Si-Doek Oh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Si-Doek Oh has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ho-Young Kwak
Mechanical Engineering Department, Chung-Ang University, Seoul, Korea
8 shared publications - Seok-Ho Seo
Blue Economy Strategy Institute Co., Ltd., 150 Dogok-ro, Gangnam-gu, Seoul 06260, Republic of Korea
7 shared publications - Yungpil Yoo
Department of Climate Change Energy Engineering, Yonsei University, Seoul 03722, Republic of Korea
5 shared publications - Sang Yup Lee
Metabolic and Biomolecular Engineering National Research Laboratory, Department of Chemical and Biomolecular Engineering (BK21 Four Program), Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
3 shared publications - Chul-Yong Lee
School of Business, Pusan National University, 2, Busan Daehak-ro 63beon-gil, Geumjeong-gu, Busan 46241, Republic of Korea
1 shared publication - Junhyun Cho
Energy Conversion Laboratory, Korea Institute of Energy Research (KIER), Daejeon, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 12 November 2026
- Published by MDPI AG in Preprints.org
Allocation of Carbon Dioxide Emissions in Cogeneration Plants: An Exergy and Exergoeconomic Approach
The allocation of carbon dioxide (CO2) emissions is a critical issue in emissions trading schemes and greenhouse gas (GHG) assessment methodologies. Various modified methods based on energy and exergy approaches have been proposed to allocate CO2 emissions in combined heat and power (CHP) plants; however, a universally accepted approach has not yet been established. While the exergy-based approach has been regarded as the fairest method for CO2 allocation to date, it has not yet been analytically proven. In this study, the Modified Productive Structure Analysis (MOPSA) method, an exergoeconomic analysis, was employed to calculate the incremental cost flow rates for electricity and steam resulting from the imposition of a cost on CO2 emissions from the plant combustor. For CHP plants operating at two heat-to-power ratios (HPRs), CO2 emissions were allocated between heat and electricity in proportion to the increase in their respective cost flow rates. The results indicate that the cost-based method utilizing MOPSA and the CO2 emission allocation method based on exergoeconomic analysis yield allocations similar to those of the exergy-based method for the low-HPR case. However, for the high-HPR case, both methods allocate a slightly larger share of CO2 emissions to electricity than does the exergy-based method.
- 12 November 2026
- Published by MDPI AG in Preprints.org
Open AccessAllocation of Carbon Dioxide Emissions in Cogeneration Plants: An Exergy and Exergoeconomic Approach
The allocation of carbon dioxide (CO2) emissions is a critical issue in emissions trading schemes and greenhouse gas (GHG) assessment methodologies. Various modified methods based on energy and exergy approaches have been proposed to allocate CO2 emissions in combined heat and power (CHP) plants; however, a universally accepted approach has not yet been established. While the exergy-based approach has been regarded as the fairest method for CO2 allocation to date, it has not yet been analytically proven. In this study, the Modified Productive Structure Analysis (MOPSA) method, an exergoeconomic analysis, was employed to calculate the incremental cost flow rates for electricity and steam resulting from the imposition of a cost on CO2 emissions from the plant combustor. For CHP plants operating at two heat-to-power ratios (HPRs), CO2 emissions were allocated between heat and electricity in proportion to the increase in their respective cost flow rates. The results indicate that the cost-based method utilizing MOPSA and the CO2 emission allocation method based on exergoeconomic analysis yield allocations similar to those of the exergy-based method for the low-HPR case. However, for the high-HPR case, both methods allocate a slightly larger share of CO2 emissions to electricity than does the exergy-based method.
- Open Access
Exergoeconomic Analysis of Power Plants: Impact of Exergy Destruction Due to Entropy Generation on Unit Cost of Electricity
Various exergy-based exergoeconomic methods have been developed to evaluate the production cost of electricity in power systems. One of the unresolved issues in the field of exergoeconomics is that different exergoeconomic analysis methods can yield different unit costs of power production. In this study, the unit cost of electricity generation is comprehensively analyzed using three representative approaches: the Moran method, the specific exergy costing (SPECO) method, and the Modified Productive Structure Analysis (MOPSA) method. The objective of this study is to identify a condition under which different exergoeconomic methods yield the same production cost for a power plant. The results show that power production costs are obtained using all three exergoeconomic methods when the costs associated with exergy destruction are appropriately incorporated in the cost-balance equation. In other words, under this condition, the cost-balance equations of SPECO and MOPSA for the entire power plant reduce to the Moran equation. These findings indicate that the critical issue in exergoeconomic analysis for determining the unit cost of products is whether the cost of exergy destruction is explicitly or implicitly accounted for. Furthermore, the numerical results demonstrate that all input cost rates, including equipment investment, operation and maintenance, and fuel costs, are fully recovered through the cost flow rates of the products. It is also shown that the cost flow associated with exergy destruction ultimately appears as the cost flow of waste streams.
Open AccessExergoeconomic Analysis of Power Plants: Impact of Exergy Destruction Due to Entropy Generation on Unit Cost of Electricity
Various exergy-based exergoeconomic methods have been developed to evaluate the production cost of electricity in power systems. One of the unresolved issues in the field of exergoeconomics is that different exergoeconomic analysis methods can yield different unit costs of power production. In this study, the unit cost of electricity generation is comprehensively analyzed using three representative approaches: the Moran method, the specific exergy costing (SPECO) method, and the Modified Productive Structure Analysis (MOPSA) method. The objective of this study is to identify a condition under which different exergoeconomic methods yield the same production cost for a power plant. The results show that power production costs are obtained using all three exergoeconomic methods when the costs associated with exergy destruction are appropriately incorporated in the cost-balance equation. In other words, under this condition, the cost-balance equations of SPECO and MOPSA for the entire power plant reduce to the Moran equation. These findings indicate that the critical issue in exergoeconomic analysis for determining the unit cost of products is whether the cost of exergy destruction is explicitly or implicitly accounted for. Furthermore, the numerical results demonstrate that all input cost rates, including equipment investment, operation and maintenance, and fuel costs, are fully recovered through the cost flow rates of the products. It is also shown that the cost flow associated with exergy destruction ultimately appears as the cost flow of waste streams.
- Open Access
- 30 July 2026
- Published by MDPI AG in Preprints.org
Thermoeconomic Analysis of Power Plants: Impact of Exergy Destruction due to Entropy Generation on Unit Cost of Electricity
Various exergy-based thermoeconomic methods have been developed to evaluate the production cost of electricity in power systems. One of the currently unresolved problems in the field of thermoeconomics is that different thermoeconomic analysis methods yield different unit power production costs. In this study, the unit cost of electricity generation is comprehensively analyzed using three representative approaches: the Moran method, the Specific Exergy Costing (SPECO) method, and the Modified Productive Structure Analysis (MOPSA) method. According to the results, similar power production costs are obtained across all thermoeconomic methods when the costs associated with exergy destruction are appropriately reflected in the cost-balance equation. In other words, in this case, the cost-balance equation for the entire power plant of SPECO and MOPSA becomes the Moran equation. These findings indicate that the critical issue in thermoeconomic analysis to obtain the unit cost of products is whether the cost of exergy destruction is explicitly or implicitly accounted for. Furthermore, the study numerically demonstrates that all input cost rates, including equipment investment, operation and maintenance, and fuel costs, are fully recovered through the cost flow rates of the products. It is also shown that the cost flow associated with exergy destruction ultimately appears as the cost flow of waste streams.
- 30 July 2026
- Published by MDPI AG in Preprints.org
Open AccessThermoeconomic Analysis of Power Plants: Impact of Exergy Destruction due to Entropy Generation on Unit Cost of Electricity
Various exergy-based thermoeconomic methods have been developed to evaluate the production cost of electricity in power systems. One of the currently unresolved problems in the field of thermoeconomics is that different thermoeconomic analysis methods yield different unit power production costs. In this study, the unit cost of electricity generation is comprehensively analyzed using three representative approaches: the Moran method, the Specific Exergy Costing (SPECO) method, and the Modified Productive Structure Analysis (MOPSA) method. According to the results, similar power production costs are obtained across all thermoeconomic methods when the costs associated with exergy destruction are appropriately reflected in the cost-balance equation. In other words, in this case, the cost-balance equation for the entire power plant of SPECO and MOPSA becomes the Moran equation. These findings indicate that the critical issue in thermoeconomic analysis to obtain the unit cost of products is whether the cost of exergy destruction is explicitly or implicitly accounted for. Furthermore, the study numerically demonstrates that all input cost rates, including equipment investment, operation and maintenance, and fuel costs, are fully recovered through the cost flow rates of the products. It is also shown that the cost flow associated with exergy destruction ultimately appears as the cost flow of waste streams.
- Open Access
Energy, Exergetic, and Thermoeconomic Analyses of Hydrogen-Fueled 1-kW Proton-Exchange Membrane Fuel Cell
Exergy analysis evaluates the efficiency of system components by quantifying the rate of entropy generation. In general, the exergy destruction rate or irreversibility rate was directly obtained through the exergy balance equation. However, this method cannot determine the origin of the component’s entropy generation rate, which is a very important factor in system design and improvement. In this study, a thorough energy, exergy, and thermoeconomic analysis of a proton-exchange membrane fuel cell (PEMFC) was performed, providing the heat transfer rate, entropy generation rate, and cost loss rate of each component. The irreversibility rate of each component was obtained by the Gouy–Stodola theorem. Detailed and extensive exergy and thermoeconomic analyses of the PEMFC system determined that water cooling units experience the greatest heat transfer among the components in the studied PEMFC system, resulting in the greatest irreversibility and, thus, the greatest monetary flow loss.
Open AccessEnergy, Exergetic, and Thermoeconomic Analyses of Hydrogen-Fueled 1-kW Proton-Exchange Membrane Fuel Cell
Exergy analysis evaluates the efficiency of system components by quantifying the rate of entropy generation. In general, the exergy destruction rate or irreversibility rate was directly obtained through the exergy balance equation. However, this method cannot determine the origin of the component’s entropy generation rate, which is a very important factor in system design and improvement. In this study, a thorough energy, exergy, and thermoeconomic analysis of a proton-exchange membrane fuel cell (PEMFC) was performed, providing the heat transfer rate, entropy generation rate, and cost loss rate of each component. The irreversibility rate of each component was obtained by the Gouy–Stodola theorem. Detailed and extensive exergy and thermoeconomic analyses of the PEMFC system determined that water cooling units experience the greatest heat transfer among the components in the studied PEMFC system, resulting in the greatest irreversibility and, thus, the greatest monetary flow loss.
- Open Access
- 16 May 2024
- Published by MDPI AG in Preprints.org
Energy, Exergetic and Thermoeconomic Analyses of Hydrogen-Fueled 1-kW Proton Exchange Membrane Fuel Cell
Exergy analysis evaluates the efficiency of system components by quantifying the rate of entropy generation. In general, the exergy destruction rate or irreversibility rate was directly obtained through the exergy-balance equation. However, this method cannot determine the origin of the component's entropy generation rate, which is a very important factor in system design and improvement. In this study, a thorough energy, exergy thermoeconomic analysis of a proton exchange membrane fuel cell (PEMFC) was performed, providing the heat transfer rate, entropy generation rate and cost loss rate of each component. The irreversibility rate of each component is obtained by the Gouy-Stodolar theorem. Detailed and extensive exergy and thermoeconomic analyses of PEMFC system have determined that water cooling units experience the greatest heat transfer among the components in the studied PEMFC system, resulting in the greatest irreversibility and thus the greatest monetary flow loss.
- 16 May 2024
- Published by MDPI AG in Preprints.org
Open AccessEnergy, Exergetic and Thermoeconomic Analyses of Hydrogen-Fueled 1-kW Proton Exchange Membrane Fuel Cell
Exergy analysis evaluates the efficiency of system components by quantifying the rate of entropy generation. In general, the exergy destruction rate or irreversibility rate was directly obtained through the exergy-balance equation. However, this method cannot determine the origin of the component's entropy generation rate, which is a very important factor in system design and improvement. In this study, a thorough energy, exergy thermoeconomic analysis of a proton exchange membrane fuel cell (PEMFC) was performed, providing the heat transfer rate, entropy generation rate and cost loss rate of each component. The irreversibility rate of each component is obtained by the Gouy-Stodolar theorem. Detailed and extensive exergy and thermoeconomic analyses of PEMFC system have determined that water cooling units experience the greatest heat transfer among the components in the studied PEMFC system, resulting in the greatest irreversibility and thus the greatest monetary flow loss.
- 30 April 2024
- Published by The Korean Society of Climate Change Research in Journal of Climate Change Research
- Vol. 15 (2) , 261-270
Economic feasibility analysis of a Jeju onshore wind power project using a stochastic methodology
Jeju Island introduced the CFI 2030 (Carbon Free Island 2030) policy in 2013, actively promoting the expansion of renewable energy such as solar and wind power. The primary objective is to achieve energy independence by establishing a clean energy system. This study analyzes the economic feasibility of the Jeju onshore wind farm expansion project, which is being promoted as part of CFI 2030 policy, from a national economic perspective. Utilizing the deterministic analysis method, we calculated B/C, NPV, and IRR values to assess the economic feasibility of the project. Simultaneously, we examined the sensitivity of key factors influencing economic feasibility, including discount rates, benefits, and costs. Recognizing the inherent uncertainties associated with renewable energy projects, we performed a stochastic analysis through the application of Monte Carlo simulation, obtaining essential information for informed project implementation decisions. Deterministic analysis confirmed that the proposed project was economically feasible. Sensitivity analysis indicates that economic feasibility can be maintained unless costs increase by more than 10.55% or SMP values decrease by more than 9.15%. Stochastic analysis results using Monte Carlo simulation revealed slightly lower values compared to deterministic analysis; however, the ranges and trends were similar. The methodology and results of this study can be used for policy decisions and to conduct further research on implementation of the project.
- 30 April 2024
- Published by The Korean Society of Climate Change Research in Journal of Climate Change Research
- Vol. 15 (2) , 261-270
Economic feasibility analysis of a Jeju onshore wind power project using a stochastic methodology
Jeju Island introduced the CFI 2030 (Carbon Free Island 2030) policy in 2013, actively promoting the expansion of renewable energy such as solar and wind power. The primary objective is to achieve energy independence by establishing a clean energy system. This study analyzes the economic feasibility of the Jeju onshore wind farm expansion project, which is being promoted as part of CFI 2030 policy, from a national economic perspective. Utilizing the deterministic analysis method, we calculated B/C, NPV, and IRR values to assess the economic feasibility of the project. Simultaneously, we examined the sensitivity of key factors influencing economic feasibility, including discount rates, benefits, and costs. Recognizing the inherent uncertainties associated with renewable energy projects, we performed a stochastic analysis through the application of Monte Carlo simulation, obtaining essential information for informed project implementation decisions. Deterministic analysis confirmed that the proposed project was economically feasible. Sensitivity analysis indicates that economic feasibility can be maintained unless costs increase by more than 10.55% or SMP values decrease by more than 9.15%. Stochastic analysis results using Monte Carlo simulation revealed slightly lower values compared to deterministic analysis; however, the ranges and trends were similar. The methodology and results of this study can be used for policy decisions and to conduct further research on implementation of the project.
- Open Access
Energy, Exergy and Thermoeconomic Analyses on Hydrogen Production Systems Using High-Temperature Gas-Cooled and Water-Cooled Nuclear Reactors
The use of nuclear energy is inevitable to reduce the dependence on fossil fuels in the energy sector. High-temperature gas-cooled reactors (HTGRs) are considered as a system suitable for the purpose of reducing the use of fossil fuels. Furthermore, eco-friendly mass production of hydrogen is crucial because hydrogen is emerging as a next-generation energy carrier. The unit cost of hydrogen production by the levelized cost of energy (LCOE) method varies widely depending on the energy source and system configuration. In this study, energy, exergy, and thermoeconomic analyses were performed on the hydrogen production system using the HTGR and high-temperature water-cooled nuclear reactor (HTWR) to calculate reasonable unit cost of the hydrogen produced using a thermoeconomic method called modified production structure analysis (MOPSA). A flowsheet analysis was performed to confirm the energy conservation in each component. The electricity generated from the 600 MW HTGR system was used to produce 1.28 kmol/s of hydrogen by electrolysis to split hot water vapor. Meanwhile, 515 MW of heat from the 600 MW HTWR was used to produce 8.10 kmol/s of hydrogen through steam reforming, and 83.6 MW of electricity produced by the steam turbine was used for grid power. The estimated unit cost of hydrogen from HTGR is approximately USD 35.6/GJ with an initial investment cost of USD 2.6 billion. If the unit cost of natural gas is USD 10/GJ, and the carbon tax is USD 0.08/kg of carbon dioxide, the unit cost of hydrogen produced from HTWR is approximately USD 13.92/GJ with initial investment of USD 2.32 billion. The unit cost of the hydrogen produced in the scaled-down plant was also considered.
Open AccessEnergy, Exergy and Thermoeconomic Analyses on Hydrogen Production Systems Using High-Temperature Gas-Cooled and Water-Cooled Nuclear Reactors
The use of nuclear energy is inevitable to reduce the dependence on fossil fuels in the energy sector. High-temperature gas-cooled reactors (HTGRs) are considered as a system suitable for the purpose of reducing the use of fossil fuels. Furthermore, eco-friendly mass production of hydrogen is crucial because hydrogen is emerging as a next-generation energy carrier. The unit cost of hydrogen production by the levelized cost of energy (LCOE) method varies widely depending on the energy source and system configuration. In this study, energy, exergy, and thermoeconomic analyses were performed on the hydrogen production system using the HTGR and high-temperature water-cooled nuclear reactor (HTWR) to calculate reasonable unit cost of the hydrogen produced using a thermoeconomic method called modified production structure analysis (MOPSA). A flowsheet analysis was performed to confirm the energy conservation in each component. The electricity generated from the 600 MW HTGR system was used to produce 1.28 kmol/s of hydrogen by electrolysis to split hot water vapor. Meanwhile, 515 MW of heat from the 600 MW HTWR was used to produce 8.10 kmol/s of hydrogen through steam reforming, and 83.6 MW of electricity produced by the steam turbine was used for grid power. The estimated unit cost of hydrogen from HTGR is approximately USD 35.6/GJ with an initial investment cost of USD 2.6 billion. If the unit cost of natural gas is USD 10/GJ, and the carbon tax is USD 0.08/kg of carbon dioxide, the unit cost of hydrogen produced from HTWR is approximately USD 13.92/GJ with initial investment of USD 2.32 billion. The unit cost of the hydrogen produced in the scaled-down plant was also considered.
- Open Access
Exergy and Thermoeconomic Analyses of a Carnot Battery System Comprising an Air Heat Pump and Steam Turbine
In this study, exergy and thermoeconomic analyses were performed on a Carnot battery system (CBS) comprising an air heat pump and steam turbine. The Carnot battery technology employed in this study stored electricity as heat for 10 h during night-time, when electricity prices were low, and generated electricity for 10 h with power output of 500 MW during the day, when electricity prices were relatively high. The roundtrip efficiency and the energy density of the CBS were approximately 0.37, and 150.0 MJ/m3, respectively. When the unit cost of electricity supplied to the heat pump system was approximately 23.0 USD/GJ, that of electricity produced by the steam turbine was approximately 70.8 USD/GJ. The thermoeconomic results indicate that the changes in electricity cost flow rate relative to the reference value can be used as an indicator to make purchasing, replacement, and research and development decisions for specific components of the CBS.
Open AccessExergy and Thermoeconomic Analyses of a Carnot Battery System Comprising an Air Heat Pump and Steam Turbine
In this study, exergy and thermoeconomic analyses were performed on a Carnot battery system (CBS) comprising an air heat pump and steam turbine. The Carnot battery technology employed in this study stored electricity as heat for 10 h during night-time, when electricity prices were low, and generated electricity for 10 h with power output of 500 MW during the day, when electricity prices were relatively high. The roundtrip efficiency and the energy density of the CBS were approximately 0.37, and 150.0 MJ/m3, respectively. When the unit cost of electricity supplied to the heat pump system was approximately 23.0 USD/GJ, that of electricity produced by the steam turbine was approximately 70.8 USD/GJ. The thermoeconomic results indicate that the changes in electricity cost flow rate relative to the reference value can be used as an indicator to make purchasing, replacement, and research and development decisions for specific components of the CBS.
- Open Access
Thermodynamic, Exergetic and Thermoeconomic Analyses of Double-Effect LiBr–Water Absorption Refrigeration Systems with a 5 kW High Temperature PEMFC as Heat Source for Data Center Applications
Thermodynamic, exergetic and thermoeconomic analyses were performed on two types of double-effect LiBr–water absorption refrigeration systems (ARS) for use with a 5-kW high-temperature proton exchange membrane fuel cell (HT-PEMFC) as a heat source. Proper temperatures of the high-pressure generator, combined generator and condenser, condenser, absorber and evaporator were determined to meet the requirements of constant cooling demands for data center operations. The heat balance of the combined unit of generator and condenser in the industrial double-effect LiBr-water ARS is important for determining the flow rate of the primary vapor refrigerant from the high-pressure generator. The industrial double-effect ARS system, whose analysis has not been studied analytically, outperformed the series double-effect system and provided 6.5 kW of cooling capacity with a coefficient of performance of 0.99. The unit cost of chilled water estimated by the modified productive structure analysis (MOPSA) method is approximately 7.18 USD/GJ (=0.026 US$/kWh). Effective exergetic efficiency of HT-PEMFC with the industrial ARS increases to 57.6% from 47.0%.
Open AccessThermodynamic, Exergetic and Thermoeconomic Analyses of Double-Effect LiBr–Water Absorption Refrigeration Systems with a 5 kW High Temperature PEMFC as Heat Source for Data Center Applications
Thermodynamic, exergetic and thermoeconomic analyses were performed on two types of double-effect LiBr–water absorption refrigeration systems (ARS) for use with a 5-kW high-temperature proton exchange membrane fuel cell (HT-PEMFC) as a heat source. Proper temperatures of the high-pressure generator, combined generator and condenser, condenser, absorber and evaporator were determined to meet the requirements of constant cooling demands for data center operations. The heat balance of the combined unit of generator and condenser in the industrial double-effect LiBr-water ARS is important for determining the flow rate of the primary vapor refrigerant from the high-pressure generator. The industrial double-effect ARS system, whose analysis has not been studied analytically, outperformed the series double-effect system and provided 6.5 kW of cooling capacity with a coefficient of performance of 0.99. The unit cost of chilled water estimated by the modified productive structure analysis (MOPSA) method is approximately 7.18 USD/GJ (=0.026 US$/kWh). Effective exergetic efficiency of HT-PEMFC with the industrial ARS increases to 57.6% from 47.0%.