Wanliang Fang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wanliang Fang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Jun Liu
Xi’an Jiaotong University
2 shared publications Shuanbao Niu
Northwest Subsection of State Grid Corporation of China
2 shared publicationsXu Wang
Xi’an Jiaotong University
2 shared publicationsCan Su
Shaanxi Key Laboratory of Smart Grid School of Electrical Engineering Xi'an Jiaotong University Xi'an Shaanxi 710049 People's Republic of China
1 shared publicationLin Cheng
Northwest Subsection of State Grid Corporation of China Xi'an 710048 People's Republic of China
1 shared publicationXudong Hao
Xi’an Jiaotong University
1 shared publication
Latest Publications
- Open Access
- 7 February 2018
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 6 (4) , 821-832
Application of thyristor controlled phase shifting transformer excitation impedance switching control to suppress short-circuit fault current level
- 7 February 2018
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 6 (4) , 821-832
Open AccessApplication of thyristor controlled phase shifting transformer excitation impedance switching control to suppress short-circuit fault current level
- Open Access
- 19 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 1040-1044
Abnormality in power system transient stability control of BESS/STATCOM
To solve energy and environment crisis, large amounts of renewable energy power generation has been integrated to modern power grids, resulting in power quality decline, frequency fluctuation, and stability deterioration. In this case, advanced control and regulation means for power systems are needed. Static synchronous compensator (STATCOM) is a shunt‐connected flexible AC transmission system device that is often used for reactive power control. When associated with battery energy storage systems (BESSs), the adjustment capabilities of STATCOM can be extended to four quadrants. Therefore, the hybrid BESS/STATCOM can influence modern power system operation. A system‐level electromechanical transient mathematical model for BESS/STATCOM is established, based on the circuit structure of battery, three‐phase bridge converter and a low‐pass filter. Then, a typical real and reactive power coordinated control strategy based on the double‐loop scheme is developed for BESS/STATCOM. Finally, the influence of BESS/STATCOM on the system's transient stability is tested, according to simulations conducted on IEEE 3‐machine 9‐bus standard system. Simulation results show that BESS/STATCOM can improve the transient stability under charging state, but abnormality has been found that BESS/STATCOM might not alleviate the angle stability and voltage drop as much as those in the discharging state.
- 19 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 1040-1044
Open AccessAbnormality in power system transient stability control of BESS/STATCOM
To solve energy and environment crisis, large amounts of renewable energy power generation has been integrated to modern power grids, resulting in power quality decline, frequency fluctuation, and stability deterioration. In this case, advanced control and regulation means for power systems are needed. Static synchronous compensator (STATCOM) is a shunt‐connected flexible AC transmission system device that is often used for reactive power control. When associated with battery energy storage systems (BESSs), the adjustment capabilities of STATCOM can be extended to four quadrants. Therefore, the hybrid BESS/STATCOM can influence modern power system operation. A system‐level electromechanical transient mathematical model for BESS/STATCOM is established, based on the circuit structure of battery, three‐phase bridge converter and a low‐pass filter. Then, a typical real and reactive power coordinated control strategy based on the double‐loop scheme is developed for BESS/STATCOM. Finally, the influence of BESS/STATCOM on the system's transient stability is tested, according to simulations conducted on IEEE 3‐machine 9‐bus standard system. Simulation results show that BESS/STATCOM can improve the transient stability under charging state, but abnormality has been found that BESS/STATCOM might not alleviate the angle stability and voltage drop as much as those in the discharging state.