Simone Moroni
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Simone Moroni has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Alejandro Fernández-Gibello
Clínica Vitruvio, C/María de Guzmán 47, 28003 Madrid, Spain
4 shared publications - Alfonso Martínez-Nova
Department of Nursing, University of Extremadura, 10600 Plasencia, Spain
4 shared publications - Felice Galluccio
Fisiotech Lab Studio, Rheumatology and Pain Management, 50136 Firenze, Italy
4 shared publications - Gabriel Camuñas-Nieves
Clínica Vitruvio, C/María de Guzmán 47, 28003 Madrid, Spain
4 shared publications - Mario Fajardo Perez
Ultradissection Group. Madrid (Spain), Spain
4 shared publications - Francisco Martínez-Pérez
Clínica Vitruvio, C/ María de Guzmán 47, 28003 Madrid, Spain
2 shared publications
Latest Publications
- Open Access
Anatomical Validation of a Selective Anesthetic Block Test to Differentiate Morton’s Neuroma from Mechanical Metatarsalgia
Background and Objectives: The anesthetic nerve block test is a surgical technique that can assist in the differential diagnosis of forefoot pain. The MTP joint, enclosed by its capsule, may act as a sealed cavity with predictable contrast dispersion, whereas the IM space, lacking clear boundaries and containing bursae and the plantar digital nerve, favors diffuse spread. Due to the high rate of false positives in suspected cases of Morton’s neuroma with the anesthetic block current procedure in the intermetatarsal space, the aim of this study was to propose an alternative to the current procedure. Material and Methods: Six fresh cadaveric feet were used. Under ultrasound guidance, the 2nd–4th MTP joints received stepwise intra-articular injections of radiopaque contrast. The third common digital nerve was injected within the third intermetatarsal space. Standard radiographs were obtained to assess distribution and proximal spread. Results: A volume of 0.3 mL was sufficient to fully reach the intra-articular cavity and potentially induce effective localized anesthesia. When the third common digital plantar nerve was injected in an anatomically healthy region, the contrast medium showed a proximal diffusion pattern extending up to the mid-diaphyseal level of the third and fourth metatarsal bones. On radiographs, the intra-articular infiltration lines appear sharply demarcated, supporting the interpretation of the metatarsophalangeal joint as a sealed compartment. Conclusions: Low intra-articular anesthetic volumes may yield targeted effects, while Morton’s neuroma injections spread proximally, risking loss of diagnostic specificity; this technique may improve decision-making accuracy and reduce failures.
Open AccessAnatomical Validation of a Selective Anesthetic Block Test to Differentiate Morton’s Neuroma from Mechanical Metatarsalgia
Background and Objectives: The anesthetic nerve block test is a surgical technique that can assist in the differential diagnosis of forefoot pain. The MTP joint, enclosed by its capsule, may act as a sealed cavity with predictable contrast dispersion, whereas the IM space, lacking clear boundaries and containing bursae and the plantar digital nerve, favors diffuse spread. Due to the high rate of false positives in suspected cases of Morton’s neuroma with the anesthetic block current procedure in the intermetatarsal space, the aim of this study was to propose an alternative to the current procedure. Material and Methods: Six fresh cadaveric feet were used. Under ultrasound guidance, the 2nd–4th MTP joints received stepwise intra-articular injections of radiopaque contrast. The third common digital nerve was injected within the third intermetatarsal space. Standard radiographs were obtained to assess distribution and proximal spread. Results: A volume of 0.3 mL was sufficient to fully reach the intra-articular cavity and potentially induce effective localized anesthesia. When the third common digital plantar nerve was injected in an anatomically healthy region, the contrast medium showed a proximal diffusion pattern extending up to the mid-diaphyseal level of the third and fourth metatarsal bones. On radiographs, the intra-articular infiltration lines appear sharply demarcated, supporting the interpretation of the metatarsophalangeal joint as a sealed compartment. Conclusions: Low intra-articular anesthetic volumes may yield targeted effects, while Morton’s neuroma injections spread proximally, risking loss of diagnostic specificity; this technique may improve decision-making accuracy and reduce failures.
- Open Access
- 30 July 2025
- Published by MDPI AG in Preprints.org
Anesthetic Suppression Test to Differentiate Morton’s Neuroma from Mechanical Metatarsalgia: A New Diagnostic Tool?
Background and Objectives: The anesthetic nerve block test is a surgical technique that can assist in the differential diagnosis of forefoot pain, particularly in cases where clinical presentation is complex and diagnostic uncertainty is common. So, the aim of this study was to propose an alternative to the current procedure, which is known to produce a high rate of false positives in suspected cases of Morton’s neuroma. Material and methods: An experimental anatomical study was conducted on six fresh cadaveric feet. Under ultrasound guidance, the second, third, and fourth metatarsophalangeal joints were infiltrated with progressively increasing volumes of radiopaque contrast medium. Additionally, the third common digital nerve was injected in a healthy segment of the nerve within the third intermetatarsal space. Standard radiographs were then obtained to evaluate the distribution and proximal spread of the injected fluid. Results: A volume of 0.3 ml was sufficient to fully reach the intra-articular cavity and induce effective localized anesthesia. When the third common digital plantar nerve was injected in an anatomically healthy region, the contrast medium showed a proximal diffusion pattern extending up to the mid-diaphyseal level of the third and fourth metatarsal bones. Conclusions: Low intra-articular volumes of anesthetic may be sufficient to achieve a targeted clinical response, whereas injection into a Morton’s neuroma leads to a broader proximal spread, potentially anesthetizing adjacent anatomical structures and thus reducing diagnostic specificity. This refined technique may enhance the accuracy of therapeutic decision-making and reduce treatment failures in patients with suspected Morton’s neuroma.
- 30 July 2025
- Published by MDPI AG in Preprints.org
Open AccessAnesthetic Suppression Test to Differentiate Morton’s Neuroma from Mechanical Metatarsalgia: A New Diagnostic Tool?
Background and Objectives: The anesthetic nerve block test is a surgical technique that can assist in the differential diagnosis of forefoot pain, particularly in cases where clinical presentation is complex and diagnostic uncertainty is common. So, the aim of this study was to propose an alternative to the current procedure, which is known to produce a high rate of false positives in suspected cases of Morton’s neuroma. Material and methods: An experimental anatomical study was conducted on six fresh cadaveric feet. Under ultrasound guidance, the second, third, and fourth metatarsophalangeal joints were infiltrated with progressively increasing volumes of radiopaque contrast medium. Additionally, the third common digital nerve was injected in a healthy segment of the nerve within the third intermetatarsal space. Standard radiographs were then obtained to evaluate the distribution and proximal spread of the injected fluid. Results: A volume of 0.3 ml was sufficient to fully reach the intra-articular cavity and induce effective localized anesthesia. When the third common digital plantar nerve was injected in an anatomically healthy region, the contrast medium showed a proximal diffusion pattern extending up to the mid-diaphyseal level of the third and fourth metatarsal bones. Conclusions: Low intra-articular volumes of anesthetic may be sufficient to achieve a targeted clinical response, whereas injection into a Morton’s neuroma leads to a broader proximal spread, potentially anesthetizing adjacent anatomical structures and thus reducing diagnostic specificity. This refined technique may enhance the accuracy of therapeutic decision-making and reduce treatment failures in patients with suspected Morton’s neuroma.
- Open Access
- 28 July 2025
- Published by MDPI AG in Healthcare
- Vol. 13 (15) , 1838
Continuous Radiofrequency for Morton’s Neuroma: Is There Complete Ablation? A Preliminary Report
Background and Objectives: Morton’s neuroma is a painful foot condition that can be treated with continuous radiofrequency. However, its efficacy is not always optimal, with failure rates of 15–20%. It has been suggested that these failures may be due to incomplete nerve ablation, allowing for nerve regeneration and persistent pain. So, the aim of this study was to assess the histological effects of continuous radiofrequency on the nerves affected by Morton’s neuroma. Materials and Methods: The effect of continuous radiofrequency was evaluated in two patients with Morton’s neuroma, which required open surgery excision. In both cases, radiofrequency with a standard protocol was applied ex vivo, following the surgical excision of the neuroma. A TLG10 RF generator (90 °C, 90 s) with a monopolar needle with a 0.5 cm active tip was used. Subsequently, the samples were histologically analyzed to determine the degree of nerve ablation. Results: Histological analysis showed homogeneous focal necrosis in both cases, with lesion depths of 2.4 mm and 3.18 mm. However, areas of intact nerve tissue were identified at the periphery of the neuroma, suggesting incomplete ablation. Conclusions: The findings indicate that continuous radiofrequency does not guarantee total nerve ablation, which could explain recurrence in some cases. Intraoperative neurophysiological monitoring could be key to optimizing the procedure, ensuring complete interruption of nerve conduction and improving treatment efficacy.
- 28 July 2025
- Published by MDPI AG in Healthcare
- Vol. 13 (15) , 1838
Open AccessContinuous Radiofrequency for Morton’s Neuroma: Is There Complete Ablation? A Preliminary Report
Background and Objectives: Morton’s neuroma is a painful foot condition that can be treated with continuous radiofrequency. However, its efficacy is not always optimal, with failure rates of 15–20%. It has been suggested that these failures may be due to incomplete nerve ablation, allowing for nerve regeneration and persistent pain. So, the aim of this study was to assess the histological effects of continuous radiofrequency on the nerves affected by Morton’s neuroma. Materials and Methods: The effect of continuous radiofrequency was evaluated in two patients with Morton’s neuroma, which required open surgery excision. In both cases, radiofrequency with a standard protocol was applied ex vivo, following the surgical excision of the neuroma. A TLG10 RF generator (90 °C, 90 s) with a monopolar needle with a 0.5 cm active tip was used. Subsequently, the samples were histologically analyzed to determine the degree of nerve ablation. Results: Histological analysis showed homogeneous focal necrosis in both cases, with lesion depths of 2.4 mm and 3.18 mm. However, areas of intact nerve tissue were identified at the periphery of the neuroma, suggesting incomplete ablation. Conclusions: The findings indicate that continuous radiofrequency does not guarantee total nerve ablation, which could explain recurrence in some cases. Intraoperative neurophysiological monitoring could be key to optimizing the procedure, ensuring complete interruption of nerve conduction and improving treatment efficacy.
- Open Access
- 28 May 2025
- Published by MDPI AG in Preprints.org
Continuous Radiofrequency for Morton's Neuroma: Is There a Complete Ablation? A Preliminary Report
Background and Objectives: Morton's neuroma is a painful foot condition that can be treated with continuous radiofrequency. However, its efficacy is not always optimal, with failure rates of 15-20%. It has been suggested that these failures may be due to incomplete nerve ablation, allowing for nerve regeneration and persistent pain. So, the aim of this study was to assess the histological effects on the nerve of continuous radiofrequency on Morton's neuroma. Materials and Methods: The effect of continuous radiofrequency was evaluated in two patients with Morton's neuroma, which required open surgery excision. In both cases, radiofrequency with an standard protocol was applied ex vivo, following the surgical excision of the neuroma. A Neurotherm NT1100 generator (90°C, 90s) with a monopolar needle with a 0.5 cm active tip was used. Subsequently, the samples were histologically analyzed to determine the degree of nerve ablation. Results: Histological analysis showed homogeneous focal necrosis in both cases, with lesion depths of 2.4 mm and 3.18 mm. However, areas of intact nerve tissue were identified at the periphery of the neuroma, suggesting incomplete ablation. Conclusions: The findings indicate that continuous radiofrequency does not guarantee total nerve ablation, which could explain recurrence in some cases. Intraoperative neurophysiological monitoring could be key to optimizing the procedure, ensuring complete interruption of nerve conduction and improving treatment efficacy.
- 28 May 2025
- Published by MDPI AG in Preprints.org
Open AccessContinuous Radiofrequency for Morton's Neuroma: Is There a Complete Ablation? A Preliminary Report
Background and Objectives: Morton's neuroma is a painful foot condition that can be treated with continuous radiofrequency. However, its efficacy is not always optimal, with failure rates of 15-20%. It has been suggested that these failures may be due to incomplete nerve ablation, allowing for nerve regeneration and persistent pain. So, the aim of this study was to assess the histological effects on the nerve of continuous radiofrequency on Morton's neuroma. Materials and Methods: The effect of continuous radiofrequency was evaluated in two patients with Morton's neuroma, which required open surgery excision. In both cases, radiofrequency with an standard protocol was applied ex vivo, following the surgical excision of the neuroma. A Neurotherm NT1100 generator (90°C, 90s) with a monopolar needle with a 0.5 cm active tip was used. Subsequently, the samples were histologically analyzed to determine the degree of nerve ablation. Results: Histological analysis showed homogeneous focal necrosis in both cases, with lesion depths of 2.4 mm and 3.18 mm. However, areas of intact nerve tissue were identified at the periphery of the neuroma, suggesting incomplete ablation. Conclusions: The findings indicate that continuous radiofrequency does not guarantee total nerve ablation, which could explain recurrence in some cases. Intraoperative neurophysiological monitoring could be key to optimizing the procedure, ensuring complete interruption of nerve conduction and improving treatment efficacy.
- Open Access
- 1 June 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (6) , 1367
Study of the Anatomical Association between Morton’s Neuroma and the Space Inferior to the Deep Transverse Metatarsal Ligament Using Ultrasound
Morton’s neuroma (MN) is a common condition in clinical practice. The compressive etiology is the most accepted, in which compression occurs in the tunnel formed by the adjacent metatarsals, the deep transverse metatarsal ligament (DTML) and the plantar skin. Ultrasound (US) is a reliable method of study. The presence of insufficient space under the DTML may be related to the appearance of MN. Objectives: To verify the relationship between MN and the space under the DTML between the metatarsal heads of the third (M3) and the fourth (M4) metatarsals using US. Methods: This is a cross-sectional epidemiological study. The research study using the ultrasound (US) technique was carried out on 200 feet belonging to 100 patients aged 18 to 65 of both sexes, with a control group formed by 62 patients and a study group formed by 38 patients diagnosed with MN. Results: The presence of MN and the factors associated with it were studied in 100 patients using ultrasound (US). The assessment and comparison with US of the space inferior to the DTML between M3 and M4 in control groups and patients with MN show that patients with MN have a smaller size in the variable “h” (height or distance DTML-plantar skin), in the variable “b” (base or intermetatarsal distance M3 and M4) and in the variable “s” (surface of the parallelogram “h” × “b”). The predictors of MN are a decrease in dimension “b” and an increase in weight. Sitting in an office chair and the use of a bicycle, due to equinus, have an influence on the space below the DTML, reducing it and promoting the appearance of MN. Conclusions: The two US measurements (“h” and “b”) in the space below the DTML are smaller in patients with MN than in the asymptomatic group. A shorter distance between M3 and M4, and an increase in BMI are predictors of MN.
- 1 June 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (6) , 1367
Open AccessStudy of the Anatomical Association between Morton’s Neuroma and the Space Inferior to the Deep Transverse Metatarsal Ligament Using Ultrasound
Morton’s neuroma (MN) is a common condition in clinical practice. The compressive etiology is the most accepted, in which compression occurs in the tunnel formed by the adjacent metatarsals, the deep transverse metatarsal ligament (DTML) and the plantar skin. Ultrasound (US) is a reliable method of study. The presence of insufficient space under the DTML may be related to the appearance of MN. Objectives: To verify the relationship between MN and the space under the DTML between the metatarsal heads of the third (M3) and the fourth (M4) metatarsals using US. Methods: This is a cross-sectional epidemiological study. The research study using the ultrasound (US) technique was carried out on 200 feet belonging to 100 patients aged 18 to 65 of both sexes, with a control group formed by 62 patients and a study group formed by 38 patients diagnosed with MN. Results: The presence of MN and the factors associated with it were studied in 100 patients using ultrasound (US). The assessment and comparison with US of the space inferior to the DTML between M3 and M4 in control groups and patients with MN show that patients with MN have a smaller size in the variable “h” (height or distance DTML-plantar skin), in the variable “b” (base or intermetatarsal distance M3 and M4) and in the variable “s” (surface of the parallelogram “h” × “b”). The predictors of MN are a decrease in dimension “b” and an increase in weight. Sitting in an office chair and the use of a bicycle, due to equinus, have an influence on the space below the DTML, reducing it and promoting the appearance of MN. Conclusions: The two US measurements (“h” and “b”) in the space below the DTML are smaller in patients with MN than in the asymptomatic group. A shorter distance between M3 and M4, and an increase in BMI are predictors of MN.
- Open Access
- 2 May 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (9) , 2553
Novel Ultrasound Anatomical Measurement of the Deep Transverse Metatarsal Ligament: An Intra-Rater Reliability and Inter-Rater Concordance Study
Insufficient space below the Deep Transverse Metatarsal Ligament (DTML) could be an etiological factor for Morton’s Neuroma (MN). To date, there is a lack of studies measuring the space below the DTML. For this reason, this study assesses the intra- and inter-rater concordance and reproducibility of measurements of the space below the DTML between the third and the fourth metatarsal heads (M3 and M4) using ultrasound imaging to assess and verify the reliability and reproducibility of measurements of the space under the DTML. Forty feet from twenty patients were examined using ultrasound by three trained evaluators at two different times. The two measurements taken on each foot were: base (b)—distance between M3 and M4, and height (h)—distance between the DTML and the plantar skin surface. This was a quantitative, observational, analytical study. The concordance rate between observers for measurements of height and base were 98.5% and 99.5%, respectively. The mean area obtained of the space was 54.6 mm2 and 57.2 mm2 for both the left and right foot (p > 0.05). Reproducibility over time calculated in pre- and post-measurements showed an intraclass correlation coefficient of 1.00 (95%CI: 0.99–1.00), which leads us to conclude that the measurements are perfectly reproducible. Both measurements (height and base) of the space under the DTML, performed by ultrasound, are reliable and reproducible.
- 2 May 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (9) , 2553
Open AccessNovel Ultrasound Anatomical Measurement of the Deep Transverse Metatarsal Ligament: An Intra-Rater Reliability and Inter-Rater Concordance Study
Insufficient space below the Deep Transverse Metatarsal Ligament (DTML) could be an etiological factor for Morton’s Neuroma (MN). To date, there is a lack of studies measuring the space below the DTML. For this reason, this study assesses the intra- and inter-rater concordance and reproducibility of measurements of the space below the DTML between the third and the fourth metatarsal heads (M3 and M4) using ultrasound imaging to assess and verify the reliability and reproducibility of measurements of the space under the DTML. Forty feet from twenty patients were examined using ultrasound by three trained evaluators at two different times. The two measurements taken on each foot were: base (b)—distance between M3 and M4, and height (h)—distance between the DTML and the plantar skin surface. This was a quantitative, observational, analytical study. The concordance rate between observers for measurements of height and base were 98.5% and 99.5%, respectively. The mean area obtained of the space was 54.6 mm2 and 57.2 mm2 for both the left and right foot (p > 0.05). Reproducibility over time calculated in pre- and post-measurements showed an intraclass correlation coefficient of 1.00 (95%CI: 0.99–1.00), which leads us to conclude that the measurements are perfectly reproducible. Both measurements (height and base) of the space under the DTML, performed by ultrasound, are reliable and reproducible.