Yanzhang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yanzhang Li has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Dong Jiang
Department of Sports Medicine Peking University Third Hospital Beijing China
2 shared publications - Bo Zhang
School of Government, Peking University, Beijing 100081, China
1 shared publication - Cassandra Alda Lee
Department of Orthopaedic Surgery, University of California, Davis, Sacramento, California, USA
1 shared publication - Ding‐Yu Wang
Institute of Sports Medicine of Peking University
1 shared publication - Jia-Kuo Yu
Orthopedic and Sports Medicine Center, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, PR China
1 shared publication - Jie Yang
Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine, Peking University, Beijing 100191, China
1 shared publication
Latest Publications
- Open Access
- 4 May 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (9) , 1539
Shoe-Integrated Sensor System for Diagnosis of the Concomitant Syndesmotic Injury in Chronic Lateral Ankle Instability: A Prospective Double-Blind Diagnostic Test
Chronic lateral ankle instability (CLAI) is commonly secondary to prior lateral ankle ligament injury, and the concomitant latent syndesmosis injury would prolong recovery time and increase the risk of substantial traumatic arthritis. However, differentiating syndesmotic injury from isolated lateral ankle ligament injury in CLAI cases is difficult by conventional physical and radiological examinations. To improve the accuracy of syndesmotic injury diagnosis, a shoe-integrated sensor system (SISS) is proposed. This system measures plantar pressure during walking to detect the presence of syndesmotic injury. The study included 27 participants who had ankle sprains and underwent an examination. Plantar pressure in eight regions of interest was measured for both limbs, and syndesmotic injuries were examined using arthroscopy. The width of the syndesmosis was measured to evaluate its severity. The characteristics of plantar pressure were compared between patients with normal and injured syndesmosis. The results indicated that peak plantar pressure ratios with logistic regression predicted value > 0.51 accurately distinguished concomitant syndesmotic injury during walking, with high sensitivity (80%) and specificity (75%). The post-test probability of having a syndesmotic injury was positively 80% and negatively 25%. These findings demonstrate the effectiveness of cost-effective wearable sensors in objectively diagnosing concomitant syndesmotic injuries in cases of CLAI.
- 4 May 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (9) , 1539
Open AccessShoe-Integrated Sensor System for Diagnosis of the Concomitant Syndesmotic Injury in Chronic Lateral Ankle Instability: A Prospective Double-Blind Diagnostic Test
Chronic lateral ankle instability (CLAI) is commonly secondary to prior lateral ankle ligament injury, and the concomitant latent syndesmosis injury would prolong recovery time and increase the risk of substantial traumatic arthritis. However, differentiating syndesmotic injury from isolated lateral ankle ligament injury in CLAI cases is difficult by conventional physical and radiological examinations. To improve the accuracy of syndesmotic injury diagnosis, a shoe-integrated sensor system (SISS) is proposed. This system measures plantar pressure during walking to detect the presence of syndesmotic injury. The study included 27 participants who had ankle sprains and underwent an examination. Plantar pressure in eight regions of interest was measured for both limbs, and syndesmotic injuries were examined using arthroscopy. The width of the syndesmosis was measured to evaluate its severity. The characteristics of plantar pressure were compared between patients with normal and injured syndesmosis. The results indicated that peak plantar pressure ratios with logistic regression predicted value > 0.51 accurately distinguished concomitant syndesmotic injury during walking, with high sensitivity (80%) and specificity (75%). The post-test probability of having a syndesmotic injury was positively 80% and negatively 25%. These findings demonstrate the effectiveness of cost-effective wearable sensors in objectively diagnosing concomitant syndesmotic injuries in cases of CLAI.
- 28 April 2022
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (11) , 3708-3717
The immediate meniscal allograft transplantation achieved better chondroprotection and less meniscus degeneration than the conventional delayed transplantation in the long‐term
Purpose: The purpose of this study was to compare the long‐term clinical and radiological outcomes between the immediate and delayed meniscus allograft transplantation (MAT).Methods: Nine menisci were transplanted immediately after total meniscectomy (immediate group, IM), and 10 menisci were delayed transplanted in patients with the median of 35 months (range 9–92 months) after total meniscectomy (delayed group, DE). Patient’s subjective clinical outcomes including VAS, IKDC, Lysholm and Tegner scores as well as muscle strength measures were compared. Joint degeneration was evaluated by both radiographs to assess joint space width narrowing, Kellegren–Lawrence (KL) grade and MRI with T2 mapping sequences to quantitatively analyze both cartilage and meniscal allograft degeneration.Results: The median follow‐up time was 10.8 years (range 10–14 years). The IKDC (IM vs DE, 89.8 vs 80.9, n.s.) and Lysholm scores (IM vs DE, 87.7 vs 78.0, n.s.) were close in two groups, while the IM group showed slightly lower VAS (IM vs DE, 0.2 vs 1.5, p = 0.031), higher Tegner score (IM vs DE, 7 vs 3.5 p = 0.021) and better quadriceps muscle strength. The IM group had less joint space narrowing (IM vs DE, 0.35 mm vs 0.71 mm, n.s.), less KL grade progression (IM vs DE, 0.6 vs 1.7, p = 0.041) on radiographs and less chondral lesions development on MRIs (Cartilage Degeneration Index, IM vs DE, 252 vs 2038, p = 0.025). All meniscal grafts exhibited degeneration by showing grade 3 signal on MRI, and 4 (4/9) in the IM group and 8 (8/10) cases in the DE group. The T2 value of cartilage and meniscal allograft in the IM group was close to that of the healthy control and was significantly lower than that of the DE group.Conclusion: Compared to the conventional delayed MAT, the immediate MAT achieved better cartilage and meniscus protection in the long‐term, while its superiority in patient‐reported outcomes was limited.Level of evidence: IV.
- 28 April 2022
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (11) , 3708-3717
The immediate meniscal allograft transplantation achieved better chondroprotection and less meniscus degeneration than the conventional delayed transplantation in the long‐term
Purpose: The purpose of this study was to compare the long‐term clinical and radiological outcomes between the immediate and delayed meniscus allograft transplantation (MAT).Methods: Nine menisci were transplanted immediately after total meniscectomy (immediate group, IM), and 10 menisci were delayed transplanted in patients with the median of 35 months (range 9–92 months) after total meniscectomy (delayed group, DE). Patient’s subjective clinical outcomes including VAS, IKDC, Lysholm and Tegner scores as well as muscle strength measures were compared. Joint degeneration was evaluated by both radiographs to assess joint space width narrowing, Kellegren–Lawrence (KL) grade and MRI with T2 mapping sequences to quantitatively analyze both cartilage and meniscal allograft degeneration.Results: The median follow‐up time was 10.8 years (range 10–14 years). The IKDC (IM vs DE, 89.8 vs 80.9, n.s.) and Lysholm scores (IM vs DE, 87.7 vs 78.0, n.s.) were close in two groups, while the IM group showed slightly lower VAS (IM vs DE, 0.2 vs 1.5, p = 0.031), higher Tegner score (IM vs DE, 7 vs 3.5 p = 0.021) and better quadriceps muscle strength. The IM group had less joint space narrowing (IM vs DE, 0.35 mm vs 0.71 mm, n.s.), less KL grade progression (IM vs DE, 0.6 vs 1.7, p = 0.041) on radiographs and less chondral lesions development on MRIs (Cartilage Degeneration Index, IM vs DE, 252 vs 2038, p = 0.025). All meniscal grafts exhibited degeneration by showing grade 3 signal on MRI, and 4 (4/9) in the IM group and 8 (8/10) cases in the DE group. The T2 value of cartilage and meniscal allograft in the IM group was close to that of the healthy control and was significantly lower than that of the DE group.Conclusion: Compared to the conventional delayed MAT, the immediate MAT achieved better cartilage and meniscus protection in the long‐term, while its superiority in patient‐reported outcomes was limited.Level of evidence: IV.