JKJackson W. Kiser

Jackson W. Kiser

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jackson W. Kiser has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Clinical Theranostics in Recurrent Gliomas: A Review

    by Austin R. Hoggarth, Sankar Muthukumar, Steven M. Thomas, James Crowley, Jackson Kiser, Mark R. Witcher

    Gliomas represent the most commonly occurring tumors in the central nervous system and account for approximately 80% of all malignant primary brain tumors. With a high malignancy and recurrence risk, the prognosis of high-grade gliomas is poor, with a mean survival time of 12–18 months. While contrast-enhanced MRI serves as the standard diagnostic imaging modality for gliomas, it faces limitations in the evaluation of recurrent gliomas, failing to distinguish between treatment-related changes and tumor progression, and offers no direct therapeutic options. Recent advances in imaging modalities have attempted to address some of these limitations, including positron emission tomography (PET), which has demonstrated success in delineating tumor margins and guiding the treatment of recurrent gliomas. Additionally, with the advent of theranostics in nuclear medicine, PET tracers, when combined with therapeutic agents, have also evolved beyond a purely diagnostic modality, serving both diagnostic and therapeutic roles. This review will discuss the growing involvement of theranostics in diagnosing and treating recurrent gliomas and address the associated impact on quality of life and functional recovery.


  • Open Access

    Case Report: Radiopharmaceutical extravasation, radiation paranoia, and chilling effect

    by Jason Mace, Jackson W. Kiser

    The Society of Nuclear Medicine and Molecular Imaging (SNMMI) has publicly commented that they do not support the reporting of large extravasations to patients or regulatory bodies. The comment cites recently published articles suggesting that extravasations are infrequent and not severe. The comment stresses the importance of ensuring patients are not apprehensive or resistant to nuclear medicine procedures because of “radiation paranoia” and a “chilling effect” that can result from misinformation. Radiation paranoia and chilling effect are not defined, and there are no references to specific misinformation. Our experiences and this case suggest the comment may be incongruent with real-world clinical experiences. Our severe case, at a center with a long-standing focus on reducing radiopharmaceutical extravasation, suggests these events can still happen, can be significant, and should be shared with our patients. Our experiences also suggest that being transparent with patients builds trust. We are concerned that a reluctance to recognize the true frequency of extravasations and their severity may create distrust in the relationship between the nuclear medicine community and patients.

  • Open Access

    The decision to reimage following extravasation in diagnostic nuclear medicine

    by Jackson W. Kiser

    The primary goal of diagnostic nuclear medicine is to provide complete and accurate reports without equivocation or disclaimers. If specific clinical questions cannot be answered because of radiopharmaceutical extravasation, the imaging study may have to be repeated. The decision to reimage is based on several factors including the diagnostic quality of the images, additional patient radiation dose, patient burden, and administrative constraints. Through process improvement efforts, nuclear medicine departments can significantly reduce the frequency of extravasation and thereby also the need for reimaging. Communication with the patient is important any time extravasation may impact their immediate or future care. The circumstances and potential ramifications should be explained, and patient concerns should be addressed. Although recent arguments have been made in favor of investigating and addressing only those extravasations which result in serious patient injury, patients and their referring physicians deserve to know any time their nuclear medicine study may have been impacted.


  • Open Access

    Active monitoring improves radiopharmaceutical administration quality

    by James R. Crowley, Iryna Barvi, Jackson W. Kiser

    Introduction: In 2016, our center adopted technology to routinely monitor 18F-FDG radiopharmaceutical administrations. Within six months of following basic quality improvement methodology, our technologists reduced extravasation rates from 13.3% to 2.9% (p < 0.0001). These same technologists administer other radiopharmaceuticals (without monitoring technology) for general nuclear medicine procedures in a separate facility at the clinic. Our hypothesis was that they would apply 18F-FDG lessons-learned to 99mTc-MDP administrations and that 99mTc-MDP manual injection extravasation rate would be consistent with the ongoing 18F-FDG manual injection extravasation rate (3.4%). We tested our hypothesis by following the same quality improvement methodology and added monitoring equipment to measure extravasation rates for 99mTc-MDP administrations.Results: 816 99mTc-MDP administrations were monitored during 16-month period (four 4-month periods: A, B, C, D). Period A (first four months of active monitoring) extravasation rate was not statistically different from the Measure Phase extravasation rate of the previously completed PET/CT QI Project: 12.75% compared to 13.3% (p-0.7925). Period A extravasation rate was statistically different from Period C (months 9–12) extravasation rate and Period D (months 13–16) extravasation rate: 12.75% compared to 2.94% and to 3.43% (p < 0.0001). During Period C and D technologists achieved extravasation rates comparable to the longstanding manual 18F-FDG injection extravasation rate (3.4%).Conclusion: Our initial hypothesis, that awareness of a problem and the steps need to correct it would result in process improvement, was not accurate. While those factors are important, they are not sufficient. Our findings suggest that active monitoring and the associated display of results are critical to quality improvement efforts to reduce and sustain radiopharmaceutical extravasation rates.


  • Open Access

    A Comparison of PET Tracers in Recurrent High-Grade Gliomas: A Systematic Review

    by Sankar Muthukumar, Jordan Darden, James Crowley, Mark Witcher, Jackson Kiser

    Humans with high-grade gliomas have a poor prognosis, with a mean survival time of just 12–18 months for patients who undergo standard-of-care tumor resection and adjuvant therapy. Currently, surgery and chemoradiotherapy serve as standard treatments for this condition, yet these can be complicated by the tumor location, growth rate and recurrence. Currently, gadolinium-based, contrast-enhanced magnetic resonance imaging (CE-MRI) serves as the predominant imaging modality for recurrent high-grade gliomas, but it faces several drawbacks, including its inability to distinguish tumor recurrence from treatment-related changes and its failure to reveal the entirety of tumor burden (de novo or recurrent) due to limitations inherent to gadolinium contrast. As such, alternative imaging modalities that can address these limitations, including positron emission tomography (PET), are worth pursuing. To this end, the identification of PET-based markers for use in imaging of recurrent high-grade gliomas is paramount. This review will highlight several PET radiotracers that have been implemented in clinical practice and provide a comparison between them to assess the efficacy of these tracers.


  • A Request for Scientific Accountability in Public Statements

    by David Townsend, Jackson W. Kiser, Marjan Boerma, Daniel Fass, Sean Ms Wilson, Daniel Sullivan

    An abstract is unavailable. This article is available as a PDF only.

  • Open Access

    Prostate-Specific Membrane Antigen as Target for Neuroimaging of Central Nervous System Tumors

    by Brittany M. Stopa, James Crowley, Csaba Juhász, Cara M. Rogers, Mark R. Witcher, Jackson W. Kiser

    Introduction. Positron emission tomography (PET) imaging with prostate-specific membrane antigen- (PSMA-) binding tracers has been found incidentally to demonstrate uptake in CNS tumors. Following the encouraging findings of several such case reports, there is a growing interest in the potential application of PSMA-targeted PET imaging for diagnostics, theranostics, and monitoring of CNS tumors. This is a systematic literature review on PSMA-binding tracers in CNS tumors. Methods. A PubMed search was conducted, including preclinical and clinical reports. One hundred and twelve records were identified, and after screening, 56 were included in the final report. Results. Tissue studies demonstrated PSMA expression in tumor vascular endothelial cells, without expression in normal brain tissue, though the extent and intensity of staining varied by anti-PSMA antibody and methodology. Most included studies reported on gliomas, which showed strong PSMA ligand uptake and more favorable tumor to background ratios than other PET tracers. There are also case reports demonstrating PSMA ligand uptake in prostate cancer brain metastases, nonprostate cancer brain metastases, and meningiomas. We also review the properties of the various PSMA-binding radiotracers available. Therapeutic and theranostic applications of PSMA-binding tracers have been studied, including labeled alpha- and beta-ray emitting isotopes, as well as PSMA targeting in directing MRI-guided focused ultrasound. Conclusions. There is a potential application for PSMA-targeted PET in neuro-oncology as a combination of diagnostic and therapeutic use, as a theranostic modality for managing CNS tumors. Further research is needed regarding the mechanism(s) of PSMA expression in CNS tumors and its differential performance by tumor type.


  • Open Access

    Detection of Excess Presence of 99mTc-MDP Near Injection Site—A Case Report

    by James R. Crowley, Iryna Barvi, Debbie Greulich, Jackson W. Kiser

    Nuclear medicine extravasations and prolonged venous stasis may cause poor quality and quantification errors that can affect image interpretation and patient management. Radiopharmaceutical remaining near the administration site means that some portion of the radioactivity is not circulating as required for the prescribed uptake period. This case describes how detection of excess presence of99mTc-MDP near the injection site enabled the technologist to apply mitigation tactics early in the uptake process. It also suggests that detecting an extravasation or stasis early in the injection process can be important for image interpretation and minimizing radiation dose to tissue.


  • Open Access

    Patient-specific Extravasation Dosimetry Using Uptake Probe Measurements

    by Dustin Osborne, Jackson W. Kiser, Josh Knowland, David Townsend, Darrell R. Fisher

    Extravasation is a common problem in radiopharmaceutical administration and can result in significant radiation dose to underlying tissue and skin. The resulting radiation effects are rarely studied and should be more fully evaluated to guide patient care and meet regulatory obligations. The purpose of this work was to show that a dedicated radiopharmaceutical injection monitoring system can help clinicians characterize extravasations for calculating tissue and skin doses. We employed a commercially available radiopharmaceutical injection monitoring system to identify suspected extravasation of 18F-fluorodeoxyglucose and 99mTc-methylene diphosphonate in 26 patients and to characterize their rates of biological clearance. We calculated the self-dose to infiltrated tissue using Monte Carlo simulation and standard MIRD dosimetry methods, and we used VARSKIN software to calculate the shallow dose equivalent to the epithelial basal-cell layer of overlying skin. For 26 patients, injection-site count rate data were used to characterize extravasation clearance. For each, the absorbed dose was calculated using representative tissue geometries. Resulting tissue-absorbed doses ranged from 0.6 to 11.2 Gy, and the shallow dose equivalent to a 10 cm2 area of adjacent skin in these patients ranged from about 0.1 to 5.4 Sv. Extravasated injections of radiopharmaceuticals can result in unintentional doses that exceed well-established radiation protection and regulatory limits; they should be identified and characterized. An external injection monitoring system may help to promptly identify and characterize extravasations and improve dosimetry calculations. Patient-specific characterization can help clinicians determine extravasation severity and whether the patient should be followed for adverse tissue reactions that may present later in time.


  • Open Access

    Assessing and Reducing Positron Emission Tomography/Computed Tomography Radiotracer Infiltrations: Lessons in Quality Improvement and Sustainability

    by Jackson W. Kiser, Thad Benefield, Ronald K. Lattanze, Kelley A. Ryan, James Crowley

    PURPOSE:Accurate administration of radiotracer dose is essential to positron emission tomography (PET) image quality and quantification. Misadministration (infiltration) of the dose can affect PET/computed tomography results and lead to unnecessary or inappropriate treatments and procedures. Quality control efforts ensure accuracy of the administered dose; however, they fail to ensure complete delivery of the dose into the patient's circulation. We used new technology to assess and improve infiltration rates and evaluate sustainability.METHODS:Injection quality was measured, improved, and sustained during our participation in a multicenter quality improvement project using Define, Measure, Analyze, Improve, Control methodology. Five technologists monitored injection quality in the Measure and Improve phases. After seven new technologists joined the team in the Control phase, infiltration rates were recalculated, controlling for technologist- and patient-level correlations, and comparisons were made between these two groups of technologists.RESULTS:In the Measure phase, five technologists monitored 263 injections (13.3% infiltration rate). Nonantecubital fossa injections had a higher probability of infiltration than antecubital fossa injections. After implementing a quality improvement plan (QIP), the same technologists monitored 278 injections in the Improve phase (2.9% infiltration rate). The 78% decrease in infiltration rate was significant (P < .001) as was the decrease in nonantecubital fossa infiltrations (P = .0025). In the Control phase, 12 technologists monitored 1,240 injections (3.1% infiltration rate). The seven new technologists had significantly higher rates of infiltration (P = .017).CONCLUSION:A QIP can significantly improve and sustain injection quality; however, ongoing monitoring is needed as new technologists join the team.