TRThomas Ruland

Thomas Ruland

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thomas Ruland has a total of 480 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Beta-Decay Half-Lives beyond Ca 54 : A Systematic Survey of Decay Properties Approaching the Neutron Dripline

    by W.-J. Ong, Z. Y. Xu, R. Grzywacz, A. Ravlić, I. Cox, J. M. Allmond, T. T. King, B. C. Rasco, K. P. Rykaczewski, H. Schatz, et al.

    In an experiment performed at the Facility for Rare Isotope Beams (FRIB) using the FRIB Decay Station initiator, 15 new half-lives of isotopes near ^{54}Ca were measured. A new method of extracting lifetimes from experimental data, taking into account the unknown β-delayed neutron emission branches of very neutron-rich nuclei, was developed to enable systematic uncertainty analysis. The experiment observed a dramatic change in the half-life systematics for the isotopes with neutron number N=34. Beyond N=34, the decline of nuclear lifetime is much slower, leading to longer than anticipated lifetimes for near-dripline nuclei. State-of-the-art shell-model calculations can explain the experimental results, revealing the imprint of shell effects and the need for modification of single-particle neutron states. The results from a newly developed quasirandom-phase approximation model with potential for making global predictions were also tested against the experimental results and good agreement was found.


  • Robust β -spectra shape parameter extraction

    by B. C. Rasco, T. J. Gray, T. Ruland

  • Top Cited Papers
    Open Access

    First Results on the Search for Lepton Number Violating Neutrinoless Double- β Decay with the LEGEND-200 Experiment

    by H Acharya, N Ackermann, M Agostini, A Alexander, C Andreoiu, G R Araujo, F T Avignone, M Babicz, W Bae, A M Bakalyarov, et al.

    The LEGEND Collaboration is searching for neutrinoless double-beta ( 0 ν β β ) decay by operating high-purity germanium detectors enriched in Ge 76 in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0 ν β β decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5 − 0.2 + 0.3 cts / ( keV ton yr ) in the 0 ν β β decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 × 10 26 yr on the half-life of 0 ν β β decay, reveals no evidence for a signal and sets a new observed lower limit at T 1 / 2 0 ν > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range m β β < 75 – 200 meV , depending on the adopted nuclear matrix element.


  • Open Access

    High-resolution 3D-printed plastic scintillators with tertiary dye

    by C.J. Moore, M. Febbraro, J.J. Manfredi, A. Wood, D. Rutstrom, T. Ruland, B. Hackett, P.A. Hausladen

    Additive manufacturing offers efficient production of plastic scintillators with nontrivial geometries using vat polymerization, allowing fabrication of geometries which would be difficult or even impossible to produce using conventional subtractive manufacturing. This work presents a novel photocurable scintillator formula that includes coumarin 450 as a tertiary dye to enable high-resolution 3D printing via the manipulation of the 405 nm cure light. Bulk photocured and 3D printed (with and without tertiary dye) samples were compared through observational assessment and spectral response. All samples showed pulse shape discrimination between neutron and gamma events. Inclusion of the tertiary dye has minimal impact on emission spectrum and light output, but significant impact on print resolution as shown by comparison of printed high-complexity geometries and feature resolution test objects. With the use of a cure-limiting dye, unsupported features — such as freestanding pillars — were resolvable down to 0.7 mm. Even finer resolution at or below 0.1 mm was achieved in fully supported, integrated structures printed with off-the-shelf 405 nm desktop 3D printer. Scintillators demonstrated a light output up to 50% of EJ-200 with a PSD figure of merit up to 1.35 at 0.9–1.1 MeVee.


  • Open Access

    Developments to the Distributed Holdup Monitoring System in Fiscal Year 2025

    by Usdoe, K. Goetz, Brett Witherspoon, Nicholas Prins, Thomas Ruland, Chuck Britton Jr., Landon B Crawford, Jesse Davis, Callie Goetz

  • Universal Effective Charges in the sd and fp Shells

    by T. H. Ogunbeku, J. M. Allmond, T. J. Gray, W.-J. Ong, B. A. Brown, A. Gargano, R. Grzywacz, J. D. Holt, A. O. Macchiavelli, T. Miyagi, et al.

    The 247-keV state in ^{54}Sc, populated in the β decay of ^{54}Ca, is reported here as a nanosecond isomer with a half-life of 26.0(22) ns. The state is interpreted as the 1^{+} member of the πf_{7/2}⊗νf_{5/2} spin-coupled multiplet, which decays to the 3^{+},πf_{7/2}⊗νp_{1/2} ground state. The new half-life corresponds to a pure E2 transition with a strength of 1.93(16) W.u., providing the most precise, unambiguous B(E2) value in the neutron-rich fp region to date for a nucleus with valence protons above Z=20. Notably, it is roughly 4 times larger than the B(E2;1/2^{-}→5/2^{-}) value in ^{55}Ca. The results, as compared to semiempirical and ab initio shell-model calculations, indicate (1) a weak N=34 subshell gap relative to N=32, (2) a large E2 enhancement in Sc as compared to Ca due to 1p-1h proton excitations across Z=28, and (3) empirical effective proton and neutron charges e_{π}=1.30(8)e and e_{ν}=0.452(7)e, respectively, that are in contrast to reports of e_{π}≈1.1-1.15e and e_{ν}≈0.6-0.8e for fp-shell nuclei near N=Z. We demonstrate that these reports are erroneous and that, in fact, a universal set of effective charges can be used across the sd and fp shells.


  • Open Access

    Machine learning enabled measurements of astrophysical ( p,n ) reactions with the SECAR recoil separator

    by P. Tsintari, N. Dimitrakopoulos, R. Garg, K. Hermansen, C. Marshall, F. Montes, G. Perdikakis, H. Schatz, K. Setoodehnia, H. Arora, et al.

    The synthesis of heavy elements in supernovae is affected by low-energy ( n , p ) and ( p , n ) reactions on unstable nuclei, yet experimental data on such reaction rates are scarce. The SECAR (SEparator for CApture Reactions) recoil separator at FRIB (Facility for Rare Isotope Beams) was originally designed to measure astrophysical reactions that change the mass of a nucleus significantly. We used a novel approach that integrates machine learning with ion-optical simulations to find an ion-optical solution for the separator that enables the measurement of ( p , n ) reactions, despite the reaction leaving the mass of the nucleus nearly unchanged. A new measurement of the Fe 58 ( p , n ) Co 58 reaction in inverse kinematics with a 3.66 ± 0.12 MeV/nucleon Fe 58 beam (corresponding to 3.69 ± 0.12 MeV proton energy in normal kinematics) yielded a cross-section of 20.3 ± 6.3 mb and served as a proof of principle experiment for the new technique demonstrating its effectiveness in achieving the required performance criteria. This novel approach paves the way for studying astrophysically important ( p , n ) reactions on unstable nuclei produced at FRIB.


  • Microsecond Isomer at the N=20 Island of Shape Inversion Observed at FRIB

    by T. J. Gray, J. M. Allmond, Z. Xu, T. T. King, R. S. Lubna, H. L. Crawford, V. Tripathi, B. P. Crider, R. Grzywacz, S. N. Liddick, et al.

    Excited-state spectroscopy from the first experiment at the Facility for Rare Isotope Beams (FRIB) is reported. A 24(2)−μs isomer was observed with the FRIB Decay Station initiator (FDSi) through a cascade of 224- and 401-keV γ rays in coincidence with Na32 nuclei. This is the only known microsecond isomer (1  μs≤T1/2<1  ms) in the region. This nucleus is at the heart of the N=20 island of shape inversion and is at the crossroads of the spherical shell-model, deformed shell-model, and ab initio theories. It can be represented as the coupling of a proton hole and neutron particle to Mg32, Mg32+π−1+ν+1. This odd-odd coupling and isomer formation provides a sensitive measure of the underlying shape degrees of freedom of Mg32, where the onset of spherical-to-deformed shape inversion begins with a low-lying deformed 2+ state at 885 keV and a low-lying shape-coexisting 02+ state at 1058 keV. We suggest two possible explanations for the 625-keV isomer in Na32: a 6− spherical shape isomer that decays by E2 or a 0+ deformed spin isomer that decays by M2. The present results and calculations are most consistent with the latter, indicating that the low-lying states are dominated by deformation.


  • Open Access

    Fast-, Light-Cured Scintillating Plastic for 3D-Printing Applications

    by Brian G. Frandsen, Michael Febbraro, Thomas Ruland, Theodore W. Stephens, Paul A. Hausladen, Juan J. Manfredi, James E. Bevins

    Additive manufacturing techniques enable a wide range of possibilities for novel radiation detectors spanning simple to highly complex geometries, multi-material composites, and metamaterials that are either impossible or cost prohibitive to produce using conventional methods. The present work identifies a set of promising formulations of photocurable scintillator resins capable of neutron-gamma pulse shape discrimination (PSD) to support the additive manufacturing of fast neutron detectors. The development of these resins utilizes a step-by-step, trial-and-error approach to identify different monomer and cross-linker combinations that meet the requirements for 3D printing followed by a 2-level factorial parameter study to optimize the radiation detection performance, including light yield, PSD, optical clarity, and hardness. The formulations resulted in hard, clear, PSD-capable plastic scintillators that were cured solid within 10 s using 405 nm light. The best-performing scintillator produced a light yield 83% of EJ-276 and a PSD figure of merit equaling 1.28 at 450–550 keVee.