Juan Manuel Gracia Baena
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Juan Manuel Gracia Baena has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Jose Joaquin Rieta
BioMIT.org, Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain
4 shared publications - Raúl Alcaraz
Research Group in Electronic, Biomedical and Telecommunication Engineering, University of Castilla-La Mancha, 16071 Cuenca, Spain
4 shared publications - Fernando Hornero
Cardiovascular Surgery Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain
3 shared publications - Aikaterini Vraka
Universitat Politècnica de València
2 shared publications - Immaculada Calaf Valls
Affiliation Applied Epidemiology Unit, Department of Medicine and Surgery, University of Lleida, Lleida, Spain
1 shared publication - Jesus Cano
BioMIT.org, Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain
1 shared publication
Latest Publications
- 31 August 2024
- Published by Springer Nature
- p. 162-170
Improved Hypertension Detection Models Utilizing Pulse Rate Variability and Asymmetry
- 31 August 2024
- Published by Springer Nature
- p. 162-170
Improved Hypertension Detection Models Utilizing Pulse Rate Variability and Asymmetry
- Open Access
Novel Entropy-Based Metrics for Long-Term Atrial Fibrillation Recurrence Prediction Following Surgical Ablation: Insights from Preoperative Electrocardiographic Analysis
Atrial fibrillation (AF) is a prevalent cardiac arrhythmia often treated concomitantly with other cardiac interventions through the Cox–Maze procedure. This highly invasive intervention is still linked to a long-term recurrence rate of approximately 35% in permanent AF patients. The aim of this study is to preoperatively predict long-term AF recurrence post-surgery through the analysis of atrial activity (AA) organization from non-invasive electrocardiographic (ECG) recordings. A dataset comprising ECGs from 53 patients with permanent AF who had undergone Cox–Maze concomitant surgery was analyzed. The AA was extracted from the lead V1 of these recordings and then characterized using novel predictors, such as the mean and standard deviation of the relative wavelet energy ( and ) across different scales, and an entropy-based metric that computes the stationary wavelet entropy variability (). The individual predictors exhibited limited predictive capabilities to anticipate the outcome of the procedure, with the yielding a classification accuracy (Acc) of 68.07%. However, the assessment of the for the seventh scale (), which encompassed frequencies associated with the AA, stood out as the most promising individual predictor, with sensitivity (Se) and specificity (Sp) values of 80.83% and 67.09%, respectively, and an Acc of almost 75%. Diverse multivariate decision tree-based models were constructed for prediction, giving priority to simplicity in the interpretation of the forecasting methodology. In fact, the combination of the and consistently outperformed the individual predictors and excelled in predicting post-surgery outcomes one year after the Cox–Maze procedure, with Se, Sp, and Acc values of approximately 80%, thus surpassing the results of previous studies based on anatomical predictors associated with atrial function or clinical data. These findings emphasize the crucial role of preoperative patient-specific ECG signal analysis in tailoring post-surgical care, enhancing clinical decision making, and improving long-term clinical outcomes.Open AccessNovel Entropy-Based Metrics for Long-Term Atrial Fibrillation Recurrence Prediction Following Surgical Ablation: Insights from Preoperative Electrocardiographic Analysis
Atrial fibrillation (AF) is a prevalent cardiac arrhythmia often treated concomitantly with other cardiac interventions through the Cox–Maze procedure. This highly invasive intervention is still linked to a long-term recurrence rate of approximately 35% in permanent AF patients. The aim of this study is to preoperatively predict long-term AF recurrence post-surgery through the analysis of atrial activity (AA) organization from non-invasive electrocardiographic (ECG) recordings. A dataset comprising ECGs from 53 patients with permanent AF who had undergone Cox–Maze concomitant surgery was analyzed. The AA was extracted from the lead V1 of these recordings and then characterized using novel predictors, such as the mean and standard deviation of the relative wavelet energy ( and ) across different scales, and an entropy-based metric that computes the stationary wavelet entropy variability (). The individual predictors exhibited limited predictive capabilities to anticipate the outcome of the procedure, with the yielding a classification accuracy (Acc) of 68.07%. However, the assessment of the for the seventh scale (), which encompassed frequencies associated with the AA, stood out as the most promising individual predictor, with sensitivity (Se) and specificity (Sp) values of 80.83% and 67.09%, respectively, and an Acc of almost 75%. Diverse multivariate decision tree-based models were constructed for prediction, giving priority to simplicity in the interpretation of the forecasting methodology. In fact, the combination of the and consistently outperformed the individual predictors and excelled in predicting post-surgery outcomes one year after the Cox–Maze procedure, with Se, Sp, and Acc values of approximately 80%, thus surpassing the results of previous studies based on anatomical predictors associated with atrial function or clinical data. These findings emphasize the crucial role of preoperative patient-specific ECG signal analysis in tailoring post-surgical care, enhancing clinical decision making, and improving long-term clinical outcomes. - Open Access
- 21 June 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (6) , e0287508
Impact of severe aortic stenosis on quality of life
Introduction: Among individuals ≥ 65 years old, aortic stenosis is highly prevalent and the number of cases is expected to increase in the coming decades, due to the increased life expectancy. Nevertheless, the actual aortic stenosis burden is not well known in population settings and the impact of aortic stenosis on quality of life has not been studied. The aim of this study was to evaluate aortic stenosis impact on health-related quality of life in patients > 65 years old.Methods: An epidemiological case-control study was carried out to compare quality of life in patients ≥65 years old with severe symptomatic aortic stenosis. Demographical and clinical information was prospectively obtained and quality of life information was collected with the Short Form Health Survey_v2 (SF-12) questionnaire. The association between quality of life and aortic stenosis was determined using multiple logistic regression models.Results: Patients with severe aortic stenosis self-perceived worse quality of life on all dimensions and summary components of the SF-12 questionnaire. In the final multiple logistic regression model a significant inverse association was observed between the dimensions ‘physical role’ and ‘social role’ (p = 0.002 and p = 0.005) and an association close to significance with ‘physical role’ (p = 0.052) of the SF-12 questionnaire.Conclusion: The use of quality of life scales allows the assessment of the impact of aortic stenosis on quality of life and may improve the therapeutic approach to severe aortic stenosis, providing evidence for patient‐centered care.
- 21 June 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (6) , e0287508
Open AccessImpact of severe aortic stenosis on quality of life
Introduction: Among individuals ≥ 65 years old, aortic stenosis is highly prevalent and the number of cases is expected to increase in the coming decades, due to the increased life expectancy. Nevertheless, the actual aortic stenosis burden is not well known in population settings and the impact of aortic stenosis on quality of life has not been studied. The aim of this study was to evaluate aortic stenosis impact on health-related quality of life in patients > 65 years old.Methods: An epidemiological case-control study was carried out to compare quality of life in patients ≥65 years old with severe symptomatic aortic stenosis. Demographical and clinical information was prospectively obtained and quality of life information was collected with the Short Form Health Survey_v2 (SF-12) questionnaire. The association between quality of life and aortic stenosis was determined using multiple logistic regression models.Results: Patients with severe aortic stenosis self-perceived worse quality of life on all dimensions and summary components of the SF-12 questionnaire. In the final multiple logistic regression model a significant inverse association was observed between the dimensions ‘physical role’ and ‘social role’ (p = 0.002 and p = 0.005) and an association close to significance with ‘physical role’ (p = 0.052) of the SF-12 questionnaire.Conclusion: The use of quality of life scales allows the assessment of the impact of aortic stenosis on quality of life and may improve the therapeutic approach to severe aortic stenosis, providing evidence for patient‐centered care.
- Open Access
- 1 June 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (6) , 176
The Relevance of Heart Rate Fluctuation When Evaluating Atrial Substrate Electrical Features in Catheter Ablation of Paroxysmal Atrial Fibrillation
Coronary sinus (CS) catheterization is critical during catheter ablation (CA) of atrial fibrillation (AF). However, the association of CS electrical activity with atrial substrate modification has been barely investigated and mostly limited to analyses during AF. In sinus rhythm (SR), atrial substrate modification is principally assessed at a global level through P-wave analysis. Cross-correlating CS electrograms (EGMs) and P-waves’ features could potentiate the understanding of AF mechanisms. Five-minute surface lead II and bipolar CS recordings before, during, and after CA were acquired from 40 paroxysmal AF patients. Features related to duration, amplitude, and heart-rate variability of atrial activations were evaluated. Heart-rate adjustment (HRA) was applied. Correlations between each P-wave and CS local activation wave (LAW) feature were computed with cross-quadratic sample entropy (CQSE), Pearson correlation (PC), and linear regression (LR) with 10-fold cross-validation. The effect of CA between different ablation steps was compared with PC. Linear correlations: poor to mediocre before HRA for analysis at each P-wave/LAW (PC: max. +18.36%, p = 0.0017, LR: max. +5.33%, p = 0.0002) and comparison between two ablation steps (max. +54.07%, p = 0.0205). HRA significantly enhanced these relationships, especially in duration (P-wave/LAW: +43.82% to +69.91%, p < 0.0001 for PC and +18.97% to +47.25%, p < 0.0001 for LR, CA effect: +53.90% to +85.72%, p < 0.0210). CQSE reported negligent correlations (0.6–1.2). Direct analysis of CS features is unreliable to evaluate atrial substrate modification due to CA. HRA substantially solves this problem, potentiating correlation with P-wave features. Hence, its application is highly recommended.
- 1 June 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (6) , 176
Open AccessThe Relevance of Heart Rate Fluctuation When Evaluating Atrial Substrate Electrical Features in Catheter Ablation of Paroxysmal Atrial Fibrillation
Coronary sinus (CS) catheterization is critical during catheter ablation (CA) of atrial fibrillation (AF). However, the association of CS electrical activity with atrial substrate modification has been barely investigated and mostly limited to analyses during AF. In sinus rhythm (SR), atrial substrate modification is principally assessed at a global level through P-wave analysis. Cross-correlating CS electrograms (EGMs) and P-waves’ features could potentiate the understanding of AF mechanisms. Five-minute surface lead II and bipolar CS recordings before, during, and after CA were acquired from 40 paroxysmal AF patients. Features related to duration, amplitude, and heart-rate variability of atrial activations were evaluated. Heart-rate adjustment (HRA) was applied. Correlations between each P-wave and CS local activation wave (LAW) feature were computed with cross-quadratic sample entropy (CQSE), Pearson correlation (PC), and linear regression (LR) with 10-fold cross-validation. The effect of CA between different ablation steps was compared with PC. Linear correlations: poor to mediocre before HRA for analysis at each P-wave/LAW (PC: max. +18.36%, p = 0.0017, LR: max. +5.33%, p = 0.0002) and comparison between two ablation steps (max. +54.07%, p = 0.0205). HRA significantly enhanced these relationships, especially in duration (P-wave/LAW: +43.82% to +69.91%, p < 0.0001 for PC and +18.97% to +47.25%, p < 0.0001 for LR, CA effect: +53.90% to +85.72%, p < 0.0210). CQSE reported negligent correlations (0.6–1.2). Direct analysis of CS features is unreliable to evaluate atrial substrate modification due to CA. HRA substantially solves this problem, potentiating correlation with P-wave features. Hence, its application is highly recommended.
- Open Access
- 1 May 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (5) , 289
The Relevance of Calibration in Machine Learning-Based Hypertension Risk Assessment Combining Photoplethysmography and Electrocardiography
The detection of hypertension (HT) is of great importance for the early diagnosis of cardiovascular diseases (CVDs), as subjects with high blood pressure (BP) are asymptomatic until advanced stages of the disease. The present study proposes a classification model to discriminate between normotensive (NTS) and hypertensive (HTS) subjects employing electrocardiographic (ECG) and photoplethysmographic (PPG) recordings as an alternative to traditional cuff-based methods. A total of 913 ECG, PPG and BP recordings from 69 subjects were analyzed. Then, signal preprocessing, fiducial points extraction and feature selection were performed, providing 17 discriminatory features, such as pulse arrival and transit times, that fed machine-learning-based classifiers. The main innovation proposed in this research uncovers the relevance of previous calibration to obtain accurate HT risk assessment. This aspect has been assessed using both close and distant time test measurements with respect to calibration. The k-nearest neighbors-classifier provided the best outcomes with an accuracy for new subjects before calibration of 51.48%. The inclusion of just one calibration measurement into the model improved classification accuracy by 30%, reaching gradually more than 96% with more than six calibration measurements. Accuracy decreased with distance to calibration, but remained outstanding even days after calibration. Thus, the use of PPG and ECG recordings combined with previous subject calibration can significantly improve discrimination between NTS and HTS individuals. This strategy could be implemented in wearable devices for HT risk assessment as well as to prevent CVDs.
- 1 May 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (5) , 289
Open AccessThe Relevance of Calibration in Machine Learning-Based Hypertension Risk Assessment Combining Photoplethysmography and Electrocardiography
The detection of hypertension (HT) is of great importance for the early diagnosis of cardiovascular diseases (CVDs), as subjects with high blood pressure (BP) are asymptomatic until advanced stages of the disease. The present study proposes a classification model to discriminate between normotensive (NTS) and hypertensive (HTS) subjects employing electrocardiographic (ECG) and photoplethysmographic (PPG) recordings as an alternative to traditional cuff-based methods. A total of 913 ECG, PPG and BP recordings from 69 subjects were analyzed. Then, signal preprocessing, fiducial points extraction and feature selection were performed, providing 17 discriminatory features, such as pulse arrival and transit times, that fed machine-learning-based classifiers. The main innovation proposed in this research uncovers the relevance of previous calibration to obtain accurate HT risk assessment. This aspect has been assessed using both close and distant time test measurements with respect to calibration. The k-nearest neighbors-classifier provided the best outcomes with an accuracy for new subjects before calibration of 51.48%. The inclusion of just one calibration measurement into the model improved classification accuracy by 30%, reaching gradually more than 96% with more than six calibration measurements. Accuracy decreased with distance to calibration, but remained outstanding even days after calibration. Thus, the use of PPG and ECG recordings combined with previous subject calibration can significantly improve discrimination between NTS and HTS individuals. This strategy could be implemented in wearable devices for HT risk assessment as well as to prevent CVDs.