CEColin Elliott

Colin Elliott

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Colin Elliott has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The analysis of post-mortem fluorescent signatures in discarded cell lysate from DNA extractions: a comparative study between pig and human remains

    by Colin I. Elliott, Aaron B. A. Shafer, Shari L. Forbes, Theresa Stotesbury

    Using fluorimetry to probe post-mortem biomolecular changes in soft tissue of pig and human remains in a northern continental climate.


  • Open Access

    Fluorescence-based post-mortem interval estimation using cell lysate from DNA/RNA co-extraction of human soft tissue

    by Colin I. Elliott, Aaron B.A. Shafer, Shari L. Forbes, Theresa Stotesbury

    Post-mortem interval (PMI) estimation is an important element in medico-legal death investigations, as reliable estimates can establish timelines and generate investigative leads. Various analytical techniques are used to monitor biomolecular degradation throughout decomposition, with promising results obtained from fluorescence spectroscopy. In this work, we analyzed the fluorescent profile of cell lysates from 96 biopsy punches collected from 14 human cadavers at a human taphonomic facility in Québec, Canada, with PMIs ranging from 2 to 1098 days. Excitation-emission matrices (EEMs) were acquired for each lysate and deconvoluted using parallel factor analysis for fluorophore identification. We analyzed both composite and tissue-specific (muscle, adipose, and skin) samples. Overall, tryptophan fluorescence decreased with increasing PMI, whereas fluorescence between 400-500 nm, attributed to fluorescent oxidation products, increased. Fluorescence in skin and muscle was dominated by tryptophan at early PMIs, whereas adipose exhibited minimal signal. As PMI increased, EEM fluorescence became progressively more homogeneous across tissue types, indicating that tissue-specific contributions decrease as decomposition advances. Six machine learning models were built from the composite samples to predict PMI, and XGBoost performed best, with an R 2  of 0.88 and RMSE of 127.2 days, corresponding to an error of 11.6% relative to the maximum PMI. Our findings demonstrate that fluorescence analysis of cell lysates is practical and yields accurate PMI estimates, provides important insight into decomposition-related biomolecular degradation, and can also be readily integrated into DNA/RNA co-extractions.

  • Open Access

    Impact of 2′-fluoro nucleobase modifications on CD detection, sensitivity and specificity of short oligonucleotides bound to alginate hydrogels

    by Daisee K. Lubrin, Colin I. Elliott, Jean-Paul Desaulniers, Theresa Stotesbury

    We discuss the synthesis, characterization, and analysis of label-free, short oligonucleotide-bound alginate hydrogels and improved function with 2′-fluoro nucleobase modification.

  • Open Access

    Impact of 2’-fluoro nucleobase modifications on CD detection, sensitivity and specificity of short oligonucleotides bound to alginate hydrogels

    by Daisee Lubrin, Colin Elliott, Jean-Paul Desaulniers, Theresa Stotesbury

    Chemical modification of oligonucleotides has aided in the advancement of various therapeutic applications; however, their impact on biosensor performance remains understudied. As demand grows for rapid, sensitive, and portable detection technologies in healthcare, environmental, and forensic fields, leveraging the effects of chemical modifications with spectroscopic detection methods offers an opportunity to improve biosensor performance. Herein, we synthesize label-free oligonucleotide-bound alginate hydrogels as biosensors and use circular dichroism (CD) spectroscopy to detect and confirm DNA and RNA hybridization without amplification or labelling. We particularly focus on the impact of 2’-fluoro modifications on biosensor sensitivity and specificity. Fluorine-modified DNA-based biosensors demonstrate more than a threefold increase in sensitivity compared to unmodified DNA. RNA-based biosensors displayed a similar trend, where 2’-fluoro nucleobase modifications significantly lowered the LOD. Biosensor specificity is evaluated by adding mixtures containing up to four non-complementary strands to the alginate-oligo hydrogels. Fluorine-modified biosensors consistently demonstrated greater specificity with more distinct shifts in CD spectra compared to unmodified DNA. Principal component analysis was applied to differentiated samples with and without a bound complement. Additionally, when thermal melt data was combined with CD spectral data it was possible with a random forest model to predict whether unknown samples demonstrated complement binding, with accuracies of 95 % and 83% for 2’-F modified and unmodified oligos, respectively. Our findings highlight the enhancement in biosensor sensitivity and specificity conferred by 2’-fluoro modifications, demonstrating their potential for improved label-free, amplification-free detection of oligonucleotides in complex environmental and forensic samples.

  • Open Access

    Encapsulation of degraded DNA in alginate hydrogels: rheological characterization and applicability to forensic science

    by Colin Elliott, Theresa Stotesbury

    Forensic biomaterials are on the rise, with efforts in developing ex vivo tissue and blood mimetics. Incorporation of small and degraded DNA into these materials has implications for research and training across many areas of forensic science. Large fragments of highly concentrated genomic and phage DNA in solution have been characterized using rheology; however, this amount and size of DNA are atypical in DNA extracted from forensic evidence. In this work, we investigated how adding synthetic DNA oligos and genomic DNA extracted from bloodstains deposited for up to 19 months influenced the rheological properties of polymer systems intended for forensic biomaterial synthesis. We found that encapsulating DNA within an alginate-based, ionically crosslinked hydrogel produced the greatest differentiation in rheological profiles among DNA with varying physical properties. The different conformations and sizes of encapsulated DNA oligos exhibited significantly different responses during strain amplitude sweeps (p<0.05). We also observed moderate correlations between the rheological responses and the time since deposition of bloodstains used for DNA extraction (r = -0.57 to r = 0.62). This indicates that dilute, polydisperse and degraded genomic DNA extracts can effectively modulate the rheological properties of the encapsulating hydrogel. Our results demonstrate the viability of using rheology as a technique to analyze encapsulated dilute DNA oligos and degraded DNA while highlighting the need to consider the type of oligos included in forensic biomaterials.

  • Open Access

    Integrating time since deposition estimation of bloodstains into a DNA profiling workflow: A novel approach using fluorescence spectroscopy

    by Colin Elliott, Denina Simmons, Theresa Stotesbury

    Determining the time since deposition (TSD) of bloodstains is important to establish a timeline and contextualize physical evidence in forensic investigations, while DNA profiling addresses questions of identity and source attribution. Traditionally treated as separate processes, this study integrates TSD estimation into routine DNA profiling by analyzing typically discarded cell lysate (eluates) from spin-column-based DNA extractions. Fluorescence spectroscopy was used to analyze eluates from bloodstains deposited up to 23 months (99 weeks). Two excitation-emission matrices (EEMs) were acquired for each sample and deconvoluted using parallel factor analysis (PARAFAC) to identify individual fluorophores. We identified tryptophan and noted a time-dependent decrease in its corresponding fluorescence. An increase in fluorescence was observed between 400-500 nm as TSD progressed, attributed to an increase in fluorescent oxidation products (FOX) and advanced glycation end products (AGEs). Different chemometric models were then used to estimate TSD from EEM fluorescence data. Boruta feature selection coupled with random forest regression outperformed all other models and achieved high accuracy, with an R2 of 0.993 and root mean square error of prediction (RMSEP) of 2.83 weeks for the full 99-week period, and an R2 of 0.987 and RMSEP of 2.06 weeks for the 1-year timeframe. Comparisons were also made between anticoagulant-free (AC-free) and anticoagulant-treated (AC-treated) bloodstains deposited up to 3 months. We noted differences in fluorescence based on AC treatment, with AC-free blood exhibiting higher FOX and lower AGE fluorescence than AC-treated blood. A temperature study was also performed using bloodstains deposited at -18 ºC, 4 ºC and 21 ºC, with the strongest FOX and AGE fluorescence recorded at 21 ºC. Our findings demonstrate the effectiveness and feasibility of integrating TSD estimation into routine forensic DNA analyses while maintaining high prediction accuracies.

  • Optical profilometry for forensic bloodstain imaging

    by Brayden Vale, Amanda Orr, Colin Elliott, Theresa Stotesbury

    Understanding the physical, chemical and biological changes that occur during the drying of a bloodstain is important in many aspects of forensic science including bloodstain pattern analysis and time since deposition estimation. This research assesses the use of optical profilometry to analyze changes in the surface morphology of degrading bloodstains created using three different volumes (4, 11, and 20 μL) up to 4 weeks after deposition. We analyzed six surface characteristics, including surface average roughness, kurtosis, skewness, maximum height, number of cracks and pits, and height distributions from the topographical scans obtained from bloodstains. Full and partial optical profiles were obtained to examine long‐term (minimum of 1.5‐h intervals) and short‐term (5‐min intervals) changes. The majority of the changes in surface characteristics occurred within the first 35 min after bloodstain deposition, in agreement with current research in bloodstain drying. Optical profilometry is a nondestructive and efficient method to obtain surface profiles of bloodstains, and can be integrated easily into additional research workflows including but not limited to time since deposition estimation. Optical profilometry is a non‐contact tool to scan bloodstains in ambient conditions Drying phases are observable in small drip bloodstains Significant surface morphology changes occur within 35 min after deposition


  • Using totalRNAquality metrics for time since deposition estimates in degrading bloodstains

    by Colin I. Elliott, Theresa E. Stotesbury, Aaron B. A. Shafer

    The physicochemical changes occurring in biomolecules in degrading bloodstains can be used to approximate the time since deposition (TSD) of bloodstains. This would provide forensic scientists with critical information regarding the timeline of the events involving bloodshed. Our study aims to quantify the timewise degradation trends and temperature dependence found in total RNA from bloodstains without the use of amplification, expanding the scope of the RNA TSD research which has traditionally targeted mRNA and miRNA. Bovine blood with ACD‐A anticoagulant was deposited and stored in plastic microcentrifuge tubes at 21 or 4°C and tested over different timepoints spanning 1 week. Total RNA was extracted from each sample and analyzed using automated high sensitivity gel electrophoresis. Nine RNA metrics were visually assessed and quantified using linear and mixed models. The RNA Integrity Number equivalent (RINe) and DV200 were not influenced by the addition of anticoagulant and demonstrated strong negative trends over time. The RINe model fit was high (R2 = 0.60), and while including the biological replicate as a random effect increased the fit for all RNA metrics, no significant differences were found between biological replicates stored at the same temperature for the RINe and DV200. This suggests that these standardized metrics can be directly compared between scenarios and individuals, with DV200 having an inflection point at approximately 28 h. This study provides a novel approach for blood TSD research, revealing metrics that are not affected by inter‐individual variation, and improving our understanding of the rapid RNA degradation occurring in bloodstains.