Gongquan Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gongquan Sun has a total of 237 co-authors. Here are the top co-authors by number of shared publications:
Zhangxun Xia
Chinese Academy of Sciences
41 shared publicationsSuli Wang
34 shared publications- Suli Wang
Division of Fuel Cells and Battery, Dalian National Laboratory for Clean Energy, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
29 shared publications Huanqiao Li
Division of Fuel Cells and Battery, Dalian National Laboratory for Clean Energy, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
21 shared publicationsXiaoming Zhang
Division of Fuel Cells and Battery, Dalian National Laboratory for Clean Energy, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
20 shared publicationsLuhua Jiang
Division of Fuel Cell and Battery, Dalian National Laboratory for Clean Energy, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
18 shared publications
Latest Publications
- 31 October 2026
- Published by American Chemical Society (ACS) in ACS Applied Engineering Materials
Hydrophilicity-Regulated Graded Interfacial Engineering for Anion Exchange Membrane Fuel Cells
The insufficient durability of anion exchange membrane fuel cells (AEMFCs) remains a major barrier to their practical application. Water management is one of the critical factors governing AEMFC performance and durability. Insufficient hydration at the cathode catalyst layer and the membrane interface is considered to mainly restrict the durability of AEMFCs. To address this limitation, a super hydrophilic ionomer coating was directly introduced onto the membrane surface to construct a hydrophilicity-regulated, locally water-retentive interfacial region. Benefiting from the high water uptake of QPCBP-10 (381% at 20 °C and 451% at 90 °C), the coating formed a locally water-retentive gradient region at the cathode catalyst layer and the membrane interface, building up a good reaction micro-environment. The coating loading was optimized to balance interfacial humidification, kinetic polarization, and mass-transport polarization, with an optimal loading of 0.155 mg cm−2. During the durability testing at 300 mA cm−2 and 80 °C, the coated membrane electrode assembly (MEA) showed a voltage decay rate of 3.69 mV h−1, compared with 8.17 mV h−1 for the uncoated baseline MEA, corresponding to a 55% reduction. The time-normalized charge-transfer-resistance growth rate decreased from 0.0477 to 0.0187 Ω cm2 h−1. This work provides a targeted hydrophilicity-regulated interfacial engineering strategy for localized water management and improved operational durability of AEMFCs.
- 31 October 2026
- Published by American Chemical Society (ACS) in ACS Applied Engineering Materials
Hydrophilicity-Regulated Graded Interfacial Engineering for Anion Exchange Membrane Fuel Cells
The insufficient durability of anion exchange membrane fuel cells (AEMFCs) remains a major barrier to their practical application. Water management is one of the critical factors governing AEMFC performance and durability. Insufficient hydration at the cathode catalyst layer and the membrane interface is considered to mainly restrict the durability of AEMFCs. To address this limitation, a super hydrophilic ionomer coating was directly introduced onto the membrane surface to construct a hydrophilicity-regulated, locally water-retentive interfacial region. Benefiting from the high water uptake of QPCBP-10 (381% at 20 °C and 451% at 90 °C), the coating formed a locally water-retentive gradient region at the cathode catalyst layer and the membrane interface, building up a good reaction micro-environment. The coating loading was optimized to balance interfacial humidification, kinetic polarization, and mass-transport polarization, with an optimal loading of 0.155 mg cm−2. During the durability testing at 300 mA cm−2 and 80 °C, the coated membrane electrode assembly (MEA) showed a voltage decay rate of 3.69 mV h−1, compared with 8.17 mV h−1 for the uncoated baseline MEA, corresponding to a 55% reduction. The time-normalized charge-transfer-resistance growth rate decreased from 0.0477 to 0.0187 Ω cm2 h−1. This work provides a targeted hydrophilicity-regulated interfacial engineering strategy for localized water management and improved operational durability of AEMFCs.
- 11 June 2026
- Published by Royal Society of Chemistry (RSC) in Sustainable Energy & Fuels
- Vol. 10 (14) , 3430-3440
Coordination engineering of Ru–N-C based OER catalysts guided by the Δ G *OH descriptor: a theoretical study
A Δ G *OH guided framework maps the activity-stability landscape of Ru–N–C OER catalysts. Ru–NiN 4 and RuIr–O3R emerge as top candidates, while operando simulations reveal *O-induced destabilization as the key durability bottleneck.
- 11 June 2026
- Published by Royal Society of Chemistry (RSC) in Sustainable Energy & Fuels
- Vol. 10 (14) , 3430-3440
Coordination engineering of Ru–N-C based OER catalysts guided by the Δ G *OH descriptor: a theoretical study
A Δ G *OH guided framework maps the activity-stability landscape of Ru–N–C OER catalysts. Ru–NiN 4 and RuIr–O3R emerge as top candidates, while operando simulations reveal *O-induced destabilization as the key durability bottleneck.
- Open Access
- 2 May 2026
- Published by Elsevier in SSRN Electronic Journal
Methanol-Tolerant and Durable PtFeCoNiMo High-Entropy Nanoalloy Electrocatalyst for Efficient Oxygen Reduction in Direct Methanol Fuel Cells
To address cathode poisoning caused by methanol crossover and insufficient durability in direct methanol fuel cells (DMFCs), a PtFeCoNiMo/C high-entropy nanoalloy (HEA) catalyst was synthesized via a one-pot solvothermal reduction method, and the effect of Mo incorporation on its structure and electrocatalytic performance was investigated. The catalyst exhibited outstanding oxygen reduction reaction (ORR) activity, delivering a half-wave potential of 0.868 V and a specific activity of 1.03 mA cmPt-2 at 0.90 V, which was 5.9 times that of commercial 20 wt.% Pt/C catalyst. After 30,000 accelerated durability test (ADT) cycles, the catalyst showed only a 10 mV loss in half-wave potential. Upon the addition 0.1 M CH3OH to the electrolyte, the methanol oxidation peak and current of PtFeCoNiMo/C were both much lower than those of commercial Pt/C. These results suggest that the introduction of a small amount of Mo is beneficial for balancing activity, methanol tolerance, and stability of Pt-based high-entropy alloy catalysts, making PtFeCoNiMo/C a promising candidates for ORR catalysis at the DMFC cathode.
- 2 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMethanol-Tolerant and Durable PtFeCoNiMo High-Entropy Nanoalloy Electrocatalyst for Efficient Oxygen Reduction in Direct Methanol Fuel Cells
To address cathode poisoning caused by methanol crossover and insufficient durability in direct methanol fuel cells (DMFCs), a PtFeCoNiMo/C high-entropy nanoalloy (HEA) catalyst was synthesized via a one-pot solvothermal reduction method, and the effect of Mo incorporation on its structure and electrocatalytic performance was investigated. The catalyst exhibited outstanding oxygen reduction reaction (ORR) activity, delivering a half-wave potential of 0.868 V and a specific activity of 1.03 mA cmPt-2 at 0.90 V, which was 5.9 times that of commercial 20 wt.% Pt/C catalyst. After 30,000 accelerated durability test (ADT) cycles, the catalyst showed only a 10 mV loss in half-wave potential. Upon the addition 0.1 M CH3OH to the electrolyte, the methanol oxidation peak and current of PtFeCoNiMo/C were both much lower than those of commercial Pt/C. These results suggest that the introduction of a small amount of Mo is beneficial for balancing activity, methanol tolerance, and stability of Pt-based high-entropy alloy catalysts, making PtFeCoNiMo/C a promising candidates for ORR catalysis at the DMFC cathode.
- 7 April 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 13 (20) , 14672-14680
Rh single-atom catalysts with optimized metal loading for direct CO-feed high-temperature proton exchange membrane fuel cells
The presence of carbon monoxide (CO) in crude hydrogen is a significant factor hindering the commercialization of hydrogen fuel cells. Introducing a direct CO fuel cell upstream can selectively oxidize and remove CO from crude hydrogen, thereby releasing electrical energy. The purified crude hydrogen is then fed into the downstream hydrogen fuel cell, which helps mitigate the poisoning effect on platinum (Pt) catalysts. Rhodium (Rh) and iridium (Ir) based single-atom catalysts (SACs) have demonstrated potential in the electrochemical CO oxidation reaction (COOR). However, the low density of SAC active sites (Rh metal loading −2 of CO oxidation gradually decreased, while the limiting current density gradually increased, indicating the high COOR activity on the SAC with a higher metal loading. The optimum Rh metal loading was determined to be 2.88 wt% and the limiting current density was found to be 2.4 mA cm−2 with a mass activity of up to 4.18 A mgRh −1. Furthermore, a peak power density of 208.4 mW cm−2 was achieved in a high-temperature single cell utilizing direct CO feed, thereby demonstrating a stable performance over a 22-hours period. This finding indicates a potential robust CO removal capability.
- 7 April 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 13 (20) , 14672-14680
Rh single-atom catalysts with optimized metal loading for direct CO-feed high-temperature proton exchange membrane fuel cells
The presence of carbon monoxide (CO) in crude hydrogen is a significant factor hindering the commercialization of hydrogen fuel cells. Introducing a direct CO fuel cell upstream can selectively oxidize and remove CO from crude hydrogen, thereby releasing electrical energy. The purified crude hydrogen is then fed into the downstream hydrogen fuel cell, which helps mitigate the poisoning effect on platinum (Pt) catalysts. Rhodium (Rh) and iridium (Ir) based single-atom catalysts (SACs) have demonstrated potential in the electrochemical CO oxidation reaction (COOR). However, the low density of SAC active sites (Rh metal loading −2 of CO oxidation gradually decreased, while the limiting current density gradually increased, indicating the high COOR activity on the SAC with a higher metal loading. The optimum Rh metal loading was determined to be 2.88 wt% and the limiting current density was found to be 2.4 mA cm−2 with a mass activity of up to 4.18 A mgRh −1. Furthermore, a peak power density of 208.4 mW cm−2 was achieved in a high-temperature single cell utilizing direct CO feed, thereby demonstrating a stable performance over a 22-hours period. This finding indicates a potential robust CO removal capability.
- 18 October 2024
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 48 (45) , 19241-19248
Insights into (Mn/Fe/Co)M–N–C dual-atom catalysts for the oxygen reduction reaction: the critical role of structural evolution
Dual-atom catalysts (DACs) based on M1M2–N–C have been utilised to regulate the active site of single-atom catalysts (SACs) and optimise their oxygen reduction reaction (ORR) activity.
- 18 October 2024
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 48 (45) , 19241-19248
Insights into (Mn/Fe/Co)M–N–C dual-atom catalysts for the oxygen reduction reaction: the critical role of structural evolution
Dual-atom catalysts (DACs) based on M1M2–N–C have been utilised to regulate the active site of single-atom catalysts (SACs) and optimise their oxygen reduction reaction (ORR) activity.
- 22 August 2024
- Published by Wiley in Energy Technology
- Vol. 12 (11) , 2401075
A Shared Anode Flow Field for Direct Methanol Fuel Cell with Enhanced Performance and Decreased Volume
Low‐volume power density remains a significant barrier to the portable application of direct methanol fuel cell (DMFC). Herein, a shared anode flow field (SAFF) structure is introduced in an active DMFC to reduce stack volume and improve discharge performance. The differences in discharge performance between the bi‐cell with SAFF and the bi‐cell with traditional anode flow field (TAFF), coupled with the effect of operating conditions on performance, are investigated by polarization curve, electrochemical impedance spectra, and voltage versus time curves. The results show that the SAFF structure enhances anode mass transfer, resulting in an improvement in peak power density and voltage stability of the bi‐cell compared to the TAFF structure. In addition, the bi‐cell with SAFF achieves its highest peak power density at a lower methanol concentration, alleviating the methanol crossover caused by high concentration. The SAFF structure is an attractive choice for DMFC portable applications.
- 22 August 2024
- Published by Wiley in Energy Technology
- Vol. 12 (11) , 2401075
A Shared Anode Flow Field for Direct Methanol Fuel Cell with Enhanced Performance and Decreased Volume
Low‐volume power density remains a significant barrier to the portable application of direct methanol fuel cell (DMFC). Herein, a shared anode flow field (SAFF) structure is introduced in an active DMFC to reduce stack volume and improve discharge performance. The differences in discharge performance between the bi‐cell with SAFF and the bi‐cell with traditional anode flow field (TAFF), coupled with the effect of operating conditions on performance, are investigated by polarization curve, electrochemical impedance spectra, and voltage versus time curves. The results show that the SAFF structure enhances anode mass transfer, resulting in an improvement in peak power density and voltage stability of the bi‐cell compared to the TAFF structure. In addition, the bi‐cell with SAFF achieves its highest peak power density at a lower methanol concentration, alleviating the methanol crossover caused by high concentration. The SAFF structure is an attractive choice for DMFC portable applications.
- 18 April 2024
- Published by American Chemical Society (ACS) in ACS Energy Letters
- Vol. 9 (5) , 2257-2264
Conquering Heavy-Loading Decay of High-Temperature Polymer Electrolyte Membrane Fuel Cells with a Conductive Polymer-Based Phosphoric Acid Reservoir
- 18 April 2024
- Published by American Chemical Society (ACS) in ACS Energy Letters
- Vol. 9 (5) , 2257-2264
Conquering Heavy-Loading Decay of High-Temperature Polymer Electrolyte Membrane Fuel Cells with a Conductive Polymer-Based Phosphoric Acid Reservoir
- 3 February 2024
- Published by American Chemical Society (ACS) in ACS Catalysis
- Vol. 14 (4) , 2572-2581
Ultrastable and Phosphoric Acid-Resistant PtRhCu@Pt Oxygen Reduction Electrocatalyst for High-Temperature Polymer Electrolyte Fuel Cells
- 3 February 2024
- Published by American Chemical Society (ACS) in ACS Catalysis
- Vol. 14 (4) , 2572-2581
Ultrastable and Phosphoric Acid-Resistant PtRhCu@Pt Oxygen Reduction Electrocatalyst for High-Temperature Polymer Electrolyte Fuel Cells
- 7 January 2024
- Published by Wiley in Energy Technology
- Vol. 12 (4)
Effect of Operating Conditions on Voltage Transient Response of High‐Temperature Proton Exchange Membrane Fuel Cell Under Load Changing
The transient response of a high‐temperature proton exchange membrane fuel cell (HT‐PEMFC) is critical for control and optimization. The objective of this study is to investigate the effects of operating conditions and control parameters on the transient response of the HT‐PEMFC during load variations to optimize the operating conditions. The main causes of the voltage undershoot are investigated experimentally, and the effects of air stoichiometry, air humidity, operating temperature, and backpressure on the transient response of the HT‐PEMFC are evaluated in terms of internal resistance and voltage response. The results show that during load changes, the local gas starvation of the cell and the change in the hydration state of membrane‐electrode‐assembly may be the main cause of the voltage undershoot. The voltage drop is affected by the combination of ohmic resistance, charge transfer resistance, and mass transfer resistance. In addition, operating temperature and air stoichiometry can affect voltage drop and voltage undershoot during load changes. Proper humidification of the air can alleviate voltage undershoot problems. Increasing the backpressure can improve the transient performance of the cell, but does not alleviate the voltage undershoot problem. The study can provide guidelines for the design and control of HT‐PEMFC operating conditions.
- 7 January 2024
- Published by Wiley in Energy Technology
- Vol. 12 (4)
Effect of Operating Conditions on Voltage Transient Response of High‐Temperature Proton Exchange Membrane Fuel Cell Under Load Changing
The transient response of a high‐temperature proton exchange membrane fuel cell (HT‐PEMFC) is critical for control and optimization. The objective of this study is to investigate the effects of operating conditions and control parameters on the transient response of the HT‐PEMFC during load variations to optimize the operating conditions. The main causes of the voltage undershoot are investigated experimentally, and the effects of air stoichiometry, air humidity, operating temperature, and backpressure on the transient response of the HT‐PEMFC are evaluated in terms of internal resistance and voltage response. The results show that during load changes, the local gas starvation of the cell and the change in the hydration state of membrane‐electrode‐assembly may be the main cause of the voltage undershoot. The voltage drop is affected by the combination of ohmic resistance, charge transfer resistance, and mass transfer resistance. In addition, operating temperature and air stoichiometry can affect voltage drop and voltage undershoot during load changes. Proper humidification of the air can alleviate voltage undershoot problems. Increasing the backpressure can improve the transient performance of the cell, but does not alleviate the voltage undershoot problem. The study can provide guidelines for the design and control of HT‐PEMFC operating conditions.