Pedro M. Prieto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pedro M. Prieto has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
- Pablo Artal
Laboratorio de Óptica, Universidad de Murcia, Murcia, Spain
41 shared publications - Enrique Josua Fernández
Laboratorio de ptica, Instituto Universitario de Investigacin en ptica y Nanofsica, Campus de Espinardo (Ed. 34), CEIR Campus Mare Nostrum (CMN), Universidad de Murcia, Murcia, Spain
14 shared publications - Silvestre Manzanera
Universidad de Murcia
11 shared publications M. P. Cagigal
6 shared publications- Christina Schwarz
Aalen University
5 shared publications Manuel P. Cagigal
Departamento de Fisica Aplicada, Universidad de Cantabria, Los Castros S/N, Santander 39005, Spain
5 shared publications
Latest Publications
- 10 March 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (4) , 1782-1793
Effect of spherical aberration on the vergence-accommodation conflict
We used a binocular adaptive optics visual simulator with vergence control to investigate the impact of spherical aberration (SA) profiles on different degrees of vergence-accommodation conflict (VAC). Stereoacuity and subjective discomfort were measured in ten subjects under three SA conditions (0, -0.24, and -0.43 µm for a 4.5-mm pupil) and three vergence disparities: -1.5 D (parallel lines of sight), 0 D, and +1.5 D (eyes converging at 33 cm), relative to a screen placed at an accommodative distance of 1.5 D. Baseline naked-eye stereoacuity was consistent with published values and showed deterioration for negative conflict (object closer than the vergence point). Adding SA did not substantially improve visual performance, possibly providing a small advantage for negative conflict but producing the opposite effect for positive conflict. No overall improvement was found in comfort level, as the subjective questionnaires revealed opposite tendencies when SA was introduced: discomfort decreased for negative VAC and increased for positive and no conflict. However, the key implication is that an intermediate amount of SA may equalize discomfort across conflict conditions, potentially reducing fatigue during prolonged viewing by avoiding peaks of visual distress. While further research is needed, this finding could have practical relevance in extended reality (ER) systems, as incorporating extended-depth-of-focus (EDoF) optics, either within the device or in the user’s eye (e.g., through contact lenses), could provide a simple and cost-effective means to improve user experience.
- 10 March 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (4) , 1782-1793
Effect of spherical aberration on the vergence-accommodation conflict
We used a binocular adaptive optics visual simulator with vergence control to investigate the impact of spherical aberration (SA) profiles on different degrees of vergence-accommodation conflict (VAC). Stereoacuity and subjective discomfort were measured in ten subjects under three SA conditions (0, -0.24, and -0.43 µm for a 4.5-mm pupil) and three vergence disparities: -1.5 D (parallel lines of sight), 0 D, and +1.5 D (eyes converging at 33 cm), relative to a screen placed at an accommodative distance of 1.5 D. Baseline naked-eye stereoacuity was consistent with published values and showed deterioration for negative conflict (object closer than the vergence point). Adding SA did not substantially improve visual performance, possibly providing a small advantage for negative conflict but producing the opposite effect for positive conflict. No overall improvement was found in comfort level, as the subjective questionnaires revealed opposite tendencies when SA was introduced: discomfort decreased for negative VAC and increased for positive and no conflict. However, the key implication is that an intermediate amount of SA may equalize discomfort across conflict conditions, potentially reducing fatigue during prolonged viewing by avoiding peaks of visual distress. While further research is needed, this finding could have practical relevance in extended reality (ER) systems, as incorporating extended-depth-of-focus (EDoF) optics, either within the device or in the user’s eye (e.g., through contact lenses), could provide a simple and cost-effective means to improve user experience.
- 10 September 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (10) , 4017-4026
Binocular adaptive optics visual simulator with convergence control
We present a new generation of binocular adaptive optics visual simulator (B-AOVS). As in earlier versions, the system optimizes hardware use by managing both eyes with a single intensity spatial light modulator for pupil control and a single phase modulator for aberration manipulation, both of them based on liquid-crystal-on-silicon (LCoS) technology. A single Hartmann-Shack sensor measures refraction and aberrations in both eyes, and a single tunable lens extends the correction and measurement range. Only the stimulus generation module is duplicated, using two HD microdisplays to ensure adequate resolution and field of view. The main improvement in this prototype is the addition of a motorized twin-periscope system that adjusts the vergence angle of the stimuli, enabling more realistic visual testing at multiple distances. Among other applications, this feature paves the way for studies requiring accommodative changes that would be otherwise unfeasible due to the vergence-accommodation conflict. For this particular reason, studies with past generations of B-AOVS were typically carried out in presbyopes or cyclopleged subjects, on the assumption that avoiding the conflict by preventing accommodation would render convergence irrelevant. To specifically test this assumption, our first use of the prototype was to measure defocus curves in one presbyopic and four cyclopleged subjects for varying levels of induced spherical aberration, with and without convergence control. In this non-accommodative situation, convergence showed minimal influence, as defocus curves remained similar, and therefore the validity of previous studies with B-AOVS under fixed convergence conditions remains unchallenged. Beyond this case, the new vergence control system enables accurate 3D stimulus presentation for visual simulation and opens avenues to study the impact of aberrations on the vergence–accommodation conflict.
- 10 September 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (10) , 4017-4026
Binocular adaptive optics visual simulator with convergence control
We present a new generation of binocular adaptive optics visual simulator (B-AOVS). As in earlier versions, the system optimizes hardware use by managing both eyes with a single intensity spatial light modulator for pupil control and a single phase modulator for aberration manipulation, both of them based on liquid-crystal-on-silicon (LCoS) technology. A single Hartmann-Shack sensor measures refraction and aberrations in both eyes, and a single tunable lens extends the correction and measurement range. Only the stimulus generation module is duplicated, using two HD microdisplays to ensure adequate resolution and field of view. The main improvement in this prototype is the addition of a motorized twin-periscope system that adjusts the vergence angle of the stimuli, enabling more realistic visual testing at multiple distances. Among other applications, this feature paves the way for studies requiring accommodative changes that would be otherwise unfeasible due to the vergence-accommodation conflict. For this particular reason, studies with past generations of B-AOVS were typically carried out in presbyopes or cyclopleged subjects, on the assumption that avoiding the conflict by preventing accommodation would render convergence irrelevant. To specifically test this assumption, our first use of the prototype was to measure defocus curves in one presbyopic and four cyclopleged subjects for varying levels of induced spherical aberration, with and without convergence control. In this non-accommodative situation, convergence showed minimal influence, as defocus curves remained similar, and therefore the validity of previous studies with B-AOVS under fixed convergence conditions remains unchallenged. Beyond this case, the new vergence control system enables accurate 3D stimulus presentation for visual simulation and opens avenues to study the impact of aberrations on the vergence–accommodation conflict.
- 26 November 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (12) , 7013
Inverted meniscus IOLs reduce image shifts in the periphery compared to biconvex IOLs
Intraocular lenses (IOLs) are routinely used to replace cataractous crystalline lenses. Most current models have a biconvex design that reduces optical quality in the periphery since they are optimized only for central vision. Inverted meniscus IOLs are optimized to achieve similar optical performance to phakic eyes in the peripheral retina. Additionally, biconvex IOLs have been predicted to induce image shifts in the peripheral visual field. The aim of this study was to evaluate whether inverted meniscus IOLs produce a more consistent object-to-image mapping on the retina. For this purpose, retinal images before and after IOL implantation were recorded in subjects implanted with either standard biconvex or inverted meniscus IOLs, and the positions of landmarks were compared. The results showed that radial displacement of retinal landmarks increased with eccentricity in biconvex IOLs, as expected, but tended to have a flatter progression with smaller values in patients implanted with inverted meniscus lenses.
- 26 November 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (12) , 7013
Inverted meniscus IOLs reduce image shifts in the periphery compared to biconvex IOLs
Intraocular lenses (IOLs) are routinely used to replace cataractous crystalline lenses. Most current models have a biconvex design that reduces optical quality in the periphery since they are optimized only for central vision. Inverted meniscus IOLs are optimized to achieve similar optical performance to phakic eyes in the peripheral retina. Additionally, biconvex IOLs have been predicted to induce image shifts in the peripheral visual field. The aim of this study was to evaluate whether inverted meniscus IOLs produce a more consistent object-to-image mapping on the retina. For this purpose, retinal images before and after IOL implantation were recorded in subjects implanted with either standard biconvex or inverted meniscus IOLs, and the positions of landmarks were compared. The results showed that radial displacement of retinal landmarks increased with eccentricity in biconvex IOLs, as expected, but tended to have a flatter progression with smaller values in patients implanted with inverted meniscus lenses.
- 24 October 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (11) , 6486-6498
Ultra-wide-angle peripheral refraction using a laser-scanning instrument
We compared the peripheral refractive measurements of a recently proposed laser-scanning instrument with an established peripheral refractor. Two-dimensional refractive maps were obtained using both instruments for 18 young subjects with differing values of central refraction. The comparison shows a strong correlation between devices in the overlapping measurement area, with the new device extending the range of the explored retinal area to a 100-degree-diameter circular patch, compared to the 60°x35° rectangular area of the older peripheral refractor. Larger refractive maps exhibit trends that cannot be easily predicted from narrower scans. These results demonstrate that the new instrument can be a useful tool for assessing wide-angle peripheral optical data in the human eye.
- 24 October 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (11) , 6486-6498
Ultra-wide-angle peripheral refraction using a laser-scanning instrument
We compared the peripheral refractive measurements of a recently proposed laser-scanning instrument with an established peripheral refractor. Two-dimensional refractive maps were obtained using both instruments for 18 young subjects with differing values of central refraction. The comparison shows a strong correlation between devices in the overlapping measurement area, with the new device extending the range of the explored retinal area to a 100-degree-diameter circular patch, compared to the 60°x35° rectangular area of the older peripheral refractor. Larger refractive maps exhibit trends that cannot be easily predicted from narrower scans. These results demonstrate that the new instrument can be a useful tool for assessing wide-angle peripheral optical data in the human eye.
- 20 May 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (6) , 3848-3858
Contrast sensitivity is resilient to induced fast periodic defocus oscillations
This study investigates the potential effects of periodic defocus oscillations on contrast sensitivity. Sinusoidal fluctuations at 5, 15, and 25 Hz, with defocus peak-to-valley values ranging from 0.15 to 3 D, were induced by means of a focus-tunable lens after calibrating its dynamic behavior. Monocular contrast sensitivity was measured on five young emmetropic subjects. The experimental data shows that contrast sensitivity loss due to defocus fluctuations is low for a wide range of frequencies and amplitudes. Only for the more severe case studied (25 Hz, ± 1.5 D) contrast threshold showed a clear increase in most subjects. Qualitative comparison of the empirical data with a simulation of modulation loss due to time integration of defocused retinal point spread functions, suggests a short integration time by the eye for defocus blur, around or even below a hundredth of a second.
- 20 May 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (6) , 3848-3858
Contrast sensitivity is resilient to induced fast periodic defocus oscillations
This study investigates the potential effects of periodic defocus oscillations on contrast sensitivity. Sinusoidal fluctuations at 5, 15, and 25 Hz, with defocus peak-to-valley values ranging from 0.15 to 3 D, were induced by means of a focus-tunable lens after calibrating its dynamic behavior. Monocular contrast sensitivity was measured on five young emmetropic subjects. The experimental data shows that contrast sensitivity loss due to defocus fluctuations is low for a wide range of frequencies and amplitudes. Only for the more severe case studied (25 Hz, ± 1.5 D) contrast threshold showed a clear increase in most subjects. Qualitative comparison of the empirical data with a simulation of modulation loss due to time integration of defocused retinal point spread functions, suggests a short integration time by the eye for defocus blur, around or even below a hundredth of a second.
- 4 January 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (2) , 608-623
Head-mounted adaptive optics visual simulator
Adaptive optics visual simulation is a powerful tool for vision testing and evaluation. However, the existing instruments either have fixed tabletop configurations or, being wearable, only offer the correction of defocus. This paper proposes a novel head-mounted adaptive optics visual simulator that can measure and modify complex ocular aberrations in real-time. The prototype is composed of two optical modules, one for the objective assessment of aberrations and the second for wavefront modulation, all of which are integrated into a wearable headset. The device incorporates a microdisplay for stimulus generation, a liquid crystal on silicon (LCoS) spatial light modulator for wavefront manipulation, and a Hartmann-Shack wavefront sensor. Miniature optical components and optical path folding structures, together with in-house 3D printed mounts and housing, were adapted to realize the compact size. The system was calibrated by characterizing and compensating the internal aberrations of the visual relay. The performance of the prototype was analyzed by evaluating the measurement and compensation of low-order and higher-order aberrations induced through trial lenses and phase masks in an artificial eye. The defocus curves for a simulated bifocal diffractive lens were evaluated in real eyes. The results show high accuracy while measuring and compensating for the induced defocus, astigmatism, and higher-order aberrations, whereas the MTF analysis shows post-correction resolution of up to 37.5 cycles/degree (VA 1.25). Moreover, the subjective test results show the defocus curves closely matched to a commercial desktop visual simulator.
- 4 January 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (2) , 608-623
Head-mounted adaptive optics visual simulator
Adaptive optics visual simulation is a powerful tool for vision testing and evaluation. However, the existing instruments either have fixed tabletop configurations or, being wearable, only offer the correction of defocus. This paper proposes a novel head-mounted adaptive optics visual simulator that can measure and modify complex ocular aberrations in real-time. The prototype is composed of two optical modules, one for the objective assessment of aberrations and the second for wavefront modulation, all of which are integrated into a wearable headset. The device incorporates a microdisplay for stimulus generation, a liquid crystal on silicon (LCoS) spatial light modulator for wavefront manipulation, and a Hartmann-Shack wavefront sensor. Miniature optical components and optical path folding structures, together with in-house 3D printed mounts and housing, were adapted to realize the compact size. The system was calibrated by characterizing and compensating the internal aberrations of the visual relay. The performance of the prototype was analyzed by evaluating the measurement and compensation of low-order and higher-order aberrations induced through trial lenses and phase masks in an artificial eye. The defocus curves for a simulated bifocal diffractive lens were evaluated in real eyes. The results show high accuracy while measuring and compensating for the induced defocus, astigmatism, and higher-order aberrations, whereas the MTF analysis shows post-correction resolution of up to 37.5 cycles/degree (VA 1.25). Moreover, the subjective test results show the defocus curves closely matched to a commercial desktop visual simulator.
- 21 April 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (5) , 2129-2137
Inverted meniscus intraocular lens as a better optical surrogate of the crystalline lens
Current intraocular lenses (IOLs) are designed to substitute the cataractous crystalline lens, optimizing focus at the fovea. However, the common biconvex design overlooks off-axis performance, leading to a reduced optical quality in the periphery of the retina in pseudophakic patients compared to the normal phakic eye. In this work, we designed an IOL to provide better peripheral optical quality, closer in that respect to the natural lens, using ray-tracing simulations in eye models. The resulting design was a concave-convex inverted meniscus IOL with aspheric surfaces. The curvature radius of the posterior surface was smaller than that of the anterior surface by a factor that depended on the IOL power. The lenses were manufactured and evaluated in a custom-built artificial eye. Images of a point source and of extended targets were directly recorded at various field angles with both standard and the new IOLs. This type of IOL produces superior image quality in the whole visual field, being a better surrogate for the crystalline lens than the commonly used thin biconvex intraocular lenses.
- 21 April 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (5) , 2129-2137
Inverted meniscus intraocular lens as a better optical surrogate of the crystalline lens
Current intraocular lenses (IOLs) are designed to substitute the cataractous crystalline lens, optimizing focus at the fovea. However, the common biconvex design overlooks off-axis performance, leading to a reduced optical quality in the periphery of the retina in pseudophakic patients compared to the normal phakic eye. In this work, we designed an IOL to provide better peripheral optical quality, closer in that respect to the natural lens, using ray-tracing simulations in eye models. The resulting design was a concave-convex inverted meniscus IOL with aspheric surfaces. The curvature radius of the posterior surface was smaller than that of the anterior surface by a factor that depended on the IOL power. The lenses were manufactured and evaluated in a custom-built artificial eye. Images of a point source and of extended targets were directly recorded at various field angles with both standard and the new IOLs. This type of IOL produces superior image quality in the whole visual field, being a better surrogate for the crystalline lens than the commonly used thin biconvex intraocular lenses.
- 21 April 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (5) , 2947-2959
Instrument for fast whole-field peripheral refraction in the human eye
An instrument for fast and objective measurement of the peripheral refraction in the human eye is presented. The apparatus permits the automatic estimation of both defocus and astigmatism at any retinal eccentricity by scanning a near infrared beam. The design includes a Hartmann-Shack wavefront sensor and a steering mirror, which operate in combination with a compounded eyepiece for wide field operation. The basic scanning protocol allows the estimation of refraction in a circular retinal patch of 50 deg diameter (±25 from central fixation) in 3 sec. Combined with additional fixation points, wider retinal fields can be sampled to achieve a whole field. The instrument underwent calibration and testing, and its performance for real eyes was assessed in 11 subjects of varying age and refraction. The results show high repeatability and precision. The instrument provides a new tool for the investigation of peripheral optics in the human eye.
- 21 April 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (5) , 2947-2959
Instrument for fast whole-field peripheral refraction in the human eye
An instrument for fast and objective measurement of the peripheral refraction in the human eye is presented. The apparatus permits the automatic estimation of both defocus and astigmatism at any retinal eccentricity by scanning a near infrared beam. The design includes a Hartmann-Shack wavefront sensor and a steering mirror, which operate in combination with a compounded eyepiece for wide field operation. The basic scanning protocol allows the estimation of refraction in a circular retinal patch of 50 deg diameter (±25 from central fixation) in 3 sec. Combined with additional fixation points, wider retinal fields can be sampled to achieve a whole field. The instrument underwent calibration and testing, and its performance for real eyes was assessed in 11 subjects of varying age and refraction. The results show high repeatability and precision. The instrument provides a new tool for the investigation of peripheral optics in the human eye.
- 7 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11931, 114-117
Phase-only modulation with economic and compact vertical aligned liquid crystal devices
Spatial Light Modulators (SLMs) are widely used in several fields of optics such as adaptive optics or holographic displays. SLMs based on Liquid Crystal (LC) devices allow a dynamic and easy representation of two-dimensional phase maps. However, these devices have two main drawbacks, their elevated cost and large dimensions, which prevents them to be used in applications where compactness and low prices are a must. Here we present a more affordable and compact approach based on vertical aligned LC devices, with characteristics of phase modulation very similar to the widely used parallel aligned LC devices. We study the maximal Field of View for visual correction in a see-through system, where the displayed phase map is used for the correction of visual disorders, from refractive errors, to high order aberrations. To conclude we discuss the potential of using this SLM technology and approach as a key component in smart glasses, paving the way for the development of economic, compact and reliable smart glasses for vision correction, among other applications.
- 7 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11931, 114-117
Phase-only modulation with economic and compact vertical aligned liquid crystal devices
Spatial Light Modulators (SLMs) are widely used in several fields of optics such as adaptive optics or holographic displays. SLMs based on Liquid Crystal (LC) devices allow a dynamic and easy representation of two-dimensional phase maps. However, these devices have two main drawbacks, their elevated cost and large dimensions, which prevents them to be used in applications where compactness and low prices are a must. Here we present a more affordable and compact approach based on vertical aligned LC devices, with characteristics of phase modulation very similar to the widely used parallel aligned LC devices. We study the maximal Field of View for visual correction in a see-through system, where the displayed phase map is used for the correction of visual disorders, from refractive errors, to high order aberrations. To conclude we discuss the potential of using this SLM technology and approach as a key component in smart glasses, paving the way for the development of economic, compact and reliable smart glasses for vision correction, among other applications.
- Open Access
- 1 February 2019
- Published by Elsevier in Future Generation Computer Systems
- Vol. 91, 177-190
GPU-based processing of Hartmann–Shack images for accurate and high-speed ocular wavefront sensing
- 1 February 2019
- Published by Elsevier in Future Generation Computer Systems
- Vol. 91, 177-190
Open AccessGPU-based processing of Hartmann–Shack images for accurate and high-speed ocular wavefront sensing