Bo Hao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bo Hao has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Li Zhang
Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
7 shared publications - Haojin Yang
Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
3 shared publications - Joseph Jao Yiu Sung
Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore 308232, Singapore
3 shared publications - Junnan Xue
Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong SAR 999077, P. R. China
3 shared publications - Kai Fung Chan
Chow Yuk Ho Technology Centre for Innovative Medicine, The Chinese University of Hong Kong, Hong Kong SAR, China
3 shared publications - Lin Su
Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
3 shared publications
Latest Publications
- Open Access
- 15 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (20) , eaeb9792
Microswarm bridging effect for dual-surface biofilm eradication in submillimeter infection pockets
Biofilm infections in submillimeter interstices at soft tissue-implant/hard tissue interfaces (infection pockets) pose substantial health risks. Traditional surgical and microrobotic strategies struggle to address biofilms in these multicurvature spaces. Here, we report the bridging effect of microswarm self-assembled from magnetic hydrogel particles to eradicate biofilms in infection pockets. The microswarm dynamically bridges dual surfaces within infection pockets, enabling continuous, stable contact and force delivery across concave, plane, and convex surfaces through optimized thickness and shear force. The synergy of enzymatic degradation and mechanical disruption enhances biofilm eradication efficiency by eightfold compared to mechanical disruption alone. A multifunctional hydrogel filler is further used to remove biofilm debris and inhibit microbial recolonization, eventually achieving >99% biofilm elimination in ex vivo and in vivo models. This strategy uses the bridging effect, shape reconfigurability, and enzymatic-mechanical synergy of microswarm, offering a minimally invasive, site-specific solution for deep-tissue infections and persistent biofilms, with reduced reliance on antibiotics.
- 15 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (20) , eaeb9792
Open AccessMicroswarm bridging effect for dual-surface biofilm eradication in submillimeter infection pockets
Biofilm infections in submillimeter interstices at soft tissue-implant/hard tissue interfaces (infection pockets) pose substantial health risks. Traditional surgical and microrobotic strategies struggle to address biofilms in these multicurvature spaces. Here, we report the bridging effect of microswarm self-assembled from magnetic hydrogel particles to eradicate biofilms in infection pockets. The microswarm dynamically bridges dual surfaces within infection pockets, enabling continuous, stable contact and force delivery across concave, plane, and convex surfaces through optimized thickness and shear force. The synergy of enzymatic degradation and mechanical disruption enhances biofilm eradication efficiency by eightfold compared to mechanical disruption alone. A multifunctional hydrogel filler is further used to remove biofilm debris and inhibit microbial recolonization, eventually achieving >99% biofilm elimination in ex vivo and in vivo models. This strategy uses the bridging effect, shape reconfigurability, and enzymatic-mechanical synergy of microswarm, offering a minimally invasive, site-specific solution for deep-tissue infections and persistent biofilms, with reduced reliance on antibiotics.
- Top Cited PapersOpen Access
- 24 October 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (43) , eady4339
Modular magnetic microrobot system for robust endoluminal navigation and high–radial force stent delivery in complex ductal anatomy
Endoluminal stent implantation is a common intervention strategy for treating obstructive lesions, but conventional delivery systems struggle to reach deep, tortuous ducts. To overcome this limitation, we present a magnetically controlled microrobot that integrates two functional modules: a magnetic actuation (MA) module for agile navigation and an ultrasound-responsive self-expanding stent module (ST module) for lesion-specific dilation. The system uses a dynamically tunable assembly mechanism governed by rotational direction enabling integrated locomotion (clockwise) and on-demand module separation (counterclockwise) at stenotic sites. The platform is compatible with intraoperative ultrasound, allowing real-time navigation and thermally triggered expansion in physiological environments. By synergizing programmable magnetic actuation, ultrasound-mediated expansion, and clinical workflow compatibility, the robot can navigate tortuous phantom ducts, achieving controlled stent deployment within 3 seconds and complete expansion within 30 seconds, permitting minimally invasive treatment of biliary strictures. This work advances microrobotic stent delivery by overcoming key barriers to clinical translation in endoluminal interventions.
- 24 October 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (43) , eady4339
Top Cited PapersOpen AccessModular magnetic microrobot system for robust endoluminal navigation and high–radial force stent delivery in complex ductal anatomy
Endoluminal stent implantation is a common intervention strategy for treating obstructive lesions, but conventional delivery systems struggle to reach deep, tortuous ducts. To overcome this limitation, we present a magnetically controlled microrobot that integrates two functional modules: a magnetic actuation (MA) module for agile navigation and an ultrasound-responsive self-expanding stent module (ST module) for lesion-specific dilation. The system uses a dynamically tunable assembly mechanism governed by rotational direction enabling integrated locomotion (clockwise) and on-demand module separation (counterclockwise) at stenotic sites. The platform is compatible with intraoperative ultrasound, allowing real-time navigation and thermally triggered expansion in physiological environments. By synergizing programmable magnetic actuation, ultrasound-mediated expansion, and clinical workflow compatibility, the robot can navigate tortuous phantom ducts, achieving controlled stent deployment within 3 seconds and complete expansion within 30 seconds, permitting minimally invasive treatment of biliary strictures. This work advances microrobotic stent delivery by overcoming key barriers to clinical translation in endoluminal interventions.
- 17 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (106) , eadu4851
Miniature magneto-ultrasonic machines for wireless robotic sensing and manipulation
Intelligent miniature systems capable of wireless sensing and manipulation hold considerable promise for advancing biomedical applications. However, the development of these systems has been substantially hindered by sensing-actuation incompatibility at small scales. To overcome this challenge, we propose a robotic sensing approach that integrates embedded ultrasonic soft sensors (EUSSs) with magnetic actuators, resulting in a wireless sensor-integrated miniature machine with seamless integration and minimal interference between fields. The EUSS, with its compact dimensions (1.3 millimeters by 1.3 millimeters by 1.6 millimeters), softness (98 kilopascals), and lightweight design (4.6 milligrams), is compatible with both soft and rigid components in terms of deformability and size. By engineering onboard transducers and using passive ultrasound communication along with external magnetic fields, we could wirelessly detect and regulate environmental parameters such as force, vibration, viscosity, and temperature. Demonstrations in rabbit and porcine models show the potential for robotic feedback control, accurate drug dosing, and in situ physiological monitoring, paving the way for real-world applications of intelligent miniature machines.
- 17 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (106) , eadu4851
Miniature magneto-ultrasonic machines for wireless robotic sensing and manipulation
Intelligent miniature systems capable of wireless sensing and manipulation hold considerable promise for advancing biomedical applications. However, the development of these systems has been substantially hindered by sensing-actuation incompatibility at small scales. To overcome this challenge, we propose a robotic sensing approach that integrates embedded ultrasonic soft sensors (EUSSs) with magnetic actuators, resulting in a wireless sensor-integrated miniature machine with seamless integration and minimal interference between fields. The EUSS, with its compact dimensions (1.3 millimeters by 1.3 millimeters by 1.6 millimeters), softness (98 kilopascals), and lightweight design (4.6 milligrams), is compatible with both soft and rigid components in terms of deformability and size. By engineering onboard transducers and using passive ultrasound communication along with external magnetic fields, we could wirelessly detect and regulate environmental parameters such as force, vibration, viscosity, and temperature. Demonstrations in rabbit and porcine models show the potential for robotic feedback control, accurate drug dosing, and in situ physiological monitoring, paving the way for real-world applications of intelligent miniature machines.
- Top Cited PapersOpen Access
- 20 June 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (25) , eadv1682
A magnetically actuated microcatheter with soft rotatable tip for enhanced endovascular access and treatment efficiency
Endovascular interventions require fast access to affected regions, followed by effective treatment. Catheterizations are effective approaches for treating vascular diseases; however, they face challenges in accessibility, efficiency, and invasiveness in narrow, tortuous vascular systems. This study presents a submillimeter magnetically actuated soft rotatable-tipped microcatheter (MSRM) designed to access small blood vessels and provide efficient, minimally invasive therapeutic interventions for blood clot treatment. The MSRM’s rotatable tip design enhances accessibility and navigation speed through a rotation-assisted active steering strategy. Improved blood clot treatment efficiency is achieved through the MSRM’s multifunctionality: It can accelerate drug-blood clot interactions, mechanically break down blood clots, and retrieve clot debris. The low invasiveness is attributed to the soft material design and conservative actuation strategy. The performance of the MSRM is validated in both in vitro phantom studies and in vivo rabbit models, and the invasiveness is evaluated using a human placenta model.
- 20 June 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (25) , eadv1682
Top Cited PapersOpen AccessA magnetically actuated microcatheter with soft rotatable tip for enhanced endovascular access and treatment efficiency
Endovascular interventions require fast access to affected regions, followed by effective treatment. Catheterizations are effective approaches for treating vascular diseases; however, they face challenges in accessibility, efficiency, and invasiveness in narrow, tortuous vascular systems. This study presents a submillimeter magnetically actuated soft rotatable-tipped microcatheter (MSRM) designed to access small blood vessels and provide efficient, minimally invasive therapeutic interventions for blood clot treatment. The MSRM’s rotatable tip design enhances accessibility and navigation speed through a rotation-assisted active steering strategy. Improved blood clot treatment efficiency is achieved through the MSRM’s multifunctionality: It can accelerate drug-blood clot interactions, mechanically break down blood clots, and retrieve clot debris. The low invasiveness is attributed to the soft material design and conservative actuation strategy. The performance of the MSRM is validated in both in vitro phantom studies and in vivo rabbit models, and the invasiveness is evaluated using a human placenta model.
- Open Access
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 1513-1532
Magnetic Continuum Robot With Modular Axial Magnetization: Design, Modeling, Optimization, and Control
Magnetic continuum robots (MCRs) have become popular owing to their inherent advantages of easy miniaturization without requiring complicated transmission structures. The evolution of MCRs, from initial designs with one embedded magnet to current designs with specific magnetization profile configurations (MPCs), has significantly enhanced their dexterity. While much progress has been achieved, the quantitative index-based evaluation of deformability for different MPCs, which can assist in designing MPCs with enhanced robot deformability, has not been addressed before. Here we use “deformability” to describe the capability for body deflection when an MCR forms different global shapes under an external magnetic field. Therefore, in this paper, we propose methodologies to design and control an MCR composed of modular axially magnetized segments. To guide robot MPC design, for the first time, we introduce a quantitative index-based evaluation strategy to analyze and optimize robot deformability. Additionally, a control framework with neural network-based controllers is developed to endow the robot with two control modes: the robot tip position and orientation ( $M_{1}$ ) and the global shape ( $M_{2}$ ). The excellent performance of the learnt controllers in terms of computation time and accuracy was validated via both simulation and experimental platforms. In the experimental results, the best closed-loop control performance metrics, indicated as the mean absolute errors, were 0.254 mm and 0.626 $^\circ$ for mode $M_{1}$ and 1.564 mm and 0.086 $^\circ$ for mode $M_{2}$ .
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 1513-1532
Open AccessMagnetic Continuum Robot With Modular Axial Magnetization: Design, Modeling, Optimization, and Control
Magnetic continuum robots (MCRs) have become popular owing to their inherent advantages of easy miniaturization without requiring complicated transmission structures. The evolution of MCRs, from initial designs with one embedded magnet to current designs with specific magnetization profile configurations (MPCs), has significantly enhanced their dexterity. While much progress has been achieved, the quantitative index-based evaluation of deformability for different MPCs, which can assist in designing MPCs with enhanced robot deformability, has not been addressed before. Here we use “deformability” to describe the capability for body deflection when an MCR forms different global shapes under an external magnetic field. Therefore, in this paper, we propose methodologies to design and control an MCR composed of modular axially magnetized segments. To guide robot MPC design, for the first time, we introduce a quantitative index-based evaluation strategy to analyze and optimize robot deformability. Additionally, a control framework with neural network-based controllers is developed to endow the robot with two control modes: the robot tip position and orientation ( $M_{1}$ ) and the global shape ( $M_{2}$ ). The excellent performance of the learnt controllers in terms of computation time and accuracy was validated via both simulation and experimental platforms. In the experimental results, the best closed-loop control performance metrics, indicated as the mean absolute errors, were 0.254 mm and 0.626 $^\circ$ for mode $M_{1}$ and 1.564 mm and 0.086 $^\circ$ for mode $M_{2}$ .
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 3676-3694
Automated Microrobotic Manipulation Using Reconfigurable Magnetic Microswarms
Untethered microrobots possess a promising perspective for micro-manipulation applications. With specifically designed morphologies and structures, microrobots are able to perform controllable delivery of target objects. However, the manipulation process still lacks autonomy, to achieve which the mechanism of picking, transporting, and releasing behaviors needs further investigation. In this paper, we propose to achieve automated microrobotic manipulation using magnetic microswarms with multimodal morphology. The microswarm is composed of around 11 $\sim$ 21 million $\text{Fe}_{3}\mathrm{O}_{4}$ nanoparticles (1.0 $\sim 1.8 \mu$ L particle suspension). When exposed to different dynamic magnetic fields, the swarm could exhibit corresponding forms. We realize precise and controllable cargo picking and releasing by exploiting the fluid fields of different swarm forms. In order to quantitatively describe these behaviors, we design a finite state machine (FSM). A super-twisting sliding mode controller (STSMC) has been formulated for the motion control of swarms. The disturbances are compensated via a disturbance observer (DOB). To enable automated micro-manipulation in obstructed scenarios, a path planner inspired by rapidly exploring random tree (RRT) algorithm is designed for path planning when obstacles exist. We also propose an enhanced-genetic algorithm (e-GA) to optimally transport multiple objects to the target position. Experiments demonstrate that our method could effectively transport micro-objects with different sizes and shapes. The precise selectivity of the method is validated when multiple objects exist in the working environment. Finally, the long-distance delivery ability and adaptivity to various friction situations of our strategy are demonstrated. This work explores a concise, untethered, and automated micro-manipulation strategy, provides a new automatic tool for micro-manipulation tasks, and extends the application potential of swarm microrobotics.
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 3676-3694
Automated Microrobotic Manipulation Using Reconfigurable Magnetic Microswarms
Untethered microrobots possess a promising perspective for micro-manipulation applications. With specifically designed morphologies and structures, microrobots are able to perform controllable delivery of target objects. However, the manipulation process still lacks autonomy, to achieve which the mechanism of picking, transporting, and releasing behaviors needs further investigation. In this paper, we propose to achieve automated microrobotic manipulation using magnetic microswarms with multimodal morphology. The microswarm is composed of around 11 $\sim$ 21 million $\text{Fe}_{3}\mathrm{O}_{4}$ nanoparticles (1.0 $\sim 1.8 \mu$ L particle suspension). When exposed to different dynamic magnetic fields, the swarm could exhibit corresponding forms. We realize precise and controllable cargo picking and releasing by exploiting the fluid fields of different swarm forms. In order to quantitatively describe these behaviors, we design a finite state machine (FSM). A super-twisting sliding mode controller (STSMC) has been formulated for the motion control of swarms. The disturbances are compensated via a disturbance observer (DOB). To enable automated micro-manipulation in obstructed scenarios, a path planner inspired by rapidly exploring random tree (RRT) algorithm is designed for path planning when obstacles exist. We also propose an enhanced-genetic algorithm (e-GA) to optimally transport multiple objects to the target position. Experiments demonstrate that our method could effectively transport micro-objects with different sizes and shapes. The precise selectivity of the method is validated when multiple objects exist in the working environment. Finally, the long-distance delivery ability and adaptivity to various friction situations of our strategy are demonstrated. This work explores a concise, untethered, and automated micro-manipulation strategy, provides a new automatic tool for micro-manipulation tasks, and extends the application potential of swarm microrobotics.
- Open Access
- 23 December 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-14
Exploiting ferrofluidic wetting for miniature soft machines
Miniature magnetic soft machines could significantly impact minimally invasive robotics and biomedical applications. However, most soft machines are limited to solid magnetic materials, whereas further progress also relies on fluidic constructs obtained by reconfiguring liquid magnetic materials, such as ferrofluid. Here we show how harnessing the wettability of ferrofluids allows for controlled reconfigurability and the ability to create versatile soft machines. The ferrofluid droplet exhibits multimodal motions, and a single droplet can be controlled to split into multiple sub-droplets and then re-fuse back on demand. The soft droplet machine can negotiate changing terrains in unstructured environments. In addition, the ferrofluid droplets can be configured as a liquid capsule, enabling cargo delivery; a wireless omnidirectional liquid cilia matrix capable of pumping biofluids; and a wireless liquid skin, allowing multiple types of miniature soft machine construction. This work improves small magnetic soft machines’ achievable complexity and boosts their future biomedical applications capabilities.
- 23 December 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-14
Open AccessExploiting ferrofluidic wetting for miniature soft machines
Miniature magnetic soft machines could significantly impact minimally invasive robotics and biomedical applications. However, most soft machines are limited to solid magnetic materials, whereas further progress also relies on fluidic constructs obtained by reconfiguring liquid magnetic materials, such as ferrofluid. Here we show how harnessing the wettability of ferrofluids allows for controlled reconfigurability and the ability to create versatile soft machines. The ferrofluid droplet exhibits multimodal motions, and a single droplet can be controlled to split into multiple sub-droplets and then re-fuse back on demand. The soft droplet machine can negotiate changing terrains in unstructured environments. In addition, the ferrofluid droplets can be configured as a liquid capsule, enabling cargo delivery; a wireless omnidirectional liquid cilia matrix capable of pumping biofluids; and a wireless liquid skin, allowing multiple types of miniature soft machine construction. This work improves small magnetic soft machines’ achievable complexity and boosts their future biomedical applications capabilities.
- 5 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (2) , 744-752
Numerical Analysis and Experimental Investigation on a Novel Piezoelectric-Actuated Rail-Type Mobile Platform
A novel piezoelectric-actuated rail-type mobile platform is proposed in this article, which has potential application in the inspection and maintenance tasks of the Tokamak vacuum vessel as it holds good environmental adaptability to extreme environments, such as strong magnetic fields, high vacuum, and high temperature. The rail-type piezoelectric-actuated mobile platform consists of a rail and a framed piezoelectric actuator operating with two orthogonal bending vibrations. The framed piezoelectric actuator moves on the rail by friction. At first, a semianalytical model is created for the framed piezoelectric actuator utilizing the transfer matrix method in order to reveal its dynamic behavior. Then, the prototype of the proposed framed piezoelectric actuator is manufactured and assembled, and its vibration characteristics are measured to verify the feasibility of the developed transfer matrix model. Additionally, the mechanical output performances of the rail-type mobile platform prototype are investigated experimentally, and it is observed that the maximum speed of the mobile platform prototype reached 384.68 mm/s when the amplitude of the driving voltage is 400 V pp , its maximum load-weight to self-weight ratio reached 7.6 when the excitation voltage is 300 V pp , its maximum output force is about 1.8 N under the excitation voltage of 400 V pp , and the minimum displacement resolution is 4 μ m when operated in the stepping mode. Finally, the extreme environment (temperature: 0–120 °C and vacuum: 3×10 −3 –10 5 Pa) tests are carried out to measure the output performances of the mobile platform prototype. The results show that the platform prototype is capable of carrying loads in a high-temperature and high-vacuum environment.
- 5 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (2) , 744-752
Numerical Analysis and Experimental Investigation on a Novel Piezoelectric-Actuated Rail-Type Mobile Platform
A novel piezoelectric-actuated rail-type mobile platform is proposed in this article, which has potential application in the inspection and maintenance tasks of the Tokamak vacuum vessel as it holds good environmental adaptability to extreme environments, such as strong magnetic fields, high vacuum, and high temperature. The rail-type piezoelectric-actuated mobile platform consists of a rail and a framed piezoelectric actuator operating with two orthogonal bending vibrations. The framed piezoelectric actuator moves on the rail by friction. At first, a semianalytical model is created for the framed piezoelectric actuator utilizing the transfer matrix method in order to reveal its dynamic behavior. Then, the prototype of the proposed framed piezoelectric actuator is manufactured and assembled, and its vibration characteristics are measured to verify the feasibility of the developed transfer matrix model. Additionally, the mechanical output performances of the rail-type mobile platform prototype are investigated experimentally, and it is observed that the maximum speed of the mobile platform prototype reached 384.68 mm/s when the amplitude of the driving voltage is 400 V pp , its maximum load-weight to self-weight ratio reached 7.6 when the excitation voltage is 300 V pp , its maximum output force is about 1.8 N under the excitation voltage of 400 V pp , and the minimum displacement resolution is 4 μ m when operated in the stepping mode. Finally, the extreme environment (temperature: 0–120 °C and vacuum: 3×10 −3 –10 5 Pa) tests are carried out to measure the output performances of the mobile platform prototype. The results show that the platform prototype is capable of carrying loads in a high-temperature and high-vacuum environment.