Chenhao Cong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chenhao Cong has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Xinlin Li
College of Mechanical and Electrical Engineering, Qingdao University, Qingdao 266071, China
8 shared publications - Se Hyun Kim
Department of Materials Science & Engineering, Advanced Materials Program, Konkuk University, Seoul, Republic of Korea
7 shared publications Hongjiang Li
Qingdao University 308 Ningxia Road
5 shared publicationsFuhao Jiang
College of Mechanical and Electrical Engineering
4 shared publicationsHaoran Zhang
College of Mechanical and Electrical Engineering
4 shared publications- Sang Woo Joo
Department of Mechanical and Automotive Engineering, BIC, Tongmyong University
4 shared publications
Latest Publications
Scalable Self‐Powered Sweat Lactate Patches Based on Bulk‐Catalytic MXene/NiO for Wide‐Range Detection
Lactate is a key marker of metabolic load, and sweat‐based wearable sensors offer a non‐invasive platform for assessing exercise intensity and fatigue. However, existing systems often rely on external power and face integration challenges. Here, we present a dispensing‐printed, mass‐producible, flexible, and self‐powered non‐enzymatic lactate sensing platform for real‐time sweat analysis. We employ 2D MXene as a robust conductive scaffold for the in situ growth of NiO nanoparticles. This yields a self‐supporting hybrid material with high electrical conductivity and electrocatalytic activity, making it ideal for both energy storage and enzyme‐free sensing. Additionally, we elucidate the distinct sensing mechanisms of MXene/Ni(OH) 2 and MXene/NiO through spectroscopic and electrochemical analyses. Based on this design, we integrated large‐area asymmetric micro‐supercapacitors (MSCs) and flexible triboelectric nanogenerators (TENGs) with the MXene/NiO sensor to construct a fully self‐powered system. In this architecture, the TENG harvests mechanical energy from body motion, the MSC stores and regulates the electrical energy, and the sensor reliably detects lactate over the physiologically relevant concentration range in human sweat. This integrated energy‐harvesting–storage‐sensing platform provides a general strategy for multifunctional nanomaterial and device design in wearable biosensing.
Scalable Self‐Powered Sweat Lactate Patches Based on Bulk‐Catalytic MXene/NiO for Wide‐Range Detection
Lactate is a key marker of metabolic load, and sweat‐based wearable sensors offer a non‐invasive platform for assessing exercise intensity and fatigue. However, existing systems often rely on external power and face integration challenges. Here, we present a dispensing‐printed, mass‐producible, flexible, and self‐powered non‐enzymatic lactate sensing platform for real‐time sweat analysis. We employ 2D MXene as a robust conductive scaffold for the in situ growth of NiO nanoparticles. This yields a self‐supporting hybrid material with high electrical conductivity and electrocatalytic activity, making it ideal for both energy storage and enzyme‐free sensing. Additionally, we elucidate the distinct sensing mechanisms of MXene/Ni(OH) 2 and MXene/NiO through spectroscopic and electrochemical analyses. Based on this design, we integrated large‐area asymmetric micro‐supercapacitors (MSCs) and flexible triboelectric nanogenerators (TENGs) with the MXene/NiO sensor to construct a fully self‐powered system. In this architecture, the TENG harvests mechanical energy from body motion, the MSC stores and regulates the electrical energy, and the sensor reliably detects lactate over the physiologically relevant concentration range in human sweat. This integrated energy‐harvesting–storage‐sensing platform provides a general strategy for multifunctional nanomaterial and device design in wearable biosensing.
- 9 October 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (41) , 56520-56531
Interface-Programmed Growth of High-Aspect-Ratio 1D Ni–MOF Nanofibers on MXene for Wearable Enzyme-Free Glucose Sensing
Noninvasive wearable glucose sensors capable of real-time sweat analysis offer a less discomforting alternative for long-term monitoring in patients with diabetes. However, practical implementation remains challenging. Major barriers include insufficient catalytic sensitivity to quantify the low glucose levels in sweat, limited compatibility between nanomaterial synthesis and scalable manufacturing processes, and the lack of a biofluid microenvironment suitable for enzyme-free electrochemical sensing. Here, we address these challenges by combining strong interfacial anchoring on a conductive template with surfactant-assisted growth control to engineer high-aspect-ratio (∼100) 1D Ni–TCPP MOF nanofibers as an active shell on MXene–NH2. In contrast to conventional electrospinning-assisted approaches, the resulting 1D MOF shell is polymer-template-free and thus avoids insulating scaffold components. The resulting fluffy, self-supporting Ni-MOF@MXene architecture is inherently compatible with printed electronics, enabling large-area fabrication of wearable enzyme-free glucose-sensing patches. To overcome the constraints of enzyme-free sensing in physiological biofluids, we further develop an integrated system that combines microfluidics with a NaOH/Nafion/PVA alkaline sustained-release membrane, establishing a localized alkaline microenvironment within sweat to enable continuous analysis.
- 9 October 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (41) , 56520-56531
Interface-Programmed Growth of High-Aspect-Ratio 1D Ni–MOF Nanofibers on MXene for Wearable Enzyme-Free Glucose Sensing
Noninvasive wearable glucose sensors capable of real-time sweat analysis offer a less discomforting alternative for long-term monitoring in patients with diabetes. However, practical implementation remains challenging. Major barriers include insufficient catalytic sensitivity to quantify the low glucose levels in sweat, limited compatibility between nanomaterial synthesis and scalable manufacturing processes, and the lack of a biofluid microenvironment suitable for enzyme-free electrochemical sensing. Here, we address these challenges by combining strong interfacial anchoring on a conductive template with surfactant-assisted growth control to engineer high-aspect-ratio (∼100) 1D Ni–TCPP MOF nanofibers as an active shell on MXene–NH2. In contrast to conventional electrospinning-assisted approaches, the resulting 1D MOF shell is polymer-template-free and thus avoids insulating scaffold components. The resulting fluffy, self-supporting Ni-MOF@MXene architecture is inherently compatible with printed electronics, enabling large-area fabrication of wearable enzyme-free glucose-sensing patches. To overcome the constraints of enzyme-free sensing in physiological biofluids, we further develop an integrated system that combines microfluidics with a NaOH/Nafion/PVA alkaline sustained-release membrane, establishing a localized alkaline microenvironment within sweat to enable continuous analysis.
- Open Access
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Bioinspired Ti3C2Tx MXene-based heterojunction for high-performance zearalenone detection in infant food
Portable and easy-to-use sensor platforms are highly sought for the rapid detection of contaminants; however, achieving high sensitivity and stability in complex real sample matrices remains difficult. This study presents a promising Ti3C2Tx MXene-based channel for field-effect transistors, featuring excellent conductivity stabilized by a high-mobility p-type polymer, poly[2,5-(2-octyldodecyl)-3,6-diketopyrrolopyrrole-alt-5,5-(2,5-di(thien-2-yl)thieno [3,2-b]thiophene)] (DPP-DTT), to form a robust and stable conductive composite. Functionalizing the DPP-DTT/MXene composite with zearalenone (ZEN)-selective molecularly imprinted polymers enabled the highly selective and ultrasensitive detection of ZEN mycotoxin in infant food samples without requiring complex sample preparation procedures and extraction protocols. The developed sensor detects ZEN at concentrations of 0.1–400 µg L-1 (r2 = 0.97) with a limit of detection and limit of quantification values of 0.23 and 0.69 µg L-1, respectively. Moreover, the tested commercial infant food matrices exhibited highly predictable responses (ZEN = 0.1–100 µg kg-1) (rice meal, r2 = 0.98; oatmeal cereal, r2 = 0.94; wheat flour, r2 = 0.99). This study demonstrates the feasibility of the developed sensor for ZEN detection in infant foods.
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBioinspired Ti3C2Tx MXene-based heterojunction for high-performance zearalenone detection in infant food
Portable and easy-to-use sensor platforms are highly sought for the rapid detection of contaminants; however, achieving high sensitivity and stability in complex real sample matrices remains difficult. This study presents a promising Ti3C2Tx MXene-based channel for field-effect transistors, featuring excellent conductivity stabilized by a high-mobility p-type polymer, poly[2,5-(2-octyldodecyl)-3,6-diketopyrrolopyrrole-alt-5,5-(2,5-di(thien-2-yl)thieno [3,2-b]thiophene)] (DPP-DTT), to form a robust and stable conductive composite. Functionalizing the DPP-DTT/MXene composite with zearalenone (ZEN)-selective molecularly imprinted polymers enabled the highly selective and ultrasensitive detection of ZEN mycotoxin in infant food samples without requiring complex sample preparation procedures and extraction protocols. The developed sensor detects ZEN at concentrations of 0.1–400 µg L-1 (r2 = 0.97) with a limit of detection and limit of quantification values of 0.23 and 0.69 µg L-1, respectively. Moreover, the tested commercial infant food matrices exhibited highly predictable responses (ZEN = 0.1–100 µg kg-1) (rice meal, r2 = 0.98; oatmeal cereal, r2 = 0.94; wheat flour, r2 = 0.99). This study demonstrates the feasibility of the developed sensor for ZEN detection in infant foods.
- 17 November 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (47) , 64875-64885
Large-Area Fabrication of a Highly Stable Wearable Temperature Sensing System via Dispensing Printing: Carbon-Based Electronic Ink, Self-Charging Sensing, and Remote Human Monitoring
With the rapid advancement of flexible electronics in healthcare diagnostics, real-time body temperature monitoring using electronic skin has become increasingly important for assessing and predicting human health status. Currently, most self-charging temperature sensing systems rely on thermoelectric effects, which are limited to transient detection and lack the resolution necessary to track subtle fluctuations in body temperature (e.g., <0.1 °C), thus constraining their practical use in wearable temperature monitoring. In this study, we developed a high-viscosity carbon-based electronic ink based on the synergistic interaction between 1D and 2D materials. Reduced graphene oxide (rGO) and multiwalled carbon nanotubes (MWCNTs) were used as active materials compatible with high-precision dispensing printing technology to fabricate flexible microtemperature sensors and microsupercapacitors (MSCs). The resulting temperature sensor, with a compact feature size, exhibited a high temperature coefficient of resistance (TCR = -1.08%) and fast response time (1.4 s), comparable to that of commercial rigid platinum-based thermometers. The serpentine electrode design and tightly packed internal structure imparted excellent stability under practical conditions, including encapsulation in insulating oil, mechanical deformation during motion, and repeated cycling. Furthermore, leveraging the versatility of printed electronics, we achieved a self-charging temperature sensing system based on the integrated microsupercapacitor. By incorporating IoT technologies and a bluetooth communication module, we realized real-time remote temperature monitoring, providing a promising platform for next-generation electronic skin in wearable wireless health diagnostics.
- 17 November 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (47) , 64875-64885
Large-Area Fabrication of a Highly Stable Wearable Temperature Sensing System via Dispensing Printing: Carbon-Based Electronic Ink, Self-Charging Sensing, and Remote Human Monitoring
With the rapid advancement of flexible electronics in healthcare diagnostics, real-time body temperature monitoring using electronic skin has become increasingly important for assessing and predicting human health status. Currently, most self-charging temperature sensing systems rely on thermoelectric effects, which are limited to transient detection and lack the resolution necessary to track subtle fluctuations in body temperature (e.g., <0.1 °C), thus constraining their practical use in wearable temperature monitoring. In this study, we developed a high-viscosity carbon-based electronic ink based on the synergistic interaction between 1D and 2D materials. Reduced graphene oxide (rGO) and multiwalled carbon nanotubes (MWCNTs) were used as active materials compatible with high-precision dispensing printing technology to fabricate flexible microtemperature sensors and microsupercapacitors (MSCs). The resulting temperature sensor, with a compact feature size, exhibited a high temperature coefficient of resistance (TCR = -1.08%) and fast response time (1.4 s), comparable to that of commercial rigid platinum-based thermometers. The serpentine electrode design and tightly packed internal structure imparted excellent stability under practical conditions, including encapsulation in insulating oil, mechanical deformation during motion, and repeated cycling. Furthermore, leveraging the versatility of printed electronics, we achieved a self-charging temperature sensing system based on the integrated microsupercapacitor. By incorporating IoT technologies and a bluetooth communication module, we realized real-time remote temperature monitoring, providing a promising platform for next-generation electronic skin in wearable wireless health diagnostics.
- 10 April 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (16) , 24300-24309
Triboelectric Nanogenerators Based on 2D Conductive and High-Dielectric Material Heterostructures for Self-Powered Digital Medicine Applications
With the accelerating advancement of health monitoring and intelligent motion detection technologies, wearable flexible sensors have emerged as indispensable tools for real-time human activity monitoring. Self-powered systems centered on triboelectric nanogenerators (TENGs), which obviate the requirement for external power sources, have garnered substantial attention. However, attaining both high electrical performance and mechanical flexibility persists as a pivotal challenge. To tackle this, we propose a groundbreaking strategy that incorporates two-dimensional (2D) graphene as a conductive template with amino-modified BaTiO3 nanoparticles (BaTiO3-NH2), a high-dielectric-constant material, to develop a high-performance flexible TENG for human motion detection. The dual role of graphene is maximized: its superior electrical conductivity facilitates the formation of microcapacitive structures, while its 2D sheet structure promotes the uniform dispersion of BaTiO3-NH2, mitigating agglomeration issues and maintaining mechanical integrity. The fabricated TENG exhibited remarkable performance, attaining a high power output of 0.48 W/m2 in single-electrode mode for energy harvesting and a peak open-circuit voltage of 380 V for wearable sensing. These augmented properties permitted precise detection of diverse human motion patterns in real-world wearable scenarios and broadened its application to precise sensing in ball sports. This study illustrates the synergistic advantages of integrating 2D conductive materials with high-dielectric nanoparticles, offering a promising strategy for developing next-generation self-powered sensors. The designed TENG possesses significant potential for energy harvesting, wearable sensing, and advanced electronic skin applications in human-machine interfaces.
- 10 April 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (16) , 24300-24309
Triboelectric Nanogenerators Based on 2D Conductive and High-Dielectric Material Heterostructures for Self-Powered Digital Medicine Applications
With the accelerating advancement of health monitoring and intelligent motion detection technologies, wearable flexible sensors have emerged as indispensable tools for real-time human activity monitoring. Self-powered systems centered on triboelectric nanogenerators (TENGs), which obviate the requirement for external power sources, have garnered substantial attention. However, attaining both high electrical performance and mechanical flexibility persists as a pivotal challenge. To tackle this, we propose a groundbreaking strategy that incorporates two-dimensional (2D) graphene as a conductive template with amino-modified BaTiO3 nanoparticles (BaTiO3-NH2), a high-dielectric-constant material, to develop a high-performance flexible TENG for human motion detection. The dual role of graphene is maximized: its superior electrical conductivity facilitates the formation of microcapacitive structures, while its 2D sheet structure promotes the uniform dispersion of BaTiO3-NH2, mitigating agglomeration issues and maintaining mechanical integrity. The fabricated TENG exhibited remarkable performance, attaining a high power output of 0.48 W/m2 in single-electrode mode for energy harvesting and a peak open-circuit voltage of 380 V for wearable sensing. These augmented properties permitted precise detection of diverse human motion patterns in real-world wearable scenarios and broadened its application to precise sensing in ball sports. This study illustrates the synergistic advantages of integrating 2D conductive materials with high-dielectric nanoparticles, offering a promising strategy for developing next-generation self-powered sensors. The designed TENG possesses significant potential for energy harvesting, wearable sensing, and advanced electronic skin applications in human-machine interfaces.
- 3 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 7 (3) , 1217-1229
Bio-Inspired Hydrogen Bonding Cross-Linking Strategy for DIW-Printed Carbon-Based Conductive Hydrogels in Wearable Self-Powered Sensing Systems
- 3 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 7 (3) , 1217-1229
Bio-Inspired Hydrogen Bonding Cross-Linking Strategy for DIW-Printed Carbon-Based Conductive Hydrogels in Wearable Self-Powered Sensing Systems
- 16 August 2024
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 677 (Pt B) , 862-871
Interfacial modulation strategy using poly(3,4-ethylenedioxythiophene)–poly(4-styrenesulfonate) (PEDOT:PSS) and ultrathin two-dimensional metal–organic framework nanosheets for wearable supercapacitors: Solution engineering
- 16 August 2024
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 677 (Pt B) , 862-871
Interfacial modulation strategy using poly(3,4-ethylenedioxythiophene)–poly(4-styrenesulfonate) (PEDOT:PSS) and ultrathin two-dimensional metal–organic framework nanosheets for wearable supercapacitors: Solution engineering
- Open Access
- 14 February 2024
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 25 (1) , 2311635
Fully printed non-contact touch sensors based on GCN/PDMS composites: enabling over-the-bottom detection, 3D recognition, and wireless transmission
The rapid advancement in intelligent bionics has elevated electronic skin to a pivotal component in bionic robots, enabling swift responses to diverse external stimuli. Combining wearable touch sensors with IoT technology lays the groundwork for achieving the versatile functionality of electronic skin. However, most current touch sensors rely on capacitive layer deformations induced by pressure, leading to changes in capacitance values. Unfortunately, sensors of this kind often face limitations in practical applications due to their uniform sensing capabilities. This study presents a novel approach by incorporating graphitic carbon nitride (GCN) into polydimethylsiloxane (PDMS) at a low concentration. Surprisingly, this blend of materials with higher dielectric constants yields composite films with lower dielectric constants, contrary to expectations. Unlike traditional capacitive sensors, our non-contact touch sensors exploit electric field interference between the object and the sensor’s edge, with enhanced effects from the low dielectric constant GCN/PDMS film. Consequently, we have fabricated touch sensor grids using an array configuration of dispensing printing techniques, facilitating fast response and ultra-low-limit contact detection with finger-to-device distances ranging from 5 to 100 mm. These sensors exhibit excellent resolution in recognizing 3D object shapes and accurately detecting positional motion. Moreover, they enable real-time monitoring of array data with signal transmission over a 4G network. In summary, our proposed approach for fabricating low dielectric constant thin films, as employed in non-contact touch sensors, opens new avenues for advancing electronic skin technology.
- 14 February 2024
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 25 (1) , 2311635
Open AccessFully printed non-contact touch sensors based on GCN/PDMS composites: enabling over-the-bottom detection, 3D recognition, and wireless transmission
The rapid advancement in intelligent bionics has elevated electronic skin to a pivotal component in bionic robots, enabling swift responses to diverse external stimuli. Combining wearable touch sensors with IoT technology lays the groundwork for achieving the versatile functionality of electronic skin. However, most current touch sensors rely on capacitive layer deformations induced by pressure, leading to changes in capacitance values. Unfortunately, sensors of this kind often face limitations in practical applications due to their uniform sensing capabilities. This study presents a novel approach by incorporating graphitic carbon nitride (GCN) into polydimethylsiloxane (PDMS) at a low concentration. Surprisingly, this blend of materials with higher dielectric constants yields composite films with lower dielectric constants, contrary to expectations. Unlike traditional capacitive sensors, our non-contact touch sensors exploit electric field interference between the object and the sensor’s edge, with enhanced effects from the low dielectric constant GCN/PDMS film. Consequently, we have fabricated touch sensor grids using an array configuration of dispensing printing techniques, facilitating fast response and ultra-low-limit contact detection with finger-to-device distances ranging from 5 to 100 mm. These sensors exhibit excellent resolution in recognizing 3D object shapes and accurately detecting positional motion. Moreover, they enable real-time monitoring of array data with signal transmission over a 4G network. In summary, our proposed approach for fabricating low dielectric constant thin films, as employed in non-contact touch sensors, opens new avenues for advancing electronic skin technology.
- 19 November 2023
- Published by Elsevier in Chemical Engineering Journal
- Vol. 479
Electrohydrodynamic-printed ultrathin Ti3C2Tx-MXene field-effect transistor for probing aflatoxin B1
- 19 November 2023
- Published by Elsevier in Chemical Engineering Journal
- Vol. 479
Electrohydrodynamic-printed ultrathin Ti3C2Tx-MXene field-effect transistor for probing aflatoxin B1
- 15 September 2023
- Published by Elsevier in Chemical Engineering Journal
- Vol. 474
Alignment of Fe3O4/CNT electrodes via magnetic blade printing for wireless stress-direction-recognizing strain sensor
- 15 September 2023
- Published by Elsevier in Chemical Engineering Journal
- Vol. 474
Alignment of Fe3O4/CNT electrodes via magnetic blade printing for wireless stress-direction-recognizing strain sensor