Francesco Fersini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Francesco Fersini has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Giuseppe Vicidomini
Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
5 shared publications - Alessandro Zunino
Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
4 shared publications - Alberto Diaspro
Istituto Italiano di Tecnologia
2 shared publications - Colin James Richard Sheppard
School of Optometry and Vision Science, UNSW Medicine, Sydney, NSW 2052, Australia
2 shared publications Giorgio Tortarolo
Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
2 shared publications- Mattia Donato
Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
2 shared publications
Latest Publications
- Open Access
An open, integrated platform for multiplexed bioluminescence microscopy
We report an imaging package to democratize all-in-one bioluminescence and fluorescence microscopy. The platform comprises three tools: PhasorViewer, a visualization suite to design experiments and identify optimal probe combinations; PhasorScope, an open-source, cost-effective microscopy framework to upgrade conventional microscopes; and PhasorAnalysis, a dedicated, user-friendly analysis pipeline to quantify phasor imaging data. We demonstrate the utility of the platform for multiplexed, simultaneous fluorescence and bioluminescence imaging with readily accessible optical reporters.
Open AccessAn open, integrated platform for multiplexed bioluminescence microscopy
We report an imaging package to democratize all-in-one bioluminescence and fluorescence microscopy. The platform comprises three tools: PhasorViewer, a visualization suite to design experiments and identify optimal probe combinations; PhasorScope, an open-source, cost-effective microscopy framework to upgrade conventional microscopes; and PhasorAnalysis, a dedicated, user-friendly analysis pipeline to quantify phasor imaging data. We demonstrate the utility of the platform for multiplexed, simultaneous fluorescence and bioluminescence imaging with readily accessible optical reporters.
- Open Access
Wavefront estimation through structured detection in laser scanning microscopy
Laser scanning microscopy (LSM) is the base of numerous advanced imaging techniques, including confocal laser scanning microscopy (CLSM), a widely used tool in life sciences research. However, its effective resolution is often compromised by optical aberrations, a common challenge in all optical systems. While adaptive optics (AO) can correct these aberrations, current methods face significant limitations: Aberration estimation, which is central to any AO approach, typically requires specialized hardware or prolonged sample exposure, rendering these methods sample-invasive, and less user-friendly. In this study, we introduce a simple and efficient AO approach for CLSM systems equipped with a detector array – the same of super-resolved image-scanning microscopy – and an AO element for beam shaping. We demonstrate that imaging datasets acquired with a detector array inherently encode aberration information. Leveraging this property, we developed a custom convolutional neural network capable of decoding aberrations, up to the 11 th Zernike coefficient, directly from a single acquisition. This method enables a new generation of AO implementations for LSM, offering an accessible solution that minimizes sample stress while achieving high-resolution, and aberration-free imaging.
Open AccessWavefront estimation through structured detection in laser scanning microscopy
Laser scanning microscopy (LSM) is the base of numerous advanced imaging techniques, including confocal laser scanning microscopy (CLSM), a widely used tool in life sciences research. However, its effective resolution is often compromised by optical aberrations, a common challenge in all optical systems. While adaptive optics (AO) can correct these aberrations, current methods face significant limitations: Aberration estimation, which is central to any AO approach, typically requires specialized hardware or prolonged sample exposure, rendering these methods sample-invasive, and less user-friendly. In this study, we introduce a simple and efficient AO approach for CLSM systems equipped with a detector array – the same of super-resolved image-scanning microscopy – and an AO element for beam shaping. We demonstrate that imaging datasets acquired with a detector array inherently encode aberration information. Leveraging this property, we developed a custom convolutional neural network capable of decoding aberrations, up to the 11 th Zernike coefficient, directly from a single acquisition. This method enables a new generation of AO implementations for LSM, offering an accessible solution that minimizes sample stress while achieving high-resolution, and aberration-free imaging.
- 18 May 2023
- Published by Springer Nature in Nature Photonics
- Vol. 17 (6) , 457-458
Open-source tools enable accessible and advanced image scanning microscopy data analysis
- 18 May 2023
- Published by Springer Nature in Nature Photonics
- Vol. 17 (6) , 457-458
Open-source tools enable accessible and advanced image scanning microscopy data analysis
- Open Access
- 13 December 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-14
Focus image scanning microscopy for sharp and gentle super-resolved microscopy
To date, the feasibility of super-resolution microscopy for imaging live and thick samples is still limited. Stimulated emission depletion (STED) microscopy requires high-intensity illumination to achieve sub-diffraction resolution, potentially introducing photodamage to live specimens. Moreover, the out-of-focus background may degrade the signal stemming from the focal plane. Here, we propose a new method to mitigate these limitations without drawbacks. First, we enhance a STED microscope with a detector array, enabling image scanning microscopy (ISM). Therefore, we implement STED-ISM, a method that exploits the working principle of ISM to reduce the depletion intensity and achieve a target resolution. Later, we develop Focus-ISM, a strategy to improve the optical sectioning and remove the background of any ISM-based imaging technique, with or without a STED beam. The proposed approach requires minimal architectural changes to a conventional microscope but provides substantial advantages for live and thick sample imaging.
- 13 December 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-14
Open AccessFocus image scanning microscopy for sharp and gentle super-resolved microscopy
To date, the feasibility of super-resolution microscopy for imaging live and thick samples is still limited. Stimulated emission depletion (STED) microscopy requires high-intensity illumination to achieve sub-diffraction resolution, potentially introducing photodamage to live specimens. Moreover, the out-of-focus background may degrade the signal stemming from the focal plane. Here, we propose a new method to mitigate these limitations without drawbacks. First, we enhance a STED microscope with a detector array, enabling image scanning microscopy (ISM). Therefore, we implement STED-ISM, a method that exploits the working principle of ISM to reduce the depletion intensity and achieve a target resolution. Later, we develop Focus-ISM, a strategy to improve the optical sectioning and remove the background of any ISM-based imaging technique, with or without a STED beam. The proposed approach requires minimal architectural changes to a conventional microscope but provides substantial advantages for live and thick sample imaging.
- Open Access
- 1 December 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-14
The BrightEyes-TTM as an open-source time-tagging module for democratising single-photon microscopy
Fluorescence laser-scanning microscopy (LSM) is experiencing a revolution thanks to new single-photon (SP) array detectors, which give access to an entirely new set of single-photon information. Together with the blooming of new SP LSM techniques and the development of tailored SP array detectors, there is a growing need for (i) DAQ systems capable of handling the high-throughput and high-resolution photon information generated by these detectors, and (ii) incorporating these DAQ protocols in existing fluorescence LSMs. We developed an open-source, low-cost, multi-channel time-tagging module (TTM) based on a field-programmable gate array that can tag in parallel multiple single-photon events, with 30 ps precision, and multiple synchronisation events, with 4 ns precision. We use the TTM to demonstrate live-cell super-resolved fluorescence lifetime image scanning microscopy and fluorescence lifetime fluctuation spectroscopy. We expect that our BrightEyes-TTM will support the microscopy community in spreading SP-LSM in many life science laboratories.
- 1 December 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-14
Open AccessThe BrightEyes-TTM as an open-source time-tagging module for democratising single-photon microscopy
Fluorescence laser-scanning microscopy (LSM) is experiencing a revolution thanks to new single-photon (SP) array detectors, which give access to an entirely new set of single-photon information. Together with the blooming of new SP LSM techniques and the development of tailored SP array detectors, there is a growing need for (i) DAQ systems capable of handling the high-throughput and high-resolution photon information generated by these detectors, and (ii) incorporating these DAQ protocols in existing fluorescence LSMs. We developed an open-source, low-cost, multi-channel time-tagging module (TTM) based on a field-programmable gate array that can tag in parallel multiple single-photon events, with 30 ps precision, and multiple synchronisation events, with 4 ns precision. We use the TTM to demonstrate live-cell super-resolved fluorescence lifetime image scanning microscopy and fluorescence lifetime fluctuation spectroscopy. We expect that our BrightEyes-TTM will support the microscopy community in spreading SP-LSM in many life science laboratories.
- Open Access
Focus-ISM for Sharp and Gentle Super-Resolved Microscopy
Super-resolution microscopy is routinely used for fixed and thin samples, while its feasibility for imaging live and thick samples is still limited. In the case of stimulated emission depletion (STED) microscopy, the high-intensity illumination required to achieve effective sub-diffraction resolution can introduce photo-damage, thus reducing the compatibility of the technique with live-cell imaging. Moreover, the out-of-focus fluorescence background may overcome the often faint signal stemming from the focal point, thus constraining imaging to thin samples. Here, we combined STED microscopy with image-scanning microscopy (ISM) to mitigate these limitations without any practical disadvantages. We first enhanced a laser scanning microscope (LSM) by introducing a detector array, hence providing access to a set of additional spatial information that is not available with a typical single-element detector. Then, we exploited this extended dataset to implement focus-ISM, a novel method that relaxes the high-intensity requirement of STED microscopy and removes the out-of-focus background. Additionally, we generalized the focus-ISM method to conventional LSM, namely without a STED beam. The proposed approach requires minimal architectural changes compared with conventional STED microscopes but provides substantial advantages for live and thick sample imaging while maintaining all compatibility with all recent advances in STED and confocal microscopy. As such, focus-ISM represents an essential step towards a universal super-resolved LSM technique for subcellular imaging.
Open AccessFocus-ISM for Sharp and Gentle Super-Resolved Microscopy
Super-resolution microscopy is routinely used for fixed and thin samples, while its feasibility for imaging live and thick samples is still limited. In the case of stimulated emission depletion (STED) microscopy, the high-intensity illumination required to achieve effective sub-diffraction resolution can introduce photo-damage, thus reducing the compatibility of the technique with live-cell imaging. Moreover, the out-of-focus fluorescence background may overcome the often faint signal stemming from the focal point, thus constraining imaging to thin samples. Here, we combined STED microscopy with image-scanning microscopy (ISM) to mitigate these limitations without any practical disadvantages. We first enhanced a laser scanning microscope (LSM) by introducing a detector array, hence providing access to a set of additional spatial information that is not available with a typical single-element detector. Then, we exploited this extended dataset to implement focus-ISM, a novel method that relaxes the high-intensity requirement of STED microscopy and removes the out-of-focus background. Additionally, we generalized the focus-ISM method to conventional LSM, namely without a STED beam. The proposed approach requires minimal architectural changes compared with conventional STED microscopes but provides substantial advantages for live and thick sample imaging while maintaining all compatibility with all recent advances in STED and confocal microscopy. As such, focus-ISM represents an essential step towards a universal super-resolved LSM technique for subcellular imaging.