Vivek Kumar Sahu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vivek Kumar Sahu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Nilesh Prakash Gurao
Indian Institute of Technology Kanpur
5 shared publications - Manasij Yadava
Indian Inst Technol Kanpur, Dept Mat Sci & Engn, Kanpur 208016, India
3 shared publications - Yogendra Joshi
George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
2 shared publications Abdul Khadar Syed
1 shared publication- Alec E. Davis
Department of Materials, The University of Manchester, Manchester, UK
1 shared publication - Ali Shakouri
Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, USA
1 shared publication
Latest Publications
- Open Access
- 11 April 2025
- Published by Elsevier in Additive Manufacturing
- Vol. 105
Microstructure tailoring of a wire-arc DED processed Ti6242 alloy for high damage tolerance performance
- 11 April 2025
- Published by Elsevier in Additive Manufacturing
- Vol. 105
Open AccessMicrostructure tailoring of a wire-arc DED processed Ti6242 alloy for high damage tolerance performance
- 30 April 2024
- Published by Elsevier in International Journal of Plasticity
- Vol. 177, 103985
Micro-mechanisms of anisotropic deformation in the presence of notch in commercially pure Titanium: An in-situ study with CPFEM simulations
- 30 April 2024
- Published by Elsevier in International Journal of Plasticity
- Vol. 177, 103985
Micro-mechanisms of anisotropic deformation in the presence of notch in commercially pure Titanium: An in-situ study with CPFEM simulations
- 11 July 2023
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 881, 145434
Elucidating the extreme anisotropy in the J-integral value of commercially pure titanium
- 11 July 2023
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 881, 145434
Elucidating the extreme anisotropy in the J-integral value of commercially pure titanium
- 1 January 2022
- Published by Springer Nature in Journal of the Indian Institute of Science
- Vol. 102 (1) , 173-210
In Situ Experiments: Paving Ways for Rapid Development of Structural Metallic Materials for a Sustainable Future
- 1 January 2022
- Published by Springer Nature in Journal of the Indian Institute of Science
- Vol. 102 (1) , 173-210
In Situ Experiments: Paving Ways for Rapid Development of Structural Metallic Materials for a Sustainable Future
- Open Access
- 12 October 2020
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 321, 04005
Normal and dwell fatigue behavior of a near-alpha titanium alloy - IMI 834
Dwell sensitivity of titanium alloys at ambient temperature (~250 C) is a well-known phenomenon, although the question about the exact micromechanical reasons responsible for this still remains open. In this work, the normal and dwell fatigue response of a near-alpha titanium alloy, IMI 834, is studied. Samples with three different microstructures, namely, fully lamellar, fully equiaxed and bimodal, are evaluated for their dwell fatigue behaviors. A reduction in fatigue life by at least an order of magnitude is seen in all the three microstructures. Large plastic strain accumulation (almost equal to the monotonic ductility) was observed during the dwell fatigue loading condition and this is held responsible for this large debit in fatigue life. The normal fatigue lives decreased in the order, bimodal > fully equiaxed > fully lamellar, while the dwell fatigue lives decreased in the order, fully equiaxed > fully lamellar > bimodal. Bimodal microstructure showed a dwell fatigue debit of 17, while fully lamellar and fully equiaxed showed a debit of 9 and 10, respectively.
- 12 October 2020
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 321, 04005
Open AccessNormal and dwell fatigue behavior of a near-alpha titanium alloy - IMI 834
Dwell sensitivity of titanium alloys at ambient temperature (~250 C) is a well-known phenomenon, although the question about the exact micromechanical reasons responsible for this still remains open. In this work, the normal and dwell fatigue response of a near-alpha titanium alloy, IMI 834, is studied. Samples with three different microstructures, namely, fully lamellar, fully equiaxed and bimodal, are evaluated for their dwell fatigue behaviors. A reduction in fatigue life by at least an order of magnitude is seen in all the three microstructures. Large plastic strain accumulation (almost equal to the monotonic ductility) was observed during the dwell fatigue loading condition and this is held responsible for this large debit in fatigue life. The normal fatigue lives decreased in the order, bimodal > fully equiaxed > fully lamellar, while the dwell fatigue lives decreased in the order, fully equiaxed > fully lamellar > bimodal. Bimodal microstructure showed a dwell fatigue debit of 17, while fully lamellar and fully equiaxed showed a debit of 9 and 10, respectively.
- 8 September 2020
- Published by Springer Nature in Metallurgical and Materials Transactions A
- Vol. 51 (11) , 5848-5860
Effect of Initial Texture on the Evolution of Microstructure and Texture During Rolling of Commercially Pure Titanium at Room and Cryogenic Temperature
- 8 September 2020
- Published by Springer Nature in Metallurgical and Materials Transactions A
- Vol. 51 (11) , 5848-5860
Effect of Initial Texture on the Evolution of Microstructure and Texture During Rolling of Commercially Pure Titanium at Room and Cryogenic Temperature
- 1 March 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10652221,p. 130-134
Energy efficient liquid-thermoelectric hybrid cooling for hot-spot removal
We report a study on a liquid-thermoelectric hybrid cooling that allows a multiple larger heat flux (>;600 W/m 2 ) hotspots on a chip that is never achievable with a reasonable pump power for a microchannel with single phase liquid cooling. Thermoelectric effect is realized in this study by embedding to the silicon chip in superlattice microcooler which has been studied in our previous work. We went through an analytic modeling including spreading resistance through the substrate and modeled the fluid dynamic characteristic of microchannel so that we were able to find the pump power and cooling power of superlattice cooler. We also verified the performance with 3D numerical simulation. The results show that the hybrid system allows much higher heat flux for a hotspot while superlattice cooler locates correctly. As an example, if we have a ZT=0.5 material, a 500μm × 500μm hotspot can be maintained at 85°C (ambient 35°C) with around 850W/cm 2 while a simple liquid cooling reaches 620W/cm 2 for the same 12W/cm 2 of overall cooling power.
- 1 March 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10652221,p. 130-134
Energy efficient liquid-thermoelectric hybrid cooling for hot-spot removal
We report a study on a liquid-thermoelectric hybrid cooling that allows a multiple larger heat flux (>;600 W/m 2 ) hotspots on a chip that is never achievable with a reasonable pump power for a microchannel with single phase liquid cooling. Thermoelectric effect is realized in this study by embedding to the silicon chip in superlattice microcooler which has been studied in our previous work. We went through an analytic modeling including spreading resistance through the substrate and modeled the fluid dynamic characteristic of microchannel so that we were able to find the pump power and cooling power of superlattice cooler. We also verified the performance with 3D numerical simulation. The results show that the hybrid system allows much higher heat flux for a hotspot while superlattice cooler locates correctly. As an example, if we have a ZT=0.5 material, a 500μm × 500μm hotspot can be maintained at 85°C (ambient 35°C) with around 850W/cm 2 while a simple liquid cooling reaches 620W/cm 2 for the same 12W/cm 2 of overall cooling power.
- 1 January 2011
- Published by ASME International
- p. T30026-T30026-6
Infrared Imaging Microscope as an Effective Tool for Measuring Thermal Resistance of Emerging Interface Materials
The reduction of interfacial resistance continues to be a significant challenge in thermal management of semiconductor and other microscale devices. Current state-of-the-art thermal interface materials (TIMs) have resistances in the range of 5–10 mm2·K/W. At these values, particularly for the emerging highly nonhomogeneous materials, standard measurement techniques often fail to provide accurate results. This paper describes the use of infrared microscopy for measuring the total thermal resistance across multiple interfaces. The method is capable of measuring samples of wide ranging resistances with thicknesses ranging from 50–250 μm. This steady-state technique has several advantages over other methods, including the elimination of the need for intrusive temperature monitoring devices like thermocouples at the area of interest and the need for a priori knowledge of the specific heat and density of the materials of interest, as in the transient techniques for determining thermal resistances. Results for three different commercially available TIM and uncertainty analysis are presented.
- 1 January 2011
- Published by ASME International
- p. T30026-T30026-6
Infrared Imaging Microscope as an Effective Tool for Measuring Thermal Resistance of Emerging Interface Materials
The reduction of interfacial resistance continues to be a significant challenge in thermal management of semiconductor and other microscale devices. Current state-of-the-art thermal interface materials (TIMs) have resistances in the range of 5–10 mm2·K/W. At these values, particularly for the emerging highly nonhomogeneous materials, standard measurement techniques often fail to provide accurate results. This paper describes the use of infrared microscopy for measuring the total thermal resistance across multiple interfaces. The method is capable of measuring samples of wide ranging resistances with thicknesses ranging from 50–250 μm. This steady-state technique has several advantages over other methods, including the elimination of the need for intrusive temperature monitoring devices like thermocouples at the area of interest and the need for a priori knowledge of the specific heat and density of the materials of interest, as in the transient techniques for determining thermal resistances. Results for three different commercially available TIM and uncertainty analysis are presented.