Wanru Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wanru Chang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Jianfeng Zhang
College of Mathematical Medicine, Zhejiang Normal University, Jinhua, China
4 shared publications C.S. Chen
2 shared publications- Dexing Kong
Zhejiang University
2 shared publications - Lei Xu
School of Electronic and Communication Engineering, Shenzhen Polytechnic University , Shenzhen, 518055
2 shared publications Chanjuan Peng
Department of Ultrasonography, The Cancer Hospital of the University of Chinese Academy of Sciences (Zhejiang Cancer Hospital), Institute of Basic Medicine and Cancer, Chinese Academy of Sciences, Hangzhou, China
1 shared publicationChen Yang
Department of Ultrasonography, The Cancer Hospital of the University of Chinese Academy of Sciences (Zhejiang Cancer Hospital), Institute of Basic Medicine and Cancer, Chinese Academy of Sciences, Hangzhou, China
1 shared publication
Latest Publications
- 2 July 2026
- Published by Springer Nature
- p. 210-223
Efficient and Nearly Lossless 3D MRI Reconstruction via Hyper-Sparse Encoding and QR Factorization
- 2 July 2026
- Published by Springer Nature
- p. 210-223
Efficient and Nearly Lossless 3D MRI Reconstruction via Hyper-Sparse Encoding and QR Factorization
- Open Access
- 31 October 2022
- Published by Frontiers Media SA in Frontiers in Endocrinology
- Vol. 13, 981403
An artificial intelligence ultrasound system’s ability to distinguish benign from malignant follicular-patterned lesions
Objectives: To evaluate the application value of a generally trained artificial intelligence (AI) automatic diagnosis system in the malignancy diagnosis of follicular-patterned thyroid lesions (FPTL), including follicular thyroid carcinoma (FTC), adenomatoid hyperplasia nodule (AHN) and follicular thyroid adenoma (FTA) and compare the diagnostic performance with radiologists of different experience levels.Methods: We retrospectively reviewed 607 patients with 699 thyroid nodules that included 168 malignant nodules by using postoperative pathology as the gold standard, and compared the diagnostic performances of three radiologists (one junior, two senior) and that of AI automatic diagnosis system in malignancy diagnosis of FPTL in terms of sensitivity, specificity and accuracy, respectively. Pairwise t-test was used to evaluate the statistically significant difference.Results: The accuracy of the AI system in malignancy diagnosis was 0.71, which was higher than the best radiologist in this study by a margin of 0.09 with a p-value of 2.08×10-5. Two radiologists had higher sensitivity (0.84 and 0.78) than that of the AI system (0.69) at the cost of having much lower specificity (0.35, 0.57 versus 0.71). One senior radiologist showed balanced sensitivity and specificity (0.62 and 0.54) but both were lower than that of the AI system.Conclusions: The generally trained AI automatic diagnosis system can potentially assist radiologists for distinguishing FTC from other FPTL cases that share poorly distinguishable ultrasonographical features.
- 31 October 2022
- Published by Frontiers Media SA in Frontiers in Endocrinology
- Vol. 13, 981403
Open AccessAn artificial intelligence ultrasound system’s ability to distinguish benign from malignant follicular-patterned lesions
Objectives: To evaluate the application value of a generally trained artificial intelligence (AI) automatic diagnosis system in the malignancy diagnosis of follicular-patterned thyroid lesions (FPTL), including follicular thyroid carcinoma (FTC), adenomatoid hyperplasia nodule (AHN) and follicular thyroid adenoma (FTA) and compare the diagnostic performance with radiologists of different experience levels.Methods: We retrospectively reviewed 607 patients with 699 thyroid nodules that included 168 malignant nodules by using postoperative pathology as the gold standard, and compared the diagnostic performances of three radiologists (one junior, two senior) and that of AI automatic diagnosis system in malignancy diagnosis of FPTL in terms of sensitivity, specificity and accuracy, respectively. Pairwise t-test was used to evaluate the statistically significant difference.Results: The accuracy of the AI system in malignancy diagnosis was 0.71, which was higher than the best radiologist in this study by a margin of 0.09 with a p-value of 2.08×10-5. Two radiologists had higher sensitivity (0.84 and 0.78) than that of the AI system (0.69) at the cost of having much lower specificity (0.35, 0.57 versus 0.71). One senior radiologist showed balanced sensitivity and specificity (0.62 and 0.54) but both were lower than that of the AI system.Conclusions: The generally trained AI automatic diagnosis system can potentially assist radiologists for distinguishing FTC from other FPTL cases that share poorly distinguishable ultrasonographical features.
- 20 April 2022
- Published by Elsevier in Engineering Analysis with Boundary Elements
- Vol. 140, 159-166
The local meshless method based on Pascal polynomial basis functions for solving fourth-order PDEs
- 20 April 2022
- Published by Elsevier in Engineering Analysis with Boundary Elements
- Vol. 140, 159-166
The local meshless method based on Pascal polynomial basis functions for solving fourth-order PDEs
- Open Access
Techniques and Algorithms for Hepatic Vessel Skeletonization in Medical Images: A Survey
Hepatic vessel skeletonization serves as an important means of hepatic vascular analysis and vessel segmentation. This paper presents a survey of techniques and algorithms for hepatic vessel skeletonization in medical images. We summarized the latest developments and classical approaches in this field. These methods are classified into five categories according to their methodological characteristics. The overview and brief assessment of each category are provided in the corresponding chapters, respectively. We provide a comprehensive summary among the cited publications, image modalities and datasets from various aspects, which hope to reveal the pros and cons of every method, summarize its achievements and discuss the challenges and future trends.
Open AccessTechniques and Algorithms for Hepatic Vessel Skeletonization in Medical Images: A Survey
Hepatic vessel skeletonization serves as an important means of hepatic vascular analysis and vessel segmentation. This paper presents a survey of techniques and algorithms for hepatic vessel skeletonization in medical images. We summarized the latest developments and classical approaches in this field. These methods are classified into five categories according to their methodological characteristics. The overview and brief assessment of each category are provided in the corresponding chapters, respectively. We provide a comprehensive summary among the cited publications, image modalities and datasets from various aspects, which hope to reveal the pros and cons of every method, summarize its achievements and discuss the challenges and future trends.
- 29 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Pixel-RRT*: A Novel Skeleton Trajectory Search Algorithm for Hepatic Vessels
In the clinical treatment of liver disease such as tumor, the acquisition of vascular skeleton trajectory is of great worth to untangle the basin and venation of hepatic vessels, because tumor and vessels are closely intertwined. In most cases, skeletonization based on the results of vascular segmentation will be prone to fracture due to the discontinuous segmenting results of vessels. As the overall tree-like system of hepatic vessels is a thin tubular tissue, we expect to start the analysis of vessels from vascular skeleton to vascular boundary, not the contrary, which can more effectively implement the image computing of hepatic vessels and interpret the tree-like expansion. To this issue, in this paper, we propose an innovative approach Pixel-RRT* inspired by Marray's Law and the growing rule of biological vasculature. It can be applied to the skeleton trajectory search for the intricate hepatic vessels. In Pixel-RRT*, we introduce the novel pixel-based cost function, the design of pixel-distributed random sampling, and a multi-goal strategy in the shared graph of random tree based on the general algorithmic framework of RRT* and RRT. Without any prior segmentation of the vessels, the proposed Pixel-RRT* can rapidly return the rationally bifurcated vascular trajectories satisfying the principle of minimal energy and topological continuity. In addition, we put forward an adaptively interpolated variational method as the postprocessing technique to make the vascular trajectory smoother by the means of energy minimization. The simulation experiments and examples of hepatic vessels demonstrate our method is efficient and utilisable. The codes will be made available at https://github.com/JeffJFZ/Pixel-RRTStar.
- 29 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Pixel-RRT*: A Novel Skeleton Trajectory Search Algorithm for Hepatic Vessels
In the clinical treatment of liver disease such as tumor, the acquisition of vascular skeleton trajectory is of great worth to untangle the basin and venation of hepatic vessels, because tumor and vessels are closely intertwined. In most cases, skeletonization based on the results of vascular segmentation will be prone to fracture due to the discontinuous segmenting results of vessels. As the overall tree-like system of hepatic vessels is a thin tubular tissue, we expect to start the analysis of vessels from vascular skeleton to vascular boundary, not the contrary, which can more effectively implement the image computing of hepatic vessels and interpret the tree-like expansion. To this issue, in this paper, we propose an innovative approach Pixel-RRT* inspired by Marray's Law and the growing rule of biological vasculature. It can be applied to the skeleton trajectory search for the intricate hepatic vessels. In Pixel-RRT*, we introduce the novel pixel-based cost function, the design of pixel-distributed random sampling, and a multi-goal strategy in the shared graph of random tree based on the general algorithmic framework of RRT* and RRT. Without any prior segmentation of the vessels, the proposed Pixel-RRT* can rapidly return the rationally bifurcated vascular trajectories satisfying the principle of minimal energy and topological continuity. In addition, we put forward an adaptively interpolated variational method as the postprocessing technique to make the vascular trajectory smoother by the means of energy minimization. The simulation experiments and examples of hepatic vessels demonstrate our method is efficient and utilisable. The codes will be made available at https://github.com/JeffJFZ/Pixel-RRTStar.
- 1 November 2020
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 177, 487-499
Localized meshless methods based on polynomial basis functions for solving axisymmetric equations
- 1 November 2020
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 177, 487-499
Localized meshless methods based on polynomial basis functions for solving axisymmetric equations
- 1 December 2018
- Published by Elsevier in Applied Mathematics Letters
- Vol. 86, 179-185
Solving fourth order differential equations using particular solutions of Helmholtz-type equations
- 1 December 2018
- Published by Elsevier in Applied Mathematics Letters
- Vol. 86, 179-185
Solving fourth order differential equations using particular solutions of Helmholtz-type equations