Muhammed Alpay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Muhammed Alpay has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ahmet Taha Karakuzu
Department of Otolaryngology, University of Health Sciences, Kocaeli City Hospital
2 shared publications - Fatih Ozdogan
Department of Otolaryngology, University of Health Sciences, Kocaeli City Hospital
2 shared publications - Halil Erdem Özel
Department of Otolaryngology, University of Health Sciences Derince Research and Training Hospital, Kocaeli, Turkey
2 shared publications - Hümeyra Temir
Department of Audiology, University of Health Sciences, Kocaeli City Hospital
2 shared publications - Selahattin Genç
Department of Otolaryngology, University of Health Sciences, Kocaeli City Hospital
2 shared publications - Sebla Çalışkan
Department of Otolaryngology, University of Health Sciences, Kocaeli City Hospital
1 shared publication
Latest Publications
- 6 October 2025
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 65 (1) , 63-70
Towards an optimized monothermal caloric screening test: comparing stimuli and thresholds
Monothermal caloric testing (MCT) shows potential as a screening method in vestibular assessment; however, the optimal stimulus modality and diagnostic threshold remain unclear. This study aimed to identify, within a single investigation, the most effective stimulus type (air or water; warm or cool) and the optimal cut-off threshold (15% or 25%) for maximising the diagnostic performance of MCT. Retrospective study. Bithermal caloric test (BCT) results from 202 adults (103 water, 99 air) were analysed. MCT results were assessed at 15% and 25% thresholds based on sensitivity, specificity, and overall diagnostic accuracy, using BCT as the reference standard. Warm stimuli demonstrated higher sensitivity, with warm air yielding the highest value (86.7%), while cool stimuli showed greater specificity, with cool water reaching the highest specificity (78.7%) at the 25% threshold. Warm air MCT resulted in the lowest false negative rate (6%) and highest diagnostic accuracy (94%), reducing the need for BCT to 57.6% of patients. Lowering the threshold to 15% slightly improved accuracy (95.9%) but increased BCT referrals (64.6%). Warm air MCT appears to be an efficient screening tool for detecting unilateral vestibular weakness, offering high diagnostic accuracy while potentially reducing the need for comprehensive BCT.
- 6 October 2025
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 65 (1) , 63-70
Towards an optimized monothermal caloric screening test: comparing stimuli and thresholds
Monothermal caloric testing (MCT) shows potential as a screening method in vestibular assessment; however, the optimal stimulus modality and diagnostic threshold remain unclear. This study aimed to identify, within a single investigation, the most effective stimulus type (air or water; warm or cool) and the optimal cut-off threshold (15% or 25%) for maximising the diagnostic performance of MCT. Retrospective study. Bithermal caloric test (BCT) results from 202 adults (103 water, 99 air) were analysed. MCT results were assessed at 15% and 25% thresholds based on sensitivity, specificity, and overall diagnostic accuracy, using BCT as the reference standard. Warm stimuli demonstrated higher sensitivity, with warm air yielding the highest value (86.7%), while cool stimuli showed greater specificity, with cool water reaching the highest specificity (78.7%) at the 25% threshold. Warm air MCT resulted in the lowest false negative rate (6%) and highest diagnostic accuracy (94%), reducing the need for BCT to 57.6% of patients. Lowering the threshold to 15% slightly improved accuracy (95.9%) but increased BCT referrals (64.6%). Warm air MCT appears to be an efficient screening tool for detecting unilateral vestibular weakness, offering high diagnostic accuracy while potentially reducing the need for comprehensive BCT.
- 19 April 2022
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 62 (7) , 644-649
Effect of ocular fixation on positional nystagmus in BPPV patients
The quantitative suppression rate of positional nystagmus (PN) by ocular fixation (OF) is unknown. This study aims to analyse the effect of OF on the slow phase velocity (SPV) of PN during diagnost...
- 19 April 2022
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 62 (7) , 644-649
Effect of ocular fixation on positional nystagmus in BPPV patients
The quantitative suppression rate of positional nystagmus (PN) by ocular fixation (OF) is unknown. This study aims to analyse the effect of OF on the slow phase velocity (SPV) of PN during diagnost...