Fatma A. Abouelenien
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fatma A. Abouelenien has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Mustafa Shukry
Department of Biomedical Sciences, College of Veterinary Medicine, King Faisal University
2 shared publications - Nagham Rafeek Elsaidy
Department of Hygiene and Preventive Medicine, Faculty of Veterinary Medicine, Kafrelsheikh University, Kafrelsheikh 33516, Egypt
2 shared publications - Adel Alkhedaide
Clinical Laboratory Sciences Department, Turabah University College, Taif University, Taif 21995, Saudi Arabia
1 shared publication - Ahmed Gaber
Department of Biology, Faculty of Science Taif University Taif Saudi Arabia
1 shared publication - Mohamed El-Sharnouby
Department of Biotechnology, College of Science, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
1 shared publication - Mohamed Mohamed Soliman
Clinical Laboratory Sciences Department, Turabah University College, Taif University, 21995, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
Enhancement Effects of Water Magnetization and/or Disinfection by Sodium Hypochlorite on Secondary Slaughterhouse Wastewater Effluent Quality and Disinfection By-Products
Wastewater disinfection is one of the most critical issues in protecting human health against exposure to waterborne pathogenies. Chlorine is among the most commonly used disinfectants in many wastewaters’ treatment plants. Nevertheless, disquiets regarding chlorine’s disinfection by-products (DBPs) have grown recently. One of the most effective ways to reduce DBPs generation is to reduce chlorine dosage by increasing disinfectant efficiency. Using magnetic field (MF) in wastewater treatment is one of the promising research topics with significant progression. This study aimed to evaluate the efficiency of using a magnetic field and/or sodium hypochlorite (NaClO) disinfection on secondary slaughterhouse wastewater effluent quality and by-products. Three groups of secondary slaughterhouse wastewater effluents were used: G1 was treated with NaClO only at 0, 2, 4, and 6 mg/L; G2 was treated with exposure to MF at 14,500 gausses, and G3 was pretreated with MF, then NaClO at the exact chlorine dosages and MF strength. The results showed an augmented effect when using a magnetic field as a pre-treatment step before NaClO treatment in the remediation of slaughterhouse wastewater over the use of any of them solely. The removal rate of COD and BOD increased by up to 26 and 20%, respectively, when pre-treatment with MF was employed as a mean percentage at all chlorine dosages, while TSS, TDS, and EC increased by 23.5 and 5.5%, respectively. Over and above, the removal rate for each TN and TP increased by 12 and 6.5% as a mean percentage at all chlorine dosages when using a combination of the two. In addition, pre-treatment by MF reduced the required concentration of NaClO from 6 to 4 mg/L, resulting in an 11% increase in the reduction rate of total coliform count, 8% increase in the reduction rate of fecal coliforms, and 10% increase in the reduction rate of E. coli and 5% in Salmonella via increasing the disinfection efficiency of NaClO. Finally, it decreased the concentration of Chloroform produced by more than 77.2% by using the higher concentration of NaClO (6 mg/L). The issue that approved the promising approach of using MF as a pre-treatment step in the treatment of slaughterhouse wastewater provides the advantage of using smaller dosages of disinfection, lowering the cost of the procedure process, and reducing the harmful concentration of DBPs.
Open AccessEnhancement Effects of Water Magnetization and/or Disinfection by Sodium Hypochlorite on Secondary Slaughterhouse Wastewater Effluent Quality and Disinfection By-Products
Wastewater disinfection is one of the most critical issues in protecting human health against exposure to waterborne pathogenies. Chlorine is among the most commonly used disinfectants in many wastewaters’ treatment plants. Nevertheless, disquiets regarding chlorine’s disinfection by-products (DBPs) have grown recently. One of the most effective ways to reduce DBPs generation is to reduce chlorine dosage by increasing disinfectant efficiency. Using magnetic field (MF) in wastewater treatment is one of the promising research topics with significant progression. This study aimed to evaluate the efficiency of using a magnetic field and/or sodium hypochlorite (NaClO) disinfection on secondary slaughterhouse wastewater effluent quality and by-products. Three groups of secondary slaughterhouse wastewater effluents were used: G1 was treated with NaClO only at 0, 2, 4, and 6 mg/L; G2 was treated with exposure to MF at 14,500 gausses, and G3 was pretreated with MF, then NaClO at the exact chlorine dosages and MF strength. The results showed an augmented effect when using a magnetic field as a pre-treatment step before NaClO treatment in the remediation of slaughterhouse wastewater over the use of any of them solely. The removal rate of COD and BOD increased by up to 26 and 20%, respectively, when pre-treatment with MF was employed as a mean percentage at all chlorine dosages, while TSS, TDS, and EC increased by 23.5 and 5.5%, respectively. Over and above, the removal rate for each TN and TP increased by 12 and 6.5% as a mean percentage at all chlorine dosages when using a combination of the two. In addition, pre-treatment by MF reduced the required concentration of NaClO from 6 to 4 mg/L, resulting in an 11% increase in the reduction rate of total coliform count, 8% increase in the reduction rate of fecal coliforms, and 10% increase in the reduction rate of E. coli and 5% in Salmonella via increasing the disinfection efficiency of NaClO. Finally, it decreased the concentration of Chloroform produced by more than 77.2% by using the higher concentration of NaClO (6 mg/L). The issue that approved the promising approach of using MF as a pre-treatment step in the treatment of slaughterhouse wastewater provides the advantage of using smaller dosages of disinfection, lowering the cost of the procedure process, and reducing the harmful concentration of DBPs.
- Open Access
A Pilot Model for the Treatment of Slaughterhouse Wastewater Using Zeolite or Psidium-Leaf Powder as a Natural Coagulant, Followed by Filtration with Rice Straw, in Comparison with an Inorganic Coagulant
Slaughterhouse wastewater (SHWW) is classified as industrial waste, which is exceptionally harmful to the environment due to its high content of biological oxygen demand (BOD), chemical oxygen demand (COD), and suspended solids, which result from high organic and nutrient loading. This study used a pilot system to treat SHWW from the Kafrelsheikh Governorate slaughterhouse, which includes a three-step process. It started with sedimentation, then coagulation and flocculation using different concentrations of each: natural zeolites (Z) and Psidium guajava-leaf powder (GLP) as green and environmentally friendly agents, and alum (A) as an inorganic coagulant. The final step was filtration with physically treated rice straw (RS). Each step was judged separately by measuring the removal percentages of each analyzed pollutant, and finally, the overall process was evaluated using the same method. A jar test was used to determine the best concentration of each coagulant used. The measured pollutants were physico-chemical, such as COD, BOD, TSS, TKN, and turbidity. The bacteriological examination included TBC, TCC, and FC. The jar-test results determined that Z 1200 mg/L SHWW, GLP 1 g/L, and A 6 g/L were the best concentrations for each coagulant used. In the coagulation step, GLP 1 g/L gave the highest removal percentage of TSS, TKN, EC, and turbidity, while Z 1200 mg/L gave the highest removal percentage of COD, TDS, TBC, and TCC. From these results, it was concluded that a natural coagulant performs better than a chemical one. Finally, judging the overall pilot test system after applying the filtration with physically treated RS, we found that the best removal efficiencies were obtained from Z 1200 mg/L combined with RS. This combination resulted in 90.58, 83.47, 88.75, 54.89, 21.39, 34.49, 84.16, 99.98, and 99.93 removal percentages for BOD, COD, TSS, TKN, EC, turbidity, TBC, and TCC, respectively.
Open AccessA Pilot Model for the Treatment of Slaughterhouse Wastewater Using Zeolite or Psidium-Leaf Powder as a Natural Coagulant, Followed by Filtration with Rice Straw, in Comparison with an Inorganic Coagulant
Slaughterhouse wastewater (SHWW) is classified as industrial waste, which is exceptionally harmful to the environment due to its high content of biological oxygen demand (BOD), chemical oxygen demand (COD), and suspended solids, which result from high organic and nutrient loading. This study used a pilot system to treat SHWW from the Kafrelsheikh Governorate slaughterhouse, which includes a three-step process. It started with sedimentation, then coagulation and flocculation using different concentrations of each: natural zeolites (Z) and Psidium guajava-leaf powder (GLP) as green and environmentally friendly agents, and alum (A) as an inorganic coagulant. The final step was filtration with physically treated rice straw (RS). Each step was judged separately by measuring the removal percentages of each analyzed pollutant, and finally, the overall process was evaluated using the same method. A jar test was used to determine the best concentration of each coagulant used. The measured pollutants were physico-chemical, such as COD, BOD, TSS, TKN, and turbidity. The bacteriological examination included TBC, TCC, and FC. The jar-test results determined that Z 1200 mg/L SHWW, GLP 1 g/L, and A 6 g/L were the best concentrations for each coagulant used. In the coagulation step, GLP 1 g/L gave the highest removal percentage of TSS, TKN, EC, and turbidity, while Z 1200 mg/L gave the highest removal percentage of COD, TDS, TBC, and TCC. From these results, it was concluded that a natural coagulant performs better than a chemical one. Finally, judging the overall pilot test system after applying the filtration with physically treated RS, we found that the best removal efficiencies were obtained from Z 1200 mg/L combined with RS. This combination resulted in 90.58, 83.47, 88.75, 54.89, 21.39, 34.49, 84.16, 99.98, and 99.93 removal percentages for BOD, COD, TSS, TKN, EC, turbidity, TBC, and TCC, respectively.