MCMiriam Chinzon

Miriam Chinzon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Miriam Chinzon has a total of 52 co-authors. Here are the top co-authors by number of shared publications:

  • Eduardo Guimarães Hourneaux de Moura

    Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil

    3 shared publications
  • Eduardo Guimarães Hourneaux de Moura

    Gastrointestinal Endoscopy Unit, Division of Gastroenterology Hospital das Clínicas of the Faculty of Medicine of the University of São Paulo – HC/FMUSP São Paulo Brazil

    2 shared publications
  • Larissa Mercadante de Assis

    Gastrointestinal Endoscopy Unit, Department of Gastroenterology, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo 05403-000, Brazil

    2 shared publications
  • Luiza Bicudo de Oliveira

    Gastrointestinal Endoscopy Unit, Division of Gastroenterology, Hospital das Clínicas of the Faculty of Medicine of the University of São Paulo - HC/FMUSP, Sao Paulo, Brazil

    2 shared publications
  • Vitor Hernandes Lopes

    Gastrointestinal Endoscopy Unit, Division of Gastroenterology Hospital das Clínicas of the Faculty of Medicine of the University of São Paulo – HC/FMUSP São Paulo Brazil

    2 shared publications
  • Wanderley Marques Bernardo

    Gastrointestinal Endoscopy Unit, Division of Gastroenterology Hospital das Clínicas of the Faculty of Medicine of the University of São Paulo – HC/FMUSP São Paulo Brazil

    2 shared publications

Latest Publications

  • Open Access

    Artificial Intelligence and Endobronchial Ultrasound for Lymph-Node Detection and Characterization: A Pioneer Multicenter Transatlantic Study

    by Miguel Mascarenhas, Gema Diaz Nuevo, Sara Lopes, Juan Puertas Sancho, Cristina Lopez Garcia-Gallo, Luiza Bicudo de Oliveira, Miriam Chinzon, Larissa Mercadante de Assis, Gustavo Ejima, Fauze Maluf-Filho, et al.

    Background/Objectives: Accurate mediastinal and hilar lymph node (LN) assessment is central to lung cancer staging and treatment selection. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has become the standard minimally invasive procedure for mediastinal staging, enabling real-time identification, characterization and sampling of LNs. Although effective, this technique remains operator dependent, and subject to interobserver variability. This study aims to report the development of a Vision Transformer-based AI model for automatic LN detection and classification on EBUS images. Methods: A multicenter, multidevice, retrospective study, using EBUS images of three referral centers (Spain and Brazil). The dataset included images of patients with benign and malignant LNs. Bounding-box annotations were applied for LN localization, and LNs were classified as benign or malignant according to histopathologic reference standards. Detection performance was evaluated with mean average precision, at an intersection over union threshold of 0.5 (mAP50). Characterization performance was assessed using accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC). Results: The dataset included 6492 images from 27 patients, of whom 16 had malignant LNs. In the test set, the model achieved a mAP50 of 0.79 for LN detection. For malignant characterization, the model achieved an accuracy of 90.6%, sensitivity of 85.4%, and an AUROC of 0.938. Conclusions: The results of this study support the feasibility of AI-assisted EBUS interpretation for nodal staging workflows and raise the possibility that AI-assisted EBUS could enhance diagnostic performance, while reducing operator variability. Larger prospective studies are needed before clinical implementation.

  • Open Access

    Suction-assisted Tissue Acquisition by Cholangioscopy: A Novel Technique to Improve Diagnosis of Indeterminate Biliary Strictures

    by Tomazo Antonio Prince Franzini, Marcelo Klotz Dall'AGnol, André Orsini Ardengh, Miriam Chinzon, Luiza Bicudo de Oliveira, Pedro Henrique Veras Ayres da Silva, Danielle Azevedo Chacon, Fauze Maluf-Filho

  • Efficacy and Safety of Double Guidewire Versus Transpancreatic Sphincterotomy in Difficult Biliary Cannulation: A Systematic Review and Meta‐Analysis of Randomized Clinical Trials

    by Larissa Mercadante de Assis, Mateus Pereira Funari, Luiza Bicudo de Oliveira, Benjamin Ian Richter, Miriam Chinzon, Vitor Hernandes Lopes, Matheus Oliveira Veras, Marcos Eduardo Lera dos Santos, Gustavo Oliveira Luz, Wanderley Marques Bernardo, et al.

    Background: Difficult biliary cannulation is a key challenge in endoscopic retrograde cholangiopancreatography and a major risk factor for post‐ ERCP pancreatitis. When the pancreatic duct is unintentionally accessed, double guidewire ( DGW ) is the primary rescue strategy, while transpancreatic sphincterotomy ( TPS ) is an alternative. Previous evidence suggests that TPS may achieve higher cannulation success and lower PEP rates compared to DGW , though direct comparative data remain limited. This review and meta‐analysis assess the clinical outcomes of TPS and DGW in the setting of difficult biliary cannulation. Methods: This review involved searching Medline, Embase, Lilacs, Central Cochrane, and Google Scholar. Outcomes assessed included PEP , successful biliary cannulation, mean cannulation time, and other adverse events (bleeding, cholangitis, perforation). Results: A total of 463 patients from five randomized controlled trials were included. The DGW group showed a higher risk of PEP pancreatitis and other adverse events ( p = 0.009; RR = 1.81 [1.16, 2.83]; I 2 = 34%) and ( p = 0.03; RR = 2.20 [1.10, 4.39]; I 2 = 0%), respectively. A significant difference favoring TPS was found for successful cannulation and mild pancreatitis ( p = 0.001; RR = 1.79 [1.26, 2.54]; I 2 = 40%) and ( p = 0.01; RR = 2.26 [1.20, 4.28]; I 2 = 35%), respectively. No significant difference was observed for mean cannulation time or moderate to severe PEP ( p = 0.18; SMD = −0.37 [−0.91, 0.17]; I 2 = 79%) and ( p = 0.32; RR = 1.50 [0.67, 3.36]; I 2 = 0%), respectively. A restricted analysis excluding two studies affected by external factors inflating the pancreatitis rate did not reveal a significant difference ( p = 0.61; RR = 1.16 [0.66, 2.04]; I 2 = 0%). Conclusion: Prior studies comparing TPS and DGW yield different results. This may occur because there are technical variables that are difficult to control. Overall, TPS demonstrated superior cannulation success, may have lower PEP rates, and fewer other complications, although more homogeneous studies are needed to validate these findings.


  • Precut mucosectomy versus endoscopic resection techniques for colorectal lesions sized 10–30 mm: meta-analysis and systematic review

    by Miriam Chinzon, Mateus Bond Boghossian, Matheus de Oliveira Veras, Evellin Souza Valentim dos Santos, Daryl Ramai, Larissa Mercadante de Assis, Vitor Hernandes Lopes, Nelson Miyajima, Wanderley Marques Bernardo, Eduardo Guimarães Hourneaux de Moura

    Background Early-stage colorectal lesions are traditionally managed with conventional endoscopic mucosal resection (EMR-C). Endoscopic submucosal dissection (ESD), though technically demanding, enables en bloc resection with negative margins. Precut mucosectomy (EMR-P) was developed to enhance en bloc resection rates by minimizing the risk of snare slippage during procedures. Methods A systematic review and meta-analysis of cohort studies and randomized controlled trials (RCTs) compared EMR-P with EMR-C, ESD, and Hybrid ESD (ESD-H). Databases were queried for studies reporting en bloc resection rate and complete histological resection rate (R0), as well outcomes including procedure time, recurrence rate, and adverse events. Risk ratios (RRs) and weighted mean differences with 95% confidence intervals (CIs) were calculated using random or fixed-effects models based on heterogeneity. Results Twelve studies, including 2.575 lesions (921 EMR-P, 615 EMR-C, 955 ESD, 84 ESD-H), were analyzed. EMR-P outperformed EMR-C in en bloc resection rates (RR 1.17, 95% CI: 1.03–1.33; P = 0.01) and R0 resection rates (RR 1.34, 95% CI: 1.15–1.57; P = 0.0002), particularly for flat lesions in the right colon. However, EMR-P was associated with a higher rate of adverse events. Compared to ESD, EMR-P demonstrated lower en bloc resection rate (RR 0.85; 95% CI; 0.75–0.97, P = 0.02) but showed no significant difference R0 resection rate (RR 0.95, 95% CI, 0.88–1.02, P = 0.15). In head-to-head comparisons between EMR-P and ESD-H, no significant differences were observed in en bloc or complete resection rates. Conclusion EMR-P emerges as a promising technique for resecting flat colorectal lesions > 10 mm, particularly those in the right colon, by reducing the risk of snare slippage. Future RCTs are essential to establish EMR-P’s role in managing large colorectal neoplasms and optimizing recurrence prevention strategies.


  • Open Access

    Extensive Esophageal Papillomatosis: A Rare Disease With Difficult Diagnosis

    by Miriam Chinzon, Sergio Barbosa Marques, Eduardo Guimarães Hourneaux de Moura

    Extensive esophageal papillomatosis is a rare condition with uncertain pathophysiology. We present a case involving a 78-year-old woman, with no notable habits or addictions, who presented with dysphagia and weight loss. She was diagnosed with extensive esophageal papillomatosis, causing esophageal substenosis. Diagnosis of dysplasia in such cases are challenging, and management of the risk of malignant transformation remains uncertain.


  • Open Access

    Endoscopic stricturotomy for axis-related gastric outlet obstruction following sleeve gastrectomy

    by Luana Gabriela dos Santos, Miriam Chinzon, Alexandre Moraes Bestetti, Diogo Turiani Hourneaux de Moura, Eduardo Guimarães Hourneaux de Moura

    Axis deviation and helical stricture following sleeve gastrectomy may result in functional gastric outlet obstruction, leading to significant patient morbidity. Conventional endoscopic therapies, such as balloon dilation and self-expandable metal stents (SEMS), have demonstrated limited efficacy and are frequently associated with recurrence and complications. This study aimed to assess clinical outcomes of endoscopic stricturotomy as a minimally invasive technique for managing axis-related stenosis after sleeve gastrectomy. This retrospective case series included adult patients (≥ 18 years) who underwent endoscopic stricturotomy for axis-related stenosis at a tertiary academic center from 2019 to 2024. Diagnosis of helical stricture was confirmed via endoscopic and radiologic assessments. Clinical data were obtained through electronic chart review and structured telephone interviews. Symptom severity was evaluated using the Gastroparesis Cardinal Symptom Index (GCSI), and quality of life was assessed using a visual analog scale (VAS). Statistical analysis included the Shapiro-Wilk test and paired t-test or Wilcoxon signed-rank test, with P < 0.05 considered significant. Eight patients (mean age 53 years; 62.5% female) were included, with a mean time of 31.3 months between surgery and stricturotomy. All GCSI domains showed significant symptom improvement. The global GCSI score improved from 35.44 to 21.66 (P = 0.014), and VAS scores increased from 3.0 to 7.75. Complications included two cases of intraoperative pneumoperitoneum and one delayed gastric fistula, all managed non-surgically. Endoscopic stricturotomy is a promising, minimally invasive treatment for axis-related gastric outlet obstruction post-sleeve gastrectomy. Prospective studies are warranted to confirm long-term outcomes.

  • Open Access

    CONSTIPATION. AN OLD NEW PROBLEM

    by Decio Chinzon, Miriam Chinzon