Vanni Toigo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vanni Toigo has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- Diego Marcuzzi
Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4
4 shared publications - Loris Zanotto
Consorzio RFX (CNR, ENEA, INFN, Universit di Padova, Acciaierie Venete SpA), Padua, Italy
4 shared publications - Marco Boldrin
Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4
4 shared publications - Alberto Maistrello
Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4
3 shared publications G. Berton
Consorzio RFX 1 , Corso Stati Uniti 4, 35127 Padova (PD), Italy
3 shared publicationsL. Grando
Consorzio RFX 1 , Corso Stati Uniti 4, 35127 Padova (PD), Italy
3 shared publications
Latest Publications
- Open Access
- 27 April 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 41 (3)
Design of a large nonevaporable getter pump for the full size ITER beam source prototype
An improvement for the vacuum system of the multidriver radio frequency (RF) prototype negative ion source SPIDER has been developed, to allow operating at high RF power, while minimizing the breakdown probability on the outside of the plasma source. A first-of-its-kind large nonevaporable getter (NEG) pump, based on a modular design of 384 cartridges totaling about 350 kg of ZAO® alloy (composed by Zr-Ti-V-Al) with an installed pumping speed at a room temperature of 330 m3/s for hydrogen, will complement the existing pumping system, based on eight cryogenic pumps and four turbomolecular pumps totaling about 90 m3/s in hydrogen. The vessel pressure during absorption is expected to be between 20 and 40 mPa, while during the getter regeneration, the peak operating pressure will be around 2 Pa. The NEG pump will use an additional vessel module, with integrated thermal shields to protect the in-vessel components during activation and regeneration of the pump, to be carried out at temperatures in the range of 550–600 °C. Integrated thermal analyses were carried out to verify the low heat load on pre-existing in-vessel components with a low limit of acceptable temperature, and to provide boundary conditions for the mechanical verifications of the pump structure. The scenario of cyclic hydrogen load was calculated considering the SPIDER operation modes, the expected gas throughput, and the cumulated load to the pump, to determine the regeneration temperature and auxiliary pumping necessary to make the regeneration duration compatible with the high availability of the system. The upgrade of the auxiliary pumping system is also described, as well as the mitigation of air or water exposure risk during regeneration of the NEG pump.
- 27 April 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 41 (3)
Open AccessDesign of a large nonevaporable getter pump for the full size ITER beam source prototype
An improvement for the vacuum system of the multidriver radio frequency (RF) prototype negative ion source SPIDER has been developed, to allow operating at high RF power, while minimizing the breakdown probability on the outside of the plasma source. A first-of-its-kind large nonevaporable getter (NEG) pump, based on a modular design of 384 cartridges totaling about 350 kg of ZAO® alloy (composed by Zr-Ti-V-Al) with an installed pumping speed at a room temperature of 330 m3/s for hydrogen, will complement the existing pumping system, based on eight cryogenic pumps and four turbomolecular pumps totaling about 90 m3/s in hydrogen. The vessel pressure during absorption is expected to be between 20 and 40 mPa, while during the getter regeneration, the peak operating pressure will be around 2 Pa. The NEG pump will use an additional vessel module, with integrated thermal shields to protect the in-vessel components during activation and regeneration of the pump, to be carried out at temperatures in the range of 550–600 °C. Integrated thermal analyses were carried out to verify the low heat load on pre-existing in-vessel components with a low limit of acceptable temperature, and to provide boundary conditions for the mechanical verifications of the pump structure. The scenario of cyclic hydrogen load was calculated considering the SPIDER operation modes, the expected gas throughput, and the cumulated load to the pump, to determine the regeneration temperature and auxiliary pumping necessary to make the regeneration duration compatible with the high availability of the system. The upgrade of the auxiliary pumping system is also described, as well as the mitigation of air or water exposure risk during regeneration of the NEG pump.
- 20 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (3) , 927-935
SPIDER, the Negative Ion Source Prototype for ITER: Overview of Operations and Cesium Injection
An overview of the recent operations and the main results of cesium injection in the Source for the Production of Ions of Deuterium Extracted from Rf plasma (SPIDER) negative ion source are described in this contribution. In experiments without cesium injection, all SPIDER plants were tested to verify the basic expectations on the operational parameters (e.g., electron cooling effectiveness of magnetic filter field) and to determine its operational region. For beam properties, it was shown that the current density varies across the beam in the vertical direction. In preliminary cesium experiments, the expected increase of negative ion current and simultaneous decrease of co-extracted electrons were found, along with the influence of the control parameters (polarization of the plasma electrodes, magnetic filter field) on the SPIDER beam uniformity in the horizontal and vertical directions. It was shown that non-Gaussian tails can be identified in the angular distribution on the plane perpendicular to the beam propagation direction. Stray particles, nonhomogeneous beam and large divergence might result in unexpected heat and particle loads over ITER neutral beam injector (NBI) accelerator grids; it is the goal of SPIDER to assess and possibly to identify suitable methods for controlling these beam features. A major shutdown, planned for late 2021, to solve the issues identified during the operation and to carry out scheduled modifications, is outlined. Such improvements are expected to allow SPIDER to pursue the ITER requirements in terms of negative ion current, electron-to-ion ratio, and beam duration.
- 20 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (3) , 927-935
SPIDER, the Negative Ion Source Prototype for ITER: Overview of Operations and Cesium Injection
An overview of the recent operations and the main results of cesium injection in the Source for the Production of Ions of Deuterium Extracted from Rf plasma (SPIDER) negative ion source are described in this contribution. In experiments without cesium injection, all SPIDER plants were tested to verify the basic expectations on the operational parameters (e.g., electron cooling effectiveness of magnetic filter field) and to determine its operational region. For beam properties, it was shown that the current density varies across the beam in the vertical direction. In preliminary cesium experiments, the expected increase of negative ion current and simultaneous decrease of co-extracted electrons were found, along with the influence of the control parameters (polarization of the plasma electrodes, magnetic filter field) on the SPIDER beam uniformity in the horizontal and vertical directions. It was shown that non-Gaussian tails can be identified in the angular distribution on the plane perpendicular to the beam propagation direction. Stray particles, nonhomogeneous beam and large divergence might result in unexpected heat and particle loads over ITER neutral beam injector (NBI) accelerator grids; it is the goal of SPIDER to assess and possibly to identify suitable methods for controlling these beam features. A major shutdown, planned for late 2021, to solve the issues identified during the operation and to carry out scheduled modifications, is outlined. Such improvements are expected to allow SPIDER to pursue the ITER requirements in terms of negative ion current, electron-to-ion ratio, and beam duration.
- 10 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (11) , 3970-3976
Radio Frequency Generators Based on Solid State Amplifiers for the NBTF and ITER Projects
The article will present and discuss the issues found in Source for Production of Ion of Deuterium Extracted from RF plasma (SPIDER) experiment with the operation of the radio frequency (RF) generators based on self-excited tetrode oscillators and the advantages expected from their replacement with RF solid-state amplifiers. The assessment of the solution based on new solid-state amplifiers for both SPIDER and Megavolt ITER Injector and Concept Advancement (MITICA) experiments operating in Padua, Italy, in the Neutral Beam Test Facility, will be described, outlining the main design challenges and open points.
- 10 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (11) , 3970-3976
Radio Frequency Generators Based on Solid State Amplifiers for the NBTF and ITER Projects
The article will present and discuss the issues found in Source for Production of Ion of Deuterium Extracted from RF plasma (SPIDER) experiment with the operation of the radio frequency (RF) generators based on self-excited tetrode oscillators and the advantages expected from their replacement with RF solid-state amplifiers. The assessment of the solution based on new solid-state amplifiers for both SPIDER and Megavolt ITER Injector and Concept Advancement (MITICA) experiments operating in Padua, Italy, in the Neutral Beam Test Facility, will be described, outlining the main design challenges and open points.
- 10 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (11) , 3941-3946
The Full-Voltage Operation of the Acceleration Grid Power Supply for SPIDER Experiment
In SPIDER, the full-scale prototype of the negative ion source of the ITER Heating Neutral Beam Injectors, negative ions of hydrogen or deuterium are extracted and accelerated by a set of grids. This article describes the process and the technical solutions that allowed achieving the asseveration to operate the Acceleration Grid Power Supply of SPIDER at full voltage (-96 kV), reports the first experimental results, and discusses some possible enhancements that have been identified.
- 10 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (11) , 3941-3946
The Full-Voltage Operation of the Acceleration Grid Power Supply for SPIDER Experiment
In SPIDER, the full-scale prototype of the negative ion source of the ITER Heating Neutral Beam Injectors, negative ions of hydrogen or deuterium are extracted and accelerated by a set of grids. This article describes the process and the technical solutions that allowed achieving the asseveration to operate the Acceleration Grid Power Supply of SPIDER at full voltage (-96 kV), reports the first experimental results, and discusses some possible enhancements that have been identified.
- 29 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (9) , 2755-2762
Strategy for Vacuum Insulation Tests of MITICA 1 MV Electrostatic Accelerator
The electrical insulation of the Megavolt ITER Injector and Concept Advancement (MITICA) beam source (BS) at 1 MV in vacuum is a challenging issue, which could not be fully addressed so far on the basis of experimental results and of theoretical models available in literature. A specific high-voltage (HV) test campaign is being prepared to validate and optimize the voltage holding capability of the BS insulation under realistic conditions, using full-size mockup electrodes reproducing in detail the geometry of the BS and accelerator. The proposed test strategy will address both the single-gap and the multistage insulation, so as to obtain a verification of voltage holding at 1 MV before the installation of the real components. This approach is intended to reduce the risk related to the HV insulation at 1 MV and, if necessary, to allow the development of effective corrections. In this article, the test motivations and requirements are defined, and the electrode implementation and diagnostic setup are described. Finally, the test configurations and the experimental procedure are discussed.
- 29 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (9) , 2755-2762
Strategy for Vacuum Insulation Tests of MITICA 1 MV Electrostatic Accelerator
The electrical insulation of the Megavolt ITER Injector and Concept Advancement (MITICA) beam source (BS) at 1 MV in vacuum is a challenging issue, which could not be fully addressed so far on the basis of experimental results and of theoretical models available in literature. A specific high-voltage (HV) test campaign is being prepared to validate and optimize the voltage holding capability of the BS insulation under realistic conditions, using full-size mockup electrodes reproducing in detail the geometry of the BS and accelerator. The proposed test strategy will address both the single-gap and the multistage insulation, so as to obtain a verification of voltage holding at 1 MV before the installation of the real components. This approach is intended to reduce the risk related to the HV insulation at 1 MV and, if necessary, to allow the development of effective corrections. In this article, the test motivations and requirements are defined, and the electrode implementation and diagnostic setup are described. Finally, the test configurations and the experimental procedure are discussed.