Yi Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yi Guo has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Shuang Liu
College of Engineering Science and Technology, Shanghai Ocean University, Shanghai, China
2 shared publications Chao Lyu
College of Engineering Science and Technology, Shanghai Ocean University, Shanghai, China
1 shared publication- Chao Lyu
College of Economics & Management, Shanghai Ocean University, Shanghai, 201306, China
1 shared publication He-Xu Zhang
College of Engineering Science and Technology, Shanghai Ocean University, Shanghai, China
1 shared publication- Shuang Wang
College of Engineering Science and Technology, Shanghai Ocean University, Shanghai 201306, China
1 shared publication
Latest Publications
- Open Access
- 28 May 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-17
Fishing capacity evaluation of fishing vessel based on cloud model
In the evaluation problem of fishing vessel fishing capacity, the imperfect evaluation index system and the methods of evaluation indexes are mostly artificial qualitative evaluation methods, which lead to strong subjectivity and fuzziness as well as low accuracy of evaluation results. Therefore, this study introduces cloud model theory on the basis of improving the evaluation index system, converts the artificial qualitative evaluation results into the digital characteristics of clouds, realizes the mutual transformation of qualitative evaluation and quantitative evaluation, and improves the accuracy of evaluation results. Taking the trawler as an example, the cloud model method is used to evaluate the fishing capacity, and the result obtained is (77.1408, 1.6897, 0.0), the result obtained by the fuzzy comprehensive evaluation method is 76.664785, and the result obtained by the cloud center of gravity evaluation method is 0.7919. Compared with the other two methods, the cloud model method uses three numerical characteristics to describe the results, and combining the different numerical characteristics meanings, the evaluation results can be judged to be accurate, and the influence of ambiguity on the results is greatly reduced. Meanwhile, the evaluation results can be presented in the form of pictures, and the results are more intuitive; in addition, the cloud model of the evaluation results is compared with the standard cloud model for similarity, which improves the credibility and authenticity of the results.
- 28 May 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-17
Open AccessFishing capacity evaluation of fishing vessel based on cloud model
In the evaluation problem of fishing vessel fishing capacity, the imperfect evaluation index system and the methods of evaluation indexes are mostly artificial qualitative evaluation methods, which lead to strong subjectivity and fuzziness as well as low accuracy of evaluation results. Therefore, this study introduces cloud model theory on the basis of improving the evaluation index system, converts the artificial qualitative evaluation results into the digital characteristics of clouds, realizes the mutual transformation of qualitative evaluation and quantitative evaluation, and improves the accuracy of evaluation results. Taking the trawler as an example, the cloud model method is used to evaluate the fishing capacity, and the result obtained is (77.1408, 1.6897, 0.0), the result obtained by the fuzzy comprehensive evaluation method is 76.664785, and the result obtained by the cloud center of gravity evaluation method is 0.7919. Compared with the other two methods, the cloud model method uses three numerical characteristics to describe the results, and combining the different numerical characteristics meanings, the evaluation results can be judged to be accurate, and the influence of ambiguity on the results is greatly reduced. Meanwhile, the evaluation results can be presented in the form of pictures, and the results are more intuitive; in addition, the cloud model of the evaluation results is compared with the standard cloud model for similarity, which improves the credibility and authenticity of the results.
- Open Access
- 28 April 2022
- Published by MDPI AG in Electronics
- Vol. 11 (9) , 1419
Method for Measuring Interface Pressure of High-Voltage Cables
In high-voltage cables, because of the close fit of their internal structures, interface pressure is generated between conductor and insulator, which affects the performance of the cable. Studies on the calculation and testing of the interfacial pressure of cable conductors are scarce because of the lack of a unified formula and the difficulty of direct measurement. As such, in this study, we devised two methods for calculating and measuring the interface pressure of cable conductors. In the first, we used two physical experimental methods. We used the friction between cable components to perform the calculation and create an experimental method for determining cable conductor interface pressure; on the basis of the equation of the pressure inside and outside a thick-walled cylinder using elasticity mechanics, we calculated the interface pressure on the basis of the measurement of the strain state of the inner and outer diameters of each layer of the cable under different assembly and stripping conditions. We verified the effectiveness of the methods through physical tests and simulations using a YJLW03 1 × 1200 high-voltage cable. Then, we used simulation software ANSYS and SolidWorks to calculate the interface pressure. With different simulation settings, we obtained results regarding interface pressure. Lastly, these simulated values were individually compared with two physical tests, and the error was calculated. Results obtained in the ANSYS environment showed that interface pressure values determined by the geometric interference normal stress, geometric interference pressure, contact interference normal stress, and contact interference pressure methods were 39.75, 36.84, 5.76, and 36.57 MPa, respectively. In SolidWorks software, we used the contact-stress and X-axis normal stress methods. Results were all 37.36 MPa. Then, simulation results and experimental results were compared, and error was calculated. The comparison showed that the X-axis orthogonal stress method was the most accurate. Errors between the X-axis orthogonal stress method and the two physical experiments were 1.5% and 0.48%. Through the above simulation and physical experiments, we determined the interface pressure between conductors and insulators in a high-voltage power cable. We obtained the cable interface pressure value through two kinds of physical experiments, and these two methods were clearly reliable. Simulation experiments showed that using SolidWorks software to simulate this problem obtained better results. Research results provide technical support and reference for the calculation and measurement of cable interface pressure and the optimization of cable performance.
- 28 April 2022
- Published by MDPI AG in Electronics
- Vol. 11 (9) , 1419
Open AccessMethod for Measuring Interface Pressure of High-Voltage Cables
In high-voltage cables, because of the close fit of their internal structures, interface pressure is generated between conductor and insulator, which affects the performance of the cable. Studies on the calculation and testing of the interfacial pressure of cable conductors are scarce because of the lack of a unified formula and the difficulty of direct measurement. As such, in this study, we devised two methods for calculating and measuring the interface pressure of cable conductors. In the first, we used two physical experimental methods. We used the friction between cable components to perform the calculation and create an experimental method for determining cable conductor interface pressure; on the basis of the equation of the pressure inside and outside a thick-walled cylinder using elasticity mechanics, we calculated the interface pressure on the basis of the measurement of the strain state of the inner and outer diameters of each layer of the cable under different assembly and stripping conditions. We verified the effectiveness of the methods through physical tests and simulations using a YJLW03 1 × 1200 high-voltage cable. Then, we used simulation software ANSYS and SolidWorks to calculate the interface pressure. With different simulation settings, we obtained results regarding interface pressure. Lastly, these simulated values were individually compared with two physical tests, and the error was calculated. Results obtained in the ANSYS environment showed that interface pressure values determined by the geometric interference normal stress, geometric interference pressure, contact interference normal stress, and contact interference pressure methods were 39.75, 36.84, 5.76, and 36.57 MPa, respectively. In SolidWorks software, we used the contact-stress and X-axis normal stress methods. Results were all 37.36 MPa. Then, simulation results and experimental results were compared, and error was calculated. The comparison showed that the X-axis orthogonal stress method was the most accurate. Errors between the X-axis orthogonal stress method and the two physical experiments were 1.5% and 0.48%. Through the above simulation and physical experiments, we determined the interface pressure between conductors and insulators in a high-voltage power cable. We obtained the cable interface pressure value through two kinds of physical experiments, and these two methods were clearly reliable. Simulation experiments showed that using SolidWorks software to simulate this problem obtained better results. Research results provide technical support and reference for the calculation and measurement of cable interface pressure and the optimization of cable performance.