Caroline de Oliveira Nieblas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Caroline de Oliveira Nieblas has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Edward Araujo Júnior
Department of Obstetrics Paulista School of Medicine, Federal University of São Paulo (EPM‐UNIFESP) São Paulo Brazil
8 shared publications - Heron Werner
Department of Fetal Medicine Biodesign Laboratory DASA / PUC Rio de Janeiro Brazil
7 shared publications - Nathalie Jeanne Bravo-Valenzuela
Department of Pediatrics, Pediatric Cardiology, School of Medicine Federal University of Rio de Janeiro (UFRJ) Rio de Janeiro RJ Brazil
7 shared publications - Roberta Granese
Department of Biomedical and Dental Sciences and Morphofunctional Imaging, “G. Martino” University Hospital, Messina, Italy
3 shared publications - Carolina Giovanna Labinas Paroni2 shared publications
- Doris de Micena Silva Cunha da Costa2 shared publications
Latest Publications
- Open Access
- 18 October 2025
- Published by Springer Nature in Advances in Therapy
- Vol. 42 (12) , 6150-6162
Fetal Surgery for Congenital Heart Diseases: A Systematic Review and Single-Arm Meta-analysis
Introduction Congenital heart diseases (CHD) are the most common congenital anomalies, and fetal cardiac interventions (FCI) have been developed to improve perinatal outcomes. We aimed to conduct a systematic review and meta-analysis of observational studies to evaluate the effects of FCI on CHD. Methods We searched PubMed/Medline, Embase, and the Cochrane Central Register of Controlled Trials from inception to April 2025 without language restrictions. References of included studies and prior reviews were also screened. The protocol was registered in the International Prospective Register of Systematic Reviews (PROSPERO; ID CRD42024599628). Eligible studies included observational cohorts evaluating intrauterine procedures for CHD. Data were synthesized using random effects models in RStudio (version 4.2.2), and study quality was assessed with the Newcastle–Ottawa Quality Assessment Form for Cohort Studies (NOS). Results Twelve studies including 485 fetuses with CHD were analyzed. The pooled overall survival rate after fetal cardiac intervention was 57.4% (95% confidence interval [CI] 39.8–73.3), with survival ranging from 20.0% to 90.2% across studies. The pooled perinatal mortality rate was 31.5% (95% CI 21.0–44.2), with estimates ranging from 9.8% to 66.7%. Substantial heterogeneity was observed for both outcomes (I2 > 75%). Conclusion FCI for CHD are associated with moderate overall survival but substantial perinatal mortality. Standardized protocols, refined patient selection, and multicenter collaboration are needed to improve outcomes and guide clinical decision-making.
- 18 October 2025
- Published by Springer Nature in Advances in Therapy
- Vol. 42 (12) , 6150-6162
Open AccessFetal Surgery for Congenital Heart Diseases: A Systematic Review and Single-Arm Meta-analysis
Introduction Congenital heart diseases (CHD) are the most common congenital anomalies, and fetal cardiac interventions (FCI) have been developed to improve perinatal outcomes. We aimed to conduct a systematic review and meta-analysis of observational studies to evaluate the effects of FCI on CHD. Methods We searched PubMed/Medline, Embase, and the Cochrane Central Register of Controlled Trials from inception to April 2025 without language restrictions. References of included studies and prior reviews were also screened. The protocol was registered in the International Prospective Register of Systematic Reviews (PROSPERO; ID CRD42024599628). Eligible studies included observational cohorts evaluating intrauterine procedures for CHD. Data were synthesized using random effects models in RStudio (version 4.2.2), and study quality was assessed with the Newcastle–Ottawa Quality Assessment Form for Cohort Studies (NOS). Results Twelve studies including 485 fetuses with CHD were analyzed. The pooled overall survival rate after fetal cardiac intervention was 57.4% (95% confidence interval [CI] 39.8–73.3), with survival ranging from 20.0% to 90.2% across studies. The pooled perinatal mortality rate was 31.5% (95% CI 21.0–44.2), with estimates ranging from 9.8% to 66.7%. Substantial heterogeneity was observed for both outcomes (I2 > 75%). Conclusion FCI for CHD are associated with moderate overall survival but substantial perinatal mortality. Standardized protocols, refined patient selection, and multicenter collaboration are needed to improve outcomes and guide clinical decision-making.
- Open Access
- 30 September 2025
- Published by Medical Communications Sp. z.o.o. in Journal of Ultrasonography
- Vol. 25 (102) , 26
3D ultrasound of fetal congenital heart disease: findings from virtual and physical models
- 30 September 2025
- Published by Medical Communications Sp. z.o.o. in Journal of Ultrasonography
- Vol. 25 (102) , 26
Open Access3D ultrasound of fetal congenital heart disease: findings from virtual and physical models
- 21 August 2025
- Published by Revista ft Ltda in Revista ft
- Vol. 29 (149) , 43-44
ANÁLISE DO PERFIL EPIDEMIOLÓGICO DA DENGUE EM SÃO CAETANO DO SUL
- 21 August 2025
- Published by Revista ft Ltda in Revista ft
- Vol. 29 (149) , 43-44
ANÁLISE DO PERFIL EPIDEMIOLÓGICO DA DENGUE EM SÃO CAETANO DO SUL
- Open Access
- 13 December 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (24) , 7605
Three-Dimensional Ultrasound for Physical and Virtual Fetal Heart Models: Current Status and Future Perspectives
Congenital heart defects (CHDs) are the most common congenital defect, occurring in approximately 1 in 100 live births and being a leading cause of perinatal morbidity and mortality. Of note, approximately 25% of these defects are classified as critical, requiring immediate postnatal care by pediatric cardiology and neonatal cardiac surgery teams. Consequently, early and accurate diagnosis of CHD is key to proper prenatal and postnatal monitoring in a tertiary care setting. In this scenario, fetal echocardiography is considered the gold standard imaging ultrasound method for the diagnosis of CHD. However, the availability of this examination in clinical practice remains limited due to the need for a qualified specialist in pediatric cardiology. Moreover, in light of the relatively low prevalence of CHD among at-risk populations (approximately 10%), ultrasound cardiac screening for potential cardiac anomalies during routine second-trimester obstetric ultrasound scans represents a pivotal aspect of diagnosing CHD. In order to maximize the accuracy of CHD diagnoses, the views of the ventricular outflow tract and the superior mediastinum were added to the four-chamber view of the fetal heart for routine ultrasound screening according to international guidelines. In this context, four-dimensional spatio-temporal image correlation software (STIC) was developed in the early 2000s. Some of the advantages of STIC in fetal cardiac evaluation include the enrichment of anatomical details of fetal cardiac images in the absence of the pregnant woman and the ability to send volumes for analysis by an expert in fetal cardiology by an internet link. Sequentially, new technologies have been developed, such as fetal intelligent navigation echocardiography (FINE), also known as “5D heart”, in which the nine fetal cardiac views recommended during a fetal echocardiogram are automatically generated from the acquisition of a cardiac volume. Furthermore, artificial intelligence (AI) has recently emerged as a promising technological innovation, offering the potential to warn of possible cardiac anomalies and thus increase the ability of non-cardiology specialists to diagnose CHD. In the early 2010s, the advent of 3D reconstruction software combined with high-definition printers enabled the virtual and 3D physical reconstruction of the fetal heart. The 3D physical models may improve parental counseling of fetal CHD, maternal–fetal interaction in cases of blind pregnant women, and interactive discussions among multidisciplinary health teams. In addition, the 3D physical and virtual models can be an useful tool for teaching cardiovascular anatomy and to optimize surgical planning, enabling simulation rooms for surgical procedures. Therefore, in this review, the authors discuss advanced image technologies that may optimize prenatal diagnoses of CHDs.
- 13 December 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (24) , 7605
Open AccessThree-Dimensional Ultrasound for Physical and Virtual Fetal Heart Models: Current Status and Future Perspectives
Congenital heart defects (CHDs) are the most common congenital defect, occurring in approximately 1 in 100 live births and being a leading cause of perinatal morbidity and mortality. Of note, approximately 25% of these defects are classified as critical, requiring immediate postnatal care by pediatric cardiology and neonatal cardiac surgery teams. Consequently, early and accurate diagnosis of CHD is key to proper prenatal and postnatal monitoring in a tertiary care setting. In this scenario, fetal echocardiography is considered the gold standard imaging ultrasound method for the diagnosis of CHD. However, the availability of this examination in clinical practice remains limited due to the need for a qualified specialist in pediatric cardiology. Moreover, in light of the relatively low prevalence of CHD among at-risk populations (approximately 10%), ultrasound cardiac screening for potential cardiac anomalies during routine second-trimester obstetric ultrasound scans represents a pivotal aspect of diagnosing CHD. In order to maximize the accuracy of CHD diagnoses, the views of the ventricular outflow tract and the superior mediastinum were added to the four-chamber view of the fetal heart for routine ultrasound screening according to international guidelines. In this context, four-dimensional spatio-temporal image correlation software (STIC) was developed in the early 2000s. Some of the advantages of STIC in fetal cardiac evaluation include the enrichment of anatomical details of fetal cardiac images in the absence of the pregnant woman and the ability to send volumes for analysis by an expert in fetal cardiology by an internet link. Sequentially, new technologies have been developed, such as fetal intelligent navigation echocardiography (FINE), also known as “5D heart”, in which the nine fetal cardiac views recommended during a fetal echocardiogram are automatically generated from the acquisition of a cardiac volume. Furthermore, artificial intelligence (AI) has recently emerged as a promising technological innovation, offering the potential to warn of possible cardiac anomalies and thus increase the ability of non-cardiology specialists to diagnose CHD. In the early 2010s, the advent of 3D reconstruction software combined with high-definition printers enabled the virtual and 3D physical reconstruction of the fetal heart. The 3D physical models may improve parental counseling of fetal CHD, maternal–fetal interaction in cases of blind pregnant women, and interactive discussions among multidisciplinary health teams. In addition, the 3D physical and virtual models can be an useful tool for teaching cardiovascular anatomy and to optimize surgical planning, enabling simulation rooms for surgical procedures. Therefore, in this review, the authors discuss advanced image technologies that may optimize prenatal diagnoses of CHDs.
- Open Access
- 5 November 2024
- Published by MDPI AG in Preprints.org
Three-Dimensional Ultrasound, Physical and Virtual Fetal Heart Models: Current Status and Future Perspectives
Congenital heart defects (CHD) are the most common congenital defect, occurring in approximately 1 in 100 live births and being a leading cause of perinatal morbidity and mortality. Of note, approximately 25% of these defects are classified as critical, requiring immediate postnatal care by pediatric cardiology and neonatal cardiac surgery teams. Consequently, early and accurate diagnosis of CHD is key to proper prenatal and postnatal monitoring in a tertiary care setting. In this scenario, fetal echocardiography is considered the gold standard imaging ultrasound method for the diagnosis of CHD. However, the availability of this examination in clinical practice remains limited due to the requirement for a qualified specialist in pediatric cardiology. Moreover, in light of the relatively low prevalence of CHD among at-risk populations (approximately 10%), ultrasound cardiac screening for potential cardiac anomalies during routine second-trimester obstetric ultrasound scans represents a pivotal aspect of diagnosing CHD. In order to maximize the accuracy of CHD diagnosis, the views of the ventricular outflow tract and the superior mediastinum were added to the four-chamber view of the fetal heart for routine ultrasound screening according to international guidelines. In this context, four-dimensional spatio-temporal image correlation software (4D-STIC) were developed in the beginning 2000s. Some of the advantages of 4D-STIC in fetal cardiac evaluation include the enrichment of anatomical details of fetal cardiac images in the absence of the pregnant woman and the ability to send volumes for analysis by an expert in fetal cardiology by an internet link. Sequentially, new technologies have been developed such as Fetal Intelligent Navigation Echocardiography (FINE), also known as "5D-heart", in which the nine fetal cardiac views recommended during a fetal echocardiogram are automatically generated from the acquisition of a cardiac volume. Furthermore, artificial intelligence (AI) has recently emerged as a promising technological innovation, offering the potential to warn of possible cardiac anomalies and thus increase the ability of non-cardiology specialists to the diagnose of CHD. In the early 2010s, the advent of 3D reconstruction software combined with high-definition printers enabled virtual and 3D physical reconstruction of the fetal heart. The 3D physical models may improve parental counseling of fetal CHD, maternal-fetal interaction in cases of blind pregnant women, and interactive discussion by multidisciplinary health teams. In addition, the 3D physical and virtual models can be an useful tool for teaching of cardiovascular anatomy and to optimize surgical planning, enabling simulation rooms for surgical procedures. Therefore, in this review the authors discuss advanced image technologies aiming that may optimize the prenatal diagnosis of CHD.
- 5 November 2024
- Published by MDPI AG in Preprints.org
Open AccessThree-Dimensional Ultrasound, Physical and Virtual Fetal Heart Models: Current Status and Future Perspectives
Congenital heart defects (CHD) are the most common congenital defect, occurring in approximately 1 in 100 live births and being a leading cause of perinatal morbidity and mortality. Of note, approximately 25% of these defects are classified as critical, requiring immediate postnatal care by pediatric cardiology and neonatal cardiac surgery teams. Consequently, early and accurate diagnosis of CHD is key to proper prenatal and postnatal monitoring in a tertiary care setting. In this scenario, fetal echocardiography is considered the gold standard imaging ultrasound method for the diagnosis of CHD. However, the availability of this examination in clinical practice remains limited due to the requirement for a qualified specialist in pediatric cardiology. Moreover, in light of the relatively low prevalence of CHD among at-risk populations (approximately 10%), ultrasound cardiac screening for potential cardiac anomalies during routine second-trimester obstetric ultrasound scans represents a pivotal aspect of diagnosing CHD. In order to maximize the accuracy of CHD diagnosis, the views of the ventricular outflow tract and the superior mediastinum were added to the four-chamber view of the fetal heart for routine ultrasound screening according to international guidelines. In this context, four-dimensional spatio-temporal image correlation software (4D-STIC) were developed in the beginning 2000s. Some of the advantages of 4D-STIC in fetal cardiac evaluation include the enrichment of anatomical details of fetal cardiac images in the absence of the pregnant woman and the ability to send volumes for analysis by an expert in fetal cardiology by an internet link. Sequentially, new technologies have been developed such as Fetal Intelligent Navigation Echocardiography (FINE), also known as "5D-heart", in which the nine fetal cardiac views recommended during a fetal echocardiogram are automatically generated from the acquisition of a cardiac volume. Furthermore, artificial intelligence (AI) has recently emerged as a promising technological innovation, offering the potential to warn of possible cardiac anomalies and thus increase the ability of non-cardiology specialists to the diagnose of CHD. In the early 2010s, the advent of 3D reconstruction software combined with high-definition printers enabled virtual and 3D physical reconstruction of the fetal heart. The 3D physical models may improve parental counseling of fetal CHD, maternal-fetal interaction in cases of blind pregnant women, and interactive discussion by multidisciplinary health teams. In addition, the 3D physical and virtual models can be an useful tool for teaching of cardiovascular anatomy and to optimize surgical planning, enabling simulation rooms for surgical procedures. Therefore, in this review the authors discuss advanced image technologies aiming that may optimize the prenatal diagnosis of CHD.
- 23 April 2024
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 40 (5) , 1157-1158
Fetal transposition of the great arteries: 3D virtual and physical models from ultrasound datasets
Transposition of the great arteries (TGA) is a cyanotic congenital heart disease characterized by ventriculoarterial discordance and atrioventricular concordance with the great arteries in a parallel relationship. Prenatal diagnosis of TGA has implications for postnatal outcomes, allowing for planned delivery and perinatal management. Three-dimensional virtual or physical models of fetal TGA allow better understanding of fetal cardiac anomalies by parents and interactive discussion among the multidisciplinary team (obstetricians, pediatricians, maternal-fetal specialists, pediatric cardiologists, and cardiovascular surgeons), as well as continuing medical education.
- 23 April 2024
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 40 (5) , 1157-1158
Fetal transposition of the great arteries: 3D virtual and physical models from ultrasound datasets
Transposition of the great arteries (TGA) is a cyanotic congenital heart disease characterized by ventriculoarterial discordance and atrioventricular concordance with the great arteries in a parallel relationship. Prenatal diagnosis of TGA has implications for postnatal outcomes, allowing for planned delivery and perinatal management. Three-dimensional virtual or physical models of fetal TGA allow better understanding of fetal cardiac anomalies by parents and interactive discussion among the multidisciplinary team (obstetricians, pediatricians, maternal-fetal specialists, pediatric cardiologists, and cardiovascular surgeons), as well as continuing medical education.
- 15 April 2024
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 52 (6) , 789-791
Fetal tetralogy of Fallot: Three‐dimensional virtual and physical models from ultrasound scan data findings
Three-dimensional reconstructions provide a spatial view of the congenital heart disease with a better understanding of the pathology for parents and allow interactive discussion among the medical team (maternal-fetal medicine specialist, neonatology, pediatric cardiology, and cardiovascular surgeon) and improve both objective knowledge and learner satisfaction for medical students.
- 15 April 2024
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 52 (6) , 789-791
Fetal tetralogy of Fallot: Three‐dimensional virtual and physical models from ultrasound scan data findings
Three-dimensional reconstructions provide a spatial view of the congenital heart disease with a better understanding of the pathology for parents and allow interactive discussion among the medical team (maternal-fetal medicine specialist, neonatology, pediatric cardiology, and cardiovascular surgeon) and improve both objective knowledge and learner satisfaction for medical students.
- 28 March 2024
- Published by Wiley in Echocardiography
- Vol. 41 (4) , e15806
Ebstein anomaly: 3D virtual and physical models from obstetrical ultrasound data
3D virtual and physical models from ultrasound scan data allow a 3D spatial view of congenital heart anomalies, interactive discussion among a multidisciplinary team, and improved parental counseling. To the best of our knowledge, this is the first description of 3D physical and virtual models of a fetal Ebstein anomaly.
- 28 March 2024
- Published by Wiley in Echocardiography
- Vol. 41 (4) , e15806
Ebstein anomaly: 3D virtual and physical models from obstetrical ultrasound data
3D virtual and physical models from ultrasound scan data allow a 3D spatial view of congenital heart anomalies, interactive discussion among a multidisciplinary team, and improved parental counseling. To the best of our knowledge, this is the first description of 3D physical and virtual models of a fetal Ebstein anomaly.
- Open Access
- 15 January 2024
- Published by Revista de Epidemiologia e Saúde Pública in Revista de Epidemiologia e Saúde Pública - RESP
- Vol. 2 (1)
USO DA INTELIGÊNCIA ARTIFICIAL NA MEDICINA CONTEMPORÂNEA - UMA REVISÃO INTEGRATIVA
Objetivo: Analisando os impactos do uso da inteligência artificial na área médica, o estudo é justificado pelo uso crescente da I.A no segmento da saúde, não só por acadêmicos de medicina, mas também por médicos residentes e especialistas com carreira consagrada, visando questionar qual é o impacto da aplicação de tais ferramentas e quais as perspectivas futuras para a saúde da população. Métodos: A revisão integrativa buscou dados com descritores “Inteligência Artificial”, “Medicina” e “Tecnologia Médica” nas bases indexadas na Biblioteca Virtual de Saúde, PubMED e SciElo publicados nos últimos 5 anos em inglês e português. Excluíram-se publicações que estivessem outras línguas, publicações duplicadas, eixo temático fora do uso da inteligência artificial na medicina e que não estivessem em formato de artigo. Discussão e Resultados: Foram encontrados 165 artigos, e selecionados para leitura integral, 15 artigos que correspondiam às delimitações de inclusão e exclusão, e posteriormente classificados conforme os critérios Qualis e Fator de Impacto da revista. Dos artigos avaliados, 6,6%: Qualis B3, 6,6%: Qualis A4, 6,6% Qualis A3, 20% Qualis A2, 40%: Qualis A1 e 20% sem Qualis. O foco dos autores aponta que a modelagem Deep Learning é um dos tipos de I.A que possibilita o achado de padrões sutis em imagens, que pode ser aplicado em áreas como patologia, dermatologia, neurologia e radiologia. Conclusão: Existem preocupações em relação à confiança quando ao uso a I.A. Neste aspecto existe certo viés da I.A na prática médica, o que pode levar a sobrediagnósticos ou subdiagnósticos caso o profissional não esteja preparado para o seu uso.
- 15 January 2024
- Published by Revista de Epidemiologia e Saúde Pública in Revista de Epidemiologia e Saúde Pública - RESP
- Vol. 2 (1)
Open AccessUSO DA INTELIGÊNCIA ARTIFICIAL NA MEDICINA CONTEMPORÂNEA - UMA REVISÃO INTEGRATIVA
Objetivo: Analisando os impactos do uso da inteligência artificial na área médica, o estudo é justificado pelo uso crescente da I.A no segmento da saúde, não só por acadêmicos de medicina, mas também por médicos residentes e especialistas com carreira consagrada, visando questionar qual é o impacto da aplicação de tais ferramentas e quais as perspectivas futuras para a saúde da população. Métodos: A revisão integrativa buscou dados com descritores “Inteligência Artificial”, “Medicina” e “Tecnologia Médica” nas bases indexadas na Biblioteca Virtual de Saúde, PubMED e SciElo publicados nos últimos 5 anos em inglês e português. Excluíram-se publicações que estivessem outras línguas, publicações duplicadas, eixo temático fora do uso da inteligência artificial na medicina e que não estivessem em formato de artigo. Discussão e Resultados: Foram encontrados 165 artigos, e selecionados para leitura integral, 15 artigos que correspondiam às delimitações de inclusão e exclusão, e posteriormente classificados conforme os critérios Qualis e Fator de Impacto da revista. Dos artigos avaliados, 6,6%: Qualis B3, 6,6%: Qualis A4, 6,6% Qualis A3, 20% Qualis A2, 40%: Qualis A1 e 20% sem Qualis. O foco dos autores aponta que a modelagem Deep Learning é um dos tipos de I.A que possibilita o achado de padrões sutis em imagens, que pode ser aplicado em áreas como patologia, dermatologia, neurologia e radiologia. Conclusão: Existem preocupações em relação à confiança quando ao uso a I.A. Neste aspecto existe certo viés da I.A na prática médica, o que pode levar a sobrediagnósticos ou subdiagnósticos caso o profissional não esteja preparado para o seu uso.
- Open Access
- 22 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (23) , 3509
Evolution of Fetal Cardiac Imaging over the Last 20 Years
The purpose of this article is to describe the evaluation of a variety of congenital heart diseases (CHDs) using three-dimensional (3D) ultrasound with different software, such as Cristal Vue, Realistic Vue, LumiFlow, and Spatiotemporal Image Correlation (STIC), with HDlive and HDlive Flow Silhouette modes. These technologies provide realistic images of the fetal heart and cardiac vessels using a fixed virtual light source that allows the operator to freely select a better light source position to enhance the cardiovascular anatomical details. In addition, Fetal Intelligent Navigation Echocardiography (FINE) technology, also known as “5D Heart” or “5D”, is a technology that enables the automatic reconstruction of the nine standard fetal echocardiographic views and can alert non-specialists to suspected CHD. Through the use of artificial intelligence, an ultrasound machine is able to perform automatic anatomical and functional measurements. In addition, hese technologies enable the reconstruction of fetal cardiac structures in realistic images, improving the depth perception and resolution of anatomic cardiac details and blood vessels compared to those of standard two-dimensional (2D) ultrasound.
- 22 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (23) , 3509
Open AccessEvolution of Fetal Cardiac Imaging over the Last 20 Years
The purpose of this article is to describe the evaluation of a variety of congenital heart diseases (CHDs) using three-dimensional (3D) ultrasound with different software, such as Cristal Vue, Realistic Vue, LumiFlow, and Spatiotemporal Image Correlation (STIC), with HDlive and HDlive Flow Silhouette modes. These technologies provide realistic images of the fetal heart and cardiac vessels using a fixed virtual light source that allows the operator to freely select a better light source position to enhance the cardiovascular anatomical details. In addition, Fetal Intelligent Navigation Echocardiography (FINE) technology, also known as “5D Heart” or “5D”, is a technology that enables the automatic reconstruction of the nine standard fetal echocardiographic views and can alert non-specialists to suspected CHD. Through the use of artificial intelligence, an ultrasound machine is able to perform automatic anatomical and functional measurements. In addition, hese technologies enable the reconstruction of fetal cardiac structures in realistic images, improving the depth perception and resolution of anatomic cardiac details and blood vessels compared to those of standard two-dimensional (2D) ultrasound.