Mitsutoshi Takaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mitsutoshi Takaya has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
Katsuhiko Sawatari
National Institute of Industrial Health
1 shared publication- Naoko Inoue
Work Environment Research Group, National Institute of Occupational Safety and Health, Japan (JNIOSH), Kawasaki 214-8585, Japan
1 shared publication
Latest Publications
- Open Access
- 13 January 2022
- Published by Oxford University Press (OUP) in Journal of Occupational Health
- Vol. 64 (1) , e12333
Screening check test to confirm the relative reactivity and applicability of 2,4-dinitrophenylhydrazine impregnated-filters for formaldehyde on other compounds
Objectives: A simple check test method was designed to confirm whether a 2,4-dinitrophenylhydrazine (DNPH) filter for formaldehyde can be used to measure other compounds. Methods: Sample mixtures containing the same concentrations of formaldehyde, acetaldehyde, and acetone were spiked to the DNPH-filter, extracted, and then measured using high performance liquid chromatography with photodiode array detector (HPLC-PDA). The amounts of DNPH-derivatives versus the amounts of spiked samples were then plotted. Results: When the amount of DNPH << the total amount of spiked samples, the amount of DNPH-derivatives was formaldehyde > acetaldehyde >> acetone. This order corresponded to the relative rate constants for the reaction. Therefore, this study confirmed that acetone was not collected at the formaldehyde sampling rate. Conclusions: This check test easily measured the reaction rate order and can be used as a simple test to determine whether other samples can be measured by the analytical methods used for the specified sample.
- 13 January 2022
- Published by Oxford University Press (OUP) in Journal of Occupational Health
- Vol. 64 (1) , e12333
Open AccessScreening check test to confirm the relative reactivity and applicability of 2,4-dinitrophenylhydrazine impregnated-filters for formaldehyde on other compounds
Objectives: A simple check test method was designed to confirm whether a 2,4-dinitrophenylhydrazine (DNPH) filter for formaldehyde can be used to measure other compounds. Methods: Sample mixtures containing the same concentrations of formaldehyde, acetaldehyde, and acetone were spiked to the DNPH-filter, extracted, and then measured using high performance liquid chromatography with photodiode array detector (HPLC-PDA). The amounts of DNPH-derivatives versus the amounts of spiked samples were then plotted. Results: When the amount of DNPH << the total amount of spiked samples, the amount of DNPH-derivatives was formaldehyde > acetaldehyde >> acetone. This order corresponded to the relative rate constants for the reaction. Therefore, this study confirmed that acetone was not collected at the formaldehyde sampling rate. Conclusions: This check test easily measured the reaction rate order and can be used as a simple test to determine whether other samples can be measured by the analytical methods used for the specified sample.
- Open Access
- 1 January 1994
- Published by National Institute of Industrial Health in Industrial Health
- Vol. 32 (3) , 165-178
Speciation of Vanadium(IV) and Vanadium(V) Using Ion-exchange Chromatography and ICP-AES.
A speciation method for vanadium(IV) and vanadium(V) is presented that uses a combination of HPLC and ICP-AES. In this method, 1 mM HNO3 solution and 100 mM HNO3 solution were applied in sequence as eluent. A vanadium(IV) and vanadium(V) mixture was injected into a HPLC anion-exchange column; and vanadium(IV) cation was then eluted by 1 mM HNO3, while vanadium(V) oxoacid anion was trapped on the column. After this separation, vanadium(V) was eluted as a cation from the column by 100 mM HNO3. Vanadium was detected by ICP-AES. In this separation, about 15% of vanadium(V) interfered with vanadium(IV), and trace vanadium(IV) interfered with vanadium(V). This interference could be estimated by simple calculation based on standard observations, and the speciation of vanadium(IV) and vanadium(V) was performed. The lower determination limit was 1 microgram/mL, which is insufficient to speciate vanadium sampled by conventional sampling methods in a working environment. However, impurity of the other valent vanadium species in a vanadium(V) reagent can be determined by the present method, which should be valuable in precisely assessing the toxicities of vanadium species.
- 1 January 1994
- Published by National Institute of Industrial Health in Industrial Health
- Vol. 32 (3) , 165-178
Open AccessSpeciation of Vanadium(IV) and Vanadium(V) Using Ion-exchange Chromatography and ICP-AES.
A speciation method for vanadium(IV) and vanadium(V) is presented that uses a combination of HPLC and ICP-AES. In this method, 1 mM HNO3 solution and 100 mM HNO3 solution were applied in sequence as eluent. A vanadium(IV) and vanadium(V) mixture was injected into a HPLC anion-exchange column; and vanadium(IV) cation was then eluted by 1 mM HNO3, while vanadium(V) oxoacid anion was trapped on the column. After this separation, vanadium(V) was eluted as a cation from the column by 100 mM HNO3. Vanadium was detected by ICP-AES. In this separation, about 15% of vanadium(V) interfered with vanadium(IV), and trace vanadium(IV) interfered with vanadium(V). This interference could be estimated by simple calculation based on standard observations, and the speciation of vanadium(IV) and vanadium(V) was performed. The lower determination limit was 1 microgram/mL, which is insufficient to speciate vanadium sampled by conventional sampling methods in a working environment. However, impurity of the other valent vanadium species in a vanadium(V) reagent can be determined by the present method, which should be valuable in precisely assessing the toxicities of vanadium species.