Aleksandra Savić
Aleksandra Savić has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Antonije Onjia
Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11120 Belgrade, SERBIA
3 shared publications - Andrijana Miletić
Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11120 Belgrade, SERBIA
2 shared publications - Jelena Vesković
Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11120 Belgrade, SERBIA
2 shared publications - Milica Lučić
Innovation Center of the Faculty of Technology and Metallurgy, 11120 Belgrade, Serbia
2 shared publications - Danijela D. Maksin
Vinča Institute of Nuclear Sciences, Belgrade
1 shared publication - Goran T. Vladisavljevic
Chemical Engineering Department, Loughborough University, Loughborough LE11 3TU, UK
1 shared publication
Latest Publications
- Open Access
Occurrence, Variability, and Screening-Level Dietary Risk Assessment of Uranium in Coffee
This study analyzed 238U concentrations in 92 coffee samples across three categories: ground coffee products (GCPs), including ground coffee, ground coffee in capsules, ground coffee with surrogates, and ground surrogates; instant coffee (IC); and instant powders (IPs). It assessed non-carcinogenic and radiological risks (ELCRs) using deterministic and probabilistic (Monte Carlo simulation) methods, along with sensitivity analysis. 238U concentrations ranged from 1.15 to 253 µg/kg (mean: 21.5 µg/kg). IP exhibited the highest mean concentration (55.1 µg/kg), followed by IC (8.43 µg/kg), ground coffee (8.24 µg/kg), and capsules (5.47 µg/kg). Non-carcinogenic and radiological risks followed the order IP > GCP > IC. Hazard quotient (HQ) values remained below the safety threshold of 1 for all GCP and IC scenarios, even at six cups daily (max HQ: 0.228 for GCP, 0.0258 for IC). Conversely, the maximum HQ for IP reached 0.732 for three cups and 1.46 for six cups. At the 95th percentile, HQ values for IP reached 5.01 × 10−1 (three cups) and 9.97 × 10−1 (six cups), indicating potential non-carcinogenic risks. Radiological risks were consistently low; the highest ELCR was 6.53 × 10−6 for six cups of IP. At the 95th percentile, the values for three and six cups of IP reached ELCRs of 2.18 × 10−6 and 4.43 × 10−6. Sensitivity analysis identified 238U concentration as the primary driver of both HQ and ELCR.
Open AccessOccurrence, Variability, and Screening-Level Dietary Risk Assessment of Uranium in Coffee
This study analyzed 238U concentrations in 92 coffee samples across three categories: ground coffee products (GCPs), including ground coffee, ground coffee in capsules, ground coffee with surrogates, and ground surrogates; instant coffee (IC); and instant powders (IPs). It assessed non-carcinogenic and radiological risks (ELCRs) using deterministic and probabilistic (Monte Carlo simulation) methods, along with sensitivity analysis. 238U concentrations ranged from 1.15 to 253 µg/kg (mean: 21.5 µg/kg). IP exhibited the highest mean concentration (55.1 µg/kg), followed by IC (8.43 µg/kg), ground coffee (8.24 µg/kg), and capsules (5.47 µg/kg). Non-carcinogenic and radiological risks followed the order IP > GCP > IC. Hazard quotient (HQ) values remained below the safety threshold of 1 for all GCP and IC scenarios, even at six cups daily (max HQ: 0.228 for GCP, 0.0258 for IC). Conversely, the maximum HQ for IP reached 0.732 for three cups and 1.46 for six cups. At the 95th percentile, HQ values for IP reached 5.01 × 10−1 (three cups) and 9.97 × 10−1 (six cups), indicating potential non-carcinogenic risks. Radiological risks were consistently low; the highest ELCR was 6.53 × 10−6 for six cups of IP. At the 95th percentile, the values for three and six cups of IP reached ELCRs of 2.18 × 10−6 and 4.43 × 10−6. Sensitivity analysis identified 238U concentration as the primary driver of both HQ and ELCR.
- Open Access
Ultrasound-Assisted Extraction Followed by Inductively Coupled Plasma Mass Spectrometry and Multivariate Profiling of Rare Earth Elements in Coffee
A rapid and efficient ultrasound-assisted extraction (UAE) procedure followed by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of 14 rare earth elements (REEs) (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu), along with yttrium (Y) and scandium (Sc), in coffee samples. The method was validated using certified reference material (NIST SRM 1547), recovery tests at four fortification levels, and comparisons with microwave-assisted digestion (MAD). Excellent accuracy and precision were achieved, with recovery rates ranging from 80.1% to 112% and relative standard deviations (RSD%) below 14%. Limits of detection (LODs) ranged from 0.2 ng/kg (Yb) to 0.16 µg/kg (Nd). Total REE concentrations varied between 8.3 µg/kg and 1.1 mg/kg, with the highest individual mean concentrations (µg/kg) observed for Ce (11.7), La (6.0), and Sc (4.7). The lowest individual mean concentrations (µg/kg) were for Ho (0.16), Lu (0.066), and Tm (0.063). Multivariate analysis of REE profiles from 92 coffee samples collected in Serbia revealed clear distinctions between ground roasted and instant coffees, as well as between different surrogate blends. This study indicated that the determination of coffee’s geographical origin was not possible due to the diverse types, blends, and additives. However, differences in REE profiles suggest potential classification based on variety. REEs pose a negligible health risk to coffee consumers, with HI values ranging from 4.7 × 10−8 to 6.3 × 10−6 and TCR ranging from 2.6 × 10−14 to 3.5 × 10−12.
Open AccessUltrasound-Assisted Extraction Followed by Inductively Coupled Plasma Mass Spectrometry and Multivariate Profiling of Rare Earth Elements in Coffee
A rapid and efficient ultrasound-assisted extraction (UAE) procedure followed by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of 14 rare earth elements (REEs) (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu), along with yttrium (Y) and scandium (Sc), in coffee samples. The method was validated using certified reference material (NIST SRM 1547), recovery tests at four fortification levels, and comparisons with microwave-assisted digestion (MAD). Excellent accuracy and precision were achieved, with recovery rates ranging from 80.1% to 112% and relative standard deviations (RSD%) below 14%. Limits of detection (LODs) ranged from 0.2 ng/kg (Yb) to 0.16 µg/kg (Nd). Total REE concentrations varied between 8.3 µg/kg and 1.1 mg/kg, with the highest individual mean concentrations (µg/kg) observed for Ce (11.7), La (6.0), and Sc (4.7). The lowest individual mean concentrations (µg/kg) were for Ho (0.16), Lu (0.066), and Tm (0.063). Multivariate analysis of REE profiles from 92 coffee samples collected in Serbia revealed clear distinctions between ground roasted and instant coffees, as well as between different surrogate blends. This study indicated that the determination of coffee’s geographical origin was not possible due to the diverse types, blends, and additives. However, differences in REE profiles suggest potential classification based on variety. REEs pose a negligible health risk to coffee consumers, with HI values ranging from 4.7 × 10−8 to 6.3 × 10−6 and TCR ranging from 2.6 × 10−14 to 3.5 × 10−12.
- Open Access
Dispersive Solid–Liquid Microextraction Based on the Poly(HDDA)/Graphene Sorbent Followed by ICP-MS for the Determination of Rare Earth Elements in Coal Fly Ash Leachate
A dispersive solid-phase microextraction (DSPME) sorbent consisting of poly(1,6-hexanediol diacrylate)-based polymer microspheres, with embedded graphene microparticles (poly(HDDA)/graphene), was synthesized by microfluidic emulsification/photopolymerization and characterized by optical microscopy and X-ray fluorescence spectrometry. This sorbent was applied for simple, fast, and sensitive vortex-assisted DSPME of rare earth elements (RREs) in coal fly ash (CFA) leachate, prior to their quantification by inductively coupled plasma mass spectrometry (ICP-MS). Among nine DSPME variables, the Plackett–Burman screening design (PBD), followed by the central composite optimization design (CCD) using the Derringer desirability function (D), identified the eluent type as the most influencing DSPME variable. The optimum conditions with maximum D (0.65) for the chelating agent di-(2-ethylhexyl) phosphoric acid (D2EHPA) amount, the sorbent amount, the eluting solvent, the extraction temperature, the centrifuge speed, the vortexing time, the elution time, the centrifugation time, and pH, were set to 60 μL, 30 mg, 2 M HNO3, 25 °C, 6000 rpm, 1 min, 1 min, 5 min, and 4.2, respectively. Analytical validation of the DSPME method for 16 REEs (Sc, Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu) in CFA leachate samples estimated the detection limits at the low ppt level, the recovery range 43–112%, and relative standard deviation within ± 22%. This method was applied to a water extraction procedure (EP) and acetic acid toxicity characteristic leaching procedure (TCLP) for leachate of CFA, from five different coal-fired thermoelectric power plants. The most abundant REEs in leachate (20 ÷ 1 solid-to-liquid ratio) are Ce, Y, and La, which were found in the range of 22–194 ng/L, 35–105 ng/L, 48–95 ng/L, and 9.6–51 μg/L, 7.3–22 μg/L, 2.4–17 μg/L, for EP and TCLP leachate, respectively. The least present REE in TCLP leachate was Lu (42–125 ng/L), which was not detected in EP leachate.
Open AccessDispersive Solid–Liquid Microextraction Based on the Poly(HDDA)/Graphene Sorbent Followed by ICP-MS for the Determination of Rare Earth Elements in Coal Fly Ash Leachate
A dispersive solid-phase microextraction (DSPME) sorbent consisting of poly(1,6-hexanediol diacrylate)-based polymer microspheres, with embedded graphene microparticles (poly(HDDA)/graphene), was synthesized by microfluidic emulsification/photopolymerization and characterized by optical microscopy and X-ray fluorescence spectrometry. This sorbent was applied for simple, fast, and sensitive vortex-assisted DSPME of rare earth elements (RREs) in coal fly ash (CFA) leachate, prior to their quantification by inductively coupled plasma mass spectrometry (ICP-MS). Among nine DSPME variables, the Plackett–Burman screening design (PBD), followed by the central composite optimization design (CCD) using the Derringer desirability function (D), identified the eluent type as the most influencing DSPME variable. The optimum conditions with maximum D (0.65) for the chelating agent di-(2-ethylhexyl) phosphoric acid (D2EHPA) amount, the sorbent amount, the eluting solvent, the extraction temperature, the centrifuge speed, the vortexing time, the elution time, the centrifugation time, and pH, were set to 60 μL, 30 mg, 2 M HNO3, 25 °C, 6000 rpm, 1 min, 1 min, 5 min, and 4.2, respectively. Analytical validation of the DSPME method for 16 REEs (Sc, Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu) in CFA leachate samples estimated the detection limits at the low ppt level, the recovery range 43–112%, and relative standard deviation within ± 22%. This method was applied to a water extraction procedure (EP) and acetic acid toxicity characteristic leaching procedure (TCLP) for leachate of CFA, from five different coal-fired thermoelectric power plants. The most abundant REEs in leachate (20 ÷ 1 solid-to-liquid ratio) are Ce, Y, and La, which were found in the range of 22–194 ng/L, 35–105 ng/L, 48–95 ng/L, and 9.6–51 μg/L, 7.3–22 μg/L, 2.4–17 μg/L, for EP and TCLP leachate, respectively. The least present REE in TCLP leachate was Lu (42–125 ng/L), which was not detected in EP leachate.