Gele B. Moloney
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gele B. Moloney has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Albert Lin
Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
3 shared publications - Peter N. Mittwede
Department of Orthopaedic Surgery, University of Mississippi Medical Center, Jackson, USA
3 shared publications - Shaquille Charles
Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
3 shared publications - Rajiv P. Reddy
Department of Orthopedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, USA
2 shared publications - Soheil Sabzevari
UPMC Center for Sports Medicine
2 shared publications - Stephen Ryan Chen
Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
2 shared publications
Latest Publications
- 11 November 2026
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
Local Bone Density of Preoperative CT: A Predictor of Clinically Significant Shortening and Varus Collapse of Well-Reduced Geriatric Intertrochanteric Hip Fractures
Introduction: Intertrochanteric (IT) fractures are the most common geriatric hip fracture, with early fixation failure contributing to high morbidity and mortality. Lower bone density, as measured by Hounsfield units (HU) from CT scans, is predictive of various long bone fractures and fracture fixation failure, although its role in IT fractures is less well described. We aimed to assess the association between local bone density and radiographic outcomes after cephalomedullary nail (CMN) fixation of well-reduced geriatric IT fractures, hypothesizing that lower HU measurements are associated with increased rates of clinically significant shortening and varus collapse. Methods: We retrospectively reviewed patients older than 60 years with low-energy IT fractures treated with a long or short CMN between 2017 and 2024 at a single institution. Fractures with varus malreduction or tip apex distance >25 mm were excluded. Radiographs were assessed postoperatively and at 6 to 24-week follow-up to evaluate for shortening and change in the neck-shaft angle. Hounsfield unit measurements of the proximal femur were obtained from injury CT scans. Two-sample t-tests, simple linear regression, and multivariate logistic regression were used to analyze the relationship between HU and shortening/varus collapse. Results: Among 103 patients (74 women, 29 men; mean age 79.3 ± 9.8 years), the mean local bone density was 193.3 ± 63.4 HU. Patients with clinically significant shortening or varus collapse (n = 38) had significantly lower HU than those without (n = 65) (160.9 vs. 212.3 HU, P < 0.0001). HU was independently associated with shortening/varus collapse (OR 0.98, P < 0.01) and negatively correlated with magnitude of shortening (R 2 = 0.091, P < 0.01). An exploratory threshold of 150 HU significantly predicted shortening. Conclusions: Lower local bone density predicts shortening/varus collapse after CMN fixation of well-reduced geriatric IT fractures, despite optimization of modifiable surgical factors. An exploratory threshold of 150 HU may identify patients at risk of shortening within 24 weeks postoperatively.
- 11 November 2026
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
Local Bone Density of Preoperative CT: A Predictor of Clinically Significant Shortening and Varus Collapse of Well-Reduced Geriatric Intertrochanteric Hip Fractures
Introduction: Intertrochanteric (IT) fractures are the most common geriatric hip fracture, with early fixation failure contributing to high morbidity and mortality. Lower bone density, as measured by Hounsfield units (HU) from CT scans, is predictive of various long bone fractures and fracture fixation failure, although its role in IT fractures is less well described. We aimed to assess the association between local bone density and radiographic outcomes after cephalomedullary nail (CMN) fixation of well-reduced geriatric IT fractures, hypothesizing that lower HU measurements are associated with increased rates of clinically significant shortening and varus collapse. Methods: We retrospectively reviewed patients older than 60 years with low-energy IT fractures treated with a long or short CMN between 2017 and 2024 at a single institution. Fractures with varus malreduction or tip apex distance >25 mm were excluded. Radiographs were assessed postoperatively and at 6 to 24-week follow-up to evaluate for shortening and change in the neck-shaft angle. Hounsfield unit measurements of the proximal femur were obtained from injury CT scans. Two-sample t-tests, simple linear regression, and multivariate logistic regression were used to analyze the relationship between HU and shortening/varus collapse. Results: Among 103 patients (74 women, 29 men; mean age 79.3 ± 9.8 years), the mean local bone density was 193.3 ± 63.4 HU. Patients with clinically significant shortening or varus collapse (n = 38) had significantly lower HU than those without (n = 65) (160.9 vs. 212.3 HU, P < 0.0001). HU was independently associated with shortening/varus collapse (OR 0.98, P < 0.01) and negatively correlated with magnitude of shortening (R 2 = 0.091, P < 0.01). An exploratory threshold of 150 HU significantly predicted shortening. Conclusions: Lower local bone density predicts shortening/varus collapse after CMN fixation of well-reduced geriatric IT fractures, despite optimization of modifiable surgical factors. An exploratory threshold of 150 HU may identify patients at risk of shortening within 24 weeks postoperatively.
- 5 October 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
Mini Fragment T-Plate Fixation for Medial Malleolar Fractures Achieves Comparable Outcomes to Small Fragment Screw Fixation Without Increased Complication Risk
Objectives: To compare clinical outcomes between mini fragment T-plate (MFTP) fixation and traditional small fragment screw (SFS) fixation for medial malleolar ankle fractures, with a focus on complication rates and fracture patterns. Methods: Design: Retrospective comparative cohort study. Setting: Single academic level I trauma center. Patient Selection Criteria: Inclusion criteria: age ≥18 years, OTA/AO type 44 medial malleolar fractures treated with either MFTP (2.0 or 2.4 mm) or SFS (3.5 bicortical or 4.0mm partially threaded) from November 2016 to August 2023, and minimum 6-month radiographic and clinical follow-up. Exclusion criteria: prior ipsilateral ankle surgery, vertical fractures not amendable to screw fixation alone. Intervention: Medial malleolar fracture fixation with one of the aforementioned constructs. Outcome Measures and Comparisons: Primary outcomes compared between MFTP and SFS groups included infection rates, nonunion rates, and reoperation rates. Secondary outcomes included fracture pattern analysis and time to weight bearing. Statistical analysis used chi-square or Fisher's exact test for categorical variables and Student's t-test for continuous variables. Results: From 194 consecutive patients, 141 met inclusion criteria: 68 MFTP (age 47.1±15.9 years, 72% female) and 73 SFS (age 51.0±17.6 years, 64% female). No significant demographic differences were observed between groups with regards to age (p = 0.168), BMI (p = 0.107), sex (p = 0.393), smoking status (p = 0.556), nor presence of diabetes (p = 0.499). Fracture pattern analysis using the Herscovici classification revealed that low transverse fractures (Type B) were treated with MFTP in 94% of cases vs SFS in 6% (p<0.001), while high transverse fractures showed a more balanced treatment distribution (47% versus 53% SFS versus (p=0.865)). Comparing MFTP with SFS fixation, rates of infection (10.3% vs 8.3% respectively, p=0.777), unplanned reoperation rates (7.0% vs 10.0% respectively, p=0.780), and symptomatic hardware requiring reoperation (4.4% vs 2.7% respectively, p=0.672) were comparable. There was no failure of medial malleolar fixation in either group. One nonunion occurred in the MFTP group and one in the SFS group (p=1.000). Presence of an open fracture in the MFTP and SFS groups was significantly different at 4.4% and 19.4% respectively (p=0.009). Conclusion: MFTP demonstrated comparable outcomes and complication rates to SFS fixation for medial malleolar ankle fractures. These findings support MFTP as a viable alternative for medial malleolar fixation where fragment morphology may preclude safe dual-screw placement. Level of Clinical Evidence: 3, Therapeutic Cohort Study.
- 5 October 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
Mini Fragment T-Plate Fixation for Medial Malleolar Fractures Achieves Comparable Outcomes to Small Fragment Screw Fixation Without Increased Complication Risk
Objectives: To compare clinical outcomes between mini fragment T-plate (MFTP) fixation and traditional small fragment screw (SFS) fixation for medial malleolar ankle fractures, with a focus on complication rates and fracture patterns. Methods: Design: Retrospective comparative cohort study. Setting: Single academic level I trauma center. Patient Selection Criteria: Inclusion criteria: age ≥18 years, OTA/AO type 44 medial malleolar fractures treated with either MFTP (2.0 or 2.4 mm) or SFS (3.5 bicortical or 4.0mm partially threaded) from November 2016 to August 2023, and minimum 6-month radiographic and clinical follow-up. Exclusion criteria: prior ipsilateral ankle surgery, vertical fractures not amendable to screw fixation alone. Intervention: Medial malleolar fracture fixation with one of the aforementioned constructs. Outcome Measures and Comparisons: Primary outcomes compared between MFTP and SFS groups included infection rates, nonunion rates, and reoperation rates. Secondary outcomes included fracture pattern analysis and time to weight bearing. Statistical analysis used chi-square or Fisher's exact test for categorical variables and Student's t-test for continuous variables. Results: From 194 consecutive patients, 141 met inclusion criteria: 68 MFTP (age 47.1±15.9 years, 72% female) and 73 SFS (age 51.0±17.6 years, 64% female). No significant demographic differences were observed between groups with regards to age (p = 0.168), BMI (p = 0.107), sex (p = 0.393), smoking status (p = 0.556), nor presence of diabetes (p = 0.499). Fracture pattern analysis using the Herscovici classification revealed that low transverse fractures (Type B) were treated with MFTP in 94% of cases vs SFS in 6% (p<0.001), while high transverse fractures showed a more balanced treatment distribution (47% versus 53% SFS versus (p=0.865)). Comparing MFTP with SFS fixation, rates of infection (10.3% vs 8.3% respectively, p=0.777), unplanned reoperation rates (7.0% vs 10.0% respectively, p=0.780), and symptomatic hardware requiring reoperation (4.4% vs 2.7% respectively, p=0.672) were comparable. There was no failure of medial malleolar fixation in either group. One nonunion occurred in the MFTP group and one in the SFS group (p=1.000). Presence of an open fracture in the MFTP and SFS groups was significantly different at 4.4% and 19.4% respectively (p=0.009). Conclusion: MFTP demonstrated comparable outcomes and complication rates to SFS fixation for medial malleolar ankle fractures. These findings support MFTP as a viable alternative for medial malleolar fixation where fragment morphology may preclude safe dual-screw placement. Level of Clinical Evidence: 3, Therapeutic Cohort Study.
- 1 October 2024
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 14 (4)
Atraumatic Failure of the DePuy Synthes Trochanteric Fixation Nail Advanced Fenestrated Cephalic Lag Screw
Case: Extracapsular proximal femur fractures are a common injury that can be reliably treated with cephalomedullary nailing. We present 2 cases of atraumatic DePuy Synthes Trochanteric Fixation Nail Advanced implant failure through cephalic lag screw fenestrations in the setting of intertrochanteric fracture. Conclusion: Fenestrated lag screws inserted without cement augmentation may be susceptible to fatigue failure. Patients with unstable fracture patterns and other risk factors for delayed healing should undergo close clinical follow-up.
- 1 October 2024
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 14 (4)
Atraumatic Failure of the DePuy Synthes Trochanteric Fixation Nail Advanced Fenestrated Cephalic Lag Screw
Case: Extracapsular proximal femur fractures are a common injury that can be reliably treated with cephalomedullary nailing. We present 2 cases of atraumatic DePuy Synthes Trochanteric Fixation Nail Advanced implant failure through cephalic lag screw fenestrations in the setting of intertrochanteric fracture. Conclusion: Fenestrated lag screws inserted without cement augmentation may be susceptible to fatigue failure. Patients with unstable fracture patterns and other risk factors for delayed healing should undergo close clinical follow-up.
- 16 October 2023
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 105 (23) , 1886-1896
Dual Versus Single Plate Fixation of Displaced Midshaft Clavicle Fractures
Background: Prior studies have highlighted lower rates of reoperation if fixation of a displaced midshaft clavicle fracture is performed with dual plating (DP) compared with single plating (SP). Despite higher initial costs associated with the DP construct, the observed reduction in secondary surgeries compared with the SP construct may make it a more cost-effective treatment option. The objective of this study was to assess the cost-effectiveness of DP compared with SP in patients with operatively indicated displaced midshaft clavicle fractures. Methods: We developed a decision tree to model the occurrence of postoperative complications (acute hardware complications, wound healing issues, deep infection, nonunion, and symptomatic hardware) associated with secondary surgeries. Complication-specific risk estimates were pooled for both plating techniques using the available literature. The time horizon was 2 years, and the analysis was conducted from the health-care payer’s perspective. The costs were estimated using direct medical costs, and the benefits were measured in quality-adjusted life-years (QALYs). We assumed that DP would be $300 more expensive than SP initially. We conducted probabilistic and 1-way sensitivity analyses. Results: The model predicted reoperation in 6% of patients in the DP arm compared with 14% of patients in the SP arm. In the base case analysis, DP increased QALYs by 0.005 and costs by $71 per patient, yielding an incremental cost-effectiveness ratio (ICER) of $13,242 per QALY gained. The sensitivity analysis demonstrated that the cost-effectiveness of DP was driven by the cost of the index surgery, risk of symptomatic hardware, and nonunion complications with SP and DP. At a willingness-to-pay threshold of $100,000 per QALY gained, 95% of simulations suggested that DP was cost-effective compared with SP. Conclusions: When indicated, operative management of displaced midshaft clavicle fractures using DP was found to be cost-effective compared with SP. Despite its higher initial hardware costs, DP fixation appears to offset its added costs with greater health utility via lower rates of reoperation and improved patient quality of life. Level of Evidence: Economic and Decision Analysis Level II. See Instructions for Authors for a complete description of levels of evidence.
- 16 October 2023
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 105 (23) , 1886-1896
Dual Versus Single Plate Fixation of Displaced Midshaft Clavicle Fractures
Background: Prior studies have highlighted lower rates of reoperation if fixation of a displaced midshaft clavicle fracture is performed with dual plating (DP) compared with single plating (SP). Despite higher initial costs associated with the DP construct, the observed reduction in secondary surgeries compared with the SP construct may make it a more cost-effective treatment option. The objective of this study was to assess the cost-effectiveness of DP compared with SP in patients with operatively indicated displaced midshaft clavicle fractures. Methods: We developed a decision tree to model the occurrence of postoperative complications (acute hardware complications, wound healing issues, deep infection, nonunion, and symptomatic hardware) associated with secondary surgeries. Complication-specific risk estimates were pooled for both plating techniques using the available literature. The time horizon was 2 years, and the analysis was conducted from the health-care payer’s perspective. The costs were estimated using direct medical costs, and the benefits were measured in quality-adjusted life-years (QALYs). We assumed that DP would be $300 more expensive than SP initially. We conducted probabilistic and 1-way sensitivity analyses. Results: The model predicted reoperation in 6% of patients in the DP arm compared with 14% of patients in the SP arm. In the base case analysis, DP increased QALYs by 0.005 and costs by $71 per patient, yielding an incremental cost-effectiveness ratio (ICER) of $13,242 per QALY gained. The sensitivity analysis demonstrated that the cost-effectiveness of DP was driven by the cost of the index surgery, risk of symptomatic hardware, and nonunion complications with SP and DP. At a willingness-to-pay threshold of $100,000 per QALY gained, 95% of simulations suggested that DP was cost-effective compared with SP. Conclusions: When indicated, operative management of displaced midshaft clavicle fractures using DP was found to be cost-effective compared with SP. Despite its higher initial hardware costs, DP fixation appears to offset its added costs with greater health utility via lower rates of reoperation and improved patient quality of life. Level of Evidence: Economic and Decision Analysis Level II. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 1 July 2023
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 11 (7_suppl3)
Paper 56: Dual Plate Fixation of Midshaft Clavicle Fractures May Reduce Reoperation Rates Compared to Single Plating with Anterior or Superior Fixation Techniques
Objectives: Dual plate fixation has been proposed as a solution to the high rates of reoperation secondary to operative management of displaced midshaft clavicle fractures. Previous studies have recommended dual plating for patients specifically at higher risk of reoperation. Therefore, the purpose of this study was to compare reoperation rates among patients who underwent single superior, single anterior, and dual plating while adjusting for risk factors including age, smoking status, and high-risk fracture morphology. We hypothesized lower rates of reoperation among patients who underwent dual plate fixation. Methods: This was a retrospective cohort study of all patients who presented with a midshaft clavicle fracture and underwent ORIF between 2007 and 2021 to our trauma/sports divisions. Patient demographics, fracture pattern, plating technique, postoperative complications, date of surgery, reoperation status, date of last follow up, and date of reoperation were documented. We report hazard ratio (HR) estimates using a multivariate multilevel mixed-effects parametric survival model, which accounted for patients with multiple reoperations and adjusted for covariates. Results: A cohort of 395 patients (mean age 38.5±14.4 years, 81.7% male) were identified with average follow-up of 5.5±8.6 months. There were 77 z-type, 157 transverse, and 161 oblique fractures. With regards to plating technique, 152 underwent single superior plating, 149 experienced single anterior plating, and 94 had dual plating. After initial operation, there were 8 total instances of non-union (2.0%), 0 in the dual plating cohort (0%), 4 in the superior plating cohort (2.6%), and 4 in the anterior plating cohort (2.7%) (p=0.35). A total of 28 reoperations took place among 19 patients (4.8%), with 6 patients experiencing multiple reoperations. Single plating with superior placement revealed the highest reoperation rate of 0.26 per person-years, followed by anterior placement with 0.17 per person-years, and finally dual plating with 0.02 per person-years ( Figure 1). Patients who underwent single plating (either anterior or superior placement) revealed a greater rate of reoperation when compared to patients who underwent dual plating (HR: 8.3, p=0.045). Patients who underwent single plating with superior placement had a rate of reoperation ten- times greater than patients who underwent dual plating (HR:10.1, p=0.03). Patients who underwent single plating with anterior placement had a rate of reoperation six-times greater than patients who underwent dual plating (HR: 6.4, p=0.09), although not statistically significant. Conclusions: Dual plate fixation of displaced midshaft clavicle fractures has an eight-fold lower risk of reoperation compared to single plate fixation, while accounting for age, smoking, and high-risk fracture morphology. More specifically, dual plating had lower rates of reoperation than both single plating with anterior and superior placement. When operative management is indicated for a midshaft clavicle fracture, dual plating may be an excellent treatment alternative in patients at high risk for reoperation.
- 1 July 2023
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 11 (7_suppl3)
Open AccessPaper 56: Dual Plate Fixation of Midshaft Clavicle Fractures May Reduce Reoperation Rates Compared to Single Plating with Anterior or Superior Fixation Techniques
Objectives: Dual plate fixation has been proposed as a solution to the high rates of reoperation secondary to operative management of displaced midshaft clavicle fractures. Previous studies have recommended dual plating for patients specifically at higher risk of reoperation. Therefore, the purpose of this study was to compare reoperation rates among patients who underwent single superior, single anterior, and dual plating while adjusting for risk factors including age, smoking status, and high-risk fracture morphology. We hypothesized lower rates of reoperation among patients who underwent dual plate fixation. Methods: This was a retrospective cohort study of all patients who presented with a midshaft clavicle fracture and underwent ORIF between 2007 and 2021 to our trauma/sports divisions. Patient demographics, fracture pattern, plating technique, postoperative complications, date of surgery, reoperation status, date of last follow up, and date of reoperation were documented. We report hazard ratio (HR) estimates using a multivariate multilevel mixed-effects parametric survival model, which accounted for patients with multiple reoperations and adjusted for covariates. Results: A cohort of 395 patients (mean age 38.5±14.4 years, 81.7% male) were identified with average follow-up of 5.5±8.6 months. There were 77 z-type, 157 transverse, and 161 oblique fractures. With regards to plating technique, 152 underwent single superior plating, 149 experienced single anterior plating, and 94 had dual plating. After initial operation, there were 8 total instances of non-union (2.0%), 0 in the dual plating cohort (0%), 4 in the superior plating cohort (2.6%), and 4 in the anterior plating cohort (2.7%) (p=0.35). A total of 28 reoperations took place among 19 patients (4.8%), with 6 patients experiencing multiple reoperations. Single plating with superior placement revealed the highest reoperation rate of 0.26 per person-years, followed by anterior placement with 0.17 per person-years, and finally dual plating with 0.02 per person-years ( Figure 1). Patients who underwent single plating (either anterior or superior placement) revealed a greater rate of reoperation when compared to patients who underwent dual plating (HR: 8.3, p=0.045). Patients who underwent single plating with superior placement had a rate of reoperation ten- times greater than patients who underwent dual plating (HR:10.1, p=0.03). Patients who underwent single plating with anterior placement had a rate of reoperation six-times greater than patients who underwent dual plating (HR: 6.4, p=0.09), although not statistically significant. Conclusions: Dual plate fixation of displaced midshaft clavicle fractures has an eight-fold lower risk of reoperation compared to single plate fixation, while accounting for age, smoking, and high-risk fracture morphology. More specifically, dual plating had lower rates of reoperation than both single plating with anterior and superior placement. When operative management is indicated for a midshaft clavicle fracture, dual plating may be an excellent treatment alternative in patients at high risk for reoperation.
- 4 May 2023
- Published by Elsevier in Operative Techniques in Orthopaedics
- Vol. 33 (2)
Introduction
- 18 August 2022
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 37 (4) , e175-e180
Technical Trick: Supplemental Medial Column Screw Fixation of Distal Femur Fractures Treated With a Laterally Based Locked Plate
Summary: Given known failure rates after lateral plating of distal femur fractures, there is an increasing interest in augmenting fixation to improve outcomes. The addition of medial plates or intramedullary nails have been described with promising results, decreasing nonunion and varus collapse rates. However, the use of dual implants increases implant costs, adds surgical complexity, and requires a second surgical approach that may increase morbidity. A supplemental, percutaneously placed, medial column screw may provide a less invasive means of improving stability and achieving fracture union compared with lateral plating alone.
- 18 August 2022
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 37 (4) , e175-e180
Technical Trick: Supplemental Medial Column Screw Fixation of Distal Femur Fractures Treated With a Laterally Based Locked Plate
Summary: Given known failure rates after lateral plating of distal femur fractures, there is an increasing interest in augmenting fixation to improve outcomes. The addition of medial plates or intramedullary nails have been described with promising results, decreasing nonunion and varus collapse rates. However, the use of dual implants increases implant costs, adds surgical complexity, and requires a second surgical approach that may increase morbidity. A supplemental, percutaneously placed, medial column screw may provide a less invasive means of improving stability and achieving fracture union compared with lateral plating alone.
- 25 April 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 31 (10) , e498-e506
Risk factors for complications and reoperation following operative management of displaced midshaft clavicle fractures
- 25 April 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 31 (10) , e498-e506
Risk factors for complications and reoperation following operative management of displaced midshaft clavicle fractures
- Open Access
- 1 October 2021
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 5 (10)
Subcuticular Barbed Suture and Skin Glue Wound Closure Decreases Reoperation and Length of Stay in Geriatric Hip Fractures When Compared With Staples
Introduction: Patients with geriatric hip fracture are notoriously frail and at risk for complications. Persistent postoperative wound drainage can lead to prolonged hospital stay, increased risk for infection, and need for revision surgery. The purpose of this study was to determine the effect of wound closure technique, barbed monofilament subcuticular suture and skin glue versus staples on rates of intervention for wound drainage and length of hospital stay after geriatric hip fracture fixation. Methods: A retrospective review of isolated hip fractures in patients older than 60 years at a single institution over a 3-year period was done. Hip fractures included femoral neck, intertrochanteric, and subtrochanteric femur fractures treated with internal fixation or arthroplasty. Skin closure technique, at the discretion of the operating surgeon, included either barbed subcuticular monofilament suture and skin glue or staples. Charts and radiographs were reviewed to determine patient characteristics, Charlson Comorbidity Index, type of wound closure, length of stay, and interventions for persistent wound drainage. Results: There were 175 patients in the barbed suture and skin glue group and 211 patients in the staples group. The barbed suture group had an average postsurgical length of stay of 5.0 days which was significantly lower than the staples group (7.0 days, P < 0.00001). In the staples group, 17 patients (8%) required incisional negative pressure wound therapy due to wound drainage with five patients (2.4%) returning to the operating room secondary to persistent wound drainage. No patients were observed in the barbed suture group that required intervention for wound drainage. Discussion: Barbed suture and skin glue closure is associated with markedly shorter hospital stay and fewer interventions for wound drainage when compared with staples after surgical treatment of geriatric hip fractures.
- 1 October 2021
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 5 (10)
Open AccessSubcuticular Barbed Suture and Skin Glue Wound Closure Decreases Reoperation and Length of Stay in Geriatric Hip Fractures When Compared With Staples
Introduction: Patients with geriatric hip fracture are notoriously frail and at risk for complications. Persistent postoperative wound drainage can lead to prolonged hospital stay, increased risk for infection, and need for revision surgery. The purpose of this study was to determine the effect of wound closure technique, barbed monofilament subcuticular suture and skin glue versus staples on rates of intervention for wound drainage and length of hospital stay after geriatric hip fracture fixation. Methods: A retrospective review of isolated hip fractures in patients older than 60 years at a single institution over a 3-year period was done. Hip fractures included femoral neck, intertrochanteric, and subtrochanteric femur fractures treated with internal fixation or arthroplasty. Skin closure technique, at the discretion of the operating surgeon, included either barbed subcuticular monofilament suture and skin glue or staples. Charts and radiographs were reviewed to determine patient characteristics, Charlson Comorbidity Index, type of wound closure, length of stay, and interventions for persistent wound drainage. Results: There were 175 patients in the barbed suture and skin glue group and 211 patients in the staples group. The barbed suture group had an average postsurgical length of stay of 5.0 days which was significantly lower than the staples group (7.0 days, P < 0.00001). In the staples group, 17 patients (8%) required incisional negative pressure wound therapy due to wound drainage with five patients (2.4%) returning to the operating room secondary to persistent wound drainage. No patients were observed in the barbed suture group that required intervention for wound drainage. Discussion: Barbed suture and skin glue closure is associated with markedly shorter hospital stay and fewer interventions for wound drainage when compared with staples after surgical treatment of geriatric hip fractures.