Latest Publications
- Open Access
Demonstration of a Transportable Fabry–Pérot Refractometer by a Ring-Type Comparison of Dead-Weight Pressure Balances at Four European National Metrology Institutes
Fabry–Pérot-based refractometry has demonstrated the ability to assess gas pressure with high accuracy and has been prophesized to be able to realize the SI unit for pressure, the pascal, based on quantum calculations of the molar polarizabilities of gases. So far, the technology has mostly been limited to well-controlled laboratories. However, recently, an easy-to-use transportable refractometer has been constructed. Although its performance has previously been assessed under well-controlled laboratory conditions, to assess its ability to serve as an actually transportable system, a ring-type comparison addressing various well-characterized pressure balances in the 10–90 kPa range at several European national metrology institutes is presented in this work. It was found that the transportable refractometer is capable of being transported and swiftly set up to be operational with retained performance in a variety of environments. The system could also verify that the pressure balances used within the ring-type comparison agree with each other. These results constitute an important step toward broadening the application areas of FP-based refractometry technology and bringing it within reach of various types of stakeholders, not least within industry.
Open AccessDemonstration of a Transportable Fabry–Pérot Refractometer by a Ring-Type Comparison of Dead-Weight Pressure Balances at Four European National Metrology Institutes
Fabry–Pérot-based refractometry has demonstrated the ability to assess gas pressure with high accuracy and has been prophesized to be able to realize the SI unit for pressure, the pascal, based on quantum calculations of the molar polarizabilities of gases. So far, the technology has mostly been limited to well-controlled laboratories. However, recently, an easy-to-use transportable refractometer has been constructed. Although its performance has previously been assessed under well-controlled laboratory conditions, to assess its ability to serve as an actually transportable system, a ring-type comparison addressing various well-characterized pressure balances in the 10–90 kPa range at several European national metrology institutes is presented in this work. It was found that the transportable refractometer is capable of being transported and swiftly set up to be operational with retained performance in a variety of environments. The system could also verify that the pressure balances used within the ring-type comparison agree with each other. These results constitute an important step toward broadening the application areas of FP-based refractometry technology and bringing it within reach of various types of stakeholders, not least within industry.
- Open Access
- 14 April 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (3) , 035003
Thermodynamic effects in a gas modulated Invar-based dual Fabry–Pérot cavity refractometer
By measuring the refractivity and the temperature of a gas, its pressure can be assessed from fundamental principles. The highest performing instruments are based on Fabry–Perot cavities (FPC). Gas modulation refractometry (GAMOR) is a methodology that has the ability to reduce the influence of disturbances to such an extent that high-precision (sub-parts-per-million) assessments of pressure can be made by the use of FPCs of Invar. To allow for high accuracy assessments, it is of importance to assess the uncertainty contribution from the thermodynamic effects that are associated with the gas filling and emptying of the cavity (pV-work). This paper presents a detailed scrutiny of the influence of the gas exchange process on the assessment of gas temperature on an Invar-based dual-FPC (DFPC) instrumentation. It is shown that by virtue of a combination of a number of carefully selected design entities (a small cavity volume with a bore radius of 3 mm, a spacer material with high heat capacitance, large thermal conductivity, and no regions that are connected with low thermal conductance, i.e. no heat islands, and a continuous assessment of temperature of the cavity spacer) the system is not significantly affected by pV-work. Simulations show that 10 s after the filling all temperature gradients in the system are well into the sub-mK range. Experiments support that refractivity assessments initiated after 40 s are not significantly affected by the pV-work. The analysis given in this work indicates that an upper limit for the influence of pV-work on the Invar-based DFPC system using 100 s long gas modulation cycles is 0.5 mK/100 kPa (or 1.8 ppm/100 kPa). Consequently, thermodynamic effects will not be a limiting factor when the Invar-based DFPC GAMOR system is used for assessments of pressure or as a primary pressure standard up to atmospheric pressures.
- 14 April 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (3) , 035003
Open AccessThermodynamic effects in a gas modulated Invar-based dual Fabry–Pérot cavity refractometer
By measuring the refractivity and the temperature of a gas, its pressure can be assessed from fundamental principles. The highest performing instruments are based on Fabry–Perot cavities (FPC). Gas modulation refractometry (GAMOR) is a methodology that has the ability to reduce the influence of disturbances to such an extent that high-precision (sub-parts-per-million) assessments of pressure can be made by the use of FPCs of Invar. To allow for high accuracy assessments, it is of importance to assess the uncertainty contribution from the thermodynamic effects that are associated with the gas filling and emptying of the cavity (pV-work). This paper presents a detailed scrutiny of the influence of the gas exchange process on the assessment of gas temperature on an Invar-based dual-FPC (DFPC) instrumentation. It is shown that by virtue of a combination of a number of carefully selected design entities (a small cavity volume with a bore radius of 3 mm, a spacer material with high heat capacitance, large thermal conductivity, and no regions that are connected with low thermal conductance, i.e. no heat islands, and a continuous assessment of temperature of the cavity spacer) the system is not significantly affected by pV-work. Simulations show that 10 s after the filling all temperature gradients in the system are well into the sub-mK range. Experiments support that refractivity assessments initiated after 40 s are not significantly affected by the pV-work. The analysis given in this work indicates that an upper limit for the influence of pV-work on the Invar-based DFPC system using 100 s long gas modulation cycles is 0.5 mK/100 kPa (or 1.8 ppm/100 kPa). Consequently, thermodynamic effects will not be a limiting factor when the Invar-based DFPC GAMOR system is used for assessments of pressure or as a primary pressure standard up to atmospheric pressures.