Tiejun Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tiejun Pan has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Bo Liu
Department of Urology, Central Theater General Hospital, Wuhan, China
2 shared publicationsLeina Zheng
Zhejiang Wanli College
2 shared publications- Shouzhen Zeng
Ningbo University, China
2 shared publications - Bo Peng
Southwest Petroleum University, School of Computer Science and Software Engineering, Chengdu, China
1 shared publication - Changbao Xu
Department of Urology, The Second Affiliated Hospital of Zhengzhou University Zhengzhou, Zhengzhou, China
1 shared publication - Chonghui Zhang
School of Statistics and Mathematics Zhejiang Gongshang University Hangzhou China
1 shared publication
Latest Publications
- Open Access
- 18 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 40429
SHP1 overexpression ameliorates renal fibrosis via inhibition of STAT3 signaling and glycolysis reprogramming
This study aimed to clarify the role of tyrosine phosphatase SHP-1 on renal fibrosis and its underlying mechanisms. We used a unilateral ureteral obstruction (UUO) rat model to simulate renal fibrosis and achieved overexpression of SHP-1 through lentivirus injection. The effects of overexpression of SHP-1 on extracellular matrix (ECM) deposition, fibrosis degree and key indicators of glycolysis in renal tissue were evaluated. Results showed that overexpression of SHP-1 significantly alleviated renal fibrosis and ECM accumulation induced by UUO. SHP-1 overexpression reduced α-SMA, FN, collagen I, III, HK, PKM2, Bax expression, and lactate levels, while increasing glucose uptake and Bcl-2 expression. Bioinformatics analysis has shown that the transcription factors FOXO (FoxO3a and FoxO1) are downstream targets of the STAT3 signaling pathway, jointly regulating the glycolysis/gluconeogenesis pathway. Overexpression of SHP-1 effectively inhibited the phosphorylation of STAT3 (p-STAT3) and the expression of downstream FoxO3a/FoxO1. Mechanism studies have shown that overexpression of SHP-1 inhibits the STAT3 signaling pathway, generating effects similar to those of glycolytic inhibitors: inhibiting glycolysis, promoting cell proliferation, reducing cell apoptosis and collagen deposition, thereby alleviating renal fibrosis. In conclusion, overexpression of SHP-1 can effectively alleviate the progression of renal fibrosis by inhibiting the STAT3/FOXO signaling axis and its mediated glycolytic reprogramming. This provides new experimental evidence for the development of anti-fibrotic therapies targeting SHP-1.
- 18 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 40429
Open AccessSHP1 overexpression ameliorates renal fibrosis via inhibition of STAT3 signaling and glycolysis reprogramming
This study aimed to clarify the role of tyrosine phosphatase SHP-1 on renal fibrosis and its underlying mechanisms. We used a unilateral ureteral obstruction (UUO) rat model to simulate renal fibrosis and achieved overexpression of SHP-1 through lentivirus injection. The effects of overexpression of SHP-1 on extracellular matrix (ECM) deposition, fibrosis degree and key indicators of glycolysis in renal tissue were evaluated. Results showed that overexpression of SHP-1 significantly alleviated renal fibrosis and ECM accumulation induced by UUO. SHP-1 overexpression reduced α-SMA, FN, collagen I, III, HK, PKM2, Bax expression, and lactate levels, while increasing glucose uptake and Bcl-2 expression. Bioinformatics analysis has shown that the transcription factors FOXO (FoxO3a and FoxO1) are downstream targets of the STAT3 signaling pathway, jointly regulating the glycolysis/gluconeogenesis pathway. Overexpression of SHP-1 effectively inhibited the phosphorylation of STAT3 (p-STAT3) and the expression of downstream FoxO3a/FoxO1. Mechanism studies have shown that overexpression of SHP-1 inhibits the STAT3 signaling pathway, generating effects similar to those of glycolytic inhibitors: inhibiting glycolysis, promoting cell proliferation, reducing cell apoptosis and collagen deposition, thereby alleviating renal fibrosis. In conclusion, overexpression of SHP-1 can effectively alleviate the progression of renal fibrosis by inhibiting the STAT3/FOXO signaling axis and its mediated glycolytic reprogramming. This provides new experimental evidence for the development of anti-fibrotic therapies targeting SHP-1.
- Open Access
- 28 March 2025
- Published by Frontiers Media SA in Frontiers in Nutrition
- Vol. 12, 1534309
Joint and individual associations between multiple vitamins and sperm quality in adult men
Background: Several studies have suggested that a healthy diet is associated with improved male fertility outcomes. However, the joint and individual associations between the status of multiple vitamins and sperm quality remain unclear.Objectives: This study aimed to investigate the associations between serum vitamin levels and sperm quality parameters in adult men.Methods: A cross-sectional study was conducted among 156 adult men seeking fertility care at a reproductive center from December 2023 to June 2024. Blood and semen were collected on the same day to determine the concentrations of nine kinds of vitamins (B1, B2, B6, B9, B12, C, A, D, E) and five parameters of sperm quality [total sperm number, sperm concentration, progressive motile sperm, morphologically normal rate, and DNA fragment index (DFI)]. The joint and individual associations between vitamin levels and sperm quality were analyzed using multiple linear regression and Bayesian kernel machine regression (BKMR) models.Results: Increased tertiles of vitamin B1 and 1,25-dihydroxyvitamin D3 [1,25–(OH)2-D3] in serum were associated with higher sperm quality (all P for trends < 0.10). Compared with the lowest tertiles, the highest tertiles of vitamin B12 had β: 3.0 (95% CI: 0.8, 5.2) increasing in DFI, and vitamin A was negatively associated with progressive sperm motility (P for trends = 0.05). We generally found null results between multiple vitamin levels and the parameters of sperm quality in the BKMR models.Discussion: These research findings imply that vitamins could have a dose-dependent dual effect on sperm quality. More specifically, the impact of vitamins varies according to their dosage levels and types. Personalized vitamin supplementation may be more effective than taking multivitamins in improving sperm quality.
- 28 March 2025
- Published by Frontiers Media SA in Frontiers in Nutrition
- Vol. 12, 1534309
Open AccessJoint and individual associations between multiple vitamins and sperm quality in adult men
Background: Several studies have suggested that a healthy diet is associated with improved male fertility outcomes. However, the joint and individual associations between the status of multiple vitamins and sperm quality remain unclear.Objectives: This study aimed to investigate the associations between serum vitamin levels and sperm quality parameters in adult men.Methods: A cross-sectional study was conducted among 156 adult men seeking fertility care at a reproductive center from December 2023 to June 2024. Blood and semen were collected on the same day to determine the concentrations of nine kinds of vitamins (B1, B2, B6, B9, B12, C, A, D, E) and five parameters of sperm quality [total sperm number, sperm concentration, progressive motile sperm, morphologically normal rate, and DNA fragment index (DFI)]. The joint and individual associations between vitamin levels and sperm quality were analyzed using multiple linear regression and Bayesian kernel machine regression (BKMR) models.Results: Increased tertiles of vitamin B1 and 1,25-dihydroxyvitamin D3 [1,25–(OH)2-D3] in serum were associated with higher sperm quality (all P for trends < 0.10). Compared with the lowest tertiles, the highest tertiles of vitamin B12 had β: 3.0 (95% CI: 0.8, 5.2) increasing in DFI, and vitamin A was negatively associated with progressive sperm motility (P for trends = 0.05). We generally found null results between multiple vitamin levels and the parameters of sperm quality in the BKMR models.Discussion: These research findings imply that vitamins could have a dose-dependent dual effect on sperm quality. More specifically, the impact of vitamins varies according to their dosage levels and types. Personalized vitamin supplementation may be more effective than taking multivitamins in improving sperm quality.
- 19 December 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 43 (1) , 1-8
Novel pressure- and temperature-controlled flexible ureteroscope system with a suction ureteral access sheath: a multicenter retrospective feasibility study
Purpose The purpose of this study was to assess the feasibility of a pressure-controlled and temperature-controlled flexible ureteroscope system (PT Scope™) during flexible ureteroscopy. Materials and methods We developed the PT Scope™, a novel ureteroscope system with capabilities for monitoring and controlling intrarenal pressure and temperature to maintain them within set parameters. Data were retrospectively collected from 48 consecutive patients diagnosed with upper urinary tract stones who underwent flexible ureteroscopic lithotripsy using the PT Scope™ across five centers in China. Analyses focused on 24-h postoperative stone-free rates, intrarenal pressure and temperature measurements, and other procedural data. Results Among the 48 patients treated with the PT Scope™ system, a significant stone-free rate of 89.6% was achieved within 24 h postoperation, without any instances of intraoperative complications such as perforation or mucosal hemorrhage. Only two patients reported mild postoperative pain and were managed with NSAIDs, and there were no cases of postoperative fever or sepsis. The average maximum intrarenal pressure and temperature were recorded at 30.2 ± 4.20 mmHg and 36.6 ± 4.27 °C, respectively. Notably, during lithotripsy, both the pressure and temperature were maintained below 30 mmHg and 43 °C for 99% of the procedure duration, respectively. Conclusion This preliminary investigation indicates that the PT Scope™ is a safe and effective tool for the treatment of upper urinary tract stones, offering the benefit of regulating intrarenal pressure and temperature within predetermined limits. These findings support the feasibility of the system for clinical application.
- 19 December 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 43 (1) , 1-8
Novel pressure- and temperature-controlled flexible ureteroscope system with a suction ureteral access sheath: a multicenter retrospective feasibility study
Purpose The purpose of this study was to assess the feasibility of a pressure-controlled and temperature-controlled flexible ureteroscope system (PT Scope™) during flexible ureteroscopy. Materials and methods We developed the PT Scope™, a novel ureteroscope system with capabilities for monitoring and controlling intrarenal pressure and temperature to maintain them within set parameters. Data were retrospectively collected from 48 consecutive patients diagnosed with upper urinary tract stones who underwent flexible ureteroscopic lithotripsy using the PT Scope™ across five centers in China. Analyses focused on 24-h postoperative stone-free rates, intrarenal pressure and temperature measurements, and other procedural data. Results Among the 48 patients treated with the PT Scope™ system, a significant stone-free rate of 89.6% was achieved within 24 h postoperation, without any instances of intraoperative complications such as perforation or mucosal hemorrhage. Only two patients reported mild postoperative pain and were managed with NSAIDs, and there were no cases of postoperative fever or sepsis. The average maximum intrarenal pressure and temperature were recorded at 30.2 ± 4.20 mmHg and 36.6 ± 4.27 °C, respectively. Notably, during lithotripsy, both the pressure and temperature were maintained below 30 mmHg and 43 °C for 99% of the procedure duration, respectively. Conclusion This preliminary investigation indicates that the PT Scope™ is a safe and effective tool for the treatment of upper urinary tract stones, offering the benefit of regulating intrarenal pressure and temperature within predetermined limits. These findings support the feasibility of the system for clinical application.
- Open Access
- 1 January 2022
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 2022 (1) , 4107491
The Function Improved of the Newly Designed Magnetic‐End Ureteric Stenting Retrieval Device: A Clinical Prospective Randomized and Control Trial in a Multicenter Study
Objective. To demonstrate the advantage of our newly designed magnetic ureteric stenting retrieval device over traditional nonmagnetic ureteric stents and other retrieval devices without cystoscopy intervention on clinical application and cost‐related outcomes. Patients and Methods. A total of 333 patients were recruited into two study groups: magnetic‐end ureteral stent (Group A) and conventional ureteral stent (Group B). The effects were evaluated by Ureteral Stent Symptom Questionnaire (USSQ) scores, complications of the indwelling stent, visual analog scale (VAS) pain scores at stent removal, and cost‐analysis outcomes between the magnetic ureteric stenting retrieval device and traditional double‐J ureteral stent (DJUS) removed by cystoscopy. Results. The VAS of the pain score of patients undergoing magnetic stent removal with the retrieval device was 2 ± 0.97, whereas that of patients undergoing conventional ureteral stent removal with cystoscopy was 5.76 ± 1.53 (p < 0.001). The removal of magnetic stents by a retrieval device proved to be less painful than cystoscopy‐mediated stent removal (p < 0.001). Obviously, the total cost for the magnetic stent removal was much lower than the conventional ureteral stent removal, although the magnetic stent costs more than the conventional ureteral stent. The improved magnetic stent used in our study showed a remarkable cost saving of 705/111 USD Chinese Yuan (CNY) per patient when compared with the conventional ureteral stent. Conclusion. We reported the integrated design features of the improved magnetic stent in the world, which was granted a patent in China. USSQ scores and rate of complications in the magnetic stent were as equally acceptable as a conventional stent. Furthermore, successful stent insertion rate reached 100% by both the antegrade and retrograde approaches, and no failure case of magnetic stent removal was reported in our study.
- 1 January 2022
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 2022 (1) , 4107491
Open AccessThe Function Improved of the Newly Designed Magnetic‐End Ureteric Stenting Retrieval Device: A Clinical Prospective Randomized and Control Trial in a Multicenter Study
Objective. To demonstrate the advantage of our newly designed magnetic ureteric stenting retrieval device over traditional nonmagnetic ureteric stents and other retrieval devices without cystoscopy intervention on clinical application and cost‐related outcomes. Patients and Methods. A total of 333 patients were recruited into two study groups: magnetic‐end ureteral stent (Group A) and conventional ureteral stent (Group B). The effects were evaluated by Ureteral Stent Symptom Questionnaire (USSQ) scores, complications of the indwelling stent, visual analog scale (VAS) pain scores at stent removal, and cost‐analysis outcomes between the magnetic ureteric stenting retrieval device and traditional double‐J ureteral stent (DJUS) removed by cystoscopy. Results. The VAS of the pain score of patients undergoing magnetic stent removal with the retrieval device was 2 ± 0.97, whereas that of patients undergoing conventional ureteral stent removal with cystoscopy was 5.76 ± 1.53 (p < 0.001). The removal of magnetic stents by a retrieval device proved to be less painful than cystoscopy‐mediated stent removal (p < 0.001). Obviously, the total cost for the magnetic stent removal was much lower than the conventional ureteral stent removal, although the magnetic stent costs more than the conventional ureteral stent. The improved magnetic stent used in our study showed a remarkable cost saving of 705/111 USD Chinese Yuan (CNY) per patient when compared with the conventional ureteral stent. Conclusion. We reported the integrated design features of the improved magnetic stent in the world, which was granted a patent in China. USSQ scores and rate of complications in the magnetic stent were as equally acceptable as a conventional stent. Furthermore, successful stent insertion rate reached 100% by both the antegrade and retrograde approaches, and no failure case of magnetic stent removal was reported in our study.
- 18 January 2021
- Published by SAGE Publications in Journal of Intelligent & Fuzzy Systems: Applications in Engineering and Technology
- Vol. 41 (3) , 4237-4251
The research and application of intuitionistic fuzzy decision making
This paper studies intuitionistic fuzzy (IF) decision making problems using an integrated approach. Firstly, an IF induced generalized ordered weighted averaging distance (IFIGOWAD) operator is introduced, that covers numerous IF aggregations distance operators. Then, two more generalized operators named IF quasi induced OWAD (Quasi-IFIOWAD) and IF induced generalized hybrid average distance (IFIGHAD) operator are presented. Furthermore, a new method using above operators is introduced to IF decision making problem and online trade systems. Finally, two real cases are present to show the effect of the method.
- 18 January 2021
- Published by SAGE Publications in Journal of Intelligent & Fuzzy Systems: Applications in Engineering and Technology
- Vol. 41 (3) , 4237-4251
The research and application of intuitionistic fuzzy decision making
This paper studies intuitionistic fuzzy (IF) decision making problems using an integrated approach. Firstly, an IF induced generalized ordered weighted averaging distance (IFIGOWAD) operator is introduced, that covers numerous IF aggregations distance operators. Then, two more generalized operators named IF quasi induced OWAD (Quasi-IFIOWAD) and IF induced generalized hybrid average distance (IFIGHAD) operator are presented. Furthermore, a new method using above operators is introduced to IF decision making problem and online trade systems. Finally, two real cases are present to show the effect of the method.
- 21 October 2017
- Published by Springer Nature
- p. 493-500
Induced Generalized Intuitionistic Fuzzy Aggregation Distance Operators and Their Application to Decision Making
- 21 October 2017
- Published by Springer Nature
- p. 493-500
Induced Generalized Intuitionistic Fuzzy Aggregation Distance Operators and Their Application to Decision Making
- 21 October 2017
- Published by Springer Nature
- p. 501-508
New 2-Tuple Linguistic Aggregation Distance Operator and Its Application to Information Systems Security Assessment
- 21 October 2017
- Published by Springer Nature
- p. 501-508
New 2-Tuple Linguistic Aggregation Distance Operator and Its Application to Information Systems Security Assessment
- 22 April 2013
- Published by Wiley in International Transactions in Operational Research
- Vol. 20 (4) , 579-594
A method for fuzzy group decision making based on induced aggregation operators and Euclidean distance
In this paper, we present the fuzzy‐induced Euclidean ordered weighted averaging distance (FIEOWAD) operator. It is an extension of the ordered weighted averaging (OWA) operator that uses the main characteristics of the induced OWA (IOWA), the Euclidean distance and uncertain information represented by fuzzy numbers. The main advantage of this operator is that it is able to consider complex attitudinal characters of the decision maker by using order‐inducing variables in the aggregation of the Euclidean distance. Moreover, it is able to deal with uncertain environments where the information is very imprecise and can be assessed with fuzzy numbers. We study some of its main properties and particular cases such as the fuzzy maximum distance, fuzzy minimum distance, fuzzy‐normalized Euclidean distance (FNED), fuzzy‐weighted Euclidean distance (FWED), and fuzzy Euclidean ordered weighted averaging distance (FEOWAD) operator. Finally, we present an application of the operator to a group decision‐making problem concerning the selection of strategies.
- 22 April 2013
- Published by Wiley in International Transactions in Operational Research
- Vol. 20 (4) , 579-594
A method for fuzzy group decision making based on induced aggregation operators and Euclidean distance
In this paper, we present the fuzzy‐induced Euclidean ordered weighted averaging distance (FIEOWAD) operator. It is an extension of the ordered weighted averaging (OWA) operator that uses the main characteristics of the induced OWA (IOWA), the Euclidean distance and uncertain information represented by fuzzy numbers. The main advantage of this operator is that it is able to consider complex attitudinal characters of the decision maker by using order‐inducing variables in the aggregation of the Euclidean distance. Moreover, it is able to deal with uncertain environments where the information is very imprecise and can be assessed with fuzzy numbers. We study some of its main properties and particular cases such as the fuzzy maximum distance, fuzzy minimum distance, fuzzy‐normalized Euclidean distance (FNED), fuzzy‐weighted Euclidean distance (FWED), and fuzzy Euclidean ordered weighted averaging distance (FEOWAD) operator. Finally, we present an application of the operator to a group decision‐making problem concerning the selection of strategies.