Shijie Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shijie Zheng has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Guoying Feng
Sichuan University
3 shared publications - Hangyu Zhang
Institute of Laser & Micro/Nano Engineering, College of Electronics & Information Engineering, Sichuan University, Chengdu 610065, China
2 shared publications - Chen Ding
West China Hospital, Sichuan University, Chengdu 610041, China
1 shared publication - Junlong Yang
College of Polymer Science and Engineering State Key Laboratory of Advanced Polymer Materials Sichuan University Chengdu China
1 shared publication - Lei Chen
Department of Neurology, West China Hospital, Sichuan University, Chengdu, China
1 shared publication - Lei Lei
State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Frontier Innovation Center for Dental Medicine Plus, West China Hospital of Stomatology, Sichuan University, Chengdu, China
1 shared publication
Latest Publications
- Open Access
A Novel Closed-Loop Control to Solve Light Source Power Fluctuations in the Fiber-Optic Gyroscope
The performance of a gyroscope is directly affected by the fluctuations in the light source power (LSP) in an interferometric fiber-optic gyroscope (IFOG). Therefore, it is important to compensate for fluctuations in the LSP. When the feedback phase generated by the step wave completely cancels the Sagnac phase in real-time, the error signal of the gyroscope is linearly related to the differential signal of the LSP, otherwise, the error signal of the gyroscope is uncertain. Herein, we present two compensation methods to compensate for the error of the gyroscope when the error is uncertain, which are double period modulation (DPM) and triple period modulation (TPM). Compared with the TPM, DPM has better performance, but it increases the requirements for the circuit. TPM has lower requirements for the circuit and is more suitable for small fiber- coil applications. The experimental results show that, when the frequency of the LSP fluctuation is relatively low (1 kHz and 2 kHz), DPM and TPM do not differ significantly in terms of performance; both of them can achieve an improvement of about 95% in bias stability. When the frequency of the LSP fluctuation is relatively high (4 kHz, 8 kHz and 16 kHz), DPM and TPM can achieve about 95% and 88% improvement in bias stability, respectively.
Open AccessA Novel Closed-Loop Control to Solve Light Source Power Fluctuations in the Fiber-Optic Gyroscope
The performance of a gyroscope is directly affected by the fluctuations in the light source power (LSP) in an interferometric fiber-optic gyroscope (IFOG). Therefore, it is important to compensate for fluctuations in the LSP. When the feedback phase generated by the step wave completely cancels the Sagnac phase in real-time, the error signal of the gyroscope is linearly related to the differential signal of the LSP, otherwise, the error signal of the gyroscope is uncertain. Herein, we present two compensation methods to compensate for the error of the gyroscope when the error is uncertain, which are double period modulation (DPM) and triple period modulation (TPM). Compared with the TPM, DPM has better performance, but it increases the requirements for the circuit. TPM has lower requirements for the circuit and is more suitable for small fiber- coil applications. The experimental results show that, when the frequency of the LSP fluctuation is relatively low (1 kHz and 2 kHz), DPM and TPM do not differ significantly in terms of performance; both of them can achieve an improvement of about 95% in bias stability. When the frequency of the LSP fluctuation is relatively high (4 kHz, 8 kHz and 16 kHz), DPM and TPM can achieve about 95% and 88% improvement in bias stability, respectively.
- Open Access
Real-Time Compensation for SLD Light-Power Fluctuation in an Interferometric Fiber-Optic Gyroscope
An interferometric fiber-optic gyroscope (IFOG) demodulates a rotation signal via interferometric light intensity. However, the working environments of IFOGs typically involve great uncertainty. Fluctuations in temperature, air pressure, electromagnetic field, and the power system all cause the power of the superluminescent diode (SLD) light source to fluctuate as well. In this invited paper, we studied the effects of SLD power fluctuation on the dynamic and static performance characteristics of a gyro system through the use of a light-power feedback loop. Fluctuations of 0.5 mA, 1 mA, and 5 mA in the SLD source entering the IFOG caused zero-bias stability to be 69, 135, and 679 times worse. We established an effective method to monitor power fluctuations of SLD light sources and to compensate for their effects without increasing hardware complexity or system cost. In brief, we established a real-time power-sensing and -compensating system. Experimental results showed that for every 0.1 mA increase in the fluctuation amplitude of the driving current, the zero-bias stability became 4 to 7 times worse, which could be reduced about 95% through the use of SLD power compensation.
Open AccessReal-Time Compensation for SLD Light-Power Fluctuation in an Interferometric Fiber-Optic Gyroscope
An interferometric fiber-optic gyroscope (IFOG) demodulates a rotation signal via interferometric light intensity. However, the working environments of IFOGs typically involve great uncertainty. Fluctuations in temperature, air pressure, electromagnetic field, and the power system all cause the power of the superluminescent diode (SLD) light source to fluctuate as well. In this invited paper, we studied the effects of SLD power fluctuation on the dynamic and static performance characteristics of a gyro system through the use of a light-power feedback loop. Fluctuations of 0.5 mA, 1 mA, and 5 mA in the SLD source entering the IFOG caused zero-bias stability to be 69, 135, and 679 times worse. We established an effective method to monitor power fluctuations of SLD light sources and to compensate for their effects without increasing hardware complexity or system cost. In brief, we established a real-time power-sensing and -compensating system. Experimental results showed that for every 0.1 mA increase in the fluctuation amplitude of the driving current, the zero-bias stability became 4 to 7 times worse, which could be reduced about 95% through the use of SLD power compensation.
- Open Access
- 28 April 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (5) , 694
Flexible Wearable Pressure Sensor Based on Collagen Fiber Material
Flexible wearable pressure sensors play a pivotal role in healthcare monitoring, disease prevention, and humanmachine interactions. However, their narrow sensing ranges, low detection sensitivities, slow responses, and complex preparation processes restrict their application in smart wearable devices. Herein, a capacitive pressure sensor with high sensitivity and flexibility that uses an ionic collagen fiber material as the dielectric layer is proposed. The sensor exhibits a high sensitivity (5.24 kPa−1), fast response time (40 ms), long-term stability, and excellent repeatability over 3000 cycles. Because the sensor is resizable, flexible, and has a simple preparation process, it can be flexibly attached to clothes and the human body for wearable monitoring. Furthermore, the practicality of the sensor is proven by attaching it to different measurement positions on the human body to monitor the activity signal.
- 28 April 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (5) , 694
Open AccessFlexible Wearable Pressure Sensor Based on Collagen Fiber Material
Flexible wearable pressure sensors play a pivotal role in healthcare monitoring, disease prevention, and humanmachine interactions. However, their narrow sensing ranges, low detection sensitivities, slow responses, and complex preparation processes restrict their application in smart wearable devices. Herein, a capacitive pressure sensor with high sensitivity and flexibility that uses an ionic collagen fiber material as the dielectric layer is proposed. The sensor exhibits a high sensitivity (5.24 kPa−1), fast response time (40 ms), long-term stability, and excellent repeatability over 3000 cycles. Because the sensor is resizable, flexible, and has a simple preparation process, it can be flexibly attached to clothes and the human body for wearable monitoring. Furthermore, the practicality of the sensor is proven by attaching it to different measurement positions on the human body to monitor the activity signal.