PCPierre Corvilain

Pierre Corvilain

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pierre Corvilain has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Signal space beamforming for gain- and geometry-independent interference suppression in wearable MEG

    by Maxime Ferez, Pierre Corvilain, Odile Feys, Chiara Capparini, Laureline Fourdin, Julie Bertels, Xavier De Tiège, Vincent Wens

    Optically pumped magnetometers (OPMs) for wearable magnetoencephalography (MEG) offer substantial flexibility compared to cryogenic MEG, but they also introduce new challenges related to environmental noise and movement artefacts. State-of-the-art denoising techniques such as signal space separation require not only dense OPM arrays but also the fine calibration of sensor gain and geometry. This may complicate their use in complex experimental situations involving uncooperative patients or subjects such as newborns or fetuses, where OPM positioning may be unstable or plain unknown. To address this limitation, we introduce signal space beamforming (SSB), a version of beamforming applied to sensor signals and designed to suppress interferences independently of sensor gain and geometry. We show that SSB operates via a trade-off between noise suppression and neural signal preservation that is controlled by a single soft-threshold parameter, which we calibrated using phantom measurements. We then validated the effectiveness of SSB across several datasets. Using interictal OPM-MEG recordings in epileptic patients, SSB successfully cleaned signals while preserving epileptiform discharges. Moving onto cutting-edge early neurodevelopmental OPM-MEG recordings, SSB allowed to recover auditory evoked responses in newborns and fetuses similar to previous findings but with more streamlined preprocessing and higher response amplitude in the case of the fetal data. We contend that SSB provides a pragmatic solution to exploit OPM-MEG data recorded in challenging conditions where geometry-dependent methods cannot be used, opening new frontiers for pioneering clinical and fundamental applications of the OPM technology.


  • Open Access

    Fetal magnetoencephalography based on optically pumped magnetometers

    by Pierre Corvilain, Chiara Capparini, Vincent Wens, Lauréline Fourdin, Maxime Ferez, Odile Feys, Anne Delbaere, Rosine Lejeune, Deborah Goldman, Caroline De Coninck, et al.

    The fetus in the third trimester of gestation has already the remarkable capacity to process external sensory information in utero. So far, investigations of fetal brain responses to sensory information have mostly relied on cryogenic magnetoencephalography (MEG), which is suitable to record fetal brain activity and is not much affected by layers of maternal tissues. Nevertheless, this solution is extremely expensive and limited to a couple of laboratories worldwide. In this work, we took advantage of the next generation cryogenic-free MEG, that is MEG based on optically pumped magnetometers (OPM), to develop a system that could record both fetal and newborn brain responses to auditory stimulation in a longitudinal design. Twenty-one pregnant women in their late third trimester of gestation (35-40 weeks of gestational age) were exposed to sequences of 500 Hz tones. Fetal brain activity was recorded using a wearable belt equipped with OPM sensors arranged on the women’s abdomen based on fetal head position. Results revealed that fetal OPM-MEG successfully recorded significant evoked brain responses to auditory stimuli that peaked ~300 ms post-stimulus at the group level. A similar auditory paradigm was performed with on-scalp OPM-MEG in 14 one-month-old infants, with 9 participants common to both timepoints. Infant responses showed a significant latency decrease compared to the fetal ones in terms of magnetometers; a decrease that did not reach significance level for virtual gradiometers. This work demonstrates the ability of OPM-MEG to non-invasively record fetal brain responses to external sensory stimuli. It paves the way for a wider use of fetal MEG to investigate fetal cognition and positions OPM-MEG as the most promising lifespan-compliant solution for monitoring early brain development.


  • Open Access

    Pushing the boundaries of MEG based on optically pumped magnetometers towards early human life

    by Pierre Corvilain, Vincent Wens, Mathieu Bourguignon, Chiara Capparini, Lauréline Fourdin, Maxime Ferez, Odile Feys, Xavier De Tiège, Julie Bertels

    Characterizing the early development of the human brain is critical from both fundamental and clinical perspectives. However, existing neuroimaging techniques are either not well suited to infants or have limited spatial or temporal resolution. The advent of optically pumped magnetometers (OPMs) has revolutionized magnetoencephalography (MEG) by enabling wearable and thus more naturalistic recordings while maintaining excellent sensitivity and spatiotemporal resolution. Nevertheless, its adaptation to studying neural activity in infancy poses several challenges. In this work, we present an original close-to-scalp OPM-MEG setup that successfully recorded brain responses to sounds in newborns. We exposed 1-month-old infants to continuous streams of tones and observed significant evoked responses, which peaked ~250 ms poststimulus at bilateral auditory cortices. When tones were presented at a steady fixed pace with an oddball tone every fourth tone, significant neural responses were found both at the frequency of the standard tones (3 Hz) and of the oddball tones (0.75 Hz). The latter reflects the ability of the newborn brain to detect auditory change and synchronize to regular auditory patterns. Additional analyses support the added value of triaxial OPMs to increase the number of channels on small heads. Finally, OPM-MEG responses were validated with those obtained from the same participants using an adult-sized cryogenic MEG. This study demonstrates the applicability of OPM-MEG to study early postnatal periods; a crucial step towards future OPM investigations of typical and pathological early brain development.


  • Open Access

    Pushing the boundaries of MEG based on optically pumped magnetometers towards early human life

    by Pierre Corvilain, Vincent Wens, Mathieu Bourguignon, Chiara Capparini, Lauréline Fourdin, Maxime Ferez, Odile Feys, Xavier De Tiège, Julie Bertels

    Characterizing the early development of the human brain is critical from both fundamental and clinical perspectives. However, existing neuroimaging techniques are either not well suited to infants or have limited spatial or temporal resolution. The advent of optically pumped magnetometers (OPMs) has revolutionized magnetoencephalography (MEG) by enabling wearable and thus more naturalistic recordings while maintaining excellent sensitivity and spatiotemporal resolution. Nevertheless, its adaptation to studying neural activity in infancy poses several challenges. In this work, we present an original close-to-scalp OPM-MEG setup that successfully recorded brain responses to sounds in newborns. We exposed one-month-old infants to continuous streams of tones and observed significant evoked responses, which peaked ∼250 ms poststimulus at bilateral auditory cortices. When tones were presented at a steady fixed pace with an oddball tone every fourth tone, significant neural responses were found both at the frequency of the standard tones (3 Hz) and of the oddball tones (0.75 Hz). The latter reflects the ability of the newborn brain to detect auditory change and synchronize to regular auditory patterns. Additional analyses support the added value of triaxial OPMs to increase the number of channels on small heads. Finally, OPM-MEG responses were validated with those obtained from the same participants using an adult-sized cryogenic MEG. This study demonstrates the applicability of OPM-MEG to study early postnatal periods; a crucial step towards future OPM investigations of typical and pathological early brain development.


  • Top Cited Papers

    On-Scalp Optically Pumped Magnetometers versus Cryogenic Magnetoencephalography for Diagnostic Evaluation of Epilepsy in School-aged Children

    by Odile Feys, Pierre Corvilain, Alec Aeby, Claudine Sculier, Niall Holmes, Matthew Brookes, Serge Goldman, Vincent Wens, Xavier De Tiège

    On-scalp optically pumped magnetometer-based magnetoencephalography provided a higher amplitude and signal-to-noise ratio than cryogenic magnetoencephalography, with similar localization value, for... Background Magnetoencephalography (MEG) is an established method used to detect and localize focal interictal epileptiform discharges (IEDs). Current MEG systems house hundreds of cryogenic sensors...