Han Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Han Lin has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Hideyuki Mitomo
Research Institute for Electronic Science Hokkaido University Sapporo Japan
3 shared publications - Kuniharu Ijiro
Research Institute for Electronic Science, Hokkaido University, Sapporo, Japan
2 shared publications - Zhiyong Guo
State Key Laboratory for Quality and Safety of Agro-Products, School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, PR China
2 shared publications - Ce Wang
Jilin University
1 shared publication Changhao Qian
Co-Innovation Centre of Efficient Processing and Utilization of Forest Resources, Nanjing Forestry University, Nanjing 210037, China
1 shared publication- Chen Chen
Co-Innovation Centre of Efficient Processing and Utilization of Forest Resources, Nanjing Forestry University, Nanjing 210037, China
1 shared publication
Latest Publications
- Open Access
- 21 October 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (44) , 24616-24624
Highly Sensitive and Quantitative Detection of microRNA-21 in Cells Using Bipedal DNA Walker-Based Ratiometric Fluorescent Sensor
Accurate detection of low-abundance microRNA (miRNA) as tumor biomarkers in body fluids and cells is critical due to its strong association with tumor initiation, progression, invasion, and metastasis. DNA walkers enable signal amplification through cyclic enzymatic reactions, offering powerful strategies for the highly sensitive detection of low-abundance miRNAs. However, fluctuations in the cellular microenvironment─such as variations in ion concentration, enzyme activity, temperature, and pH across subcellular compartments─can disrupt amplification efficiency and compromise detection accuracy. To address this challenge, we developed a symmetric bipedal DNA walker design in which one "leg" generates a detection signal while the other "reference leg" synchronously amplifies a dynamic (environment-responsive) internal reference signal. Unlike traditional static internal reference strategies, this design introduces a real-time, synchronized internal reference during the DNA walking process to correct for system errors. When combined with ratiometric fluorescence-based error compensation, this approach effectively eliminates signal variation caused by nanoparticle loading, strand assembly, and environmental fluctuations, thereby improving the detection precision and reproducibility. The system, constructed on gold nanoparticles using an inverted hairpin scaffold, demonstrated robust and consistent performance under varied experimental conditions. Confocal ratiometric fluorescence imaging enabled the high-contrast quantification of intracellular miRNA-21 (miR-21) levels across different cell lines. Moreover, spatially resolved fluorescence signals revealed heterogeneous miR-21 distribution within individual cells, providing valuable insights into its subcellular localization and functional relevance. This strategy represents a reliable platform for accurate miRNA quantification even in complex biological environments.
- 21 October 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (44) , 24616-24624
Open AccessHighly Sensitive and Quantitative Detection of microRNA-21 in Cells Using Bipedal DNA Walker-Based Ratiometric Fluorescent Sensor
Accurate detection of low-abundance microRNA (miRNA) as tumor biomarkers in body fluids and cells is critical due to its strong association with tumor initiation, progression, invasion, and metastasis. DNA walkers enable signal amplification through cyclic enzymatic reactions, offering powerful strategies for the highly sensitive detection of low-abundance miRNAs. However, fluctuations in the cellular microenvironment─such as variations in ion concentration, enzyme activity, temperature, and pH across subcellular compartments─can disrupt amplification efficiency and compromise detection accuracy. To address this challenge, we developed a symmetric bipedal DNA walker design in which one "leg" generates a detection signal while the other "reference leg" synchronously amplifies a dynamic (environment-responsive) internal reference signal. Unlike traditional static internal reference strategies, this design introduces a real-time, synchronized internal reference during the DNA walking process to correct for system errors. When combined with ratiometric fluorescence-based error compensation, this approach effectively eliminates signal variation caused by nanoparticle loading, strand assembly, and environmental fluctuations, thereby improving the detection precision and reproducibility. The system, constructed on gold nanoparticles using an inverted hairpin scaffold, demonstrated robust and consistent performance under varied experimental conditions. Confocal ratiometric fluorescence imaging enabled the high-contrast quantification of intracellular miRNA-21 (miR-21) levels across different cell lines. Moreover, spatially resolved fluorescence signals revealed heterogeneous miR-21 distribution within individual cells, providing valuable insights into its subcellular localization and functional relevance. This strategy represents a reliable platform for accurate miRNA quantification even in complex biological environments.
- 3 February 2025
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 37 (3) , 1221-1230
Chiral Shape Engineering Combined with Bimetallic Nanostructures for High-Performance Plasmonic Sulfide Sensors
- 3 February 2025
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 37 (3) , 1221-1230
Chiral Shape Engineering Combined with Bimetallic Nanostructures for High-Performance Plasmonic Sulfide Sensors
- 10 May 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 11 (22) , 7441-7450
Boosting PEDOT energy storage with a redox anthraquinone dopant for a flexible hydrogel supercapacitor at sub-zero temperatures
Although electrically conductive hydrogels based on conductive polymers hold promise for flexible and high-performance supercapacitors, it is still a challenge for such devices to maintain high capacitance with temperature change, especially under subzero conditions. Herein, conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT) decorated with redox-active anthraquinone-2-sulfonic acid sodium (AQS) on the surface is homogeneously dispersed in a poly(acrylic acid) (PAA) hydrogel, which reinforces the conductivity and the stretchability of the obtained AQS–PEDOT/PAA hydrogel electrode. Particularly, with the containing of the H2SO4 + KCl electrolyte, the hydrogel is temperature tolerant and endows the assembled supercapacitor with a wide working temperature of −30 to 90 °C. Due to the extra energy storage contribution of AQS, the device exhibits a high capacitance of 466.5 mF cm−2, a maximum energy density of 41.47 μW h cm−2 and an exceptional cyclic stability of 90% retention after 5000 cycles. Very interestingly, the AQS–PEDOT/PAA electrode shows a remarkable solar-thermal conversion, which significantly boosts the electrochemical performance of the device under subzero conditions. Under solar illumination, the device shows a capacitance enhancement of 39.6% at −30 °C as compared with the device in the dark. This work provides an innovative strategy to spur the sluggish performance of conductive polymer-based hydrogel supercapacitors for practical applications.
- 10 May 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 11 (22) , 7441-7450
Boosting PEDOT energy storage with a redox anthraquinone dopant for a flexible hydrogel supercapacitor at sub-zero temperatures
Although electrically conductive hydrogels based on conductive polymers hold promise for flexible and high-performance supercapacitors, it is still a challenge for such devices to maintain high capacitance with temperature change, especially under subzero conditions. Herein, conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT) decorated with redox-active anthraquinone-2-sulfonic acid sodium (AQS) on the surface is homogeneously dispersed in a poly(acrylic acid) (PAA) hydrogel, which reinforces the conductivity and the stretchability of the obtained AQS–PEDOT/PAA hydrogel electrode. Particularly, with the containing of the H2SO4 + KCl electrolyte, the hydrogel is temperature tolerant and endows the assembled supercapacitor with a wide working temperature of −30 to 90 °C. Due to the extra energy storage contribution of AQS, the device exhibits a high capacitance of 466.5 mF cm−2, a maximum energy density of 41.47 μW h cm−2 and an exceptional cyclic stability of 90% retention after 5000 cycles. Very interestingly, the AQS–PEDOT/PAA electrode shows a remarkable solar-thermal conversion, which significantly boosts the electrochemical performance of the device under subzero conditions. Under solar illumination, the device shows a capacitance enhancement of 39.6% at −30 °C as compared with the device in the dark. This work provides an innovative strategy to spur the sluggish performance of conductive polymer-based hydrogel supercapacitors for practical applications.
- 21 April 2022
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 34 (9) , 4062-4072
Core–Gap–Shell Nanoparticles@Polyaniline with Tunable Plasmonic Chiroptical Activities by pH and Electric Potential Dual Modulation
- 21 April 2022
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 34 (9) , 4062-4072
Core–Gap–Shell Nanoparticles@Polyaniline with Tunable Plasmonic Chiroptical Activities by pH and Electric Potential Dual Modulation
- 1 August 2021
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 341, 130037
Electrochemical sensor for the detection of ppq-level Cd2+ based on a multifunctional composite material by fast scan voltammetry
- 1 August 2021
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 341, 130037
Electrochemical sensor for the detection of ppq-level Cd2+ based on a multifunctional composite material by fast scan voltammetry