Alessio Coser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alessio Coser has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Massimiliano Marini
Department of Cardiology, Santa Chiara Hospital, 38122 Trento, Italy
4 shared publications - Roberto Bonmassari
Department of Cardiology, Santa Chiara Hospital, 38122 Trento, Italy
4 shared publications - Silvia Quintarelli
Department of Cardiology, Santa Chiara Hospital, 38122 Trento, Italy
4 shared publications - Fabrizio Guarracini
Electrophysiology Unit, De Gasperis Cardio Center, Niguarda Hospital, 20162 Milan, Italy
3 shared publications - Marta Martin
Department of Cardiology, S. Chiara Hospital, 38122 Trento, Italy
3 shared publications - Eleonora Bonvicini
Department of Cardiology, Santa Chiara Hospital, 38122 Trento, Italy
2 shared publications
Latest Publications
- Open Access
- 19 August 2025
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 12 (8) , 313
Hybrid Ablation in Atrial Fibrillation: Bridging Mechanistic Understanding and Clinical Practice
Atrial fibrillation (AF), the most prevalent sustained cardiac arrhythmia, poses a significant burden on global morbidity and healthcare expenditure. Although endocardial catheter ablation and surgical ablation are established therapeutic strategies, each exhibits inherent limitations in achieving comprehensive substrate modification. Hybrid ablation therapy, integrating both endocardial and epicardial approaches, aims to overcome these limitations by enabling the more extensive and transmural targeting of arrhythmogenic foci and the complex atrial substrate. This review synthesizes the electrophysiological basis and mechanistic rationale underpinning hybrid AF ablation, highlighting its potential for an enhanced efficacy compared to isolated techniques. Furthermore, it introduces the emerging paradigm of three-dimensional ablation within this evolving field.
- 19 August 2025
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 12 (8) , 313
Open AccessHybrid Ablation in Atrial Fibrillation: Bridging Mechanistic Understanding and Clinical Practice
Atrial fibrillation (AF), the most prevalent sustained cardiac arrhythmia, poses a significant burden on global morbidity and healthcare expenditure. Although endocardial catheter ablation and surgical ablation are established therapeutic strategies, each exhibits inherent limitations in achieving comprehensive substrate modification. Hybrid ablation therapy, integrating both endocardial and epicardial approaches, aims to overcome these limitations by enabling the more extensive and transmural targeting of arrhythmogenic foci and the complex atrial substrate. This review synthesizes the electrophysiological basis and mechanistic rationale underpinning hybrid AF ablation, highlighting its potential for an enhanced efficacy compared to isolated techniques. Furthermore, it introduces the emerging paradigm of three-dimensional ablation within this evolving field.
- Open Access
Subcutaneous Implantable Cardioverter Defibrillator: A Contemporary Overview
The difference between subcutaneous implantable cardioverter defibrillators (S-ICDs) and transvenous ICDs (TV-ICDs) concerns a whole extra thoracic implantation, including a defibrillator coil and pulse generator, without endovascular components. The improved safety profile has allowed the S-ICD to be rapidly taken up, especially among younger patients. Reports of its role in different cardiac diseases at high risk of SCD such as hypertrophic and arrhythmic cardiomyopathies, as well as channelopathies, is increasing. S-ICDs show comparable efficacy, reliability, and safety outcomes compared to TV-ICD. However, some technical issues (i.e., the inability to perform anti-bradycardia pacing) strongly limit the employment of S-ICDs. Therefore, it still remains only an alternative to the traditional ICD thus far. This review aims to provide a contemporary overview of the role of S-ICDs compared to TV-ICDs in clinical practice, including technical aspects regarding device manufacture and implantation techniques. Newer outlooks and future perspectives of S-ICDs are also brought up to date.
Open AccessSubcutaneous Implantable Cardioverter Defibrillator: A Contemporary Overview
The difference between subcutaneous implantable cardioverter defibrillators (S-ICDs) and transvenous ICDs (TV-ICDs) concerns a whole extra thoracic implantation, including a defibrillator coil and pulse generator, without endovascular components. The improved safety profile has allowed the S-ICD to be rapidly taken up, especially among younger patients. Reports of its role in different cardiac diseases at high risk of SCD such as hypertrophic and arrhythmic cardiomyopathies, as well as channelopathies, is increasing. S-ICDs show comparable efficacy, reliability, and safety outcomes compared to TV-ICD. However, some technical issues (i.e., the inability to perform anti-bradycardia pacing) strongly limit the employment of S-ICDs. Therefore, it still remains only an alternative to the traditional ICD thus far. This review aims to provide a contemporary overview of the role of S-ICDs compared to TV-ICDs in clinical practice, including technical aspects regarding device manufacture and implantation techniques. Newer outlooks and future perspectives of S-ICDs are also brought up to date.
- Open Access
Emergency Management of Electrical Storm: A Practical Overview
Electrical storm is a medical emergency characterized by ventricular arrythmia recurrence that can lead to hemodynamic instability. The incidence of this clinical condition is rising, mainly in implantable cardioverter defibrillator patients, and its prognosis is often poor. Early acknowledgment, management and treatment have a key role in reducing mortality in the acute phase and improving the quality of life of these patients. In an emergency setting, several measures can be employed. Anti-arrhythmic drugs, based on the underlying disease, are often the first step to control the arrhythmic burden; besides that, new therapeutic strategies have been developed with high efficacy, such as deep sedation, early catheter ablation, neuraxial modulation and mechanical hemodynamic support. The aim of this review is to provide practical indications for the management of electrical storm in acute settings.
Open AccessEmergency Management of Electrical Storm: A Practical Overview
Electrical storm is a medical emergency characterized by ventricular arrythmia recurrence that can lead to hemodynamic instability. The incidence of this clinical condition is rising, mainly in implantable cardioverter defibrillator patients, and its prognosis is often poor. Early acknowledgment, management and treatment have a key role in reducing mortality in the acute phase and improving the quality of life of these patients. In an emergency setting, several measures can be employed. Anti-arrhythmic drugs, based on the underlying disease, are often the first step to control the arrhythmic burden; besides that, new therapeutic strategies have been developed with high efficacy, such as deep sedation, early catheter ablation, neuraxial modulation and mechanical hemodynamic support. The aim of this review is to provide practical indications for the management of electrical storm in acute settings.
- Open Access
- 15 April 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (4) , 994
Programming Optimization in Implantable Cardiac Monitors to Reduce False-Positive Arrhythmia Alerts: A Call for Research
No studies have investigated whether optimizing implantable cardiac monitors (ICM) programming can reduce false-positive (FP) alerts. We identified patients implanted with an ICM (BIOMONITOR III) who had more than 10 FP alerts in a 1-month retrospective period. Uniform adjustments of settings were performed based on the mechanism of FP triggers and assessed at 1 month. Eight patients (mean age 57.5 ± 23.2 years; 37% female) were enrolled. In 4 patients, FPs were caused by undersensing of low-amplitude premature ventricular contractions (PVCs). No further false bradycardia was observed with a more aggressive decay of the dynamic sensing threshold. Furthermore, false atrial fibrillation (AF) alerts decreased in 2 of 3 patients. Two patients had undersensing of R waves after high-amplitude PVCs; false bradycardia episodes disappeared or were significantly reduced by limiting the initial value of the sensing threshold. Finally, the presence of atrial ectopic activity or irregular sinus rhythm generated false alerts of AF in 2 patients that were reduced by increasing the R-R variability limit and the confirmation time. In conclusion, adjustments to nominal settings can reduce the number of FP episodes in ICM patients. More research is needed to provide practical recommendations and assess the value of extended ICM programmability.
- 15 April 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (4) , 994
Open AccessProgramming Optimization in Implantable Cardiac Monitors to Reduce False-Positive Arrhythmia Alerts: A Call for Research
No studies have investigated whether optimizing implantable cardiac monitors (ICM) programming can reduce false-positive (FP) alerts. We identified patients implanted with an ICM (BIOMONITOR III) who had more than 10 FP alerts in a 1-month retrospective period. Uniform adjustments of settings were performed based on the mechanism of FP triggers and assessed at 1 month. Eight patients (mean age 57.5 ± 23.2 years; 37% female) were enrolled. In 4 patients, FPs were caused by undersensing of low-amplitude premature ventricular contractions (PVCs). No further false bradycardia was observed with a more aggressive decay of the dynamic sensing threshold. Furthermore, false atrial fibrillation (AF) alerts decreased in 2 of 3 patients. Two patients had undersensing of R waves after high-amplitude PVCs; false bradycardia episodes disappeared or were significantly reduced by limiting the initial value of the sensing threshold. Finally, the presence of atrial ectopic activity or irregular sinus rhythm generated false alerts of AF in 2 patients that were reduced by increasing the R-R variability limit and the confirmation time. In conclusion, adjustments to nominal settings can reduce the number of FP episodes in ICM patients. More research is needed to provide practical recommendations and assess the value of extended ICM programmability.