlation coefficient was about 0.52, which denotes a moderate correlation. In contrast, Pearson correlation coefficients less than 0.20 were obtained for speeds less than 700 RPM, indicating a weak correlation. By considering the dissolved carbon monoxide transport that occurs during convective flow in stirred tanks, we can provide more accurate information about the dissolved carbon monoxide distribution.
- 15 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (8) , 4006
Open AccessEffect of Mass Transport by Convective Flow on the Distribution of Dissolved Carbon Monoxide in a Stirred Tank
The dissolved gas concentration in a stirred tank has significant importance in the chemical and biological processing industries as mass transfer from the injected gas to an aqueous solution must occur for the gas to be usable. As the solubility of the gas in the solution is low and there are no probes for measuring dissolved gas concentration, a volumetric mass transfer coefficient is selected as a criterion of design for the scale-up of stirred reactors. However, it is difficult to accurately predict the non-equilibrium state dissolved gas distribution using only the volumetric mass transfer coefficient. In this study, computational fluid dynamics (CFD)-based numerical analysis was conducted to systematically evaluated the effects of mass transport by convective flow on the distribution of dissolved carbon monoxide in a stirred tank. The dissolved carbon monoxide distribution and the volumetric mass transfer coefficient were compared at various rotational speeds of the impellers. At a rotational speed of 900 RPM, the Pearson correlation coefficient was about 0.52, which denotes a moderate correlation. In contrast, Pearson correlation coefficients less than 0.20 were obtained for speeds less than 700 RPM, indicating a weak correlation. By considering the dissolved carbon monoxide transport that occurs during convective flow in stirred tanks, we can provide more accurate information about the dissolved carbon monoxide distribution.