Xiangqi Qin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiangqi Qin has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Dongsheng Ni
Institute of Modern Physics of Chinese Academy of Sciences, Lanzhou, China
7 shared publications - Enming Mei
Institute of Modern Physics of Chinese Academy of Sciences, Lanzhou, China
6 shared publications - Wei Wu
Institute of Modern Physics of Chinese Academy of Sciences, Lanzhou, China
6 shared publications - Li Zhu
Institute of Modern Physics of Chinese Academy of Sciences, Lanzhou, China
5 shared publications - Wei You
Institute of Modern Physics of Chinese Academy of Sciences, Lanzhou, China
5 shared publications - Xianjin Ou
Institute of Modern Physics of Chinese Academy of Sciences, Lanzhou, China
5 shared publications
Latest Publications
- 16 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Mechanical Design of the Fast-Cycling Superconducting Dipole Magnet
A fast-cycling superconducting dipole magnet with a central magnetic field of 6 T and a ramp rate of 1 T/s for ion synchrotron has been developed in the Institute of Modern Physics (IMP). A modified cosθ current distribution is adopted for the magnetic field design. The coil consists of eight layers of multi-strand round cables which are embedded into the machined grooves on the formers. Considering the high electromagnetic forces of the magnet, the nested coil winding is supported by a shell-based structure which uses an aluminum cylinder pre-tensioned using water-pressurized bladders and interference keys. This paper presents the mechanical design of the superconducting dipole magnet along with fabrication details, the room temperature assembly, and the cryogenic test results, respectively.
- 16 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Mechanical Design of the Fast-Cycling Superconducting Dipole Magnet
A fast-cycling superconducting dipole magnet with a central magnetic field of 6 T and a ramp rate of 1 T/s for ion synchrotron has been developed in the Institute of Modern Physics (IMP). A modified cosθ current distribution is adopted for the magnetic field design. The coil consists of eight layers of multi-strand round cables which are embedded into the machined grooves on the formers. Considering the high electromagnetic forces of the magnet, the nested coil winding is supported by a shell-based structure which uses an aluminum cylinder pre-tensioned using water-pressurized bladders and interference keys. This paper presents the mechanical design of the superconducting dipole magnet along with fabrication details, the room temperature assembly, and the cryogenic test results, respectively.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (3) , 1-5
Current Leads Test for FECR Cryostat
To fulfill the normal operational requirements of the fourth generation electron cyclotron resonance ion source (FECR) superconducting magnet, a cryostat in the form of liquid helium immersion was designed based on several Giffod McMahon cryocoolers. Considering the substantial number of current leads (a total of 9) and the high current value (with the maximum current of 709 A) of the superconducting magnet, a dedicated current lead test platform was designed and constructed to ensure operational stability and thermal management of the cryostat. This platform was utilized to conduct comprehensive tests on the high temperature superconductivity (HTS) leads and room temperature copper leads intended for use in the cryostat, including quantitative evaluation of conductive heating load and Joule heating load under operational conditions. The test results demonstrate that the designed leads can meet the normal working requirements of the FECR cryostat, achieving a maximum current capacity of 720 A with heat load of 28.88 W per copper lead and 0.12 W per HTS lead, respectively.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (3) , 1-5
Current Leads Test for FECR Cryostat
To fulfill the normal operational requirements of the fourth generation electron cyclotron resonance ion source (FECR) superconducting magnet, a cryostat in the form of liquid helium immersion was designed based on several Giffod McMahon cryocoolers. Considering the substantial number of current leads (a total of 9) and the high current value (with the maximum current of 709 A) of the superconducting magnet, a dedicated current lead test platform was designed and constructed to ensure operational stability and thermal management of the cryostat. This platform was utilized to conduct comprehensive tests on the high temperature superconductivity (HTS) leads and room temperature copper leads intended for use in the cryostat, including quantitative evaluation of conductive heating load and Joule heating load under operational conditions. The test results demonstrate that the designed leads can meet the normal working requirements of the FECR cryostat, achieving a maximum current capacity of 720 A with heat load of 28.88 W per copper lead and 0.12 W per HTS lead, respectively.
- 28 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (8) , 1-4
The Design and Testing of a Pre-cooling Helium Cryogenic Cryocooler for Compact Synchrotron
A project to develop core component for heavy-ion Synchrotron is underway in Lanzhou, having started in 2022. The aim of this project is reduced radius of the synchrotron by superconducting magnets. To cool the superconducting magnets of compact Heavy-Ion synchrotron, a pre-cooling helium cryogenic cryocooler is researched. The cryogenic system can generate over 10 watts cooling capacity at temperature of 4.5K. It adopts conduction pre-cooling with GM cryocoolers and is designed to be able to forced flow cooling superconducting magnets. To verify the process design and heat exchanger performance, an open circulation device with the same process as the designed model was built and a cooling test was carried out. As a result of the test, it was confirmed that the heat exchanger can achieve the designed heat transfer temperature. And it was also confirmed that there was a temperature gradient of about 5 K behind J-T valve between the measurement results and the thermal calculation results. The results of the present work shows that the open circulation system can realize rapid cooling and it has reference significance for the design of closed cycle cryogenic system. But there are some cooling process design needs further improvement in a later study.
- 28 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (8) , 1-4
The Design and Testing of a Pre-cooling Helium Cryogenic Cryocooler for Compact Synchrotron
A project to develop core component for heavy-ion Synchrotron is underway in Lanzhou, having started in 2022. The aim of this project is reduced radius of the synchrotron by superconducting magnets. To cool the superconducting magnets of compact Heavy-Ion synchrotron, a pre-cooling helium cryogenic cryocooler is researched. The cryogenic system can generate over 10 watts cooling capacity at temperature of 4.5K. It adopts conduction pre-cooling with GM cryocoolers and is designed to be able to forced flow cooling superconducting magnets. To verify the process design and heat exchanger performance, an open circulation device with the same process as the designed model was built and a cooling test was carried out. As a result of the test, it was confirmed that the heat exchanger can achieve the designed heat transfer temperature. And it was also confirmed that there was a temperature gradient of about 5 K behind J-T valve between the measurement results and the thermal calculation results. The results of the present work shows that the open circulation system can realize rapid cooling and it has reference significance for the design of closed cycle cryogenic system. But there are some cooling process design needs further improvement in a later study.
- 6 October 2023
- Published by Springer Nature
- p. 321-328
Conceptual Design of Cryogenic System for HFRS of HIAF Project
- 6 October 2023
- Published by Springer Nature
- p. 321-328
Conceptual Design of Cryogenic System for HFRS of HIAF Project
- 3 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (6) , 1-7
Design and Test of a Curved Canted–Cosine–Theta Superconducting Dipole Magnet for Next Generation Ion Therapy
The curved superconducting dipole magnet is the core component of the next generation ion therapy device. The superconducting dipole magnet prototype with a physical bend angle of 90°, a magnetic bend angle of 45°, a bend radius of 800 mm, and a bore of 98 mm diameter is developed in China based on a novel type of canted–cosine–theta (CCT) coil structure. The magnet design and manufacturing, and the quench protection system are reported first, and then the testing process of this curved CCT superconducting magnet, which reached the nominal current of 610 A and generated the magnetic field of 2.018 T, after five quench trainings in liquid helium test is reported, meeting the design indicators. A set of technical routes is explored through the development of the curved CCT magnet, providing support for the future ion therapy.
- 3 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (6) , 1-7
Design and Test of a Curved Canted–Cosine–Theta Superconducting Dipole Magnet for Next Generation Ion Therapy
The curved superconducting dipole magnet is the core component of the next generation ion therapy device. The superconducting dipole magnet prototype with a physical bend angle of 90°, a magnetic bend angle of 45°, a bend radius of 800 mm, and a bore of 98 mm diameter is developed in China based on a novel type of canted–cosine–theta (CCT) coil structure. The magnet design and manufacturing, and the quench protection system are reported first, and then the testing process of this curved CCT superconducting magnet, which reached the nominal current of 610 A and generated the magnetic field of 2.018 T, after five quench trainings in liquid helium test is reported, meeting the design indicators. A set of technical routes is explored through the development of the curved CCT magnet, providing support for the future ion therapy.
- 14 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (3) , 1-6
Quench Behavior of a Superconducting Dipole Magnet Protected by a Scheme With the Adjustable Quench-Back
The dynamic quench behavior is investigated for a superconducting dipole magnet wound with the six-round-one superconducting cables (six NbTi/Cu wires and one center copper wire), which is protected by a recently developed protection scheme based on the quench-back effect triggered by the center copper wire automatically. The quench transients were measured based on the real-time data acquisition (DAQ) system and also calculated by our previously developed quench model. During the energy discharge of the magnet, the featuring points can be observed on the evolution curves of coil current, induced current and voltage, which indicate the occurrence of a quench-back. By comparing the results for the cases with and without quench-back effect, the role of the quench-back on the quench protection is analyzed further. Meanwhile, the adjustable resistor can be utilized to control the quench-back effect to satisfy the quench protection requirements.
- 14 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (3) , 1-6
Quench Behavior of a Superconducting Dipole Magnet Protected by a Scheme With the Adjustable Quench-Back
The dynamic quench behavior is investigated for a superconducting dipole magnet wound with the six-round-one superconducting cables (six NbTi/Cu wires and one center copper wire), which is protected by a recently developed protection scheme based on the quench-back effect triggered by the center copper wire automatically. The quench transients were measured based on the real-time data acquisition (DAQ) system and also calculated by our previously developed quench model. During the energy discharge of the magnet, the featuring points can be observed on the evolution curves of coil current, induced current and voltage, which indicate the occurrence of a quench-back. By comparing the results for the cases with and without quench-back effect, the role of the quench-back on the quench protection is analyzed further. Meanwhile, the adjustable resistor can be utilized to control the quench-back effect to satisfy the quench protection requirements.
- 23 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
First Test of a Full Length Nb3Sn Sextupole Coil in a Mirror Structure for the FECR Ion Source
The new Nb 3 Sn superconducting magnet system for a 45 GHz electron cyclotron resonance (ECR) ion source is under development in the Institute of Modern Physics (IMP). The full-length sextupole coil is wound by a single Nb 3 Sn round wire. And due to the complicated technology process and the stress sensitivity, this coil is indeed a great technical challenge. In order to test the performance of the individual sextupole coil, a sextupole magnetic mirror structure based on the bladder and key technology is utilized. This paper presents the mechanical design of the mirror structure along with fabrication details, the room temperature assembly, and the first test results, respectively.
- 23 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
First Test of a Full Length Nb3Sn Sextupole Coil in a Mirror Structure for the FECR Ion Source
The new Nb 3 Sn superconducting magnet system for a 45 GHz electron cyclotron resonance (ECR) ion source is under development in the Institute of Modern Physics (IMP). The full-length sextupole coil is wound by a single Nb 3 Sn round wire. And due to the complicated technology process and the stress sensitivity, this coil is indeed a great technical challenge. In order to test the performance of the individual sextupole coil, a sextupole magnetic mirror structure based on the bladder and key technology is utilized. This paper presents the mechanical design of the mirror structure along with fabrication details, the room temperature assembly, and the first test results, respectively.
- 19 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-6
Study on Forced Flow Cooling of Superconducting Magnet for Compact Synchrotron
AbstractTo cool the superconducting magnets of a compact synchrotron, a forced flow cooling system with cooling capacity of 10.16 watts at 4.5 K based on GM/J-T concept is designed. As a preliminary research of the cooling system, a research device is built. The research device shares a similar flow diagram with the cooling system, but the GM cryocooler is replaced by a cold helium pre-cooling section to searching the system parameters and improve the system response speed. For the research device, the pre-cooling section consumes 0.332 g/s of liquid helium and generates 0.565 g/s of liquid helium after throttling by the J-T valve. To elucidate the performance of the heat exchangers based on enthalpy balance, the cycle point parameters are picked. The results of the thermomechanical analysis show that the temperature, the temperature difference and the pressure of helium at inlet of the JTH section how to affect the cooling capacity of the system. The heat leakage analysis, the design parameters optimization and the cycle efficiency improvement in the system are also discussed in this paper. Index TermsHelium refrigerator, Cryogenic system, Cooling capacity, Thermodynamic analysis
- 19 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-6
Study on Forced Flow Cooling of Superconducting Magnet for Compact Synchrotron
AbstractTo cool the superconducting magnets of a compact synchrotron, a forced flow cooling system with cooling capacity of 10.16 watts at 4.5 K based on GM/J-T concept is designed. As a preliminary research of the cooling system, a research device is built. The research device shares a similar flow diagram with the cooling system, but the GM cryocooler is replaced by a cold helium pre-cooling section to searching the system parameters and improve the system response speed. For the research device, the pre-cooling section consumes 0.332 g/s of liquid helium and generates 0.565 g/s of liquid helium after throttling by the J-T valve. To elucidate the performance of the heat exchangers based on enthalpy balance, the cycle point parameters are picked. The results of the thermomechanical analysis show that the temperature, the temperature difference and the pressure of helium at inlet of the JTH section how to affect the cooling capacity of the system. The heat leakage analysis, the design parameters optimization and the cycle efficiency improvement in the system are also discussed in this paper. Index TermsHelium refrigerator, Cryogenic system, Cooling capacity, Thermodynamic analysis
- 11 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
DCT&CCT Superconducting Multiplets for HIAF-HFRS
HIAF (High Intensity heavy ion Accelerator Facility) is the new generation heavy ion accelerator under construction in China. The HFRS (FRagment Separator of HIAF) is a fragment separator and also a transfer-line between the Booster Ring and the Spectrometer ring, which has magnetic rigidity up to 25 Tm. HFRS magnet system is composed of 11 superconducting dipoles and 13 sets of triplets. Several multipole magnets (an octupole coil, a quadrupole coil, and a sextupole coil) are nested together to compact the length of the HFRS-line. All of them feature high field gradients (13 T/m, 25 T/m 2 , 105 T/m 3 ) and large bores (320 mm). To reduce the cold mass and ensure the field quality, the whole multipole magnets are all designed with coil-dominated magnets of CCT (Canted Cosine Theta) and DCT (Discrete Cosine Theta). This paper will introduce the general design process of an HFRS multipole module. The development process and test results of the prototype will be presented.
- 11 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
DCT&CCT Superconducting Multiplets for HIAF-HFRS
HIAF (High Intensity heavy ion Accelerator Facility) is the new generation heavy ion accelerator under construction in China. The HFRS (FRagment Separator of HIAF) is a fragment separator and also a transfer-line between the Booster Ring and the Spectrometer ring, which has magnetic rigidity up to 25 Tm. HFRS magnet system is composed of 11 superconducting dipoles and 13 sets of triplets. Several multipole magnets (an octupole coil, a quadrupole coil, and a sextupole coil) are nested together to compact the length of the HFRS-line. All of them feature high field gradients (13 T/m, 25 T/m 2 , 105 T/m 3 ) and large bores (320 mm). To reduce the cold mass and ensure the field quality, the whole multipole magnets are all designed with coil-dominated magnets of CCT (Canted Cosine Theta) and DCT (Discrete Cosine Theta). This paper will introduce the general design process of an HFRS multipole module. The development process and test results of the prototype will be presented.