MSManoj Stanley

Manoj Stanley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Manoj Stanley has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Classical interfaces for controlling cryogenic quantum computing technologies

    by Jack C. Brennan, João Barbosa, Chong Li, Meraj Ahmad, Fiheon Imroze, Calum Rose, Wridhdhisom Karar, Manoj Stanley, Hadi Heidari, Nick M. Ridler, et al.

    Quantum processors have the potential to revolutionize computing on a scale unseen since the development of semiconductor technology in the middle of the twentieth century. However, while there is now huge activity and investment in the field, there are a number of challenges that must be overcome before the technology can be fully realized. Of primary concern is the development of the classical technology required to interface with quantum systems, as we push toward a new era of high-performance, large-scale quantum computing. In this review, we briefly discuss some of the main challenges facing the development of universally useful quantum computers and the different architectures being investigated. We are primarily concerned with cryogenic quantum systems. These systems are among the most mature quantum computing architectures to date and are garnering a lot of both industrial and academic attention. We present and analyze the leading methods of interfacing with quantum processors, both now and for the next generation of larger, multi-qubit systems. Recent advancements in control cryoelectronics, both semiconducting and superconducting, are covered, while a view toward newer methods such as optical and wireless qubit interfaces is also presented.


  • Open Access

    A Technique to Improve Accuracy of S-Parameter Measurements of Coaxial Connectorized Devices at Cryogenic Temperatures

    by Manoj Stanley, Murat Celep, Asem Elarabi, Martin Salter, Dilbagh Singh, James Skinner, Sang-Hee Shin, Nick M. Ridler

    Recent developments in microwave-based quantum computing technologies have motivated the need for the development of new and improved cryogenic microwave devices packaged in coaxial connectorized technology, and for their performance to be accurately characterized through S-parameter measurements made at cryogenic operating temperatures. To facilitate such accurate characterization, S-parameter measurement systems utilizing in-situ calibration techniques at cryogenic temperatures have been developed. This required use of cryogenic RF switches inside cryostats to select between calibration standards and devices to perform calibration and measurement in a single cooling cycle. However, this caused significant measurement errors due to non-identical signal paths due to differences in switch paths limiting the measurement accuracy of such measurement systems. In this work, a new technique is proposed to significantly improve the accuracy of cryogenic S-parameter measurements of coaxial connectorized devices by accounting for non-ideal effects in such switch-based cryogenic calibration units. The technique is demonstrated at room temperature (296 K) and cryogenic temperature (1.5 K) through S-parameter measurements of coaxial devices with up to two ports.


  • Open Access

    In-operando microwave scattering-parameter calibrated measurement of a Josephson traveling wave parametric amplifier

    by S.-H. Shin, M. Stanley, W. N. Wong, T. Sweetnam, A. Elarabi, T. Lindström, N. M. Ridler, S. E. de Graaf

    Superconducting traveling wave parametric amplifiers (TWPAs) are broadband near-quantum limited microwave amplifiers commonly used for qubit readout and a wide range of other applications in quantum technologies. The performance of these amplifiers depends on achieving impedance matching to minimize reflected signals. Here, we apply a microwave calibration technique to extract the S-parameters of a Josephson junction based TWPA in-operando. This enables reflections occurring at the TWPA and its extended network of components to be quantified, and we find that the in-operation performance can be well described by the off-state measured S-parameters.


  • Open Access

    RF and microwave metrology for quantum computing – recent developments at the UK’s National Physical Laboratory

    by Manoj Stanley, Xiaobang Shang, Murat Celep, Martin Salter, Sebastian de Graaf, Tobias Lindstrom, Sang-Hee Shin, James Skinner, Dilbagh Singh, Daniel Stokes, et al.

    Development of large-scale quantum computing systems will require radio frequency (RF) and microwave technologies operating reliably at cryogenic temperatures down to tens of milli-Kelvin (mK). The quantum bits in the most promising quantum computing technologies such as the superconducting quantum computing are designed using principles of microwave engineering and operated using microwave signals. The control, readout, and coupling of qubits are implemented using a network of microwave components operating at various temperature stages. To ensure reliable operation of quantum computing systems, it is critical to ensure optimal performance of these microwave components and qubits at their respective operating temperatures, which can be as low as mK temperatures. It is, therefore, critical to understand the microwave characteristics of waveforms, components, circuits, networks, and systems at cryogenic temperatures. The UK’s National Physical Laboratory (NPL) is focussed on developing new microwave measurement capabilities through the UK’s National Quantum Technologies Programme to address various microwave test and measurement challenges in quantum computing. This includes the development of various measurement capabilities to characterize the microwave performance of quantum and microwave devices and substrate materials at cryogenic temperatures. This paper summarizes the roadmap of activities at NPL to address these microwave metrology challenges in quantum computing.


  • Characterizing S-Parameters of Microwave Coaxial Devices With up to Four Ports at Temperatures of 3 K and Above for Quantum Computing Applications

    by Manoj Stanley, Martin Salter, Jonas Urbonas, James Skinner, Sang-Hee Shin, Sebastian E. de Graaf, Nick M. Ridler

    Multi-port microwave devices operating at cryogenic temperatures are used in quantum computing to enable complex quantum operations. These components need to be precisely characterized at their operating temperature to ensure adequate overall system performance. In this work, an S-parameter measurement system to characterize the performance of coaxial connectorized microwave devices having up to four ports at temperatures of 3 K and above is presented. A four-port calibration setup is implemented at the 3 K temperature stage inside a dilution refrigerator. Measurement results for devices under test at 3 K are presented and the performance of the measurement system is evaluated.


  • Open Access

    Broadband Coaxial S-Parameter Measurements for Cryogenic Quantum Technologies

    by Sang-Hee Shin, Manoj Stanley, James Skinner, Sebastian E. de Graaf, Nick M. Ridler

    Development of RF and microwave metrology capabilities at cryogenic temperatures is critical for the development of high-performance microwave devices to facilitate commercialization of cryogenic quantum technologies. This article presents a broadband microwave S-parameter calibration scheme suitable for cryogenic environments operating at temperatures down to tens of milli-kelvin (mK). The technique is based on a weighted multi-line thru-reflect-line (TRL) calibration approach and is demonstrated using coaxial air line calibration standards. One-and two-port microwave devices commonly used in cryogenic quantum computing applications, a cryogenic 50 $~\Omega$ matched load and a cryogenic 6 dB attenuator, were measured. The measured results at mK temperatures indicate that when combined with calibration standards of appropriate electrical length, the weighted multi-line TRL calibration scheme allows broadband frequency coverage compared to conventional TRL calibration schemes utilizing a single line standard. The mechanical and electrical properties of the line standards at mK temperatures were investigated and discussed. These findings establish the feasibility of utilizing multiple off-the-shelf coaxial air lines to enhance the frequency range of calibrations at mK temperatures.


  • Open Access

    Determination of the Permittivity of Transmission Lines at Milli-Kelvin Temperatures

    by Manoj Stanley, Rowan Parker-Jervis, James Skinner, Sebastian De Graaf, Tobias Lindström, John E. Cunningham, Nick M. Ridler

    Many quantum technologies rely heavily on propagation of RF and microwave signals through devices at cryogenic temperatures, and detailed understanding of materials and signal propagation is therefore key to improving the performance of quantum circuits. The properties of dielectric substrate materials used for transmission lines (TLs) such as their permittivity need to be precisely determined to design high performance quantum integrated circuits. In this paper, we discuss a measurement technique for determining the effective permittivity of a TL at mK temperatures. The technique utilizes S-parameter measurements of multiple TLs to reliably extract the effective permittivity of the TL implemented in a substrate material. The technique is demonstrated using measured S-parameters of grounded co-planar waveguide (GCPW) at 296 K and 15 mK. The effective permittivity of the TL at 296 K and 15 mK are determined from measurements and compared. We observed the effective permittivity determinations at 15 mK to be approximately frequency independent and calculated the relative permittivity of Rogers RO4350B material at 15 mK to be 3.64. There is no significant deviation from this relative permittivity value with respect to manufacturer data and from measured data at 296 K.


  • Open Access

    Polymer-Based 3-D Printed 140 to 220 GHz Metal Waveguide Thru Lines, Twist and Filters

    by Roshan Payapulli, Liyan Zhu, Sang-Hee Shin, Manoj Stanley, Nick M. Ridler, Stepan Lucyszyn

    This paper demonstrates the current state-of-the-art in low-cost, low loss ruggedized polymer-based 3-D printed G-band (140 to 220 GHz) metal-pipe rectangular waveguide (MPRWG) components. From a unique and exhaustive up-to-date literature review, the main limitations for G-band split-block MPRWGs are identified as electromagnetic (EM) radiation leakage, assembly part alignment and manufacturing accuracy. To mitigate against leakage and misalignment, we investigate a ‘trough-and-lid’ split-block solution. This approach is successfully employed in proof-of-concept thru lines, and in the first polymer-based 3-D printed 90° twist and symmetrical diaphragm inductive iris-coupled bandpass filters (BPFs) operating above 110 GHz. An inexpensive desktop masked stereolithography apparatus 3-D printer and a commercial copper electroplating service are used. Surface roughness losses are calculated and applied to EM (re-)simulations, using two modifications of the Hemispherical model. The 7.4 mm thru line exhibits a measured average dissipative attenuation of only 12.7 dB/m, with rectangular-to-trapezoidal cross-sectional distortion being the main contributor to loss. The 90° twist exhibits commensurate measured performance to its commercial counterpart, despite the much lower manufacturing costs. A detailed time-domain reflectometry analysis of flange quality for the thru lines and 90° twists has also been included. Finally, a new systematic iris corner rounding compensation technique, to correct passband frequency down-shifting is applied to two BPFs. Here, the 175 GHz exemplar exhibits only 0.5% center frequency up-shifting. The trough-and-lid assembly is now a viable solution for new upper-mm-wave MPRWG components. With this technology becoming less expensive and more accurate, higher frequencies and/or more demanding specifications can be implemented.


  • Open Access

    Characterizing Scattering Parameters of Superconducting Quantum Integrated Circuits at Milli-Kelvin Temperatures

    by Manoj Stanley, Sebastian De Graaf, Teresa Honigl-Decrinis, Tobias Lindstrom, Nick M. Ridler

    Designing large-scale superconducting quantum circuits involves complex microwave engineering to minimize loss, spurious reflections, and signal crosstalk. Essential for engineering more complex circuits is precise knowledge of devices’ microwave performance, which can be characterized by measuring its calibrated scattering parameters (S-parameters) at mK temperatures. In this work, we introduce a full 2-port calibrated S-parameter measurement setup which can characterize superconducting quantum integrated circuits and other RF integrated circuits operating at mK temperatures. The design and architecture of the measurement system consisting of in-house developed microwave calibration unit (MCU) housing the newly designed cryogenic calibration standards and the device under test (DUT) is discussed in detail. The measurement setup is then used to demonstrate the first calibrated S-parameter measurements of an in-house developed superconducting qubit integrated circuit at mK temperature.


  • Open Access

    3-D Printed Plug and Play Prototyping for Low-Cost Sub-THz Subsystems

    by Sang-Hee Shin, Roshan Payapulli, Liyan Zhu, Manoj Stanley, Xiaobang Shang, Nick M. Ridler, Stepan Lucyszyn

    Polymer-based additive manufacturing using 3-D printing for upper-millimeter-wave ( ca. 100 to 300 GHz) frequency applications is now emerging. Building on our previous work, with metal-pipe rectangular waveguides and free-space quasi-optical components, this paper brings the two media together at G-band (140 to 220 GHz), by demonstrating a compact multi-channel front-end subsystem. Here, the proof-of-concept demonstrator integrates eight different types of 3-D printed components (30 individual components in total). In addition, the housing for two test platforms and the subsystem are all 3-D printed as single pieces, to support plug and play development; offering effortless component assembly and alignment. We introduce bespoke free-space TRM calibration and measurement schemes with our quasi-optical test platforms. Equal power splitting plays a critical role in our multi-channel application. Here, we introduce a broadband 3-D printed quasi-optical beamsplitter for upper-millimeter-wave applications. Our quantitative and/or qualitative performance evaluations for individual components and the complete integrated subsystem, demonstrate the potential for using consumer-level desktop 3-D printing technologies at such high frequencies. This work opens-up new opportunities for low-cost, rapid prototyping and small-batch production of complete millimeter-wave front-end subsystems.