Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuet-Tung Tse has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantitative Assessment of Full Size Microplastics in Bottled and Tap Water Samples in Hong Kong

    by Yuet-Tung Tse, Sidney Man-Ngai Chan, Eric Tung-Po Sze

    Human exposure to microplastics (MPs) through drinking water has drawn serious concern recently because of the potential adverse health effects. Although there are reports on the occurrence of MPs in bottled water, little is known about the abundance of a whole spectrum of MPs with sizes ranging from 1 µm to 5 mm due to the restrictions of conventional MPs detection methods. Some studies using micro-Raman spectroscopy can achieve MPs with a size of −1, while MPs with a size of −1, where the MPs abundance from mineral water samples were significantly more than distilled and spring water samples. The modal size and shape of MPs were found at 1 µm and fragments, respectively. Besides, three tap water samples obtained locally were analyzed and compared with the bottled water samples, where less MPs were found in tap water samples. In addition, contamination of MPs from bottle and cap and interference by addition of mineral salts were studied, where no significant difference from all these processes to the control sample was found, suggesting the major contamination of MPs was from other manufacturing processes. Estimated daily intake (EDI) of MPs increased substantially when data of small MPs are included, suggesting that previously reports on exposure of MPs from drinking water might be underestimated, as only large MPs were considered.


  • Open Access

    Flow Cytometry as a Rapid Alternative to Quantify Small Microplastics in Environmental Water Samples

    by Yuet-Tung Tse, Hoi-Shing Lo, Sidney Man-Ngai Chan, Eric Tung-Po Sze

    The most frequently used method to quantify microplastics (MPs) visually by microscope is time consuming and labour intensive, where the method is also hindered by the size limitation at 10 µm or even higher. A method is proposed to perform pre-concentration of MPs by vacuum filtration, hydrogen peroxide wet digestion, fluorescent staining and flow cytometric determination to rapidly detect and quantify small MPs sized from 1–50 µm. The method performance was evaluated by the spiking of seven different types of polymer, including polystyrene (PS), low-density polyethylene (LDPE), polypropylene (PP), poly(methyl methacrylate) (PMMA), polyvinyl chloride (PVC), polylactic acid (PLA) and acrylonitrile butadiene styrene (ABS) at different levels (400, 4000, 40,000 particles mL−1), with a satisfactory overall % recoveries (101 ± 19.4%) observed, where in general no significant difference between the two methods was observed. Furthermore, a pre-concentration process by vacuum filtration was introduced to reduce the matrix effect. After pre-concentration, satisfactory % recoveries and accuracy in MP counts resulted from both ultrapure water (94.33 ± 11.16%) and sea water (103.17 ± 9.50%) samples. The validated method using flow cytometry can be used to quantify MPs in environmental water samples that can reduce time and human resources.