Ernest L. Yufenyuy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ernest L. Yufenyuy has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Bharat S. Parekh
Division of Global HIV & TB, CGH, CDC
4 shared publications - Jeni Vuong
Affiliation Division of Global HIV & TB, Centers for Disease Control and Prevention, Atlanta, Georgia, United States of America
3 shared publications Amy Zheng
Affiliations Division of Global HIV & TB, Centers for Disease Control and Prevention, Atlanta, Georgia, United States of America, Public Health Institute/Centers for Disease Control, Global Health Fellowship Program, Atlanta, Georgia, United States of America
2 shared publications- Amy Zheng
Department of Epidemiology Boston University School of Public Health Boston Massachusetts USA
2 shared publications - Diana L. Martin
Centers for Disease Control and Prevention, Atlanta, Georgia
2 shared publications - Mahesh Swaminathan
U.S. Centers for Disease Control and Prevention, P.O. Box 9123 Dar es Salaam, Tanzania
2 shared publications
Latest Publications
- Open Access
- 9 April 2025
- Published by Public Library of Science (PLoS) in PLOS Global Public Health
- Vol. 5 (4) , e0003455
Field validation and application of the luminex triplex HIV assay to estimate HIV prevalence and HIV-1 incidence in Nigeria
HIV cross-sectional surveys require multi-layered testing with several tests to estimate HIV prevalence and HIV-1 incidence. We evaluated the performance and accuracy of the newly developed HIV Triplex assay to diagnose HIV-1 and HIV-2 and detect HIV-1 recent infections using plasma samples from the 2018 Nigeria AIDS Indicator and Impact Survey (NAIIS). Plasma samples from consenting HIV-positive (n=2,773) and a subset of HIV-negative samples (n=7,196), as determined by the national rapid testing algorithm, followed by Bio-Rad Geenius HIV-1/2 Supplemental Assay and Western Blot, aged 18 months - 64 years, were tested using the Luminex-based HIV Triplex assay. The assay classified specimens as HIV-1 positive, HIV-2 positive, dual (HIV-1 & 2) infections, or HIV-seronegative. All HIV-1 and dual infections were further classified as either HIV-1 recent (kappa of 0.987 when compared to NAIIS survey results. Percent agreement between the HIV Triplex assay and the LAg-Avidity EIA for recent and LT classification was 98.86% with a kappa of 0.80 [CI: 0.71-0.89] and a Spearman-ranked correlation (ρ) of 0.689. A small number (n=45; 0.63%) of the subset of negatives tested were classified by the multiplex assay as either HIV-1 positive (n=35) or HIV-2 positive (n=10). Nevertheless, the HIV Triplex assay agreed with NAIIS HIV-negative survey results (99.37%). Using these results as they were, unweighted estimates of HIV prevalence for both HIV Triplex assay and NAIIS test results were similar (1.62% [95% CI: 1.56-1.68] and 1.60% [95% CI: 1.54-1.66], respectively) with overlapping confidence. After adjusting for viral load and anti-retroviral therapy, HIV-1 unweighted incidence for ages ≥15 years, using HIV Triplex assay data, was 0.70 per 1,000 [95% CI: 0.40-0.90]. This is similar to the unweighted incidence using the LAg-based RITA (recent infection testing algorithm) of 0.80 per 1,000 [95% CI: 0.60-1.10]. The HIV Triplex assay combines several assays in one, providing highly accurate results for estimating HIV prevalence and HIV-1 incidence in surveys. This assay has the potential to simplify cross-sectional surveys making them less expensive, easier, and quicker.
- 9 April 2025
- Published by Public Library of Science (PLoS) in PLOS Global Public Health
- Vol. 5 (4) , e0003455
Open AccessField validation and application of the luminex triplex HIV assay to estimate HIV prevalence and HIV-1 incidence in Nigeria
HIV cross-sectional surveys require multi-layered testing with several tests to estimate HIV prevalence and HIV-1 incidence. We evaluated the performance and accuracy of the newly developed HIV Triplex assay to diagnose HIV-1 and HIV-2 and detect HIV-1 recent infections using plasma samples from the 2018 Nigeria AIDS Indicator and Impact Survey (NAIIS). Plasma samples from consenting HIV-positive (n=2,773) and a subset of HIV-negative samples (n=7,196), as determined by the national rapid testing algorithm, followed by Bio-Rad Geenius HIV-1/2 Supplemental Assay and Western Blot, aged 18 months - 64 years, were tested using the Luminex-based HIV Triplex assay. The assay classified specimens as HIV-1 positive, HIV-2 positive, dual (HIV-1 & 2) infections, or HIV-seronegative. All HIV-1 and dual infections were further classified as either HIV-1 recent (kappa of 0.987 when compared to NAIIS survey results. Percent agreement between the HIV Triplex assay and the LAg-Avidity EIA for recent and LT classification was 98.86% with a kappa of 0.80 [CI: 0.71-0.89] and a Spearman-ranked correlation (ρ) of 0.689. A small number (n=45; 0.63%) of the subset of negatives tested were classified by the multiplex assay as either HIV-1 positive (n=35) or HIV-2 positive (n=10). Nevertheless, the HIV Triplex assay agreed with NAIIS HIV-negative survey results (99.37%). Using these results as they were, unweighted estimates of HIV prevalence for both HIV Triplex assay and NAIIS test results were similar (1.62% [95% CI: 1.56-1.68] and 1.60% [95% CI: 1.54-1.66], respectively) with overlapping confidence. After adjusting for viral load and anti-retroviral therapy, HIV-1 unweighted incidence for ages ≥15 years, using HIV Triplex assay data, was 0.70 per 1,000 [95% CI: 0.40-0.90]. This is similar to the unweighted incidence using the LAg-based RITA (recent infection testing algorithm) of 0.80 per 1,000 [95% CI: 0.60-1.10]. The HIV Triplex assay combines several assays in one, providing highly accurate results for estimating HIV prevalence and HIV-1 incidence in surveys. This assay has the potential to simplify cross-sectional surveys making them less expensive, easier, and quicker.
- Open Access
- 1 January 2025
- Published by AOSIS in African Journal of Laboratory Medicine
- Vol. 14 (1) , 6
Lessons learnt from laboratory capacity building in supporting integrated disease serosurveillance using a multiplex bead assay in Nigeria
Background: Serologic assays can monitor population exposure to pathogens and immunity to vaccine-preventable diseases; the multiplex bead assay (MBA) can test for multiple analytes simultaneously. Intervention: Specimens collected during the Nigeria HIV/AIDS Indicator and Impact Survey (NAIIS) were used to estimate the seroprevalence of diseases of public health importance, and specimens collected from special studies were used to estimate the seroprevalence of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) to improve the surveillance programmes. In 2019, Luminex MAGPIX® instruments were installed at the MBA laboratory in the National Reference Laboratory, Nigeria Centre for Disease Control and Prevention, in Abuja, Nigeria. Dried blood spot specimens from the NAIIS, stored with consent for future testing, were prioritised for testing. Between 2019 and 2022, the National Reference Laboratory MBA laboratory conducted antibody and antigen assays for an estimated 130 000 NAIIS participants, completed two rounds of coronavirus disease 2019 (COVID-19) serosurveys, and validated SARS-CoV-2 serological assays for use in Nigeria. Lessons learnt: The data generated by the MBA laboratory supported funding requests for childhood immunisation and the application of the National Malaria Elimination Programme Global Fund. The MBA results strengthened the National HIV Serial Rapid Testing Algorithm. During the COVID-19 pandemic, the laboratory validated a SARS-CoV-2 MBA, which measured antibodies against three antigens. This multi-target assay was used to complete two additional rounds of the COVID-19 household serosurvey in Nigeria. Recommendations: This strategy of investing in MBA laboratory capacity building could serve as a model for other nations seeking to fortify their public health infrastructure. What this study adds: Nigeria’s integrated disease surveillance capability was boosted through MBA technology.
- 1 January 2025
- Published by AOSIS in African Journal of Laboratory Medicine
- Vol. 14 (1) , 6
Open AccessLessons learnt from laboratory capacity building in supporting integrated disease serosurveillance using a multiplex bead assay in Nigeria
Background: Serologic assays can monitor population exposure to pathogens and immunity to vaccine-preventable diseases; the multiplex bead assay (MBA) can test for multiple analytes simultaneously. Intervention: Specimens collected during the Nigeria HIV/AIDS Indicator and Impact Survey (NAIIS) were used to estimate the seroprevalence of diseases of public health importance, and specimens collected from special studies were used to estimate the seroprevalence of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) to improve the surveillance programmes. In 2019, Luminex MAGPIX® instruments were installed at the MBA laboratory in the National Reference Laboratory, Nigeria Centre for Disease Control and Prevention, in Abuja, Nigeria. Dried blood spot specimens from the NAIIS, stored with consent for future testing, were prioritised for testing. Between 2019 and 2022, the National Reference Laboratory MBA laboratory conducted antibody and antigen assays for an estimated 130 000 NAIIS participants, completed two rounds of coronavirus disease 2019 (COVID-19) serosurveys, and validated SARS-CoV-2 serological assays for use in Nigeria. Lessons learnt: The data generated by the MBA laboratory supported funding requests for childhood immunisation and the application of the National Malaria Elimination Programme Global Fund. The MBA results strengthened the National HIV Serial Rapid Testing Algorithm. During the COVID-19 pandemic, the laboratory validated a SARS-CoV-2 MBA, which measured antibodies against three antigens. This multi-target assay was used to complete two additional rounds of the COVID-19 household serosurvey in Nigeria. Recommendations: This strategy of investing in MBA laboratory capacity building could serve as a model for other nations seeking to fortify their public health infrastructure. What this study adds: Nigeria’s integrated disease surveillance capability was boosted through MBA technology.
- Open Access
- 25 October 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (10) , e0311829
Determination of the mean duration of recent infection and false recency rate for the HIV triplex multiplex bead assay
Background: We developed the HIV Triplex multiplex bead assay to identify and serotype HIV infection with high sensitivity and specificity; and distinguish recent from long-term HIV-1 infections. It can facilitate accurate incidence estimation, while reducing the number of tests and blood collected, which is highly desirable for use in future studies and surveys. Using previously collected, treatment-naive longitudinal seroconversion HIV-1 positive panels and specimens from individuals infected for >12 months, we determined the assay’s mean duration of recent infection (MDRI) and false-recency rate (FRR) respectively, at various mean fluorescent intensity (MFI) cutoffs. Methods: We tested seroconversion specimens (N = 814) from 142 individuals infected with HIV-1 subtypes B, C, or AE, and 1341 cross-sectional specimens from individuals infected >12 months. The MFI cutoffs of 1000 to 2000 were evaluated for recency classification, including an MFI of 1250 corresponding to the limiting antigen avidity enzyme immunoassay (LAg-EIA) cutoff of 1.5 normalized optical density for MDRI and FRR. We used four statistical methods: Methods 1 and 2 used the empirically balanced observation time approach. Method 2 MFI values were raised to power = 1.33, based on a repeated measures model to linearize the relationship between MFI and time points, whereas Method 1 was not linearized. Methods 3 and 4 employed quadratic and linear interpolations for each seroconversion panel. FRR was calculated by dividing the number of specimens misclassified as recent by the total number of specimens tested. Results: MDRI values ranged from 135–146 days at MFI = 1000 to 229–279 days at MFI = 2000 by the 4 methods. FRR varied from 0.15%-1.27% with increasing MFI cutoff. At MFI = 1250, the average MDRI of 4 methods was 169 days and ranged from 159–183 with overlapping 95% CIs and FRR = 0.52%. Conclusion: The HIV Triplex assay demonstrates a longer dynamic range compared to current HIV recency assays with a low FRR for cutoffs examined. With a longer dynamic range and low FRR, the MDRI for recent infection can be extended as appropriate to detect more recent infections, increasing the value of incidence assays benefiting public health surveillance and future surveys.
- 25 October 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (10) , e0311829
Open AccessDetermination of the mean duration of recent infection and false recency rate for the HIV triplex multiplex bead assay
Background: We developed the HIV Triplex multiplex bead assay to identify and serotype HIV infection with high sensitivity and specificity; and distinguish recent from long-term HIV-1 infections. It can facilitate accurate incidence estimation, while reducing the number of tests and blood collected, which is highly desirable for use in future studies and surveys. Using previously collected, treatment-naive longitudinal seroconversion HIV-1 positive panels and specimens from individuals infected for >12 months, we determined the assay’s mean duration of recent infection (MDRI) and false-recency rate (FRR) respectively, at various mean fluorescent intensity (MFI) cutoffs. Methods: We tested seroconversion specimens (N = 814) from 142 individuals infected with HIV-1 subtypes B, C, or AE, and 1341 cross-sectional specimens from individuals infected >12 months. The MFI cutoffs of 1000 to 2000 were evaluated for recency classification, including an MFI of 1250 corresponding to the limiting antigen avidity enzyme immunoassay (LAg-EIA) cutoff of 1.5 normalized optical density for MDRI and FRR. We used four statistical methods: Methods 1 and 2 used the empirically balanced observation time approach. Method 2 MFI values were raised to power = 1.33, based on a repeated measures model to linearize the relationship between MFI and time points, whereas Method 1 was not linearized. Methods 3 and 4 employed quadratic and linear interpolations for each seroconversion panel. FRR was calculated by dividing the number of specimens misclassified as recent by the total number of specimens tested. Results: MDRI values ranged from 135–146 days at MFI = 1000 to 229–279 days at MFI = 2000 by the 4 methods. FRR varied from 0.15%-1.27% with increasing MFI cutoff. At MFI = 1250, the average MDRI of 4 methods was 169 days and ranged from 159–183 with overlapping 95% CIs and FRR = 0.52%. Conclusion: The HIV Triplex assay demonstrates a longer dynamic range compared to current HIV recency assays with a low FRR for cutoffs examined. With a longer dynamic range and low FRR, the MDRI for recent infection can be extended as appropriate to detect more recent infections, increasing the value of incidence assays benefiting public health surveillance and future surveys.
- Open Access
- 15 May 2024
- Published by Public Library of Science (PLoS) in PLOS Global Public Health
- Vol. 4 (5) , e0003195
Continuous quality evaluation of the Asanté rapid test for recent infection for robust kit lot quality verification
The Sedia Biosciences Asanté rapid test for recent infection (RTRI) can identify HIV infections and characterize HIV-1 as recent or long-term infection via the positive verification (V) line and long-term line (LT) line, respectively. Tracking with Recency Assays to Control the Epidemic (TRACE) program uses RTRI assays. Successful implementation of TRACE requires high-quality test performance. The goal of this study is to evaluate the additional quality practices established for new kit lots prior to field use. Asanté lot quality control data from the manufacturer is reviewed by the Centers for Disease Control and Prevention International Laboratory Branch (CDC-ILB) in the Division of Global HIV and TB using. If a lot passes manufacturer quality control and CDC-ILB review, test kits are sent to CDC-ILB for further evaluation. Evaluation by CDC includes inter-rater reliability and linear regressions comparing the V and LT lines against reference data as well as V and LT line data between testers. A Bland-Altman analysis was conducted to assess bias and systematic error. Overall, CDC-ILB passed 29 (91%) out of 32 Sedia Biosciences Asanté kit lots that initially passed manufacturing quality control from July 2017 to May 2020. Regression analyses demonstrate that test kits are performing as expected with consistent R2≥0.92 for both V and LT lines. On average, inter-rater reliability kappa was 0.9, indicating a strong level of agreement. Bland-Altman analyses demonstrate high agreement with little to no systematic error and bias. Ongoing evaluation of new RTRI kit lots is important to ensure high quality test performance. Rejecting 9% of kit lots highlight the importance of continuing to work with manufacturers to ensure consistent kit production and quality assurance (QA) activities. Investing in effective QA measures, conducting both pre- and post-market performance data reviews, could help improve RTRI accuracy and outcomes in similar testing programs.
- 15 May 2024
- Published by Public Library of Science (PLoS) in PLOS Global Public Health
- Vol. 4 (5) , e0003195
Open AccessContinuous quality evaluation of the Asanté rapid test for recent infection for robust kit lot quality verification
The Sedia Biosciences Asanté rapid test for recent infection (RTRI) can identify HIV infections and characterize HIV-1 as recent or long-term infection via the positive verification (V) line and long-term line (LT) line, respectively. Tracking with Recency Assays to Control the Epidemic (TRACE) program uses RTRI assays. Successful implementation of TRACE requires high-quality test performance. The goal of this study is to evaluate the additional quality practices established for new kit lots prior to field use. Asanté lot quality control data from the manufacturer is reviewed by the Centers for Disease Control and Prevention International Laboratory Branch (CDC-ILB) in the Division of Global HIV and TB using. If a lot passes manufacturer quality control and CDC-ILB review, test kits are sent to CDC-ILB for further evaluation. Evaluation by CDC includes inter-rater reliability and linear regressions comparing the V and LT lines against reference data as well as V and LT line data between testers. A Bland-Altman analysis was conducted to assess bias and systematic error. Overall, CDC-ILB passed 29 (91%) out of 32 Sedia Biosciences Asanté kit lots that initially passed manufacturing quality control from July 2017 to May 2020. Regression analyses demonstrate that test kits are performing as expected with consistent R2≥0.92 for both V and LT lines. On average, inter-rater reliability kappa was 0.9, indicating a strong level of agreement. Bland-Altman analyses demonstrate high agreement with little to no systematic error and bias. Ongoing evaluation of new RTRI kit lots is important to ensure high quality test performance. Rejecting 9% of kit lots highlight the importance of continuing to work with manufacturers to ensure consistent kit production and quality assurance (QA) activities. Investing in effective QA measures, conducting both pre- and post-market performance data reviews, could help improve RTRI accuracy and outcomes in similar testing programs.
- Open Access
- 18 May 2022
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 60 (5) , e0234821
Development of a Bead-Based Multiplex Assay for Use in Multianalyte Screening and Surveillance of HIV, Viral Hepatitis, Syphilis, and Herpes
Diagnostic assays that can simultaneously determine the presence of infection with multiple pathogens are key for diagnosis and surveillance. Current multiplex diagnostic assays are complex and often have limited availability.
- 18 May 2022
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 60 (5) , e0234821
Open AccessDevelopment of a Bead-Based Multiplex Assay for Use in Multianalyte Screening and Surveillance of HIV, Viral Hepatitis, Syphilis, and Herpes
Diagnostic assays that can simultaneously determine the presence of infection with multiple pathogens are key for diagnosis and surveillance. Current multiplex diagnostic assays are complex and often have limited availability.