Kangfei Lv
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kangfei Lv has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Cong Zhu
School of Electrical Engineering, China University of Mining and Technology, Xuzhou 221008, China
1 shared publication Heng Nian
College of Electrical Engineering, Zhejiang University Hangzhou 310027 Zhejiang People's Republic of China
1 shared publicationLili Liu
School of Mechanical Electrical Engineering, Xuzhou University of Technology Xuzhou 221018 Jiangsu People's Republic of China
1 shared publication- Xinwei Dong
School of Electrical Engineering, China University of Mining and Technology, Xuzhou 221008, China
1 shared publication Xiwei Dong
School of Electrical and Power Engineering China University of Mining and Technology Xuzhou 221166 Jiangsu People's Republic of China
1 shared publication
Latest Publications
- Open Access
Research on Fault-Tolerant Operation Strategy of Permanent Magnet Synchronous Motor with Common DC Bus Open Winding Phase-Breaking Fault
In some key areas, fault-tolerant control is usually needed in order to enable the motor to operate continuously in fault mode. Given that it is difficult to detect the zero-sequence current of the open winding permanent magnet synchronous motor after the phase break fault occurs, the traditional zero-sequence current suppression strategy is no longer applicable after the phase break fault occurs. Therefore, a zero-sequence current suppression strategy for a common DC bus under a phase break fault is proposed in this paper. By establishing the mathematical model between the current component in the synchronous coordinate system and the current component and the zero-sequence current in the static coordinate system, the relationship between the non-fault phase current and the zero-sequence current in the open phase fault is analyzed. A method of suppressing the zero-sequence current by using proportional integral double resonance in a zero-sequence current control loop is proposed. In addition, according to the large number of calculations in traditional space vector modulation (SVPWM)—such as sector judgment and coordinate transformation—a decoupling modulation algorithm is proposed to modulate the reference voltage vector. Finally, the experimental platform for the common DC bus open winding permanent magnet synchronous motor is built, and the zero-sequence current suppression method for the common DC bus OW-PMSM under phase break fault is verified experimentally.
Open AccessResearch on Fault-Tolerant Operation Strategy of Permanent Magnet Synchronous Motor with Common DC Bus Open Winding Phase-Breaking Fault
In some key areas, fault-tolerant control is usually needed in order to enable the motor to operate continuously in fault mode. Given that it is difficult to detect the zero-sequence current of the open winding permanent magnet synchronous motor after the phase break fault occurs, the traditional zero-sequence current suppression strategy is no longer applicable after the phase break fault occurs. Therefore, a zero-sequence current suppression strategy for a common DC bus under a phase break fault is proposed in this paper. By establishing the mathematical model between the current component in the synchronous coordinate system and the current component and the zero-sequence current in the static coordinate system, the relationship between the non-fault phase current and the zero-sequence current in the open phase fault is analyzed. A method of suppressing the zero-sequence current by using proportional integral double resonance in a zero-sequence current control loop is proposed. In addition, according to the large number of calculations in traditional space vector modulation (SVPWM)—such as sector judgment and coordinate transformation—a decoupling modulation algorithm is proposed to modulate the reference voltage vector. Finally, the experimental platform for the common DC bus open winding permanent magnet synchronous motor is built, and the zero-sequence current suppression method for the common DC bus OW-PMSM under phase break fault is verified experimentally.
- Open Access
- 1 May 2020
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 56 (11) , 563-565
Fault‐tolerant control strategy with reduced switching frequency for inverter‐based fault in open‐winding PMSM system
The open‐winding permanent magnet synchronous machine (OW‐PMSM) system is widely investigated for its potential fault tolerance while extra switching loss is inevitable due to the doubled switch devices. Hence, to further improve its performance, a fault‐tolerant control strategy against the inverter‐based fault, in which the corresponding terminal of the phase winding is connected with the mid‐point of the two capacitances in parallel to the dc voltage, is proposed in this Letter. In the proposed method, the reference voltages are modulated under the three‐phase stationary coordinate system, considering the voltage fluctuation of the capacitances. In addition, to reduce the switching frequency, the reference voltages are adjusted synchronously, according to the polarity of the reference voltages. Moreover, the effective modulation range of the proposed method is analysed. Finally, the performance of the proposed strategy is validated experimentally.
- 1 May 2020
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 56 (11) , 563-565
Open AccessFault‐tolerant control strategy with reduced switching frequency for inverter‐based fault in open‐winding PMSM system
The open‐winding permanent magnet synchronous machine (OW‐PMSM) system is widely investigated for its potential fault tolerance while extra switching loss is inevitable due to the doubled switch devices. Hence, to further improve its performance, a fault‐tolerant control strategy against the inverter‐based fault, in which the corresponding terminal of the phase winding is connected with the mid‐point of the two capacitances in parallel to the dc voltage, is proposed in this Letter. In the proposed method, the reference voltages are modulated under the three‐phase stationary coordinate system, considering the voltage fluctuation of the capacitances. In addition, to reduce the switching frequency, the reference voltages are adjusted synchronously, according to the polarity of the reference voltages. Moreover, the effective modulation range of the proposed method is analysed. Finally, the performance of the proposed strategy is validated experimentally.