MSMarcos Antonio Salvino da Silva

Marcos Antonio Salvino da Silva

*This is an algorithmically generated author record based on publicly available information.

Marcos Antonio Salvino da Silva has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Eficiência Microbiológica de Sistemas de Filtração HEPA na Prevenção de Bioaerossóis Multirresistentes em Ambientes Hospitalares

    by Ricardo Andrade Santos, Marcos Antonio Salvino da Silva, Fernanda Roberta Marciano, Marcelo Rodrigues Pereira, Alejandro Marcel Hasslocher-Moreno

    A climatização em Centros de Terapia Intensiva (CTI) e enfermarias representa um importante vetor para a disseminação de microrganismos transmitidos por bioaerossóis, expondo pacientes e profissionais de saúde a riscos adicionais. Este estudo avaliou a eficiência microbiológica de sistemas de climatização com filtragem HEPA em um hospital, visando prevenir a propagação de doenças respiratórias de transmissão aérea. Amostras de ar foram coletadas, por impactação ativa, durante 32 semanas em CTIs e enfermarias. Os resultados mostraram uma predominância de fungos (67%) e bactérias (33%), com contagens de unidades formadoras de colônias acima dos limites estabelecidos pelas normas vigentes. As análises indicaram falhas nos sistemas de ventilação, como ausência de pressão negativa e manutenção inadequada, comprometendo a eficácia da filtração. Conclui-se que a revisão e atualização das normas de projeto e operação dos sistemas de climatização hospitalar são essenciais para aprimorar a segurança microbiológica dos ambientes assistenciais.

  • Open Access

    A bioimpedance spectroscopy technique to monitor bioprocess involving complex growth micro-organisms

    by Marcos Antonio Salvino da Silva, Elizabeth Gomes Sanches, Nei Pereira, Marcio Nogueira de Souza, Alexandre Visintainer Pino

    Although analytical methods (often offline) are considered as references (gold standards) for monitoring industrial bioprocesses, real-time monitoring (online) is always preferable for maximizing such processes. However, many of the real-time methods that measure total cell concentration cannot distinguish living micro-organisms from the dead ones or even other materials. Moreover, some real-time methods also lead to possible wrong results when the micro-organism involved in the bioprocess exhibits significant metabolic, physiological, and kinetic changes as it grows. This study presents a real-time technique intended to monitor this class of micro-organisms and that is based on an alternative method of bioimpedance spectroscopy. The feasibility of the proposed technique was evaluated during bacterial growth experiments using the bacteria Bacillus thuringiensis var. israelensis (Bti) with initial inocula of 5%, 10%, and 15% (v/v on 220 ml). Each growth experiment was monitored every hour over 18 h by the proposed technique and by a classical offline method (McFarland method). The results of monitoring the studied bioprocess by both methods exhibited an average Pearson correlation coefficient (r̄ ) of above 0.9 and good agreement when the Bland–Altman method was used to compare them.


  • Real-Time Monitoring of Yeasts Growth Based on Bioimpedance Spectroscopy

    by Marcos Antonio Salvino da Silva, Elizabeth Gomes Sanches, Alexandre Visintainer Pino, Marcio Nogueira de Souza