Evdoxia Theodorou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Evdoxia Theodorou has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Chara Tzavara
Department of Nutrition and Dietetics, School of Health Science and Education, Harokopio University of Athens, 70 El. Venizelou Ave., 17676 Athens, Greece
4 shared publications - Dimitrios Psimadas
Nuclear Medicine Laboratory, University Hospital of Larissa, University of Thessaly, 41110 Larissa, Greece
4 shared publications - George Angelidis
Nuclear Medicine Laboratory, University Hospital of Larissa, University of Thessaly, 41110 Larissa, Greece
4 shared publications - Ioannis Tsougos
Medical Physics Department, Faculty of Medicine, School of Health Sciences, University of Thessaly, 41500 Larissa, Greece
4 shared publications - Charalampos Ziangas
Nuclear Medicine Laboratory, University Hospital of Larissa, University of Thessaly, 41110 Larissa, Greece
3 shared publications - Filippos Triposkiadis
School of Medicine, European University Cyprus, Nicosia 2404, Cyprus
3 shared publications
Latest Publications
- Open Access
- 25 December 2025
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (1) , 6
Long-Term Prognostic Value in Nuclear Cardiology: Expert Scoring Combined with Automated Measurements vs. Angiographic Score
The evaluation of myocardial perfusion imaging (MPI) studies is based on the visual interpretation of the reconstructed images, while the measurements obtained through software packages may contribute to the investigation, mainly in cases of ambiguous scintigraphic findings. We aimed to investigate the long-term prognostic value of expert reading of Summed Stress Score (SSS), Summed Rest Score (SRS), and Summed Difference Score (SDS), combined with the automated measurements of these parameters, in comparison to the prognostic ability of the angiographic score for soft and hard cardiac events. The study was conducted at the Nuclear Medicine Laboratory of the University of Thessaly, in Larissa, Greece. Overall, 378 consecutive patients with known or suspected coronary artery disease (CAD) were enrolled. Automated measurements of SSS, SRS, and SDS were obtained using the Emory Cardiac Toolbox, Myovation, and Quantitative Perfusion SPECT software packages. Coronary angiographies were scored according to a four-point scoring system (angiographic score). Follow-up data were recorded after phone contact, as well as through review of hospital records. All participants were followed up for at least 36 months. Soft and hard cardiac events were recorded in 31.7% and 11.6% of the sample, respectively, while any cardiac event was recorded in 36.5%. For hard cardiac events, the prognostic value of expert scoring, combined with the prognostic value of the automated measurements, was significantly greater compared to the prognostic ability of the angiographic score (p < 0.001). As far as any cardiac event, the prognostic value of expert scoring, combined with the prognostic value of the automated analyses, was significantly greater compared to the prognostic ability of the angiographic score (p < 0.001). According to our results, in patients with known or suspected CAD, the combination of expert reading and automated measurements of SSS, SRS, and SDS shows a superior prognostic ability in comparison to the angiographic score.
- 25 December 2025
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (1) , 6
Open AccessLong-Term Prognostic Value in Nuclear Cardiology: Expert Scoring Combined with Automated Measurements vs. Angiographic Score
The evaluation of myocardial perfusion imaging (MPI) studies is based on the visual interpretation of the reconstructed images, while the measurements obtained through software packages may contribute to the investigation, mainly in cases of ambiguous scintigraphic findings. We aimed to investigate the long-term prognostic value of expert reading of Summed Stress Score (SSS), Summed Rest Score (SRS), and Summed Difference Score (SDS), combined with the automated measurements of these parameters, in comparison to the prognostic ability of the angiographic score for soft and hard cardiac events. The study was conducted at the Nuclear Medicine Laboratory of the University of Thessaly, in Larissa, Greece. Overall, 378 consecutive patients with known or suspected coronary artery disease (CAD) were enrolled. Automated measurements of SSS, SRS, and SDS were obtained using the Emory Cardiac Toolbox, Myovation, and Quantitative Perfusion SPECT software packages. Coronary angiographies were scored according to a four-point scoring system (angiographic score). Follow-up data were recorded after phone contact, as well as through review of hospital records. All participants were followed up for at least 36 months. Soft and hard cardiac events were recorded in 31.7% and 11.6% of the sample, respectively, while any cardiac event was recorded in 36.5%. For hard cardiac events, the prognostic value of expert scoring, combined with the prognostic value of the automated measurements, was significantly greater compared to the prognostic ability of the angiographic score (p < 0.001). As far as any cardiac event, the prognostic value of expert scoring, combined with the prognostic value of the automated analyses, was significantly greater compared to the prognostic ability of the angiographic score (p < 0.001). According to our results, in patients with known or suspected CAD, the combination of expert reading and automated measurements of SSS, SRS, and SDS shows a superior prognostic ability in comparison to the angiographic score.
- Open Access
Long-Term Prognostic Value of Automated Measurements in Nuclear Cardiology: Comparisons with Expert Scoring
Background and Objectives: Automated methods for the analysis of myocardial perfusion studies have been incorporated into clinical practice, but they are currently used as adjuncts to the visual interpretation. We aimed to investigate the role of automated measurements of summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) as long-term prognostic markers of morbidity and mortality, in comparison to the prognostic value of expert reading. Materials and Methods: The study was conducted at the Nuclear Medicine Laboratory of the University of Thessaly, in Larissa, Greece. A total of 378 consecutive patients with known or suspected coronary artery disease were enrolled in the study. All participants were referred to our laboratory for the performance of stress/rest myocardial perfusion single photon emission computed tomography. Automated measurements of SSS, SRS, and SDS were obtained by Emory Cardiac Toolbox (ECTb (Version 3.0), Emory University, Atlanta, GA, USA), Myovation (MYO, Xeleris version 3.05, GE Healthcare, Chicago, IL, USA), and Quantitative Perfusion SPECT (QPS (Version 4.0), Cedars-Sinai Medical Center, Los Angeles, CA, USA) software packages. Follow-up data were recorded after phone contacts, as well as through review of hospital records. Results: Expert scoring of SSS and SDS had significantly greater prognostic ability in comparison to all software packages (p < 0.001 for all comparisons). Similarly, ECTb-obtained SRS measurements had significantly lower prognostic ability in comparison to expert scoring (p < 0.001), while expert scoring of SRS showed significantly higher prognostic ability compared to MYO (p = 0.018) and QPS (p < 0.001). Conclusions: Despite the useful contribution of automated analyses in the interpretation of myocardial perfusion studies, expert reading should continue to have a crucial role, not only in clinical decision making, but also in the assessment of prognosis.
Open AccessLong-Term Prognostic Value of Automated Measurements in Nuclear Cardiology: Comparisons with Expert Scoring
Background and Objectives: Automated methods for the analysis of myocardial perfusion studies have been incorporated into clinical practice, but they are currently used as adjuncts to the visual interpretation. We aimed to investigate the role of automated measurements of summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) as long-term prognostic markers of morbidity and mortality, in comparison to the prognostic value of expert reading. Materials and Methods: The study was conducted at the Nuclear Medicine Laboratory of the University of Thessaly, in Larissa, Greece. A total of 378 consecutive patients with known or suspected coronary artery disease were enrolled in the study. All participants were referred to our laboratory for the performance of stress/rest myocardial perfusion single photon emission computed tomography. Automated measurements of SSS, SRS, and SDS were obtained by Emory Cardiac Toolbox (ECTb (Version 3.0), Emory University, Atlanta, GA, USA), Myovation (MYO, Xeleris version 3.05, GE Healthcare, Chicago, IL, USA), and Quantitative Perfusion SPECT (QPS (Version 4.0), Cedars-Sinai Medical Center, Los Angeles, CA, USA) software packages. Follow-up data were recorded after phone contacts, as well as through review of hospital records. Results: Expert scoring of SSS and SDS had significantly greater prognostic ability in comparison to all software packages (p < 0.001 for all comparisons). Similarly, ECTb-obtained SRS measurements had significantly lower prognostic ability in comparison to expert scoring (p < 0.001), while expert scoring of SRS showed significantly higher prognostic ability compared to MYO (p = 0.018) and QPS (p < 0.001). Conclusions: Despite the useful contribution of automated analyses in the interpretation of myocardial perfusion studies, expert reading should continue to have a crucial role, not only in clinical decision making, but also in the assessment of prognosis.
- Open Access
Automated Analysis vs. Expert Reading in Nuclear Cardiology: Correlations with the Angiographic Score
Background and Objectives: Myocardial perfusion imaging (MPI) has an important role in the non-invasive investigation of coronary artery disease. The interpretation of MPI studies is mainly based on the visual evaluation of the reconstructed images, while automated quantitation methods may add useful data for each patient. However, little evidence is currently available regarding the actual incremental clinical diagnostic performance of automated MPI analysis. In the present study, we aimed to assess the correlation between automated measurements of Summed Stress Score (SSS), Summed Rest Score (SRS) and Summed Difference Score (SDS), with the corresponding expert reading values, using coronary angiography as the gold standard. Materials and Methods: The study was conducted at the Nuclear Medicine Laboratory of the University Hospital of Larissa, Larissa, Greece, οver an one-year period (January 2019–January 2020). 306 patients, with known or suspected coronary artery disease, were enrolled in the study. Each participant underwent a coronary angiography, prior to or after the scintigraphic study (within a three-month period). Either symptom-limited treadmill test, or pharmacologic testing using adenosine or regadenoson, was performed in all participants, and the scintigraphic studies were carried out using technetium 99m (99mTc) tetrofosmin (one-day stress/rest protocol). Coronary angiographies were scored according to a 4-point scoring system (angiographic score; O: normal study, 1: one-vessel disease, 2: two-vessel disease, 3: three-vessel disease). Moreover, automated measurements of SSS, SRS and SDS were derived by three widely available software packages (Emory Cardiac Toolbox, Myovation, Quantitative Perfusion SPECT). Results: Interclass Correlation Coefficients of SSS, SRS and SDS between expert reading and software packages were moderate to excellent. Visually defined SSS, SRS and SDS were significantly correlated with the corresponding results of all software packages. However, visually defined SSS, SRS and SDS were more strongly correlated with the angiographic score, indicating a better performance of expert reading when compared to automated analysis. Conclusions: Based on our results, visual evaluation continues to have a crucial role for the interpretation of MPI images. Software packages can provide automated measurements of several parameters, particularly contributing to the investigation of cases with ambiguous scintigraphic findings.
Open AccessAutomated Analysis vs. Expert Reading in Nuclear Cardiology: Correlations with the Angiographic Score
Background and Objectives: Myocardial perfusion imaging (MPI) has an important role in the non-invasive investigation of coronary artery disease. The interpretation of MPI studies is mainly based on the visual evaluation of the reconstructed images, while automated quantitation methods may add useful data for each patient. However, little evidence is currently available regarding the actual incremental clinical diagnostic performance of automated MPI analysis. In the present study, we aimed to assess the correlation between automated measurements of Summed Stress Score (SSS), Summed Rest Score (SRS) and Summed Difference Score (SDS), with the corresponding expert reading values, using coronary angiography as the gold standard. Materials and Methods: The study was conducted at the Nuclear Medicine Laboratory of the University Hospital of Larissa, Larissa, Greece, οver an one-year period (January 2019–January 2020). 306 patients, with known or suspected coronary artery disease, were enrolled in the study. Each participant underwent a coronary angiography, prior to or after the scintigraphic study (within a three-month period). Either symptom-limited treadmill test, or pharmacologic testing using adenosine or regadenoson, was performed in all participants, and the scintigraphic studies were carried out using technetium 99m (99mTc) tetrofosmin (one-day stress/rest protocol). Coronary angiographies were scored according to a 4-point scoring system (angiographic score; O: normal study, 1: one-vessel disease, 2: two-vessel disease, 3: three-vessel disease). Moreover, automated measurements of SSS, SRS and SDS were derived by three widely available software packages (Emory Cardiac Toolbox, Myovation, Quantitative Perfusion SPECT). Results: Interclass Correlation Coefficients of SSS, SRS and SDS between expert reading and software packages were moderate to excellent. Visually defined SSS, SRS and SDS were significantly correlated with the corresponding results of all software packages. However, visually defined SSS, SRS and SDS were more strongly correlated with the angiographic score, indicating a better performance of expert reading when compared to automated analysis. Conclusions: Based on our results, visual evaluation continues to have a crucial role for the interpretation of MPI images. Software packages can provide automated measurements of several parameters, particularly contributing to the investigation of cases with ambiguous scintigraphic findings.
- Open Access
- 4 May 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (5) , 1136
Anosognosia in Dementia: Evaluation of Perfusion Correlates Using 99mTc-HMPAO SPECT and Automated Brodmann Areas Analysis
(1) Background: Considerable inconsistency exists regarding the neural substrates of anosognosia in dementia in previous neuroimaging studies. The purpose of this study was the evaluation of anosognosia perfusion correlates across various types of dementia using automated Brodmann areas (BAs) analysis and comparison with a database of normal subjects. (2) Methods: We studied 72 patients: 32 with Alzheimer’s disease, 26 with frontotemporal dementia—FTD (12 behavioral FTD, 9 semantic FTD, 5 Progressive Non-Fluent Aphasia), 11 with corticobasal syndrome, and 3 with progressive supranuclear palsy. Addenbrook’s Cognitive Examination—Revised (ACE-R) mean(±SD) was 55.6(±22.8). For anosognosia measurement, the Anosognosia Questionnaire—Dementia was used. Total anosognosia score mean(±SD) was 22.1(±17.9), cognitive anosognosia score mean(±SD) was 18.1(±15.1) and behavioral–mood anosognosia score mean(±SD) was 3.3(±4.7). (3) Results: Higher anosognosia total score was associated with hypoperfusion in the inferior temporal, anterior cingulate, and inferior frontal cortices of the right hemisphere (BAs 20R, 24R, 32R, 45R). Higher anosognosia cognitive score was correlated with hypoperfusion in the left middle and anterior temporal cortices, and right dorsal anterior cingulate cortex (BAs 21L, 22L, 32R). No association was found with behavioral–mood anosognosia. (4) Conclusions: Automated analysis of brain perfusion Single Photon Emission Computed Tomography could be useful for the investigation of anosognosia neural correlates in dementia.
- 4 May 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (5) , 1136
Open AccessAnosognosia in Dementia: Evaluation of Perfusion Correlates Using 99mTc-HMPAO SPECT and Automated Brodmann Areas Analysis
(1) Background: Considerable inconsistency exists regarding the neural substrates of anosognosia in dementia in previous neuroimaging studies. The purpose of this study was the evaluation of anosognosia perfusion correlates across various types of dementia using automated Brodmann areas (BAs) analysis and comparison with a database of normal subjects. (2) Methods: We studied 72 patients: 32 with Alzheimer’s disease, 26 with frontotemporal dementia—FTD (12 behavioral FTD, 9 semantic FTD, 5 Progressive Non-Fluent Aphasia), 11 with corticobasal syndrome, and 3 with progressive supranuclear palsy. Addenbrook’s Cognitive Examination—Revised (ACE-R) mean(±SD) was 55.6(±22.8). For anosognosia measurement, the Anosognosia Questionnaire—Dementia was used. Total anosognosia score mean(±SD) was 22.1(±17.9), cognitive anosognosia score mean(±SD) was 18.1(±15.1) and behavioral–mood anosognosia score mean(±SD) was 3.3(±4.7). (3) Results: Higher anosognosia total score was associated with hypoperfusion in the inferior temporal, anterior cingulate, and inferior frontal cortices of the right hemisphere (BAs 20R, 24R, 32R, 45R). Higher anosognosia cognitive score was correlated with hypoperfusion in the left middle and anterior temporal cortices, and right dorsal anterior cingulate cortex (BAs 21L, 22L, 32R). No association was found with behavioral–mood anosognosia. (4) Conclusions: Automated analysis of brain perfusion Single Photon Emission Computed Tomography could be useful for the investigation of anosognosia neural correlates in dementia.