Sharifah Fairuz Syed Fadzil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sharifah Fairuz Syed Fadzil has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Aasem Albdullatief
Department of Architecture and Building Sciences, College of Architecture and Planning, King Saud University, Riyadh, the Kingdom of Saudi Arabia
1 shared publication- Ali Ahmed Salem Bahdad
School of Housing, Building and Planning, Universiti Sains Malaysia, 11800, Penang, Malaysia
1 shared publication - David B. Dalumo
Faculty of Built Environment and Surveying, Universiti Teknologi Malaysia, Johor, Malaysia
1 shared publication - Hilary Omatule Onubi
Universiti Malaysia Perlis
1 shared publication - Mutaib I. Alsaadi
College of Engineering and Technology, University of Technology and Applied Sciences, Muscat, Oman.
1 shared publication - Najib Taher Al-Ashwal
Department of Architecture, Faculty of Built Environment and Surveying, Universiti Teknologi Malaysia, UTM Skudai, Johor 81310, Malaysia
1 shared publication
Latest Publications
- Open Access
- 30 March 2026
- Published by Al-Qadisiyah Journal for Engineering Sciences (QJES) in Al-Qadisiyah Journal for Engineering Sciences
- Vol. 19 (1) , 110-124
Impact of building envelope design modification on indoor temperature in classrooms in typical Omani schools
In Oman's hot-arid climate, school buildings often experience elevated indoor temperatures due to inefficient building envelope designs, resulting in a heavy reliance on air conditioning systems and high energy consumption. To address this issue, this study aims to evaluate indoor air temperature in typical Omani school buildings and determine how modifications to key envelope components, such as walls, roofs, and glazing, can improve indoor temperature conditions and enhance thermal comfort. A mixed-method approach was adopted, combining field measurements with computer simulation. Indoor temperature and relative humidity were monitored in selected classrooms, while DesignBuilder software was used to model existing conditions and test alternative envelope configurations. This integrated method is appropriate for quantifying the thermal performance of building envelopes under realistic climatic and operational settings. Results showed that baseline classrooms reached average indoor temperatures of 33 °C in summer and 24.5 °C in winter, exceeding recommended comfort limits during hot periods. The most effective design alternative reduced indoor temperature by up to 2.3 °C and increased the number of hours within the comfort range by 29%. The study concludes that optimizing wall insulation, roof composition, and glazing selection can significantly improve indoor thermal comfort and energy efficiency in Omani schools, providing practical design guidance for future educational buildings in hot-arid climates.
- 30 March 2026
- Published by Al-Qadisiyah Journal for Engineering Sciences (QJES) in Al-Qadisiyah Journal for Engineering Sciences
- Vol. 19 (1) , 110-124
Open AccessImpact of building envelope design modification on indoor temperature in classrooms in typical Omani schools
In Oman's hot-arid climate, school buildings often experience elevated indoor temperatures due to inefficient building envelope designs, resulting in a heavy reliance on air conditioning systems and high energy consumption. To address this issue, this study aims to evaluate indoor air temperature in typical Omani school buildings and determine how modifications to key envelope components, such as walls, roofs, and glazing, can improve indoor temperature conditions and enhance thermal comfort. A mixed-method approach was adopted, combining field measurements with computer simulation. Indoor temperature and relative humidity were monitored in selected classrooms, while DesignBuilder software was used to model existing conditions and test alternative envelope configurations. This integrated method is appropriate for quantifying the thermal performance of building envelopes under realistic climatic and operational settings. Results showed that baseline classrooms reached average indoor temperatures of 33 °C in summer and 24.5 °C in winter, exceeding recommended comfort limits during hot periods. The most effective design alternative reduced indoor temperature by up to 2.3 °C and increased the number of hours within the comfort range by 29%. The study concludes that optimizing wall insulation, roof composition, and glazing selection can significantly improve indoor thermal comfort and energy efficiency in Omani schools, providing practical design guidance for future educational buildings in hot-arid climates.
- 18 April 2022
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 31 (7) , 1963-1985
Balancing daylight in office spaces with respect to the indoor thermal environment through optimization of light shelves design parameters in the tropics
The study aims to investigate the preferred daylighting availability ranges for the best visual and thermal comfort in office workspace through optimal modifications light-shelve parameters, grounded on parametric design and optimization, with a focus on its visual and thermal indices. To identify the final optimal solutions, single and multi-optimization scenarios were used. The findings revealed that optimizing for a single objective might obstruct the attainment of other goals. In other words, the first scenario, optimization only for daylight availability, results in an increase in temperature. While optimizing for indoor thermal performance solely, none of the preset daylight availability acceptance requirements were met. However, multi-objective optimization solutions were the final optimal solutions nearest to the ideal. Final optimum solutions of the best design parameters of light shelves can improve the total average of daylight availability by 56.25%, 50.63%, 57.50% and 71.88%, and the indoor thermal performance was improved by decreasing the average temperature for thermal environmental performance indicators by 4.15%, 3.27%, 3.17% and 4.76%, respectively, in March, June, September and December. The study concludes that daylighting levels of 500 lux to1300 lux provide the best range of optimal daylighting for visual and thermal comfort indicators for office spaces in the tropics.
- 18 April 2022
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 31 (7) , 1963-1985
Balancing daylight in office spaces with respect to the indoor thermal environment through optimization of light shelves design parameters in the tropics
The study aims to investigate the preferred daylighting availability ranges for the best visual and thermal comfort in office workspace through optimal modifications light-shelve parameters, grounded on parametric design and optimization, with a focus on its visual and thermal indices. To identify the final optimal solutions, single and multi-optimization scenarios were used. The findings revealed that optimizing for a single objective might obstruct the attainment of other goals. In other words, the first scenario, optimization only for daylight availability, results in an increase in temperature. While optimizing for indoor thermal performance solely, none of the preset daylight availability acceptance requirements were met. However, multi-objective optimization solutions were the final optimal solutions nearest to the ideal. Final optimum solutions of the best design parameters of light shelves can improve the total average of daylight availability by 56.25%, 50.63%, 57.50% and 71.88%, and the indoor thermal performance was improved by decreasing the average temperature for thermal environmental performance indicators by 4.15%, 3.27%, 3.17% and 4.76%, respectively, in March, June, September and December. The study concludes that daylighting levels of 500 lux to1300 lux provide the best range of optimal daylighting for visual and thermal comfort indicators for office spaces in the tropics.