Wule Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wule Zhu has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Bingfeng Ju
Zhejiang University
3 shared publications Anyu Sun
Zhejiang University, School of Mechanical Engineering, The State Key Lab of Fluid Power Transmission and Control, Hangzhou, China
2 shared publicationsBing-Feng Ju
The State Key Laboratory of Fluid Power & Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Xihu District, Hangzhou 310058, Zhejiang, People’s Republic of China
2 shared publicationsBingfeng Ju
Department of Mechanical Engineering, Zhejiang University, Hangzhou, China
2 shared publications- Wen-Hao Zhang
The State Key Laboratory of Fluid Power & Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Xihu District, Hangzhou 310058, Zhejiang, People’s Republic of China
2 shared publications - Anyu Sun
School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
1 shared publication
Latest Publications
- Open Access
Influence of Modifying Additives on Resin-Bonded Diamond Tool and Single-Crystal Silicon Lapping Performance
To improve the interfacial tribological conditions, debris evacuation, and surface integrity in single-crystal silicon lapping using resin-bonded diamond tools, a multifunctional resin-bonded diamond tool incorporating lubricating, surface-quality-regulating, and pore-forming additives was developed. Single-factor experiments were conducted to evaluate the effects of graphite, MoS2, and Polytetrafluoroethylene (PTFE); CeO2, SiO2, and ZrO2; and NH4HCO3, NaHCO3, and NaCl on tool performance and silicon-surface quality. PTFE exhibited the best overall lubrication performance, reducing the temperature rise by 18.0% compared with the control. The addition of 1 wt.% CeO2 reduced the surface roughness Sa from 11.72 to 9.47 nm and decreased the residual compressive stress by approximately 86.5%. Moreover, 10 wt.% NH4HCO3 increased the apparent porosity from 6.76% to 32.42% and improved the sustainability of material removal. Based on the single-factor results, an L9 orthogonal experiment was performed using PTFE, CeO2, and NH4HCO3 as the control factors. Multi-response optimization identified a balanced formulation containing 1.5 wt.% PTFE, 1.0 wt.% CeO2, and 10 wt.% NH4HCO3. Validation experiments yielded a Sa of 8.46 nm, MRR = 58.85 nm/min, a material removal-to-tool wear ratio (W-ratio) of 7.67, and a residual stress of −55.20 MPa, demonstrating a favorable balance among surface quality, material-removal efficiency, and tool durability.
Open AccessInfluence of Modifying Additives on Resin-Bonded Diamond Tool and Single-Crystal Silicon Lapping Performance
To improve the interfacial tribological conditions, debris evacuation, and surface integrity in single-crystal silicon lapping using resin-bonded diamond tools, a multifunctional resin-bonded diamond tool incorporating lubricating, surface-quality-regulating, and pore-forming additives was developed. Single-factor experiments were conducted to evaluate the effects of graphite, MoS2, and Polytetrafluoroethylene (PTFE); CeO2, SiO2, and ZrO2; and NH4HCO3, NaHCO3, and NaCl on tool performance and silicon-surface quality. PTFE exhibited the best overall lubrication performance, reducing the temperature rise by 18.0% compared with the control. The addition of 1 wt.% CeO2 reduced the surface roughness Sa from 11.72 to 9.47 nm and decreased the residual compressive stress by approximately 86.5%. Moreover, 10 wt.% NH4HCO3 increased the apparent porosity from 6.76% to 32.42% and improved the sustainability of material removal. Based on the single-factor results, an L9 orthogonal experiment was performed using PTFE, CeO2, and NH4HCO3 as the control factors. Multi-response optimization identified a balanced formulation containing 1.5 wt.% PTFE, 1.0 wt.% CeO2, and 10 wt.% NH4HCO3. Validation experiments yielded a Sa of 8.46 nm, MRR = 58.85 nm/min, a material removal-to-tool wear ratio (W-ratio) of 7.67, and a residual stress of −55.20 MPa, demonstrating a favorable balance among surface quality, material-removal efficiency, and tool durability.
- Open Access
Development of the Stitching—Oblique Incidence Interferometry Measurement Method for the Surface Flatness of Large-Scale and Elongated Ceramic Parts
With the increasing demand for high-performance ceramic guideways in precision industries, accurate flatness measurement of large-scale, rough ceramic surfaces remains challenging. This paper proposes a novel method combining oblique-incidence laser interferometry and sub-aperture stitching to overcome limitations of conventional techniques. The oblique-incidence approach enhances interference signal strength on low-reflectivity surfaces, while stitching integrates high-resolution sub-aperture measurements for full-surface characterization. Numerical simulations validated the method’s feasibility, showing consistent reconstruction of surfaces with flatness values of 1–20 μm. Experimental validation on a 1050 mm × 130 mm SiC guideway achieved a full-surface measurement with PV 2.76 μm and RMS 0.59 μm, demonstrating high agreement with traditional methods in polished regions. The technique enabled quick monitoring of a 39-h lapping process, converging flatness from 13.97 μm to 2.76 μm, proving its efficacy for in-process feedback in ultra-precision manufacturing.
Open AccessDevelopment of the Stitching—Oblique Incidence Interferometry Measurement Method for the Surface Flatness of Large-Scale and Elongated Ceramic Parts
With the increasing demand for high-performance ceramic guideways in precision industries, accurate flatness measurement of large-scale, rough ceramic surfaces remains challenging. This paper proposes a novel method combining oblique-incidence laser interferometry and sub-aperture stitching to overcome limitations of conventional techniques. The oblique-incidence approach enhances interference signal strength on low-reflectivity surfaces, while stitching integrates high-resolution sub-aperture measurements for full-surface characterization. Numerical simulations validated the method’s feasibility, showing consistent reconstruction of surfaces with flatness values of 1–20 μm. Experimental validation on a 1050 mm × 130 mm SiC guideway achieved a full-surface measurement with PV 2.76 μm and RMS 0.59 μm, demonstrating high agreement with traditional methods in polished regions. The technique enabled quick monitoring of a 39-h lapping process, converging flatness from 13.97 μm to 2.76 μm, proving its efficacy for in-process feedback in ultra-precision manufacturing.
- Open Access
- 4 November 2024
- Published by Springer Nature in Nanomanufacturing and Metrology
- Vol. 7 (1) , 1-11
A New Method for Measuring Multilayer Thickness Using a Chromatic Confocal Sensor
Multilayer transparent plates play a crucial role in industrial fields, such as optical lenses, electrodes, and solar panels, because of their superior optical and electrical properties. The thickness and uniformity of such plates are decisive for the quality of the final product. However, traditional contact measurement methods are inadequate in accuracy and pose the risk of damaging the plates, making nondestructive measurement of multilayer transparent plate thickness rather challenging. A new measurement technology is urgently needed. This study proposes a new method for the thickness measurement of multilayer transparent plates based on chromatic confocal sensor technology. First, we investigated the dispersive behavior of light in various media layers and derived theoretical measurement models for single-layer and multilayer transparent plate thicknesses. Subsequently, we designed and constructed a measurement system using a C-series chromatic confocal sensor and optical instruments and prepared a five-layer transparent sample consisting of quartz and air layers to confirm the feasibility of the method. The results of the experiment show that the proposed method can accurately measure the thickness of the five-layer sample with a maximum absolute error within 13 µm and a maximum relative error of 4.27%, thus proving its validity, precision, and stability. The results further indicate the high practicality and reliability of this technology in production environments, theoretically enabling the simultaneous measurement of up to 18 layers of the plate and offering broad application prospects in the industry.
- 4 November 2024
- Published by Springer Nature in Nanomanufacturing and Metrology
- Vol. 7 (1) , 1-11
Open AccessA New Method for Measuring Multilayer Thickness Using a Chromatic Confocal Sensor
Multilayer transparent plates play a crucial role in industrial fields, such as optical lenses, electrodes, and solar panels, because of their superior optical and electrical properties. The thickness and uniformity of such plates are decisive for the quality of the final product. However, traditional contact measurement methods are inadequate in accuracy and pose the risk of damaging the plates, making nondestructive measurement of multilayer transparent plate thickness rather challenging. A new measurement technology is urgently needed. This study proposes a new method for the thickness measurement of multilayer transparent plates based on chromatic confocal sensor technology. First, we investigated the dispersive behavior of light in various media layers and derived theoretical measurement models for single-layer and multilayer transparent plate thicknesses. Subsequently, we designed and constructed a measurement system using a C-series chromatic confocal sensor and optical instruments and prepared a five-layer transparent sample consisting of quartz and air layers to confirm the feasibility of the method. The results of the experiment show that the proposed method can accurately measure the thickness of the five-layer sample with a maximum absolute error within 13 µm and a maximum relative error of 4.27%, thus proving its validity, precision, and stability. The results further indicate the high practicality and reliability of this technology in production environments, theoretically enabling the simultaneous measurement of up to 18 layers of the plate and offering broad application prospects in the industry.
- 28 May 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (8) , 085023
Unified framework for geometric error compensation and shape-adaptive scanning in five-axis metrology systems
In response to the escalating demand for precise shape metrology of complex optical surfaces, this study unveils a unified geometric error compensation and trajectory planning framework tailored for high-accuracy five-axis scanning metrology systems, which remains a notably underexplored field compared to error compensation in machine tools. Founded on a unified geometric model, the proposed framework seamlessly integrates a versatile shape-adaptive trajectory planning strategy, a thorough global error sensitivity analysis approach, and an exhaustive geometric error compensation scheme. Leveraging inverse kinematics, an innovative shape-adaptive scanning trajectory generation strategy is mathematically formulated, thereby facilitating adaptable measurement trajectory generation for diverse surface geometries. Employing forward kinematics, an exhaustive geometric error model is established to extensively address the 53 distinct geometric errors in the metrology system. This proposed error model fundamentally augments conventional geometric error models in machine tool by managing not only the geometric errors from the motion system, but also those from the probe and workpiece. To streamline the error compensation procedure, a novel global error sensitivity analysis approach is introduced, identifying both system-oriented and process-oriented sensitive geometric errors for targeted compensation. Experimental validation using a standard ball, which achieved an exceptional 89.35% reduction in the root mean square of the measurement errors, further confirms the feasibility and effectiveness of the proposed framework. By offering an universal trajectory planning, sensitivity analysis and error compensation trinity for five-axis scanning metrology systems, this study sets the stage for precision advancements and design optimization across diverse configurations of metrology systems.
- 28 May 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (8) , 085023
Unified framework for geometric error compensation and shape-adaptive scanning in five-axis metrology systems
In response to the escalating demand for precise shape metrology of complex optical surfaces, this study unveils a unified geometric error compensation and trajectory planning framework tailored for high-accuracy five-axis scanning metrology systems, which remains a notably underexplored field compared to error compensation in machine tools. Founded on a unified geometric model, the proposed framework seamlessly integrates a versatile shape-adaptive trajectory planning strategy, a thorough global error sensitivity analysis approach, and an exhaustive geometric error compensation scheme. Leveraging inverse kinematics, an innovative shape-adaptive scanning trajectory generation strategy is mathematically formulated, thereby facilitating adaptable measurement trajectory generation for diverse surface geometries. Employing forward kinematics, an exhaustive geometric error model is established to extensively address the 53 distinct geometric errors in the metrology system. This proposed error model fundamentally augments conventional geometric error models in machine tool by managing not only the geometric errors from the motion system, but also those from the probe and workpiece. To streamline the error compensation procedure, a novel global error sensitivity analysis approach is introduced, identifying both system-oriented and process-oriented sensitive geometric errors for targeted compensation. Experimental validation using a standard ball, which achieved an exceptional 89.35% reduction in the root mean square of the measurement errors, further confirms the feasibility and effectiveness of the proposed framework. By offering an universal trajectory planning, sensitivity analysis and error compensation trinity for five-axis scanning metrology systems, this study sets the stage for precision advancements and design optimization across diverse configurations of metrology systems.
- Open Access
Novel Information-Driven Smoothing Spline Linearization Method for High-Precision Displacement Sensors Based on Information Criterions
A noise-resistant linearization model that reveals the true nonlinearity of the sensor is essential for retrieving accurate physical displacement from the signals captured by sensing electronics. In this paper, we propose a novel information-driven smoothing spline linearization method, which innovatively integrates one new and three standard information criterions into a smoothing spline for the high-precision displacement sensors’ linearization. Using theoretical analysis and Monte Carlo simulation, the proposed linearization method is demonstrated to outperform traditional polynomial and spline linearization methods for high-precision displacement sensors with a low noise to range ratio in the 10−5 level. Validation experiments were carried out on two different types of displacement sensors to benchmark the performance of the proposed method compared to the polynomial models and the the non-smoothing cubic spline. The results show that the proposed method with the new modified Akaike Information Criterion stands out compared to the other linearization methods and can improve the residual nonlinearity by over 50% compared to the standard polynomial model. After being linearized via the proposed method, the residual nonlinearities reach as low as ±0.0311% F.S. (Full Scale of Range), for the 1.5 mm range chromatic confocal displacement sensor, and ±0.0047% F.S., for the 100 mm range laser triangulation displacement sensor.
Open AccessNovel Information-Driven Smoothing Spline Linearization Method for High-Precision Displacement Sensors Based on Information Criterions
A noise-resistant linearization model that reveals the true nonlinearity of the sensor is essential for retrieving accurate physical displacement from the signals captured by sensing electronics. In this paper, we propose a novel information-driven smoothing spline linearization method, which innovatively integrates one new and three standard information criterions into a smoothing spline for the high-precision displacement sensors’ linearization. Using theoretical analysis and Monte Carlo simulation, the proposed linearization method is demonstrated to outperform traditional polynomial and spline linearization methods for high-precision displacement sensors with a low noise to range ratio in the 10−5 level. Validation experiments were carried out on two different types of displacement sensors to benchmark the performance of the proposed method compared to the polynomial models and the the non-smoothing cubic spline. The results show that the proposed method with the new modified Akaike Information Criterion stands out compared to the other linearization methods and can improve the residual nonlinearity by over 50% compared to the standard polynomial model. After being linearized via the proposed method, the residual nonlinearities reach as low as ±0.0311% F.S. (Full Scale of Range), for the 1.5 mm range chromatic confocal displacement sensor, and ±0.0047% F.S., for the 100 mm range laser triangulation displacement sensor.
- 1 August 2023
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 62 (08) , 084103-13
Bilateral form characterization of curved transparent components using chromatic confocal sensor
To accurately characterize the geometric form of key components in industrial products, many profile measuring instruments have been developed to date. However, there are some special components, such as the hemispherical resonators featuring thin curved transparent surfaces, which are difficult to be measured using general instruments. The chromatic confocal technology was introduced in this paper to conduct the bilateral form characterization of this type of surfaces. Based on the assumption of tilted plate approximation, a modified ray tracing model was presented to correct the errors produced by the curved surfaces. The experiment of measurement on tilted, fused silica plates was conducted to demonstrate the effectiveness of the proposed model. Results show that the developed model improves the measurement accuracy of plates with large tilt angle. A three-axis motion stage was built with self-developed chromatic confocal sensor to obtain the bilateral profiles of the resonator. By fitting the spheres with the scanning profiles, the form error between the measurement points and the fitted spheres can be calculated. Partial form errors along the circumferential and axial directions of the resonator are evaluated, and an intuitive assessment of its thickness variation along the circumferential direction was made.
- 1 August 2023
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 62 (08) , 084103-13
Bilateral form characterization of curved transparent components using chromatic confocal sensor
To accurately characterize the geometric form of key components in industrial products, many profile measuring instruments have been developed to date. However, there are some special components, such as the hemispherical resonators featuring thin curved transparent surfaces, which are difficult to be measured using general instruments. The chromatic confocal technology was introduced in this paper to conduct the bilateral form characterization of this type of surfaces. Based on the assumption of tilted plate approximation, a modified ray tracing model was presented to correct the errors produced by the curved surfaces. The experiment of measurement on tilted, fused silica plates was conducted to demonstrate the effectiveness of the proposed model. Results show that the developed model improves the measurement accuracy of plates with large tilt angle. A three-axis motion stage was built with self-developed chromatic confocal sensor to obtain the bilateral profiles of the resonator. By fitting the spheres with the scanning profiles, the form error between the measurement points and the fitted spheres can be calculated. Partial form errors along the circumferential and axial directions of the resonator are evaluated, and an intuitive assessment of its thickness variation along the circumferential direction was made.
- Open Access
Integrated Development of a Topology-Optimized Compliant Mechanism for Precise Positioning
A scheme for modelling and controlling a two-dimensional positioning system with a topology-optimized compliant mechanism is presented. The system is designed to ensure a relatively large workspace and exhibit robustness against system nonlinearities. A detailed design procedure based on topology optimization is presented, and a nonlinear description of the designed mechanism is developed as a starting point for further precise position control. The theoretical model is shown to be suitable for a considerably larger working range without losing consistency. A backstepping controller is employed to manipulate the nonlinearities in the model resulting from the geometrical and material nonlinearity of the mechanical structure. The hysteresis of the piezoelectric actuator is also taken into consideration. An experimental verification of the controller demonstrates that the proposed design approach improves the performance of compliant mechanism and satisfies the needs for precision positioning.
Open AccessIntegrated Development of a Topology-Optimized Compliant Mechanism for Precise Positioning
A scheme for modelling and controlling a two-dimensional positioning system with a topology-optimized compliant mechanism is presented. The system is designed to ensure a relatively large workspace and exhibit robustness against system nonlinearities. A detailed design procedure based on topology optimization is presented, and a nonlinear description of the designed mechanism is developed as a starting point for further precise position control. The theoretical model is shown to be suitable for a considerably larger working range without losing consistency. A backstepping controller is employed to manipulate the nonlinearities in the model resulting from the geometrical and material nonlinearity of the mechanical structure. The hysteresis of the piezoelectric actuator is also taken into consideration. An experimental verification of the controller demonstrates that the proposed design approach improves the performance of compliant mechanism and satisfies the needs for precision positioning.
- Open Access
Development of a Parallel Dual-Stage Compliant Nanopositioning System
This paper presents a novel parallel dual-stage compliant nanopositioning system (PDCNS), aimed at nanoscale positioning for microscale manipulation. In the developed PDCNS, the coarse stage actuated by the voice coil motor and the fine stage driven by the piezoelectric actuator are integrated in a parallel manner by a specially devised A-shaped compliant mechanism, which leads to many excellent performances, such as good resolution and large stroke and broadband. To enhance the closed-loop-positioning capability of the proposed PDCNS, a double-servo cooperative control (DSCC) strategy is specially constructed. The performance of the proposed PDCNS is evaluated by analytical model, finite element analysis, and experimental research. Results show that the first-order resonance frequency of the designed A-shaped compliant mechanism can reach 99.7 Hz. Combined with the designed DSCC, the developed PDCNS prototype is demonstrated to provide a stroke of 1.49 mm and a positioning resolution of ≤50 nm.
Open AccessDevelopment of a Parallel Dual-Stage Compliant Nanopositioning System
This paper presents a novel parallel dual-stage compliant nanopositioning system (PDCNS), aimed at nanoscale positioning for microscale manipulation. In the developed PDCNS, the coarse stage actuated by the voice coil motor and the fine stage driven by the piezoelectric actuator are integrated in a parallel manner by a specially devised A-shaped compliant mechanism, which leads to many excellent performances, such as good resolution and large stroke and broadband. To enhance the closed-loop-positioning capability of the proposed PDCNS, a double-servo cooperative control (DSCC) strategy is specially constructed. The performance of the proposed PDCNS is evaluated by analytical model, finite element analysis, and experimental research. Results show that the first-order resonance frequency of the designed A-shaped compliant mechanism can reach 99.7 Hz. Combined with the designed DSCC, the developed PDCNS prototype is demonstrated to provide a stroke of 1.49 mm and a positioning resolution of ≤50 nm.
- 16 April 2022
- Published by Springer Nature
- p. 78-84
Spindle-Less Vibration-Servo Grinding of Brittle Materials
- 16 April 2022
- Published by Springer Nature
- p. 78-84
Spindle-Less Vibration-Servo Grinding of Brittle Materials