Octavio Ramírez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Octavio Ramírez has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Christopher René Torres-San Miguel
Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Zacatenco, Mexico City 07738, Mexico
4 shared publications - Alejandro Cuautle-Estrada
Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Zacatenco Edificio, Mexico City 07738, Mexico
2 shared publications - Marco Ceccarelli
Department of Industrial Engineering, University of Rome Tor Vergata, 00133 Rome, Italy
2 shared publications - Arturo Yishai Prieto-Vázquez
Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Zacatenco Edificio, Mexico City 07738, Mexico
1 shared publication - Mario Alberto Grave-Capistrán
Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado E Investigación
1 shared publication - Mijail A. Rivera-Hernández
Instituto Politécnico Nacional
1 shared publication
Latest Publications
- Open Access
- 28 May 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (3) , 561-581
Design of a Compliant Sternum Prosthesis for Improving Respiratory Dynamics
This study presents a novel approach to sternum prosthesis design, aiming to address the limitations of the current solutions by employing compliant mechanisms. The research focuses on developing a prosthetic design capable of generating lifting movements on ribs during breathing. First, a videogrammetry experimental test and virtual simulations were conducted to ascertain the vertical forces applied to each sternum joint. Subsequently, a compliant mechanism design was initiated, involving optimization and finite element analysis (FEM). A comprehensive kinematic performance analysis was performed to evaluate the prosthetic design. The results indicate that the obtained displacements of each rib closely align with those reported in the existing literature, demonstrating the effectiveness of the proposed solution. In conclusion, the developed sternum prosthesis exhibits the capability to recover approximately 56% of the ribs’ natural movements, highlighting its potential as an innovative and promising solution in the field of chest prosthetics.
- 28 May 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (3) , 561-581
Open AccessDesign of a Compliant Sternum Prosthesis for Improving Respiratory Dynamics
This study presents a novel approach to sternum prosthesis design, aiming to address the limitations of the current solutions by employing compliant mechanisms. The research focuses on developing a prosthetic design capable of generating lifting movements on ribs during breathing. First, a videogrammetry experimental test and virtual simulations were conducted to ascertain the vertical forces applied to each sternum joint. Subsequently, a compliant mechanism design was initiated, involving optimization and finite element analysis (FEM). A comprehensive kinematic performance analysis was performed to evaluate the prosthetic design. The results indicate that the obtained displacements of each rib closely align with those reported in the existing literature, demonstrating the effectiveness of the proposed solution. In conclusion, the developed sternum prosthesis exhibits the capability to recover approximately 56% of the ribs’ natural movements, highlighting its potential as an innovative and promising solution in the field of chest prosthetics.
- Open Access
- 31 August 2023
- Published by MDPI AG in Fractal and Fractional
- Vol. 7 (9) , 661
Fractal Analysis and FEM Assessment of Soft Tissue Affected by Fibrosis
This research shows an image processing method to determine the liver tissue’s mechanical behavior under physiological damage caused by fibrosis pathology. The proposed method consists of using a liver tissue CAD/CAE model obtained from a tomography of the human abdomen, where the diaphragmatic surface of this tissue is compressed by a moving flat surface. For this work, two tools were created—the first to analyze the deformations and the second to analyze the displacements of the liver tissue. Gibbon and MATLAB® were used for numerical analysis with the FEBio computer program. Although deformation in the scenario can be treated as an orthogonal coordinate system, the relationship between the total change in height (measured) and the deformation was obtained. The outcomes show liver tissue behavior as a hyperelastic model; the Mooney–Rivlin mathematical characterization model was proposed in this case. Another method to determine the level of physiological damage caused by fibrosis is fractal analysis. This work used the Hausdorff fractal dimension (HFD) method to calculate and analyze the 2D topological surface.
- 31 August 2023
- Published by MDPI AG in Fractal and Fractional
- Vol. 7 (9) , 661
Open AccessFractal Analysis and FEM Assessment of Soft Tissue Affected by Fibrosis
This research shows an image processing method to determine the liver tissue’s mechanical behavior under physiological damage caused by fibrosis pathology. The proposed method consists of using a liver tissue CAD/CAE model obtained from a tomography of the human abdomen, where the diaphragmatic surface of this tissue is compressed by a moving flat surface. For this work, two tools were created—the first to analyze the deformations and the second to analyze the displacements of the liver tissue. Gibbon and MATLAB® were used for numerical analysis with the FEBio computer program. Although deformation in the scenario can be treated as an orthogonal coordinate system, the relationship between the total change in height (measured) and the deformation was obtained. The outcomes show liver tissue behavior as a hyperelastic model; the Mooney–Rivlin mathematical characterization model was proposed in this case. Another method to determine the level of physiological damage caused by fibrosis is fractal analysis. This work used the Hausdorff fractal dimension (HFD) method to calculate and analyze the 2D topological surface.
- 14 April 2023
- Published by Springer Nature
- p. 11-18
A Study of Feasibility of a Mechanism for Rib-Vertebra-Sternum Prosthesis
- 14 April 2023
- Published by Springer Nature
- p. 11-18
A Study of Feasibility of a Mechanism for Rib-Vertebra-Sternum Prosthesis